PO Box 18448
Dubai Investment Park
Near Green Community
Dubai, UAE
www.keesafety.com
T +971-4-8859066
F +971-4-8859065
E sales@keesafety.ae
Kee Line is a horizontal life line system tested to the requirements of EN 795CLASS C
Kee Line is a 8mm Gr. 316 stainless steel wire system with electro polished brackets, detachable travellers
& powder coated posts & base plates that provides flexible, continuous protection for multiple users
working at height
ENERGRY ABSORBER MILD STEEL GR. Q235 45 MICRONS MIN. POWDER COATING
PART: E1 Q'TY:
G TH
LEN
N
SPA
49 mm
CNR-90 I CNR-90
ENERGY ABSORBER
INTERMEDIATE
I CNR-90 SWAGE TENSIONER
EXTREMITY POST POST & BRACKET ASSEMBLY
E1 SWAGE TERMINAL
END OF SYSTEM
KEELINE BASE
SET SCREW
FOR APPROVAL
2X EACH CLAMP 3/8-24 x 0.8" CLIENT:
ROUND POINT
KS-KL-S5-0001 0
This drawing is the property of Kee Safety L.L.C. It is supplied
on loan in confidence and must be returnd immediately on
BASEPLATE - SPS10: 536 X 380mm X 3mm THICK request. No part of the drawing may be copied or
reproduced in any way, nor may the information or design
EXTREMITY POST-LAPSTEX10 BASEPLATE - SPS10: 536 X 380mm X 3mm THICK BASEPLATE - SPS10: depicted be disclosed without the prior written consent of the
owner. All rights reserved.
(200 X 100 X 85mm) 536 X 380mm X 3mm THICK
EXTREMITY POST-LAPSTEX10
HEX BOLT M12X30- TORQUE VALUE 39Nm (200 X 100 X 85mm) INTERMEDIATE POST-LAPSTIC10
W/ NYLOC NUT & WASHER (150 X 100 X 85mm)
IN-LINE ENERGY ABSORBER-LASORBER10 HEX BOLT M12X30- TORQUE VALUE 39Nm
W/ NYLOC NUT & WASHER HEX BOLT M12X30-
(265X110X85mm) TORQUE VALUE 39Nm
IN-LINE ENERGY ABSORBER-LASORBER10
HEX BOLT M12X60-TORQUE VALUE 39Nm W/ NYLOC NUT & WASHER
(265X110X85mm)
W/ NYLOC NUT & WASHER
SWAGE TERMINAL HEX BOLT M12X60-TORQUE VALUE 39Nm
W/ NYLOC NUT & WASHER
(LINE-SWAGE-185mm)
STATUS:
WIRE ROPE IWRC 7X7,8mm Ø8mm, 7X7 IWRC CONTRUCTION STANDARD DETAIL-KEELINE
C90&C135 -CORNER BRACKET 90°&135° CLIENT:
PROJECT:
200,00
TITLE:
KEELINE COMPONENT
KEELINE SYSTEM, HAS BEEN VERIFIED VIA PHYSICAL TESTING AND HAS BEEN APPROVED STANDARD DETAIL
536,00
BY INDEPENDENT TEST HOUSE
SCALE: DATE: DRAWN: CHECKED:
1:1 25-09-15 RW RN
TYPICAL ELEVATION DRAWING NO:
KS-KL-STD-000001
REVISION:
0
This drawing is the property of Kee Safety L.L.C. It is supplied on loan in confidence
and must be returnd immediately on request. No part of the drawing may be
LOAD TEST TABLE KEE LINE MATERIAL SPECIFICATION copied or reproduced in any way, nor may the information or design depicted be
disclosed without the prior written consent of the owner. All rights reserved.
LOAD TEST (NORMAL TO SEAM) - SAFETY FACTOR of 2 UPRIGHT POST: PART: EXT-TEN Q'TY:
MATERIAL: MILD STEEL GRADEQ235
MODEL PANEL NAME THICKNESS OF SCREW ULTIMATE FAILURE ALLOWABLE I (INTERMEDIATE BRACKET)
KEELINE BASE GALVANISING: 45 MICRONS MIN.
MATERIAL TENSION (Nm) (kNs) MODE (kNs)
FINISH : POWDER COATING, RAL 9023
HEX FLANGE BOLT 4X - M10 S-5-Z KALZIP 1.27 mm ALUM. 13 10.869 kN C/D 9.80 kN
S5-Z CLAMP 4X BRACKET:
MATERIAL: 316 STAINLESS STEEL
S-5 CLAMP FAILURE MODE LEGEND: FINISH : ELECTRO POLISHED
SET SCREW (A) - DISENGAGEMENT OF CLAMP FROM PANEL SEAM ENERGY ABSORBER:
2X EACH CLAMP 3/8-24 x 0.8" (B) - CLAMP DISPLACEMENT OF A DISTANCE OF MORE THEN 8mm (0.315") MATERIAL: MILD STEEL GRADEQ235
(C) - BREAKAGE OR FRACTURING OF CLAMP OR FASTENERS PART: INT-STD Q'TY:
ROUND POINT GALVANISING: 45 MICRONS MIN.
(D) - STRIPPAGE OF THE CLAMP SET SCREWS FINISH : POWDER COATING, RAL 9023 CNR CNR (CORNER 90DEG./135DEG)
(E) - FRACTURING OF ANY AREA OF PANEL SEAM 90 135
STANDING SEAM ROOF (F) - BUCKLING OR ANY OTHER STRUCTURAL OR SEVERE COSMETIC DAMAGE TO TENSION INDICATOR:
PANEL SEAM MATERIAL: 316 STAINLESS STEEL
SWAGE ASSEMBLY:
THIS TABLE REPRESENTS TENSILE LOADS APPLIED TO THE CLAMP IN A DIRECTION
MATERIAL: 316 STAINLESS STEEL
PARALLEL AND NORMAL TO THE PANEL SEAM.
PANEL MUST BE ADEQUATELY ATTACHED TO THE STRUCTURE AT THEIR POINT OF FIXITY
TO RESIST THESE LOADS. SWAGE FIXING BRACKET:
ALLOWABLE LOADS ARE LISTED UTILIZING A DEFAULT FACTOR OF SAFETY (FS)=2.0. MATERIAL: 316 STAINLESS STEEL PART: CNR90 / CNR135 Q'TY:
TABLED VALUES ARE DEPENDENT UPON SETSCREW TENSION. LOAD TESTING OF S-5! WIRE ROPE: E-I (EXTENDED INTERMEDIATE)
CLAMPS IS CONDUCTED WITH SETSCREWS TENSIONED AT 150 LBS. OR 115 LBS. MATERIAL: GR. 316 STAINLESS STEEL
SETSCREWS SHOULB BE TENSIONED AND VERIFIED USING A CALIBRATED TORQUE Ø8mm, 7X7 IWRC CONSTRUCTION
WRENCH. (160 & 180 LBS. FOR 22ga STEEL AND 130&150 LBS. FOR ALL OTHER METALS).
EXPLODED VIEW KEELINE HORIZONTAL LIFELINE SYSTEM STANDARD MANUAL In ACCORDANCE IN BS EN 795
NUMBER OF USER
Scale 1:4 NO. OF USER MAXIMUM SPAN BETWEEN POST NO.'s FIXING PER
PART: INT-EXT Q'TY:
TYPE OF ROOF
FALL ARREST FALL RESTRAINT FALL ARREST FALL RESTRAINT BASE PLATE E2 (END OF SYSTEM)
>0.7mm PROFILED 2 3 15 10 8 RIVETS
STEEL SHEET
>0.5mm, <0.7mm 2 3 15 10 16 RIVETS
PROFILED STEEL SHEET
MEMBRANE 2 3 15 10 4 TOGGLE FIXINGS
STEEL/TIMBER DECK
MEMBRANE 2 3 15 10 4 STUD RESIN
M12 TORQUE VALUE 39 Nm PART: EXT-SW Q'TY:
CONCRETE DECK CAPSULES
ENERGY ABSORBER 4 STANDING SEAM WIRE ROPE - SS316
M12 TORQUE VALUE 39 Nm STANDING SEAM 2 3 15 10
CLAMP
SWAGE TENSIONER ASSEMBLY
COMPOSITE 15 10 16 RIVETS
SWAGE TERMINAL 2 3
4 STUD RESIN PART: ROPE8SS7X7 Q'TY:
CONCRETE 2 3 15 10
CAPSULES
CL OF WIRE STRUCTURES BRICK, A40-80 SET SCREW +
CONCRETE, STEEL 15 NUT / SOCKET RESIN
2 3 10
WORK CAPSULES
S5-Z CLAMP
2x ROUND POINT TYPE SET SCREW
3/8-24x0.80" CL OF WIRE 0 INITIAL ISSUE RW 27/09/15
Scale 1:5
KS-KL-S5-Z-0001 0