Isolated-Tappered With Actual Surcharge
Isolated-Tappered With Actual Surcharge
5 m
Concrete Grade 20 N/mm2
Unit weight of RCC 2.5 t/m2
Unit weight of Earth 1.8 t/m2
Footing Thicknees,D 0.4 m Effective Thickness of footing= 0.340 m
400
F1 d= 0.15
150
m 340 mm
Guiding Pressure, Q 10.93 t/m2 ok (As Guiding base pressure is less than SBC)
109.2579 KN/m2
Check:
Reinforcement
Reinforcement Along X-Direction/ Parellel to Lx d/2 d/2
Moment at face of Column, Mz=q*Lz(Lx/2-Cx/2)^2/2 101.7737 kN-m For a beam width=Lz= 2.3 m
44.24946 kN-m/m (For Unit width of beam)
Ultimate Moment=1.5*Mx 66.37418 kN-m/m
b= 1000 mm
Let, x is neutral axis depth, d/2
x/d=1.2-sqrt((1.2^2-(6.68Mu/fck*b*d^2)) 0.082759
Lever Arm, Z=d*(1-0.416*x/d) 328.2945 PUNCHING CHECK.
Ast= Mu/(0.87*fy*z) 712.6608 mm2 Provide Ast Calculated
Let 12 dia bar is used,
158.6168 c/c DIA OF BAR USED:
Ast(min), 0.12% 0.18 12
let 10mm dia bar is used, 436111.1 c/c CX
So, Provide, 12 Φ@ 100 C/C