TOTAL DEFLECTION L/250 IN SAFE 12

COMB-250-1 DL+SDL+LL CRACKED


COMB-250-2 DL+SDL+0.2LL CRACKED
COMB-250-3 DL+SDL+0.2LL CRACKED + LONG-TERM
LOAD COMBINATION
L/250 = 1 – 2 + 3

Total Deflection δTL= δD + λ∞δD + δL + λ∞δ0.2L

LONG-TERM DEFLECTION L/500 IN SAFE 12


(This is normally referred to as deflection that happens after installing partitions)
COMB-500-1 DL+SDL+0.2LL CRACKED
COMB-500-2 0.4SDL+LL CRACKED
COMB-500-3 DL+SDL+0.2LL CRACKED + LONG-TERM
LOAD COMBINATION
L/500 = -1 + 2 + 3

Long-term Deflection δTL = δ0.4SDL + λ∞ (δDL + δSDL) + δLL + λ∞δ0.2LL

ASSUMPTION IS THAT 60% OF SDL WILL BE APPLIED BEFORE CONNECTING


PARTITIONS. 20% OF LIVE LOAD IS CONSIDERED AS SUSTAINED.
ASSIGNING REINFORCEMENT TO SLABS IN SAEF 12

FOR ASSIGNING UNIFORM REINFORCEMENT PERFORM THE FOLLOWING


FOR ADDITION REINFORCEMENT IN CERTAIN AREAS PERFORM THE
FOLLOWING
TO USE THE REINFORCEMENT THAT HAS BEEN SPECIFIED PREVIOUSLY DO
THE FOLLOWING
CHOOSE THE FOLLOWING OPTIONS TO PERFORM A CRACKING ANALYSIS OF
THE SLAB.