1. Safety Rules
1. Personnel must have the required qualifications for carrying out any work on the machine.
2. The personnel must act in accordance with the existing safety regulations.
4. The user-owner of the machine must meet the necessary obligations to ensure that the machine can be operated
safely.
5. The machine may only be used for the purpose for which it is designed.
6. The machine is safe to operate but please note, however, that it still presents residual risks which must be taken
into account.
7. Bear in mind that energy systems, operating and processing materials, and emissions are potentially hazardous.
8. The safe and technically perfect condition of the machine is essential for the operational safety of the machine and
the safety of personnel.
9. The safety and protective equipment on the machine is designed to protect the personnel and the machine.
Therefore, make sure that these devices always operate properly and are ready for operation: Do not tamper with
the safety and protective devices.
10. Obey the current regulations and instructions to ensure that you act correctly and safely in dangerous situations or
in the event of accidents.
2. Getting Started
2.1 Main Screens
1. Main screen: Displays information about the state
of every compressor connected and virtual buttons
(and the corresponding F1 to F8 physical buttons)
⚠ The Trend option is currently under
development.
Figure 2: Menu
Figure 4: Counters
Figure 6: AF menu
Figure 7: Information
3. Parameters
3.1 Operating Parameter (P100)
Figure 9: Set
date and time
This menu is accessible from the configuration compressor menu by pressing the specific "Configuration" button (see figure
13) and is mainly used to modify the AFS regulation parameter (password required for any change).
Without a password, you can only change the name of the compressor.
On this screen, you can follow the state of every digital outputs and/or test them.
⚠ Digital Outputs can only be tested when the machine is stopped.
On this screen, you can follow the state of every digital inputs.
On this screen, you can change the IP address and id /port for each connections or add a new one.
There is the possibility to change manually the port by selecting the "manual" option from the drop down list.
A password is required for any change.
On this screen, you can create a new RS485 Bus communication and/or configure its address.
A password is required for any change.