Professional Documents
Culture Documents
Multifix All Mechanical Anchor - Design Guide
Multifix All Mechanical Anchor - Design Guide
Multifix All Mechanical Anchor - Design Guide
MECHANICAL ANCHOR
WEDGE ANCHOR FOR NON-CRACKED CONCRETE
Description
MULTIFIX Wedge Anchor is a medium duty with small anchor spacing and edge distances.
Time saving through fastening installations, no special drilling and setting tools are required.
Tightening the hexagon nut expands the stainless steel sleeve which produces permanent
grip in non-cracked concrete
Application
Medium duty anchoring in non-cracked concrete: steel beams, base plates, channel, tracks
and wood structures.
Features:
Wedge Anchor is a complete unit ready to install system for through fixing: no marking out and repositioning
True dimension anchor, hole size, anchor diameter and threaded size are all the same diameter
Fully assembled with one piece wrap around sleeve which affords high anti-corrosion properties for long-term performance.
Anti-Rotation lugs
Dot-point stud head prevent damage to the threads during setting
TECHNICAL DATA
Design Design
Fixture Anchor Fixture Drill Hole Effective
Product Code Threaded Tensile Shear
HDG – Hot Dipped Galvanised
Thickness Length Hole do x ho Setting
Size Resistance Resistance
(mm) (mm) (mm) (mm) Depth
[KN] C25/30 [KN] C25/30
MF-WA 06055
M6 10 55 7 6 x 40 1.6 1.6 (30)
MF-WA 06085
M6 20 85 7 6 x 60 3.3 3.3 50
MF-WA 08065
M8 10 65 9 8 x 50 3.7 3.7 (40)
MF-WA 08080
M8 10 80 9 8 x 65 6.0 6.0 55
MF-WA 08090
M8 20 90 9 8 x 65 6.0 6.0 55
MF-WA 08115
M8 45 115 9 8 x 65 6.0 6.0 55
MF-WA 10075
M10 10 75 11 10 x 55 4.5 4.5 (40)
MF-WA 10090
M10 5 90 11 10 x 75 8.2 13.0 60
MF-WA 10095
M10 10 95 11 10 x 75 8.2 13.0 60
MF-WA 10120
M10 35 120 11 10 x 75 8.2 13.0 60
MF-WA 12080
M12 5 80 14 12 x 65 6.6 6.6 (50)
MF-WA 12100
M12 10 100 14 12 x 80 9.6 18.9 65
MF-WA 12120
M12 30 120 14 12 x 80 9.6 18.9 65
MF-WA 12140
M12 50 140 14 12 x 80 9.6 18.9 65
MF-WA 16125
16115
M16 15
5 125
115 18 16 x 95 13.8 27.6
27.6 (80)
MF-WA 16125 HDG
MF-WA 16125
M16 15 125 18 16 x 95 13.8 27.6
27.6 (80)
MF-WA 16125 HDG
MF-WA 16145
M16 15 145 18 16 x 115 19.2 35.3 100
MF-WA 16150
M16 20 150 18 16 x 115 19.2 35.3 100
MF-WA 16175
M16 45 175 18 16 x 115 19.2 35.3 100
MF-WA 20130
M20 10 130 22 20 x 130 16.3 32.6 (80)
MF-WA 20170
M20 30 170 22 20 x 130 22.7 45.4 100
MF-WA 20215
M20 75 215 22 20 x 130 22.7 45.4 100
01
WEDGE ANCHOR FOR NON-CRACKED CONCRETE
Installation parameters
Drill hole diameter do [mm] 6 8 10 12 16 20
Diameter of clearance hole in the
df [mm] 7 9 11 14 18 22
fixture
Depth of drill hole
h0 [mm] 60 / 40 65 / 50 75 / 55 80 / 65 115 / 95 130 / 110
(Standard / Reduced Depth)
Installation Tighten Torque Tinst [Nm] 10 20 40 50 100 160
Width across nut SW [mm] 10 13 17 19 24 30
MF-WA Steel 5.8 NRd,s 6.9 12.7 20.1 29.2 54.4 84.9
02
WEDGE ANCHOR FOR NON-CRACKED CONCRETE
o
1.2.1 Design pull-out resistance in Concrete C25/30 without spacing edge distance : N Rd,p
M20
Anchor size Threaded M6 M8 M10 M12 M16
MF-WA (Standard / Reduced Depth) NRd,p [KN] 3.3/1.6 6.0/3.7 8.2/4.5 9.6/6.6 19.2/13.8 22.7/16.3
Effective anchorage depth
hef [mm] 50/30 55/40 60/40 65/50 100/80 100/80
(Standard / Reduced Depth)
Characteristic Spacing (3hef)
scr [mm] 150/90 165/120 180/120 195/150 300/240 300/240
(Standard / Reduced Depth)
NRd,p = NRk / γMC of 2.16
o
1.2.2 Design pull-out resistance with Minimum edge distance in Concrete C25/30 : N Rd,p
1.2.3 Recommended pull-out resistance without edge distance and spacing in Concrete C25/30 : Nrec
fck,cyl [N/mm2 ] 20 25 30 35 40 45 50
fck,cyl [N/mm2 ] 25 30 37 45 50 55 60
o
N Rd,c : Design concrete cone resistance in C25/30
MF-WA N
o
Rd,c [KN] 10.9/5.0 12.5/7.8 14.3/7.8 16.0/10.9 30.7/22.0 30.7/22.0
Effective anchorage depth
hef [mm] 50/30 55/40 60/40 65/50 100/80 100/80
(Standard / Reduced Depth)
of
NRd,c = NRk,c / γMC 1.8
03
WEDGE ANCHOR FOR NON-CRACKED CONCRETE
1.4 NRd: Design tensile resistance: NRd = min ( NRd,s ;NRd,p ; NRd,c )
04
WEDGE ANCHOR FOR NON-CRACKED CONCRETE
MF-WA Steel 5.8 VRd,s 4.0 7.6 12.1 17.5 32.6 51.0
MF-WA Steel 5.8 Vrec 2.9 5.4 8.6 12.5 23.5 36.4
MF-WA V
o
Rd,cp [KN] 3.3/1.6 6.0/3.7 16.4 / 4.5 19.2/6.6 38.4/27.6 45.4 /32.6
0
V Rd,c: design resistance for single anchors with edge distances cmin, C25/30
V0Rd,c = Concrete design edge resistance ( V0Rd,c = 0.45 . √dnom . (lf /dnom)0.2 . √fck,cube . C11.5 / γMC = 1.5 [N] (Multiply 1.4 for Non-cracked concrete)
o
MF-WA V Rd,c [KN] 1.8/1.6 2.0/1.9 3.1/2.9 4.0/3.7 9.5/9.1 14.1/13.6
05
WEDGE ANCHOR FOR NON-CRACKED CONCRETE
J
P1@uD4 ?]U[dT]RT ^U TSVT SXbcP]RT P]S b_PRX]V
W < 1.5 > C W 4 1.5 > C
GX]V[T P]RW^a a a
^a Va^d_ P]RW^a fXcW b . -R \ \
_CR1V A
\fbg \fbg _CR1V A 63: 63:
\fbg \fbg
b
CV
8a 0 k a
7]RW^a _PXa fXcW b 4 -R _CR1V A 8\ 0 k \
_CR1V A 63: 63:
;\fbg \fbg ;\fbg \fbg
R
CW CW W
G+ G, G-}}}} G]|+
P1@uD
\ a
fbg
\fbg @ 63:\fbg
z zw{ zw} zw* zw, { {w{ {w} {w* {w, | |w{ |w} |w* |w, }
ASWQUO KWMRX[ r\ 0 ys +}** +}-+ +}00 ,}*, ,}.+ ,}2- -},0 -}1, .}+3 .}03 /},* /}1, 0},1 0}2- 1}.+ 2}**
nlu *}0, *}13 *}31 +}+0 +}-0 +}/2 +}2* ,}*. ,},2 ,}/. ,}2* -}*1 -}-/ -}0. -}3- .},-
nlv *}0- *}2* *}33 +}+2 +}-3 +}0* +}2- ,}*1 ,}-+ ,}/1 ,}2- -}+* -}-2 -}01 -}30 .},1
nlw *}0/ *}2, +}*+ +},* +}.+ +}0- +}2/ ,}*3 ,}-. ,}/3 ,}20 -}+- -}.+ -}1* .}** .}-*
o *}01 *}2. +}*- +},, +}.- +}0/ +}22 ,}+, ,}-0 ,}0, ,}23 -}+0 -}.. -}1- .}*- .}--
ols *}1/ *}3- +}+, +}-- +}/. +}11 ,}** ,},/ ,}/* ,}10 -}*- -}-+ -}0* -}23 .}+3 .}/*
p *}2- +}*, +},, +}.- +}0/ +}23 ,}+- ,}-2 ,}0- ,}3* -}+2 -}.0 -}1/ .}*/ .}-/ .}01
pls *}3, +}++ +}-, +}/. +}11 ,}** ,},/ ,}/* ,}11 -}*. -}-, -}0+ -}3* .},+ .}/, .}2-
q +}** +},* +}., +}0. +}22 ,}+, ,}-1 ,}0- ,}3* -}+2 -}.0 -}10 .}*0 .}-0 .}02 /}**
qls +}-* +}/, +}1/ +}33 ,},. ,}/* ,}10 -}*. -}-, -}0+ -}3+ .},+ .}/, .}2. /}+1
r +}0, +}20 ,}+* ,}-0 ,}0, ,}23 -}+1 -}.0 -}1/ .}*/ .}-0 .}02 /}** /}--
rls +}30 ,},+ ,}.1 ,}1. -}*, -}-+ -}0* -}3* .},* .}/, .}2. /}+1 /}/*
1WMRX[ YKS[
s ,}-- ,}/3 ,}21 -}+/ -}.. -}1. .}*. .}-/ .}01 /}** /}-- /}01
Ax3VSW
sls ,}1+ ,}33 -},2 -}/1 -}22 .}+3 .}/* .}2, /}+/ /}.3 /}2-
t ,}2- -}++ -}.+ -}1+ .}*, .}-- .}0/ .}32 /}-+ /}0/ 0}**
tls -},. -}/. -}2. .}+0 .}.1 .}2* /}+- /}.1 /}2, 0}+1
u -}01 -}32 .},3 .}0, .}3/ /},3 /}0- /}32 0}--
uls .}++ .}.- .}10 /}+* /}.. /}13 0}+. 0}/*
v .}/1 .}3+ /},/ /}/3 /}3/ 0}-* 0}01
vls /}*/ /}.* /}1/ 0}+* 0}.1 0}2-
w /},* /}// /}3* 0},0 0}0- 1}**
wls /}03 0}*/ 0}., 0}13 1}+1
on 0},+ 0}/2 0}3/ 1}--
onls 0}1. 1}+, 1}/*
oo 1},2 1}01
ools 1}2-
op 2}**
X]cTa\TSXPcT eP[dTb Qh [X]TPa X]cTa_^[PcX^]
CbS JbS
9^\QX]TS cT]bX^] P]S bWTPa [^PS4 z < 1.2
CFS JFS
MULTIFIX makes recommendations for its product only, and the recommendations are not intended to supersede any relevant guideline or design code of practice.
06
WEDGE ANCHOR FOR NON-CRACKED CONCRETE
Description
MULTIFIX Wedge Anchor is a medium duty with small anchor spacing and edge distances.
Time saving through fastening installations, no special drilling and setting tools are required.
Tightening the hexagon nut expands the stainless steel sleeve which produces permanent
grip in non-cracked concrete
Application
Medium duty anchoring in non-cracked concrete: steel beams, base plates, channel, tracks
and wood structures.
Features:
Wedge Anchor is a complete unit ready to install system for through fixing: no marking out and repositioning
True dimension anchor, hole size, anchor diameter and threaded size are all the same diameter
Fully assembled with one piece wrap around sleeve which affords high anti-corrosion properties for long-term performance.
Anti-Rotation lugs
Dot-point stud head prevent damage to the threads during setting
07
WEDGE ANCHOR FOR NON-CRACKED CONCRETE
Installation parameters
Drill hole diameter do [mm] 6 8 10 12 16 20
Diameter of clearance hole in the
df [mm] 7 9 11 14 18 22
fixture
Depth of drill hole
h0 [mm] 60 / 40 65 / 50 75 / 55 80/ 65 115 / 95 130 / 110
(Standard / Reduced Depth)
Installation Tighten Torque Tinst [Nm] 8 15 35 50 100 150
Width across nut SW [mm] 10 13 17 19 24 30
o
NRd,p = N Rd,p . fBN . fAN . fRN
08
WEDGE ANCHOR FOR NON-CRACKED CONCRETE
o
1.2.1 Design pull-out resistance in Concrete C25/30 without spacing edge distance : N Rd,p
M20
Anchor size Threaded M6 M8 M10 M12 M16
MF-WA (Standard / Reduced Depth) NRd,p [KN] 3.0/1.4 5.3/3.3 7.4/4.0 8.7 /5.9 17.1/12.5 20.4/14.7
Effective anchorage depth
hef [mm] 50/30 55/40 60/40 65/50 100/80 100/80
(Standard / Reduced Depth)
Characteristic Spacing (3hef)
scr [mm] 150/90 165/120 180/120 195/150 300/240 300/240
(Standard / Reduced Depth)
NRd,p = NRk / γMC of 2.16
o
1.2.2 Design pull-out resistance with Minimum edge distance in Concrete C25/30 : N Rd,p
1.2.3 Recommended pull-out resistance without edge distance and spacing in Concrete C25/30 : Nrec
fck,cyl [N/mm2 ] 20 25 30 35 40 45 50
2
fck,cyl [N/mm ] 25 30 37 45 50 55 60
fBN / fBV 0.90/0.90 1.00/1.00 1.00/1.10 1.00 /1.22 1.00/1.29 1.00/1.35 1.00/1.41
o
N Rd,c : Design concrete cone resistance in C25/30
MF-WA N
o
Rd,c [KN] 10.9/5.0 12.5/7.8 14.3/7.8 16.0/10.9 30.7/22.0 30.7/22.0
Effective anchorage depth
hef [mm] 50/30 55/40 60/40 65/50 100/80 100/80
(Standard / Reduced Depth)
of
NRd,c = NRk,c / γMC 1.8
09
WEDGE ANCHOR FOR NON-CRACKED CONCRETE
1.4 NRd: Design tensile resistance: NRd = min ( NRd,s ;NRd,p ; NRd,c )
10
WEDGE ANCHOR FOR NON-CRACKED CONCRETE
MF-WA V
o
Rd,cp [KN] 3.0/1.4 5.3/3.3 14.8/4.0 17.4/ 5.9 34.2/25.0 40.8 /29.4
0
V Rd,c: design resistance for single anchors with edge distances c min, C25/30
V0Rd,c = Concrete design edge resistance ( V0Rd,c = 0.45 . √dnom . (lf /dnom)0.2 . √fck,cube . C11.5 / γMC = 1.5 [N] (Multiply 1.4 for Non-cracked concrete)
11
WEDGE ANCHOR FOR NON-CRACKED CONCRETE
J
P1@uD4 ?]U[dT]RT ^U TSVT SXbcP]RT P]S b_PRX]V
h < 1.5 > C h < 1.5 > C
GX]V[T P]RW^a a a
^a Va^d_ P]RW^a fXcW b . -R _CR1V A \ \
_CR1V A 63: 63:
\fbg \fbg \fbg \fbg
b
CV
8a 0 k a
7]RW^a _PXa fXcW b 4 -R _CR1V A 8\ 0 k \
_CR1V A 63: 63:
;\fbg \fbg ;\fbg \fbg
R
CW CW W
G+ G, G-}}}} G]|+
P1@uD
\ a
fbg
\fbg @ 63:\fbg
z zw{ zw} zw* zw, { {w{ {w} {w* {w, | |w{ |w} |w* |w, }
ASWQUO KWMRX[ r\ 0 ys +}** +}-+ +}00 ,}*, ,}.+ ,}2- -},0 -}1, .}+3 .}03 /},* /}1, 0},1 0}2- 1}.+ 2}**
nlu *}0, *}13 *}31 +}+0 +}-0 +}/2 +}2* ,}*. ,},2 ,}/. ,}2* -}*1 -}-/ -}0. -}3- .},-
nlv *}0- *}2* *}33 +}+2 +}-3 +}0* +}2- ,}*1 ,}-+ ,}/1 ,}2- -}+* -}-2 -}01 -}30 .},1
nlw *}0/ *}2, +}*+ +},* +}.+ +}0- +}2/ ,}*3 ,}-. ,}/3 ,}20 -}+- -}.+ -}1* .}** .}-*
o *}01 *}2. +}*- +},, +}.- +}0/ +}22 ,}+, ,}-0 ,}0, ,}23 -}+0 -}.. -}1- .}*- .}--
ols *}1/ *}3- +}+, +}-- +}/. +}11 ,}** ,},/ ,}/* ,}10 -}*- -}-+ -}0* -}23 .}+3 .}/*
p *}2- +}*, +},, +}.- +}0/ +}23 ,}+- ,}-2 ,}0- ,}3* -}+2 -}.0 -}1/ .}*/ .}-/ .}01
pls *}3, +}++ +}-, +}/. +}11 ,}** ,},/ ,}/* ,}11 -}*. -}-, -}0+ -}3* .},+ .}/, .}2-
q +}** +},* +}., +}0. +}22 ,}+, ,}-1 ,}0- ,}3* -}+2 -}.0 -}10 .}*0 .}-0 .}02 /}**
qls +}-* +}/, +}1/ +}33 ,},. ,}/* ,}10 -}*. -}-, -}0+ -}3+ .},+ .}/, .}2. /}+1
r +}0, +}20 ,}+* ,}-0 ,}0, ,}23 -}+1 -}.0 -}1/ .}*/ .}-0 .}02 /}** /}--
rls +}30 ,},+ ,}.1 ,}1. -}*, -}-+ -}0* -}3* .},* .}/, .}2. /}+1 /}/*
1WMRX[ YKS[
s ,}-- ,}/3 ,}21 -}+/ -}.. -}1. .}*. .}-/ .}01 /}** /}-- /}01
Ax3VSW
sls ,}1+ ,}33 -},2 -}/1 -}22 .}+3 .}/* .}2, /}+/ /}.3 /}2-
t ,}2- -}++ -}.+ -}1+ .}*, .}-- .}0/ .}32 /}-+ /}0/ 0}**
tls -},. -}/. -}2. .}+0 .}.1 .}2* /}+- /}.1 /}2, 0}+1
u -}01 -}32 .},3 .}0, .}3/ /},3 /}0- /}32 0}--
uls .}++ .}.- .}10 /}+* /}.. /}13 0}+. 0}/*
v .}/1 .}3+ /},/ /}/3 /}3/ 0}-* 0}01
vls /}*/ /}.* /}1/ 0}+* 0}.1 0}2-
w /},* /}// /}3* 0},0 0}0- 1}**
wls /}03 0}*/ 0}., 0}13 1}+1
on 0},+ 0}/2 0}3/ 1}--
onls 0}1. 1}+, 1}/*
oo 1},2 1}01
ools 1}2-
op 2}**
X]cTa\TSXPcT eP[dTb Qh [X]TPa X]cTa_^[PcX^]
CbS JbS
9^\QX]TS cT]bX^] P]S bWTPa [^PS4 z < 1.2
CFS JFS
MULTIFIX makes recommendations for its product only, and the recommendations are not intended to supersede any relevant guideline or design code of practice.
12
SLEEVE ANCHOR FOR NON-CRACKED CONCRETE
Description
MULTIFIX Sleeve Anchor is a general purpose all steel medium duty through fixing
for masonry and concrete
Application
Timber to comcrete, form work, battens, bottom plates, services ductwork, pipe brackets,
cable trays, suspending ceilings, metalwork, sign, handrails, gates, light to medium duty fixing.
Features:
Through fixing – no marking out and repositioning.
Unique sleeve design collapse during tightening to provide pull down
onto fixture.
Fully assembled with Integral nut and washer
TECHNICAL DATA
Design Design Effective
Fixture Anchor Fixture Drilled Hole
Threaded Tensile Shear Setting
Product Code Thickness Length Hole do x ho
Size Resistance Resistance Depth
(mm) (mm) (mm) (mm)
C25/30 [KN] C25/30 [KN] (mm)
13
SLEEVE ANCHOR FOR NON-CRACKED CONCRETE
Threaded
MF-SA M5 M6 M8 M10 M12 M16
Diameter
Characteristic loads, tension
NRK [KN] 3.6 / 1.9 5.0 7.5 / 4.9 10.0 15.0 20.0
(Standard / Reduced Depth)
Characteristic loads, shear VRK [KN] 3.0 6.3 11.3 18.4 22.0 27.0
Effective anchorage depth
hef [mm] 27/18 30 40/30 46 52 60
(Standard / Reduced Depth)
Installation parameters
14
SLEEVE ANCHOR FOR NON-CRACKED CONCRETE
o
Design pull-out resistance in Concrete C25/30 without spacing & edge Distance : N Rd,p
MF-SA (Standard / Reduced Depth) NRd,p [KN] 1.2/0.6 1.6 2.4/1.6 3.3 5.0 6.6
o
Recommended pull-out resistance in Concrete C25/30 without spacing & edge Distance : N rec
MF-SA (Standard / Reduced Depth) NRec [KN] 0.9/0.4 1.1 1.7/1.1 2.4 3.6 4.7
o
V Rd,p, : Design shear resistance in Concrete C25/30 without spacing & edge Distance
MF-SA (Standard / Reduced Depth) VRd,p [KN] 1.2/1.2 2.5 4.5 7.3 8.7 10.7
Vrec : Recommended pull-out resistance in Concrete C25/30 without spacing & edge Distance
MF-SA (Standard / Reduced Depth) VRec [KN] 0.9 1.8 3.2 5.2 6.2 7.6
15
SLEEVE ANCHOR FOR NON-CRACKED CONCRETE
fck,cyl [N/mm2 ] 20 25 30 35 40 45 50
2
fck,cyl [N/mm ] 25 30 37 45 50 55 60
Spacing
M5 M6 M8 M10 M12 M16
s [mm]
35 0.72 / 0.82 0.69
40 0.75 / 0.87 0.72 0.66 / 0.72
45 0.78 / 0.92 0.75 0.68 / 0.75
50 0.80 / 0.96 0.78 0.70 / 0.78 0.68
55 0.84 / 1.00 0.80 0.73 / 0.80 0.70
60 0.87 0.83 0.75 / 0.83 0.72 0.69
70 0.93 0.88 0.79 / 0.88 0.75 0.72 0.69
80 1.00 0.94 0.83 / 0.94 0.79 0.75 0.72
90 1.00 0.87 / 1.00 0.82 0.79 0.75
100 0.91 0.86 0.82 0.78
120 1.00 0.93 0.88 0.83
140 1.00 0.95 0.89
150 1.00 0.91
180 1.00
smin
[mm]
80/55 90 120/90 140 160 180
hef [mm] 27/18 30 40/30 46 52 60
MULTIFIX makes recommendations for its product only, and the recommendations are not intended to supersede any relevant guideline or design code of practice
16
DROP-IN ANCHOR FOR NON-CRACKED CONCRETE
Description
MULTIFIX Drop-In Anchor is an internally threaded socket Anchor for use with bolts or
threaded rod of any length.
Application
Suspended services, stadium seating, holding down machinery, racking
light to medium duty fixing.
Features:
Thin walled-smaller drill sizes used.
Flush fitting-no protrusions when not in use
Shallow embedment – less chance of drilling into rebar, and faster drilling.
Permanent anchorage – removal of fixture leaves anchor undisturbed.
Technical Data
Tighten Design Design
Internal Effective
Anchor Fixture Drill Torque Tensile Shear
Product Threaded Threaded Setting
Length Hole Hole (fCU > Resistance Resistance
Code Size Length Depth
(mm) (mm) (mm) 20N/mm2 [KN] [KN]
(mm) (mm)
[Nm] C25/30 C25/30
MF-DA 06 M6 11 25 7 8 25 5 3.2 2.3
17
DROP-IN ANCHOR FOR NON-CRACKED CONCRETE
Characteristic loads, tension NRK,p [KN] 7.0 8.2 11.9 21.6 33.0 45.0
Characteristic loads, shear VRK,s [KN] 3.8 7.3 9.6 16.8 31.3 49.0
Concrete C25/30
Threaded
MF-DA (Inches) 1/4" 5/16" 3/8F|3/8” 1/2” 5/8” 3/4”
Diameter
Characteristic loads, tension NRK,p [KN] 7.0 8.2 8.2/11.9 21.6 33.0 45.0
Characteristic loads, shear VRK,s [KN] 3.8 7.3 9.6 16.8 31.3 49.0
Anchor size Threaded M6 | 1/4” M8 | 5/16” M10 | 3/8” M12 |1/2” M16 | 5/8” M20 |3/4”
MF-DA Steel 8.8 NRd,s 10.6 13.3 16.8 28.0 41.9 66.5
Steel 4.6 γMC = 2.0; Steel 5.8 & 8.8 (M6 – M12) γMC = 1.5; Steel 5.8 & 8.8 (M16 & M20) γMC = 1.6 [Acc EN ISO 898-1 Table 5]
18
DROP-IN ANCHOR FOR NON-CRACKED CONCRETE
o
1.2.1 Design pull-out resistance in Concrete C25/30 without spacing & edge distance : N Rd,p
Anchor size Threaded M6 | 1/4” M8 | 5/16” M10 | 3/8” M12 |1/2” M16 | 5/8” M20 | 3/4”
3.8/5.5
MF-DA NRd,p [KN] 3.2 5.0 10.0 15.3 20.8
hef : 30 / 40
Characteristic Spacing (3hef) scr [mm] 75 90 90/120 150 195 240
of
NRd,p = NRk / γMC 2.16
o
1.2.2 Design pull-out resistance in Concrete C25/30 with Minimum edge distance : N Rd,p
Anchor size Threaded M6 | 1/4” M8 | 5/16” M10 | 3/8” M12 |1/2” M16 | 5/8” M20 |3/4”
1.9/2.8
MF-DA NRd,p KN] 1.9 2.5 5.0 7.8 10.4
hef : 30 / 40
Characteristic Spacing (3hef) scr [mm] 75 90 120 150 195 240
1.2.3 Recommended pull-out resistance in Concrete C25/30 without spacing & edge distance : Nrec
Anchor size Threaded M6 | 1/4” M8 | 5/16” M10 | 3/8” M12 |1/2” M16 | 5/8” M20 |3/4”
2.7/3.9
MF-DA NRec [KN] 2.3 3.6 7.1 10.9 14.9
hef : 30 / 40
Characteristic Spacing (3hef) scr [mm] 75 90 120 150 195 240
fBN / fBv
Influence of concrete strength
Concrete Strength C20/25 C25/30 C30/37 C35/45 C40/50 C45/55 C50/60
fck,cyl [N/mm2 ] 20 25 30 35 40 45 50
2
fck,cyl [N/mm ] 25 30 37 45 50 55 60
fBN / fBV 0.90 / 0.90 1.00/1.00 1.00/1.10 1.00 /1.22 1.00/1.29 1.00/1.35 1.00/1.41
1.3 Design concrete cone resistance for single anchors Concrete C25/30 : NRd,c
o
NRd,c = N Rd,c . fBN . fAN . fRN
Anchor Size Threaded M6 | 1/4” M8 | 5/16” M10 | 3/8” M12 |1/2” M16 | 5/8” M20 | 3/4”
o
MF-DA N Rd,c [KN] 3.8 5.0 5.0/7.8 10.0 16.1 22.0
of
NRd,c = NRk,c / γMC 1.8
19
DROP-IN ANCHOR FOR NON-CRACKED CONCRETE
1.4 NRd: Design tensile resistance: NRd = min ( NRd,s ;NRd,p ; NRd,c )
20
DROP-IN ANCHOR FOR NON-CRACKED CONCRETE
MF-DA Steel
VRd,s 2.3 4.4 5.7 10.0 18.7 29.3
4.6
MF-DA Steel
VRd,s 4.0 5.5 5.8 16.8 25.2 40.0
5.8
MF-DA Steel
VRd,s 4.0 5.5 5.8 16.8 25.2 40.0
8.8
Steel 4.6 γMC = 1.67; Steel 5.8 & 8.8 (M6 – M12) γMC = 1.25; Steel 5.8 & 8.8 (M16 & M20) γMC = 1.33 [Acc EN ISO 898-1 Table 5]
Anchor size Threaded M6 | 1/4” M8 | 5/16” M10 | 3/8” M12 |1/2” M16 | 5/8” M20 | 3/4”
VoRd,cp
MF-DA 4.5 6.0 6.0/9.3 13.0 38.6 52.8
[KN]
Effective
anchorage hef [mm] 25 30 30/40 50 65 80
depth
V0Rd,c: design resistance for single anchors with edge distances cmin, C25/30
V0Rd,c = Concrete design edge resistance ( V0Rd,c = 0.45 . √dnom . (lf /dnom)0.2 . √fck,cube . C11.5 / γMC =1.5[N] (Multiply 1.4 for Non-cracked concrete)
Anchor size M6 | 1/4” M8 | 5/16” M10 | 3/8” M12 |1/2” M16 | 5/8” M20 | 3/4”
o
V Rd,c
MF-DA 2.3 2.6 2.7/4.5 6.9 12.2 17.8
[KN]
Minimum edge Cmin
45 45 45/60 75 100 120
distance [mm]
21
DROP-IN ANCHOR FOR NON-CRACKED CONCRETE
J
P1@uD4 ?]U[dT]RT ^U TSVT SXbcP]RT P]S b_PRX]V
h < 1.5 > C h < 1.5 > C
GX]V[T P]RW^a a a
^a Va^d_ P]RW^a fXcW b . -R \ \
_CR1V A
\fbg \fbg _CR1V A 63: 63:
\fbg \fbg
b
CV
8a 0 k a
7]RW^a _PXa fXcW b 4 -R _CR1V A 8\ 0 k \
_CR1V A 63: 63:
;\fbg \fbg ;\fbg \fbg
R
CW CW W
G+ G, G-}}}} G]|+
P1@uD
\ a
fbg
\fbg @ 63:\fbg
z zw{ zw} zw* zw, { {w{ {w} {w* {w, | |w{ |w} |w* |w, }
ASWQUO KWMRX[ r\ 0 ys +}** +}-+ +}00 ,}*, ,}.+ ,}2- -},0 -}1, .}+3 .}03 /},* /}1, 0},1 0}2- 1}.+ 2}**
nlu *}0, *}13 *}31 +}+0 +}-0 +}/2 +}2* ,}*. ,},2 ,}/. ,}2* -}*1 -}-/ -}0. -}3- .},-
nlv *}0- *}2* *}33 +}+2 +}-3 +}0* +}2- ,}*1 ,}-+ ,}/1 ,}2- -}+* -}-2 -}01 -}30 .},1
nlw *}0/ *}2, +}*+ +},* +}.+ +}0- +}2/ ,}*3 ,}-. ,}/3 ,}20 -}+- -}.+ -}1* .}** .}-*
o *}01 *}2. +}*- +},, +}.- +}0/ +}22 ,}+, ,}-0 ,}0, ,}23 -}+0 -}.. -}1- .}*- .}--
ols *}1/ *}3- +}+, +}-- +}/. +}11 ,}** ,},/ ,}/* ,}10 -}*- -}-+ -}0* -}23 .}+3 .}/*
p *}2- +}*, +},, +}.- +}0/ +}23 ,}+- ,}-2 ,}0- ,}3* -}+2 -}.0 -}1/ .}*/ .}-/ .}01
pls *}3, +}++ +}-, +}/. +}11 ,}** ,},/ ,}/* ,}11 -}*. -}-, -}0+ -}3* .},+ .}/, .}2-
q +}** +},* +}., +}0. +}22 ,}+, ,}-1 ,}0- ,}3* -}+2 -}.0 -}10 .}*0 .}-0 .}02 /}**
qls +}-* +}/, +}1/ +}33 ,},. ,}/* ,}10 -}*. -}-, -}0+ -}3+ .},+ .}/, .}2. /}+1
r +}0, +}20 ,}+* ,}-0 ,}0, ,}23 -}+1 -}.0 -}1/ .}*/ .}-0 .}02 /}** /}--
rls +}30 ,},+ ,}.1 ,}1. -}*, -}-+ -}0* -}3* .},* .}/, .}2. /}+1 /}/*
1WMRX[ YKS[
s ,}-- ,}/3 ,}21 -}+/ -}.. -}1. .}*. .}-/ .}01 /}** /}-- /}01
Ax3VSW
sls ,}1+ ,}33 -},2 -}/1 -}22 .}+3 .}/* .}2, /}+/ /}.3 /}2-
t ,}2- -}++ -}.+ -}1+ .}*, .}-- .}0/ .}32 /}-+ /}0/ 0}**
tls -},. -}/. -}2. .}+0 .}.1 .}2* /}+- /}.1 /}2, 0}+1
u -}01 -}32 .},3 .}0, .}3/ /},3 /}0- /}32 0}--
uls .}++ .}.- .}10 /}+* /}.. /}13 0}+. 0}/*
v .}/1 .}3+ /},/ /}/3 /}3/ 0}-* 0}01
vls /}*/ /}.* /}1/ 0}+* 0}.1 0}2-
w /},* /}// /}3* 0},0 0}0- 1}**
wls /}03 0}*/ 0}., 0}13 1}+1
on 0},+ 0}/2 0}3/ 1}--
onls 0}1. 1}+, 1}/*
oo 1},2 1}01
ools 1}2-
op 2}**
X]cTa\TSXPcT eP[dTb Qh [X]TPa X]cTa_^[PcX^]
CbS JbS
9^\QX]TS cT]bX^] P]S bWTPa [^PS4 z < 1.2
CFS JFS
MULTIFIX makes recommendations for its product only, and the recommendations are not intended to supersede any relevant guideline or design code of practice
22
SLEEVE ANCHOR
Description
MULTIFIX O-Hook Sleeve Anchor is a multipurpose
Fastening system use for all kinds of light duty
Hanging fixings
Application
Suspended ceilings, Hanging Signboard, Banner and temporary safety Barrier
Features:
Quick Fixing
Easy Removable upon dismantling
TECHNICAL DATA
Ring
Ring Ring Inner Drill Hole x
Threaded Outer Depth
Product Code Thickness Diameter depth
Size Diameter (mm)
(mm) (mm) (mm)
(mm)
MF-SA08045OH M6 4.5 20 10 8 x 45 45
Recommended Recommended
Characteristic Characteristic
Anchor size (Nrec) (Vrec)
Tensile Load [KN] Shear Load [KN]
Tensile Load [KN] Shear Load [KN]
MF-SA08045OH 11.0 2.2 11.0 2.2
NRec and VRec γmc = 5.0 included
23
WEDGE ANCHOR
MULTIFIX Tie Wire Wedge Anchor is a Light duty with small anchor spacing and edge
distances. Time saving through fastening installations, no special drilling and setting tools
are required.
Features:
Tie Wire Wedge Anchor is a complete unit ready to install system for through
fixing: no marking out and repositioning
True dimension anchor: hole size, anchor diameter all the same diameter
Anti-Rotation lugs
Application
Light duty anchoring in non-cracked concrete ideal for wire suspension works
Drill Hole to recommended Clean hole thoroughly with Insert Anchor and setting Anchor ready fixing depth
brush and blow clean. with hammer
24
NYLON ANCHOR
Description
MULTIFIX Nylon Anchor is the accepted method of light weight screw fixing into
solid material
Application
Timber battens, skirting boards, signs; electrical fitting; brackets
Suitable for external flashing, due to pull down feature.
Features:
Fully assembled through fixing.
Installed with hammer or screwdriver which drives homes the expander screw nail to give strong fixing in
a variety of solid materials.
Philips head cross slot provides additional pull down or complete removal with a screwdriver.
Large diameter head provides greater pullover strength.
Collapsible sleeve allows fixture to be pulled down firmly.
MULTIFIX makes recommendations for its product only, and the recommendations are not intended to supersede any relevant guideline or design code of practice
25
NYLON ANCHOR
TECHNICAL DATA Recommended Load LRec [KN] Brick & Lightweight Block
Tensile Shear Tensile
Effective Shear VRec
Fixture Anchor Drill Load Load Load NRec
Ø Fixture Setting [KN]
Thickness Length Hole NRec [KN] VRec [KN] [KN]
Product Code Anchor Hole Depth
da I do
Size (mm) hef Light-weight Light-weight
(mm) (mm) (mm) Brick Brick
(mm) Block Block
26
MULTI-FIX FASTENERS PTE LTD
Block 211 Woodlands Ave 9
#04-70/71 Woodlands Spectrum II
Singapore 738960
Tel : (65)68770408
Fax : (65)68770456
Email: sales@multifix.com.sg
Website: www.multifix.com.sg
Note: Only the contents printed in this catalogue are valid at the time of print and subject to further modifications without prior notice.
We do not accept liability for printing mistakes or omissions. Updated & Printed in April 2012