22KMM502

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

CHANGE

PERFORMANCE FOR 1 STAGE EFFICIENCY AS


NUMBER OF FOR NUMBER

TORRENT PUMPS
POINT OF STAGE
TYPE..........22.....KMM............ FOLLOWS
LOWER 2 1
R.P.M...........1460...................…. DEEP WELL VERTICAL TURBINE PUMPS
LOWER 1 2
CURVE SHEET No..22-0502 O.D. BOWLS 205/8" K=32,0
48 20

NPSH(m)
16
NPSH=f(Q)
DETRITUS WITH NO SUCTION LIFT AND TEMPERATURE NOT TO EXCEED 30C .

46 12
HYDRAULIC PERFORMANCE : IS CONTINGENT ON WELL FURNISHING PUMP

8
ο
WITH CLEAR FRESH NON-AERATED OR NON-GASEOUS WATER FREE FROM

44 4
42
40
38
36
34

GREEK CONSTRUCTION
32 H=f(Q)
TOTAL HEAD IN METERS

30
28
26
24
22
20
18
16 n=f(Q)

Efficiency(%)
85
14
80
12
10 75
8 70
6
4 N=f(Q)

N(PS)
2 200
150
0 100

0 200 400 600 800 1000 1200 1400 1600 1800


CUBIC METERS PER HOUR

NO COLUMN LOSSES ARE INCLUDED EMMANUEL N. KAZIS S.A.


IMPELLER BRONZE
P.O Box 52835 - GR 14610 - N. ERYTHREA - ATHENS - GREECE
TEL: (01)8161702 - (01)8161712 - FAX: (01) 8134765 - (01) 8161018
CLOSED
TOLERANCES ISO-2548 CLASS C E-Mail : kazis@hol.gr STAINLESS STEEL SHAFT