DECANTER CENTRIFUGES

& PLANTS FOR SOLID/LIQUID SEPARATION

DECANTER CENTRIFUGES FOR USAGE EXAMPLES


for explosion protection
OPERATION IN THE ATEX INDUSTRY equipment

■ during the classifying of colour


For performance in accordance with pigments in a benzine suspension
RL 2014/34/EU requirements ■ in the use of alcohol-soaked herbs
and root extracts
HILLER decanters and equipment are As a German manufacturer, HILLER al-
used in many situations where protec- ways uses ATEX (AT-mosphére EXplosive)
■ during the chemical separation of
intermediate products of acetone
tion from explosion is also necessary. For as the basis for design.
instance in many areas of industrial pro- However, a design according to country- ■ during the separation of a methanol
duction where raw materials and envi- specific requirements (e.g. according to wash from a salt suspension
ronmental technology is used, and where NEC 500 or NEC 505) is also possible. ■ during the processing of waste from
products being processed may create a the mineral oil industry
situation when an explosive atmosphere Explosion protected HILLER decanters
may be created. and associated equipment are certified
The appropriate equipment is necessary for RL 2014/34/EU requirements and are
in order to protect people and equip- available for a variety of Ex-zones, gas
ment from the danger. groups and temperature classes.

separation & process


EXPLOSION PROTECTION

In the design of the explosion protected


equipment the following general requi-
rements are decisive:
■ site environment
the level of liklihood of an explosion
■ product
whether the processing of the
product can result in an explosive
atmosphere (e.g. via outgassing, fine
atomisation, etc.)

RELY ON OUR
LONG YEARS OF EXPERIENCE

Depending on the application/ process,


the concept „explosion-protection“ can
include a wide range of measures. In
the simplest cases the use of explosion- SCC-CERTIFICATED PERSONNEL REQUIREMENTS FOR EXPLOSION
protected drive motors and instruments PROTECTION
is sufficient. With the increasing potential Regarding the security-relevant and The hazards of a process are assessed by
for danger the demands are on design complex topic of explosion protection the operator.
and construction up to a so-called gas- HILLER can guarantee the quality of work Important criteria are, amongst others,
tight design in which exposure to inert from their internal personnel, who have the liklihood of explosion, which is stated
gas is prevented. years-long experience and competence, by the term of Category, for example the
and are SCC certificated (SCC-Safety Cer- zone, and would be written as follows:
The installation of switchgear within an tificate Contractors). ■ Category 1 = Zone 0 resp. 20
explosion endangered area can be achie- high or constant liklihood of
ved through the use of pressurized con- Explosion protected HILLER decanters explosion
trol cabinets. and equipment are always designed and ■ Category 2 = Zone 1 resp. 21
manufactured to the specific require- occasional danger of explosion
Additionally the HILLER decanters can ments of the intended operational use. ■ Category 3 = Zone 2 resp. 22
be fitted out with full hydraulic drives to seldom and short term danger of
achieve full variability of bowl and diffe- We support our customers during the explosion
rential speed without the need for a fre- whole process of designing and develo-
quency inverter. ping an optimal solution for the relevant Further important parameters of a
demands. medium are:
You can rely on our extensive knowledge. ■ the flashpoint
■ the ignition temperature
■ the ignition energy
■ upper explosion limit
■ lower explosion limit
The temperature class of the equipment
is derived from the ignition temperature.

HILLER GmbH . Schwalbenholzstraße 2 . 84137 Vilsbiburg . Tel +49 8741 48-0 . info@hillerzentri.de . www.hillerzentri.de