General information / preparation

Setting up the network configuration and parameters


Quick Guide for GSD available at www.festo.com/fieldbus
GSD with parameters for CPX modules and valve terminals
CPX-FB13 Profibus-DP connected to
various PLC like:
S7-300 Documentations with detailed descriptions are
available at the Festo Support Portal.
Go to www.Festo.com (Support -> Support and Downloads)

Search for:
CPX-FB13 (Profibus-DP manual): EN - 526428
CPX-SYS (CPX system manual): EN – 526446

Additional information about Profibus can be found on:


 www.profibus.com

Start-up hardware settings Using STEP7 for Profibus


1 Operating mode: No function,
reserved
2 Hardware configuration

Default

Remote When FEC,CEC


I/O integrated

Diagnostic

Bus-
address
1 … 125

Configuration with Using LED’s for the


3 STEP7 4 identification of device status
Profibus-DP network status
1. Copy the GSD of the valve terminal into the directory ...\STEP7\S7Data\GSD on
your PC/programmer. Bus Failure Ok
2. Copy the icon files for the CPX terminal into directory ...\STEP7\S7DATA\NSBMP
Field bus connection isn’t ok
on your PC or programmer.

3. Insert a DP master system: - Right−hand mouse click on "DP "under "CPU".

4. Open the following folder in the hardware catalogue: "\PROFIBUS−DP\Additional


Field devices\Valves". Pull the station type "FESTO CPX−Terminal" onto the line
of the DP master system. The dialogue window "Properties _ PROFIBUS interface" CPX hardware status
will be displayed.
System failure OK
5. Select the PROFIBUS address identical to the selected setting on the DIL switch. Information
6. Open the module "FESTO CPX−Terminal"(folder\PROFIBUS−DP\Additional Field
Diagnostic
Devices\Valves\...) in the hardware catalogue. Hardware defect
Power system / load Power OK
7. Pull the first (left−hand) module of your CPX terminal onto line 0 in the Outside tolerance
configuration table. Repeat this step with further modules of your CPX terminal. Modify status OK
Saved parameters
See manual CPX-FB13 chapter “Commissioning” for more details Force active

Festo AG & Co KG Quick Guide for CPX-FB13 Version A4


Mapping Alternative diagnose
Tip Tip
The “Status bits” are 8 major signals which can be considered inside the
PLC program. They are accessed via the optional “Strobed connection”

Bit Diagnostic information Description


----------------------------------------------------------------------------------------------
0 Fault at valve Module type on which
1 Fault at output a fault has occurred
2 Fault at input
3 Fault on analogue/function module
Location Module DP identifier Input Output ----------------------------------------------------------------------------------------------
Siemens address address 4 Under voltage Type of fault
0 Field bus node (FB13) 64 42 - 5 Short circuit/overload
1 Digital 8-input module 8DI 43 - 6 Wire fracture/open load
2 Digital 8-input module 8DI 44 - 7 Other faults
3 Digital 4-output module 4DO - 42 ----------------------------------------------------------------------------------------------
4 Digital multi I/O module 8DX 45 43 Additional and advanced diagnostics can be read out with:
5 Digital 4-output module 4 DO - (42)* - Online-Mode of S7
6 CPA pneumatic Interface 16DO - 44 - Handheld unit CPX-MMI
*) Identifiers can be grouped together - USB adapter/ Ethernet with CPX-FMT software

See manual CPX-FB13 chapter “Commissioning” for more details See manual CPX-FB13 chapter “Diagnosis” for more details

Installation Changing GSD size


Tip Tip
Screening The GSD file size is around 220KB. Some PLC memory cards have in total
- Correct screening at each connector only 256KB. It could happen that the size of the GSD file is too big. In order
- The cable screen should be connected to to decrease the size proceed according follow steps.
ground at both ends of the cable
1. Open GSD file e.g. CPX_059.GSD with an Editor

2. Scroll down to “Modultypen”

Potential equalization 3. Mark the modules which are not needed (e.g. CPI modules)
The cross-section of the
potential equalization cable
should be chosen with regard
to the maximum potential
equalization currents which
can flow.

Note:
A good Installation is necessary
for a trouble-free operation 4. Delete and save the file

IDLE and Fault Mode Diagnostic integration


Tip Tip
FAULT mode: Diagnostics
Defines the status of output
signals during a network failure -Diagnostic data and parameters are
when connected to a running PLC usually also integrated into the GSD
files and are read out in online mode
The default setup defines all of configuration tools like “Step7” or
output signals to the OFF can be interpreted by PLCs.
state during one of the modes
-16 pre-defined failure types.
An optional channel based setup
can be made: -Advanced diagnostics may be
Value to OFF (default) Integrated into the PLC with
Value to ON the use of OB82 and OB86
Hold Last State function blocks.

Diagnostic information is structured in


- Device oriented diagnostic
- Module oriented diagnostic
- Channel oriented diagnostic

See manual CPX-FB13 chapter “Diagnosis” for more details

Festo AG & Co KG Quick Guide for CPX-FB13 Version A4