Cable Diagram Cutter Drive 271195900 - LP - D - 090917

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

1 2 3 4 5 6 7 8

VISIO

A
Main Switch Board =MSB 230 V Panel
A
Aux. Supply Heaters 230V

Control Commands
Aux. Supply 400V
Mains supply transformer
100 12 x(3 x150 mm²)

119 10x2x0,75 mm² shielded


121 3 x1,5 mm² Heaters Converter Winches PS
+JB
110 3 x1,5 mm² Fan 1 2 Transformer =AE11
111 3 x1,5 mm² Fan 2
Panel 3
(Side and Ladder Winch )
B B
116 10 x 1,5 mm²
108 3 x 4 mm²

107 3 x 16 mm²

101 3 x(3 x 95 mm²)

102 3 x(3 x 95 mm²)

103 3 x(3 x 95 mm²)


shielded conv.cable

shielded conv.cable

shielded conv.cable
Supply converter
Supply converter

Supply converter
Converter
Cutter drive
=AE1

+E12 +E11 +E10 +E9 +E8 +E7 PLC


AC Power Supply Reactor
Reactor cubicle AC Power Supply Reactor cubicle

PCF Fibre Optic Cable


C cubicle C

Fibre Optic C.
+E1 +E2 +E3 +E4 +E5 +E6
PWM-Inverter Controller NC Controller MC PWM-Inverter PWM-Inverter Cool. Water Supply

Remote
112 4 x 1,5 mm² I/O
Emergency Stop
130 Ethernet CAT5
Service & Maintenance DREDGE OPERATORS

106 3 x(3 x 95 mm²)


shielded conv.cable
105 3 x(3 x 95 mm²)
shielded conv.cable

CONSOLE

LOCAL
D EMERGENCY D
113 4 x 1,5 mm² STOP
Cable chain
104 3 x(3 x 95 mm²)
shielded conv.cable
118 10 x 2 x 0,75 mm²

117 4 x 2 x 0,75 mm²


120 3 x 1,5 mm²

109 3 x 4 mm²

shielded

ATTENTION !
shielded

The following instructions have to be


Observe protection note according to DIN34

observed:
Motor
Gearbox The cross sections are suitable for:
E Heater - ambient temperature 50°C E
+A1
+A2 +A3 - conductor temperature 85°C
- insulation: crosslinked PE
or EP rubber
M
1 2 1 2 1 2 1 2 1 2 1 2 3~ - free air circulation, no cable bunches
M Slip Monitoring
3 3 3 3 3 3
LK M p p p p N

Heater
3 x PT100 3 x PT100
Air
3~ Tx
3~ M For EMC reasons it is strongly
Windings Spare Leakage LO- LO- LO- LO- LO- 3~
Encoder
sensor Fan Motor
LO-
Filter
Press. Press. Press. Temp Level recommended to use shielded cables
>1,3bar <1bar <0,7bar >75°C
+M1 only!
F
D Cable 113 to +E3/115 del. 17.09.09 GK
C Clearer location design. 22.04.08 Ti date 28.06.2006 =
Mazagon India Cable diagram 2005.0.1108 - 51.40 - 00004634
B VOSTA No. added 04.04.07 Ti desig. M. Tigges +
Cutter dredger for DCI
A Service cable No. 130 14.08.06 Ti check Cutter head drive PRELIMINARY 271. 195 900.LP
sheet 1
rev. revision date name norm res. from: subst. for: repl. by: total 1
lt. DIN 6771/Teil 5 1 2 3 4 5 6 7 8

You might also like