NOTE PLAN HISTORY

SHIP CHK.
DATE REV. DESCRIPTION CHK. APP.
NO. DWN.
2016.01.06 S3090 - ISSUED FOR FINAL

HULL NO. IMO NO.


S3087 9712292
S3088 9712307
S3089 9712319
S3090 9712321
S3091 9726475
S3092 9726487 TOTAL ( 9 ) SHEETS WITH A COVER
This drawing or document is the property of SSME and must not be partially or wholly copied and used for
any other purpose without prior written permission of SSME.
SHIP NO. SHIP TYPE
S3087/88/89/90/91/92 50,000 DWT CLASS PRODUCT OIL/CHEMICAL TANKER
DEP'T ACCOMMODATION DESIGN PART
TITLE :
APP. BY S.C.CHOI TEL: 6619

CHK. BY W.S.YEA TEL: 6621 MECH., NATURAL VENT &


CHK. BY - TEL: - AIR CON. DUCT DIAGRAM
DWN. BY K.B.OH TEL: 6653
DWG NO. SCALE
File Name :

SUNGDONG
Shipbuilding & Marine Engineering DATE
200A423001AB NONE

2016.01.06
210X297 Sungdong Shipbuilding & Marine Engineering Co., Ltd. D310-401-00
PAGE 01 / 08

1. CONTENTS 2. GENERAL NOTE HULL NO.


DWG. NO.
S3087/88/89/90
S3087/88/89/90/91/92
200A423001AB

GENERAL NOTE
1. VENTILATION DUCT FOR GALLEY IS TO BE PROVIDED INDEPENDENTLY FROM THESE FOR
ACCOMMODATION SPACE, SERVICE SPACES AND CONTROL SPACES.
NOTE DESCRIPTION PAGE
2. FOR DETAIL DRAWINGS OF VENTILATOR HEADS AND WEATHERTIGHT CLOSURES,
PLEASE REFER TO "PIPE & HVAC STANDARD PRACTICE FOR ACCOMM."(DWG. No. 200A241001AB)

1. COVER & PLAN HISTORY ------------------------------- 0


3. FOR DETAIL DRAWINGS OF DUCT PENETRATION PIECES PASSING THROUGH
"A" CLASS BULKHEADS OR DECKS, PLEASE REFER TO "FIRE PROTECTION, DECK COVERING &
2. CONTENTS -------------------------------- 1 INSULATION PLAN" (DWG. No. 200A532001AB)

3. GENERAL NOTE -------------------------------- 1 4. SUPPLY AIR FOR THE HOSPITAL IS TO BE ISOLATED FROM MAIN DUCT BY NON-RETURN FLAPS.
EXHAUST AIR FOR THE HOSPITAL IS TO BE DIRECTLY CONDUCTED TO THE OPEN AIR WITH
4. HVAC. SPEC. CODE STRUCTURE ------------------ 2 MECHANICAL EXHAUST FAN.

5. ABBREVIATION & SYMBOL LIST ------------------ 2 5. THE SMOKE DAMPERS ARE TO BE PROVIDED FOR THE WHEEL HOUSE AND FIRE CONTROL STATION
IN ORDER TO PREVENT SMOKE THROUGH AIR SUPPLY DUCTS.
6. AIR BALANCING TABLE ---------------------------- 3
6. THE START/STOP PANELS FOR THE VENT. FANS OF ACCOMM. SPACE ARE TO BE PROVIDED
7. SPECIFICATION OF MECH. VENT. FAN ------------------ 3 AT LOCAL POSITION AND EACH ONE(1) SET OF EMERGENCY PUSH BUTTON IS TO BE
PROVIDED AT THE WHEEL HOUSE AND THE FIRE CONTROL STATION.
8. DUCT DIAGRAM FOR UPPER DECK ------------------- 4 ALSO, THE FANS TO BE AUTOMATICALLEY STOPPED WHEN FIRE ALARM IS ACTIVATED.

9. DUCT DIAGRAM FOR A DECK ---------------------- 5 7. FOR THE AIR RECIRCULATION TO AIR HANDLING UNIT DURING NORMAL OPERTION CONDITION,
THE DOOR BETWEEN STAIRWAY AND PASSAGE WILL BE OPEND AND BE AUTOMATICALLY CLOSED
10. DUCT DIAGRAM FOR B DECK ---------------------- 6 WHEN FIRE ALARM IS ACTIVATED.

11. DUCT DIAGRAM FOR C DECK ---------------------- 7 8. AIR IN AIR CONDITIONING SPACES TO BE EXHAUSTED INTO PASSAGE AND TOILET THROUGH
THE DOOR LOUVER OR UNDER GAP OF TOILET DOOR.
12. DUCT DIAGRAM FOR NAV. DECK ---------------------- 8
9. THE AIR IN PASSAGE TO BE RECIRCULATED TO THE A.H.U THROUGH STAIRWAY.

10. STAIRWAY ENTERANCE DOORS EXCEPT WHEELHOUSE SHALL BE NORMALLY OPEN


BY ELEC.MAGNETIC HOLDER.

11. VENTILATOR COAMING HEIGHT TO BE DECIDED ACCORDING TO INTERNATIONAL CONVENTION


OF LOAD LINE 1966.

12. WHERE A THIN PLATED DUCT WITH A FREE CROSS SECTIONAL AREA EQUAL TO, OR LESS THAN 0.02㎡
PASSES THROUGH "A" CLASS BULKHEADS OR DECKS, THE OPENING SHALL BE LINED WITH A STEEL
SHEET SLEEVE HAVING A THICKNESS OF AT LEAST 3 mmAND A LENGTH OF AT LEAST 200 mm.

13. THE SLEEVE FOR VENTILATION DUCTS WITH A FREE CROSS-SECTIONAL AREA EXCEEDING 0.02㎡
PASSING THROUGH "A"CLASS BULKHEAD OR DECKS SHALL HAVE A THICKNESS OF AT LEAST 3mm

200A423001AB-VDIA
AND A LENGTH OF AT LEAST 900mm.

14. VENTILATION DUCTS WITH A FREE CROSS-SECTIONAL AREA EXCEEDING 0.02㎡ PASSING THROUGH "B"
CLASS BULKHEADS SHALL BE LINED WITH STEEL SHEET SLEEVES OF 900mm IN LENGTH DIVIDED
PREFERABLY INTO 450mm ON EACH SIDE OF BULKHEADS UNLESS THE DUCT IS OF STEEL
FOR THIS LENGTH.

File Name :
A3(420X297) Sungdong Shipbuilding & Marine Engineering Co., Ltd. D310-303-00
PAGE 02 / 08

3. HVAC. SPEC. CODE STRUCTURE 4. ABBREVIATION & SYMBOL LIST HULL NO.
DWG. NO.
S3087/88/89/90
S3087/88/89/90/91/
92200A423001AB

HVAC SPEC. CODE STRUCTURE S P R Z X CERTIFICATION (NON CERT.)


PRESSURE (OTHERS)
SYMBOL DESCRIPTION SYMBOL DESCRIPTION
S=STANDARD PIPE MATERIAL
PRE-INSULATED SPIRAL DUCT LOUVER VENTILATOR WITH COVER
HVAC MATERIAL(STANDARD) (AIR CON. & NATURAL SUPPLY) LV-XX XX : SIZE (LV-33 : 300 X 315)
N.D
4A-10A

UN-INSULATED SPIRAL DUCT

1200A
AXIAL FLOW FAN W/MUSHROOM VENT

200A

400A

450A

600A
650A
250A

300A
350A

500A
125A

160A
100A
M

50A
32A

40A
15A

65A

80A
CODE
SPR 0.5T GALV'D STEEL SHEET (PRE-INSULATION) (SANITARY & NATURAL EXHAUST) MF-XX XX : SIZE
SUR 0.5T GALV'D STEEL SHEET (UN INSULATION)
MUSHROOM VENTILATOR WITH COVER
SAP SPP ERW DUCT SIZE RECTANGULAR DUCT XX : SIZE
MV-XX
A-60 INSULATION
CEILING GRILL
DIMENSION AND WEIGHT OF SPIRAL DUCT A-60 CLASS FIRE INTEGRITY DUCT
MLG-XX XX : SIZE
PREINSULATED SPIRAL DUCT UNINSULATED SPIRAL DUCT
50T THERMAL INSUL.
NOM. EFFECTIVE PENE. LENGTH EFFECTIVE AUTOMATIC & MANUAL FIRE DAMPER FOR AIR TERMINAL
DIA. OUT. DIA
SECTIONAL
WEIGHT OUT. DIA
SECTIONAL
WEIGHT PENE. LENGTH 50T THERMAL INSULATION
(mm) AREA (㎡) (kg/M) (mm) (mm) AREA (㎡) (kg/M) (mm) FB-XX XX : SIZE
80 118 0.005 3.3 200 84 0.005 1.16 200
WALL MOUNTING AL - GRILL
100 138 0.008 4.2 200 104 0.008 1.62 200 DUCT PASSING THROUGH FLOOR DECK
WG-XX
XX : SIZE
125 163 0.012 4.7 200 129 0.012 2.0 200
MS25-C01 MS35-C01
160 198 6.0 200 164 2.4 CEILING MOUNTING ROOM UNIT
0.019 0.019 200
DUCT PASSING THROUGH OVERHEAD DECK
200 238 0.031 7.3 200/900 204 0.031 3.0 200/900
(MS25-C01, MS35-C01)
250 288 0.049 12.6 200/900 254 0.049 4.0 200/900 MS25-P00 MS35-P00
CEILING MOUNTING ROOM UNIT
DUCT PASSING THROUGH FLOOR & OVERHEAD DECK
(MS25-P00, MS35-P00)
DIMENSION AND WEIGHT OF ROUND DUCT MLG-55 MLG-90
GRILL WITH MOUNTING BOX
RECTANGULAR DUCT DOWN
TYPE
DIAMETER(mm)
THICKNESS(mm) WEIGHT(Kg/m) EFFECTIVE SECTIONAL AREA(m )
2 (MLG-55, MLG-90)
INSIDE OUT SIDE
SP8 81 89.1 4.05 STEEL PIPE(SPP-80A) 8.49 0.005 DECK MOUNTING TYPE ROOM UNIT
RECTANGULAR DUCT UP
SP10 105.3 114.3 4.50 STEEL PIPE(SPP-100A) 12.2 0.009 MS40-B01 (TYPE : MS40-B01)
SP12 130.1 139.8 4.85 STEEL PIPE(SPP-125A) 16.1 0.013
PUNKER LOUVER
SP16 155.5 165.2 4.85 STEEL PIPE(SPP-150A) 19.2 0.019 RECTANGULAR DUCT UP & DOWN
PK-6 (TYPE : PK NO.6 )
SP20 204.8 216.3 5.85 STEEL PIPE(SPP-200A) 30.4 0.033
SANITARY EXH. NOZZLE
SP25 254.6 267.4 6.40 STEEL PIPE(SPP-250A) 41.2 0.051 AUTOMATIC & MANUAL FIRE DAMPER FOR DUCT
SP30 304.5 318.5 7.00 STEEL PIPE(SPP-300A) 53.8 0.073
F.D F.D KU-100 KU-160 (KU-100, KU-160 )
SOD SOD
SP35 340.4 355.6 7.60 STEEL PIPE(SPP-350A) 65.2 0.091
VOLUME DAMPER & SMOKE DAMPER SHUT OFF DAMPER
V.S.D

AIR CON. SUPPLY VOLUME &


PENETRATION PIECE FOR PRE-INSULATED SPIRAL DUCT V.D

S.D
VOLUME DAMPER SMOKE DAMPER
xxx
xx.x
AIR CHANGE
DIAMETER(mm)
TYPE THICKNESS(mm) MATERIAL WEIGHT(Kg/m) REMARK
INSIDE OUT SIDE 1) xxx
2) xxx 1) SANITARY EXHAUST VOLUME & AIR CHANGE
NON-RETURN FLAP CLOSING DAMPER
PG8 109.8 114.3 4.5 STEEL PIPE (STPG38) 0.66 A/B - CLASS N.R.F C.D xx.x xx.x 2) SUNDRY EXHAUST VOLUME & AIR CHANGE
PG10 134.85 139.7 4.85 STEEL PIPE (STPG38) 0.84 A/B - CLASS
xxx
PG12 154.7 159.0 4.3 STEEL PIPE (STPG38) 0.94 A/B - CLASS DUCT FAN xxx MECH. SUPPLY VOLUME & AIR CHANGE
PG16 188.4 193.7 5.3 STEEL PIPE (STPG38) 1.20 A/B - CLASS

A/B CLASS : 900mm xxx


PG20/PGL20 235.8 245.0 9.2 STEEL PIPE (STPG38) 1.46/6.57 REDUCER xx.x MECH. EXH. VOLUME & AIR CHANGE
PG25/PGL25 311.5 318.5 7.0 STEEL PIPE (STPG38) 2.52/11.3 A/B CLASS : 900mm

CENTRIFUGAL FAN A-CLASS DOOR


PENETRATION PIECE FOR UNINSULATED SPIRAL DUCT
TYPE
DIAMETER(mm)
THICKNESS(mm) MATERIAL WEIGHT(Kg/m) REMARKS
AIR FLOW THROUGH DOOR GAP B-CLASS DOOR

200A423001AB-VDIA
INSIDE OUT SIDE
G8 84.85 88.9 4.05 STEEL PIPE (STPG38) 0.23 A/B - CLASS

G10 108.3 114.3 6.0 STEEL PIPE (STPG38) 0.32 A/B - CLASS AIR FLOW THROUGH DOOR VENT NON-CLASS DOOR
G12 133.1 139.7 6.6 STEEL PIPE (STPG38) 0.40 A/B - CLASS
PR-12 DUCT SIZE
G16 165.8 171.0 5.2 STEEL PIPE (STPG38) 0.48 A/B - CLASS D.T DRYING TUMBLER
G20/GL20 210.9 219.1 8.2 STEEL PIPE (STPG38) 0.60/2.70 A/B CLASS : 900mm PREINSULATED ROUND DUCT SPEC.
G25/GL25 257.7 267.0 9.3 STEEL PIPE (STPG38) 0.80/3.60 A/B CLASS : 900mm UR-12 DUCT SIZE
AXIAL FLOW FAN

File Name :
UNINSULATED ROUND DUCT SPEC.
DTH03-400
DUCT HEATER DTH03-400 : 4 KW RDG-1 & RDG-2
DUCT HEATER DTH03-500 : 5 KW ROUND DUCT GRILL
A3(420X297) Sungdong Shipbuilding & Marine Engineering Co., Ltd. D310-303-00
PAGE 03 / 08

5. AIR BALANCING TABLE 6. SPECIFICATION OF MECH. VENT. FAN HULL NO.


DWG. NO.
S3087/88/89/90
S3087/88/89/90/91/
92200A423001AB

AIR BLANCING TABLE SPECIFICATION OF MECH. VENT. FAN


MECH. SUP. MECH. EXH. NAT. SUP. NAT. EXH. RETURN AIR VOL. TOTAL PRESS.
DECK A/C SUP. SAN.EXH. No. DESCRIPTION FAN TYPE Q'TY LOCATION
ROOM
㎥/h ROOM
㎥/h ROOM
㎥/h ROOM
㎥/h AIR (㎥/h) (Pa)
NO. NO. NO. NO.
1 AIR HANDLING UNIT CENTRIFUGAL 18,473 2,217 1 UPP - DK.
503 157 503 157 501 3,210 396
NAV. 3,811 131 0 2 HOSPITAL EXHAUST DUCT 275 1 UPP - DK.
502 470
3 CO2 ROOM DUCT 576 310 1 UPP - DK.
4 PAINT&LAMP ROOM EXHAUST AXIAL 298 93 1 UPP - DK.
C 3,224 1,346 1,878
5 FAN COIL UNIT FOR GALLEY CENTRIFUGAL 689 550 1 A - DK.
6 CREW'S REC. ROOM EXHAUST DUCT 540 325 1 A - DK.
B 2,508 823 1,685 7 OFFR'S REC. ROOM EXHAUST DUCT 540 325 1 A - DK.
8 GALLEY SUPPLY AXIAL 1,588 158 1 B - DK.
212 1,588 204 540 212 1,253 202 263
207 540 9 GALLEY EXHAUST AXIAL 3,530 235 1 B - DK.
<F.C.U FOR GALLEY> 205 411
A 4,501 351 210 120 210 200 209 223 2,049 10 SANITARY EXHAUST CENTRIFUGAL 5,103 899 1 C - DK.
212 476 212 3,175
213 93 213 155 11 BATTERY ROOM EXHAUST AXIAL 157 88 1 NAV. - DK.
12 W/H WINDOW DEFROSTING FAN DUCT 427 380 2 NAV. - DK.
101 576 101 576 111 355
UPP. 4,429 2,452 104 396 104 66 115 959
113 298 333
113 298

TOTAL 18,473 5,103 2,277 6,037 2,350 6,015 5,945

* RETURN AIR : 32.18 %


( 5,945 / 18,473 )

200A423001AB-VDIA
File Name :
A3(420X297) Sungdong Shipbuilding & Marine Engineering Co., Ltd. D310-303-00
PAGE 04 / 08
7. VENT.DIAGRAM FOR UPPER DECK HULL NO.
DWG. NO.
S3087/88/89/90
S3087/88/89/90/91/
92
200A423001AB
106 107 108 109 110 111
2 2 2 2 2 2
10.5m 10.7m 5.4m 8.1m 36.0m 24.1m

CREW(1) CREW(2) E/R ENT. ENG.CHANG.RM FOAM & FIRE CONTROL ROOM GYMNASIUM / SUEZ CREW ROOM

135 50 171 50 267 267 594 594 405 50


6.1 10.0 7.6 10.0 10.0 10.0 5.0 5.0 8.0 10.0

38
108 RDG-1 (NORMAL CLOSED)
110 PR20
106 107 109
V.S.D V.S.D 111
PR8 PR10
MS25-C01 MS25-C01 KU-160
PK-6 PK-6 PK-6 MS25-C01 MS25-C01 MS25-C01

(HAZARDOUS AREA)
(HAZARDOUS AREA)
PK-6

UR10

PR12
PR8

PR8

35
PR8
PR8 PR10

PR8

PR8

PR8
5000

5000
KU-160 PR10 PR8
KU-160 UR10 UR12

50
A.P
50 50 UR10

PR10
DN
PK-6 KU-160 KU-160

UR12 N.R.F
T/S T/S
MLG-55

N.R.F S.D
PR10
V.D
LOCKING DEVICE
W/PAD LOCK
T/S *

SPECIAL
SP10

UR10
121
PR10 PR12 PR12 PR12

85
UR10 UR10

A.P
123
118 700C
3.7m
2

6.3m
2
NAT.VENT FOR LOBBY
LINEN LOCKER 122 UR12 UR12 UR16 UR20 UR10 FOAM & FIRE CONTROL ROOM

GL-20
V.D N.R.F PR16
2.9m
2
PR10
LOBBY N.R.F LV-43 (594)
PR12 PR12 PR12

S.H=610

S.H=610
V.D N.R.F
104 104 121 PASSAGE

700C

700C
123 120

UR12
PR16 PR16 37.1m
2
PR16 V.D 2
9.0m
5.0 5.0 UR20 NAT.EXH.FOR

GL-20
UR20 SP20 PIPE DUCT/CABLE TRUNK

V.D
N.R.F

178
GYMNASIUM / SUEZ CREW ROOM

30

28
700C 700C
LV-33 (355)

V.D
SPECIAL

N.R.F
N.R.F
105 [STAIRWAY DOOR] LOCKING DEVICE 50T THERMAL INSULATION

UR20
W/PAD LOCK

M.D.H
PR8
GAS DETECTOR

SUPPLY AIR DUCT


2
9.0m
UR10 * E/R ESCAPE TRUNK (RETURN AIR :305)

UR20
*NOTE*

UR16
112

1000X500X4.5T
UR20
G/S:500X200
DECK CHANG.RM "DURING AIR CON. OPERATION, (FOR HYDROCARBON GAS)
117 UR10 120 112
RDG-1

UR12
DOOR TO BE OPEN."

N.R.F
KU-160 KU-160

N.R.F
PR10 FRESH AIR INTAKE
2
30.8m
297 297
2
3.6m
PK-6 PR8 AIR CONDITIONING ROOM
COMMON KU-160 119 FOR AIR CON.PLANT
KU-160

N.R.F V.D
10.0 10.0 TOILET 105

N.R.F
PR8 PR10 V.D N.R.F PK-6 PK-6 LV-1215 (12,473)

V.S.D
2
7.9m
118 STAIRWAY S/E 305
178 PK-6 PK-6 V.D 117 H=700 "A"
F/A 3.0

PR10

PR16
15.0 R/A

N.R.F
* H=800
NAT.SUP.FOR MLG-55

700C
1
HOSPITAL PR10

PR16
PR10

LV-33 (66) KU-160 A.H.U


PR16PK-6 PK-6 V.S.D

MEAT RAIL
116D
PR16 F.D

V.D
PK-6
3
11.1m
PR8 103 -18℃

25
UNIT
FISH ROOM

UR16
104 104 MS25-C01
COOLER

PR10
2
16.2m
550X400X3.2T 550X400X3.2T RETURN AIR DUCT
PK-6 KU-160
PR8

750C
HOSPITAL 2
MECH.EXH.
FOR HOSPITAL UR16 116A
396

*
330

750C
3
16.0m
LV-33 (396) MS25-C01 PK-6 PK-6 2-T.S.S 2-T.S.S

750C
UNCOOLED
CK-160C KU-160 1200X600 1200X600
N.R.F

LOBBY

RDG-1
8.3 6.6 NAT. SUP. FOR

RDG-1
PR12

PR8 PAINT & LAMP STORE

5-GARBAGE BIN(100L)
PR8

1200X600
1200X600

2-T.S.S
2-T.S.S
PK-6 UR12 750C LV-33 (298)
MLG-55 PR8 116C
66
UR10

115
PR10

2-T.S.S(W.B)
KU-160 UNIT

PR16

PR16
700X600
3
20.3m MEAT RAIL
COOLER
+4℃
238

PK-6 PK-6 VEGETABLE 116B


PK-6 AWA-300/150

(NORMAL CLOSED)
ROOM

1200X600
3
15.6m
T/B MECH. EXH. FOR

2-T.S.S
UR10

-18℃
UNIT

W/N
MEAT ROOM

V.D PR20
2-T.S.S(W.B)
COOLER
PAINT & LAMP STORE

1200X600
103 UR10

UP(700B, 55˚)
102
LV-33 (298)

20
2 2
12.6m 4.8m
2-T.S.S(W.B)
CREW'S LAUNDRY DRYING KU-160 KU-160 1200X600 114 4
A.P

ROOM 113
102
862 624 238 NAT. SUP. FOR S.H=610 S.H=610

CO2 ROOM 1000C 700C


15.0 15.0 CK-200B
15.0 LV-43 (576)
3 [VOLUME/CLOSED DAMPER]

DRY PROVISION STORE


[VOLUME/CLOSED DAMPER]

DRY PROVISION STORE


*NOTE*

NAT. SUPPLY. FOR


*NOTE*

NAT. VENT. FOR


"KEEP CLOSED WHEN HEATING IN OPERATION"

NAT. EXH. FOR


"KEEP CLOSED WHEN COOLING IN OPERATION"

GARBAGE STORE
MECH. EXH. FOR

LV-54 (959)

LV-33 (124)
LV-54 (959)
V )

CO2 ROOM 116 115 113


8P
0

3 2 2

LV-43 (576) 63.0m 37.3m 11.3m


30

COLD CHAMBER DRY PROVISION STORE PAINT & LAMP STORE


24
0F

) )
G. MB
(60

DW 02 959 298
EM

R 40
HE M68
ST

15
T 6.0
101 O 00 8.0
G )
SY
.

EE (2
ISH WG

(S E/R
2
34.9m
NG IN 114
GU R D
IN

CO2 ROOM ASI 'T 2

C RR
E

7.5m
EX OTH

NE Y A GARBAGE STORE
576 GI E R A DECK
E N H IN
TIN
IRE SE E

C
5.0 MA A/S
(

900
FROM AIR CON.PLANT
(HULL DUCT)
2F

(RECT.DUCT)
CO

E/R HATCH
ED
FI X

50T THERMAL
INSULATION
E/R ESCAPE

2400
TRUNK
)
AB
10

010
41
A2
(3 00
G.) OM

VERTICAL LADDER
DW RO
E R NE
DER

TH YLE
E O ET 125
DN

(SE X/AC UPPER DECK


LAD
TI CAL00B )

O 2 (300B)
OF 4.6m
R'T
AIR LOCK
(3

AR
VER

VIEW "A"
700C 700C S.H=610
NT NT 700C

127 126
2 2
2.2m 2.2m

AC.RM OX.RM
K.P K.P

DECK CAMBER

A3(420X297)
PAGE 05 / 08
7. VENT.DIAGRAM FOR A DECK HULL NO.
DWG. NO.
S3087/88/89/90
S3087/88/89/90/91/
92
200A423001AB

204 205 206 207


2 2
29.0m 34.4m 2 2
13.1m 29.0m
CREW'S RECREATION ROOM CARGO CONTROL ROOM SHIP'S OFFICE OFFICER'S RECREATION ROOM

540 540 1311 300 540 540


8.9 8.9 18.1 10.9 8.9 8.9

38
205 207
204 206
MS35-C01 MS35-C01 MS35-C01
MS25-C01 MS25-C01 MS25-C01 MS25-C01

(HAZARDOUS AREA)
PR8

(HAZARDOUS AREA)
)
AB
05

35 PR10
0 MS25-C01

PR10

PR10
38

PR8
PR8
PR8 PR10 )
G. 00
A5
DW (3 PR10
R OOM

5000

5000
PR20 300

700C
E
PR10 H R
OT OL PR16
E E TR
(S ON
C PR8

PR12
PR10
PR8 GO

PR10
MLG-55 AR MLG-55
OF
C MS25-C01 PR8

PR12
MS25-C01 MLG-55 R'
T PR10
AR
MS35-C01 MS25-C01
MS35-C01 MS35-C01 7
6 CK-200B

UR20

PR16
600
PR20 N.R.F

600
MECH.EXH FOR MECH.EXH FOR

UR20
CK-200B
CREW'S REC. ROOM PR12
D.W.F
N.R.F OFFICER'S REC. ROOM
UR20

V.D N.R.F
LV-43 (540) LV-43 (540) 217

V.D
219 PR16 PR16218 PASSAGE 220 9.0m
2

NAT.EXH FOR

2,049
LOBBYUR20 UR10 UR10 N.R.F
2
1.8m PIPE DUCT/CABLE TRUNK

V.D

V.D
102

59
131
CARGO CONTROL ROOM LOBBY

UR10
59

30
LV-33 (411)

N.R.F
203 208

UR10
[STAIRWAY DOOR] A/S
203 N.R.F KU-100

M.D.H
2
3.9m
*NOTE*
NAT.EXH FOR UR10

UP
2
3.9m
LOCKER(A) V.D N.R.F 208 LOCKER(B)

PR16
"DURING AIR CON. OPERATION, 217

600
CREW'S MESS ROOM

UR12
600
PR16
59 UR16 215 DOOR TO BE OPEN." UR10 UR10
KU-100 59
LV-33 (263)

N.R.F
5.0 KU-160 KU-160 216 N.R.F
"C" 5.0

DN
2
7.9m

.C
S/E A-60 INSULATION PR8

W
214 STAIRWAY 450 450
DN(800B, 50˚)
MLG-55 209 DN(800B, 50˚)
MS25-C01 MS25-C01

450
202 PR25 PR25

PR12
PR12
2
46.9m

CREW'S MESS ROOM PR10 PR12 PR16 PR20


PR8 PR8
155 212

PR10

PR16
PR8

PR8
863 MS25-C01 F.C.U 5 MS25-C01
MLG-90 200

M.D.H
8.8 213 210 NAT.EXH FOR

25
PR8
OFFICER'S MESS ROOM
*
PR10 UR16

PR20
MS25-P00 MS25-P00
MS25-C01 MS25-C01 MLG-55 LV-33 (347) 209

M.D.H
MS35-P00 MS35-P00

PR10
PR10

450
4 F.D A-60 INSULATION 46.8m
2

215 UP(800B, 50˚)


1 OFFICER'S MESS ROOM
GALLEY EXHAUST

PR12
PR8 PR8

50T THERMAL
GALLEY SUPPLY

450
INSULATION
2
3.4m

C.G.L. 600X250X4.5T F.D 947

PR25

300X250X4.5T

450
EXT.SYSTEM
CO2 FIRE
102 600X250X6.0T 9.6

PR8
PR8

MLG-55

PR8
PR8

450
10.0 MLG-90 65A
MLG-55
MS25-C01 MS25-C01 PR10 MS25-C01 MS25-C01
REMOTE CONTROL
MS25-P00 MS25-P00 FOR FIRE DAMPER

PR10
CO2 BOX

PR20

PR25
PR10
CO2 CONTROL BOX

M.D.H
202

DN(700B, 55˚)
20
211
214 THERMAL INSULATION
2
2.9m
COMMON
TOILET
131 213 212 210
2
7.4m
2
37.8m 2
9.5m
15.0 CREW'S PANTRY GALLEY OFFICER'S PANTRY
50T THERMAL INSULATION

NAT.VENT FOR 93 155 1588 476 3175 120 200


EM'CY GENERATOR ROOM 6.0 10.0 20.0 6.0 40.0 6.0 10.0
"B"
LV-33
) )
G. MB 450
DW 02
EM'CY GENERATOR

R 40
COFFERDAM

HE M68
15
T
O 00
EE (2
(S E/R
NG N A-60 INSULATION
ASI 'T I
C RR
NE Y A
GI E R
E N IN
H
212 217
C
GOOSENECK VENT FOR MA GALLEY S/E PIPE DUCT/
GOOSENECK VENT FOR GENERATOR ROOM NAT.SUP. CABLE TRUNK
GENERATOR ROOM MECH.EXH. (WITHOUT CLOSING DEVICE)
(WITHOUT CLOSING DEVICE) INSECT SCREEN SQUARE TYPE: 1000X1500
SQUARE TYPE: 1000X1000 WITH WIRE NET

A DECK 450

450
"B" S/E
B-DECK
10

201 121 121


EM'CY GENERATOR ROOM PIPE DUCT/
DRY PROVISION STORE
CABLE TRUNK

201 UPPER DECK


A-DECK
EM'CY GENERATOR ROOM

FR.10 FR.15 FR.25 FR.30


FR.19
VIEW "B" VIEW "C"

A3(420X297)
PAGE 06 / 08
7. VENT.DIAGRAM FOR B DECK HULL NO.
DWG. NO.
S3087/88/89/90
S3087/88/89/90/91/
92
200A423001AB

306
304 305 ELECTRICIAN 307 308
2ND ENGINEER DAY ROOM 4TH ENGINEER 163 50 PETTY OFFICER(1) CHIEF OFFICER DAY ROOM

294 165 50 6.0 10.0 165 50 294


6.0 6.0 10.0 6.0 10.0 6.0

38
304 306 307
305
MS25-C01 MS25-C01 MS25-C01 MS25-C01 MS25-C01 308 MS25-C01

MS25-C01
PR8

PR8
35

PR8
PR8

PR8

PR8

PR8
PR12 PR16 PR12 PR10
50
50 50 PR8 PR10
T/S T/S T/S
303 UR10 UR10 309
303 309

77

77

PR8
UR10
PR16
2ND ENGINEER CHIEF OFFICER

PR16
BED ROOM BED ROOM

50

371

115

113

115

371

50
MS25-C01
PR8 127 50
127 50 UR10
UR10 MS25-C01 6.0 10.0

V.D N.R.F
PR16

UR10
6.0 10.0

PR10
T/S T/S
318 N.R.F
PASSAGE

1685

V.D
30
V.D

N.R.F
315 [STAIRWAY DOOR] A/S

UR12
M.D.H
PK-6 *NOTE*

N.R.F
"DURING AIR CON. OPERATION, 310
317 104

N.R.F
104 DOOR TO BE OPEN." 316 PR8 310
302 302 KU-100

MS25-C01

V.D
50
PR8 STAIRWAY PIPE DUCT/CABLE TRUNK

50
PR16
A.P CREW(5)
CREW(4)

DN
S/E MS25-C01 154 50
154 50

UR10
DN(800B, 50˚)
T/S T/S DN(800B, 50˚) 6.0 10.0
6.0 10.0
PR8 90 94

N.R.F
312

PR8
314
LADDER SECURITY DOOR

LADDER SECURITY DOOR


UR10
MS25-C01 313 MS25-C01 MS25-C01
PR8

UR12
T/S T/S 311
301

25

UR10
PR8

PR8
PR8

PR12
CREW(6)
MS25-C01

CREW(3) 301 PR8 PR10 311


50 178 50 154 50

50
50
50

154 T/S T/S UR10 T/S MS25-C01


104 104 9 6.0 10.0
6.0 10.0 UR10
UR10 MECH.EXH.
FOR GALLEY
M (AMA-500/280)
MF-50 (3530)

UP(800B, 50˚)
315
BONDED STORE
8
95 95
FRESH AIR INTAKE

20
5.0 5.0 FOR FAN COIL UNIT
MV-30 (689)
M

NAT.SUP. 313 312


314 FOR GALLEY
MV-35 (1253) CREW(8) CREW(7)
CREW(9)
178 128 50 144 50
140 50 MECH.SUP. 8.6 6.5 10.0 7.1 10.0
7.2 FOR GALLEY
10.0
(AMA-350/150)
MF-35 (1588) ) )
G. MB
DW 002
ER 684
15
H
OT 00M
EE (2
(S E/R
G
S IN T IN
CA RR'
NE A
GI R Y
E N IN E
C H
MA
10

A3(420X297)
PAGE 07 / 08
7. VENT.DIAGRAM FOR C DECK HULL NO.
DWG. NO.
S3087/88/89/90
S3087/88/89/90/91/
92
200A423001AB
405 406 407
3RD ENGINEER 3RD OFFICER 2ND OFFICER

404 165 50 163 50 165 50 408


CHIEF ENGINEER DAY ROOM 6.0 10.0 6.0 10.0 6.0 10.0 CAPTAIN DAY ROOM

305 305
6.2 6.2

38
405 406 407
408
404
MS25-C01 MS25-C01 MS25-C01 MS25-C01 MS25-C01 MS25-C01

MS25-C01
PR8

35

PR8

PR8
PR8
PR8
PR12 PR16 PR8 PR10
PR8 418
50 50 50
T/S T/S PIPE DUCT/CABLE TRUNK
UR10 T/S UR10 UR10

PR12
77
PR12
UR10 UR10

77
PR16
403 409
403

N.R.F
382

115

113

115

382

50
A.P
50
409

MS25-C01
CHIEF ENGINEER CAPTAIN BED ROOM
PR8 PR8
BED ROOM
PR16 PR16 127 50
127 50 MS25-C01 6.0

UR12
T/S 419 PASSAGE T/S 10.0
PR12 PR16

PR10

N.R.F
6.0 10.0
THERMAL INSU. N.R.F V.D

30
N.R.F

V.D

V.D
1878
416 [STAIRWAY DOOR] (UP)PGL-20 PR20 A/S

M.D.H
h=1200

PR8
*NOTE* 410
402 PR20 N.R.F THERMAL INSU. V.D N.R.F

PR12
402 "DURING AIR CON. OPERATION, PR16

V.D
104 DOOR TO BE OPEN." 417 104 PILOT
418 410

N.R.F
MS25-C01
PETTY

UR10
50
KU-100 PK-6 10

50
PR8 50

450
OFFICER(3) PR8 STAIRWAY 154
S/E

DN
6.0

PR16
N.R.F
h=1200
PR8 MS25-C01 10.0
154 50

450

UR10
6.0 10.0 T/S (UP)UR10 T/S

N.R.F
N.R.F
UR10 UR10 UR12 UR16 UR10 123

PR8
279 V.D PR16

N.R.F
126

50T SOUND INSULATION


MS25-C01 N.R.F

25KU-160

SANITARY EXH.DUCT
PR8

PK-6
415

KU-160
411

UR10
PR12
UR10

500X400X4.5T
UR10
401 T/S T/S

KU-160 KU-160
MS25-C01 411 PETTY

PR12
401

PR8

UR10
PETTY 414 OFFICER(4)
OFFICER(2) PR12 412

PK-6
50
50

50 MS35-C01 MS35-C01

KU-160
207 50
T/S
T/S 207

50
157 157

PR10
8.1 10.0 8.1 10.0
PR8

PK-6
(UP)
PR12 PK-6 413

DN(800B, 50˚)

UP(800B, 50˚)
413 414

416 415 OFFICER'S LAUNDRY DRYING


ROOM
LOCKER CREW(11) 698 419
279

20
98 98 15.0 15.0
176 50 15.0
5.0 5.0 9.4 10.0

412

CREW(10)

173 50
9.3 10.0

B)
02 )
40 G.
M
6 8 DW
0M R
20 E
R( TH
15
E/ E O
IN SE
(
R' G
AR IN
T
Y AS
ER E C
H GI N
A C EN
IN
M

10

A3(420X297)
PAGE 08 / 08
7. VENT.DIAGRAM FOR NAV. BRI. DECK HULL NO.
DWG. NO.
S3087/88/89/90
S3087/88/89/90/91/
92
200A423001AB

501
WHEEL HOUSE & CHART SPACE

3341
15.0

38
T
PR10 PR8 PR8 PR10

R ILO

R ILOT
501

TE P

EL A P
E L MA
SH A N A

SH NAM
TE
PR12 MS35-P00 MS35-P00 PR12

PA
PR20
PR8 PR8

PR20
MS35-P00

(DUCT HEATER)

(DUCT HEATER)
35
MS35-P00

CK-200B DTH03-500

DTH03-500
PR10
PR10 PR12

PR10
PR10

PR16

CK-200B
12
PR10 MS35-P00 MS35-P00 PR10 12

PR12
MS35-P00 MS35-P00

PR20
MLG-55 MLG-55

PR10

PR10
MLG-90 PR20 PR20 MLG-90
PR10 THERMAL INSULATION PR10

THERMAL INSULATION
PR12

PR20
MS35-P00 MS35-P00
NAT.EXH. FOR NAT.EXH. FOR

PR10

30
WHEEL HOUSE & CHART SPACE V.S.D WHEEL HOUSE & CHART SPACE
MV-40 (1,605) 505 PR20 MV-40 (1,605)
MS35-P00 STAIRWAY V.S.D
PR10

MLG-90 MS35-P00 MLG-90

DN
131
502

N.R.F
KU-160 503 11 PK-6 PK-6
[NOTICE PLATE] PR10 PR8
UR10 M
"THIS VENTILATOR OPENING IS NOT S.D RDG-1

PR12(DN)V.S.D
504
TO BE CLOSED OR BLOCKED

25
AT AY TIME-EXPLOSIVE GAS." (H V.S.D(N.C)
AZ 3
AR
DO 000

PR20
MECH.EXH. FOR US
AR
BATTERY ROOM E A) UP(700B, 50˚)

HCA-300/150(157)
MECH.EXH. FOR
NAT.SUP. FOR SANITARY SYSTEM

ELEC.EQUIP.ROOM

NAT.VENT FOR
ELEC.EQUIP.ROOM
LV-33 (470)
BATTERY ROOM MV-55 (5,103)
DOOR VENT.(157)

NAT.EXH FOR

LV-33 (470)
DN(800B, 50˚)
503
504 502
BATTERY
COMMON ELEC.EQUIP.ROOM
ROOM
TOILET

20
131 157 470
15.0 10.0 15.0

B)
M
40 .)
02
68 G
0M DW
20 R
R( E
E/ OTH
15
T EE
R' (S
IN
AR L
Y NE
ER U N
IN F
H
AC
M

10

A3(420X297)