SCP1 panel shed_R01

Part Item Description Grade( Min.Yeild) Min. Coating Qty Total Quantity Length Weight Total WT
No mm kg/m kg
COLD FORMED SECTIONS
1 Column-1 :- SHS 100X100X4 YST310 PAINTED 2 2 4298 11.73 100.83
2 Column-2 :- SHS 100X100X4 YST310 PAINTED 2 2 4034 11.73 94.64
3 Stiffner plate :- 70X70X5 YST310 PAINTED 16 16 0.44 7.04
4 Rafter :-RHS 60X40X2.9 YST310 PAINTED 2 2 3289 4.12 27.10
5 Rafter connecting plate :- 250X250X8 E250 PAINTED 8 8 3.93 31.40
6 Seat plate 250x22x8 E250 PAINTED 8 8 0.17 1.37
7 Purlin - ISMC 75 E250 PAINTED 3 3 4350 6.80 88.74
8 0.6mm Trapazoidal Galvalume roof sheet(3340x4350) YST 240 PAINTED 1 1 - - -
9 CLEAT :- 50x50x5 full weld with purlin &Rafter E250 PAINTED 6 6 80 3.80 1.82
10 GI sheet for Gutter(1000x4350) YST 240 PAINTED 1 1 - -
11 5MM THICK Rafter packing plate E250 PAINTED 4 4 0.09 0.38
12 M12 Sag rod E250 PAINTED 2 2 1663 0.89 2.95
Hex Bolts (SS304 )Washer(SS304 )
i M16 bolt for column to rafter fixing(Nut+2PW+SW) 16 16 55 0.18 2.91
ii M12 sag rod (Nut+2PW) 5.6 grade(HDG) 4 4
iii self drilling screw 5.6 grade(HDG) 45 51 65
Total structural weight (Ton) 0.3592

Note:- 1) Hex Bolt specification refe DIN 933, Plain washer specification refe DIN 125, Wide washer specification refe DIN 9021, Spring washer specificaition refer DIN 127, Hex nut specificaition