RFQ 1106-15907-002
1.0 General OK
9.0 Exceptions/Qualifications OK
10.0 Pricing OK
11.0 Transportation OK
19.0 Obligation OK
1
20.0 Contractual Terms OK
22.0 Jurisdiction OK
2
Comments and Exceptions
RFQ 1106-15907-002
2.0 Design, Drawings, Layout and Specifications See our Comments & Exceptions
6.0 Quality Surveillance and Inspection Requirements See our Comments & Exceptions
3
Comments and Exceptions
RFQ 1106-15907-002
Technical Documents and Attachments
110615907-PK-0521-002-TDA
4
Comments and Exceptions
RFQ 1106-15907-002
Area 5 FC 1-E Optimization 2011
Scope of Work
PK-0521 – Glycol Heater Package
DISCLAIMER OF LIABILITY OK
2.0 Scope OK
5
Cenovus Specifications & Standards Comments &
Exceptions reserved
8.0 Mechanical
8.1 Piping
Vendor shall be responsible for material supply, OK
Fabrication, installation, painting and insulation of all
Piping as presented in this scope of work
6
Glycol inlet/outlet piping integral to the heater shall be See our Comments
designed and constructed according to ASME B31.1 & Exceptions
Vendor shall provide for high point vent valves and low OK (on heater
Point drain valves on package piping, as required Headers only)
8.2 Valving
All valves shall be as per the latest Cenovus P&Ids and latest OK
approval copy of Vendor drawings
All manual valves shall be supplied as per Cenovus’ Approved See our Comments
Manufacturers List Rev. 12 and as per Cenovus Specification & Exceptions
TR-44-SPC-00-002-01 Rev.3 “Valves”
All small bore valves and block/blend valves shall be as per See our Comments
Section 11.0 – Instrumentation & Exception
7
8.5 Glycol Heater Design OK
8.5.1 Coil OK
8.5.2 Connections OK
8.5.3 Sight Port OK
8.5.4 Stack OK
8.5.5 Combustion Air Blower OK
8.6 Hydrotesting
Glycol Inlet/Outlet OK
Air Preheater Glycol OK
Building Heater Glycol OK
Fuel Gas Fuel gas piping only
will be tested with
water. Complete
assembly cannot be
hydro’d, we will do
premature leak test
of fuel train after
assembly.
Vents N/A
Instrument Air N/A
8.7 Materials OK
Non destructive testing of the process piping is governed See our Comments
By ASME B31.3 and the power piping by ASME B31.1. & Exception
All external coating, painting and surface preparation shall be See our Comments
Done in accordance with Cenovus Specification & Exceptions
8
TR-43-SPC-00-019-01 Rev. 6 “Painting and Galvanizing
The heater and piping shall be insulated as per Cenovus See our Comments
Specification TR-43-SPC-00=021-02 Rev. 6 “Insulation” & Exceptions
The Glycol Heater data sheet 110615907-H-0501D-002-DS Heater shell is
Rev. B and generally accepted industry standards. Insulation internally lined with
shall be readily removable for external inspection of the heater cerwool blanket
shall be effectively flashed to protect from outdoor exposure. Refractory, and will
not be insulated. We
offer personnel
protection insulation
and cladding on the
heater headers.
Glycol Inlet/Outlet OK
Fuel Gas Not required
Air Preheater Glycol Our offer ends at
preheat inlet/outlet
flange
Vent (PSV Relief) Not offered
9.0 Civil/Structural
9.1 Skid and Equipment Pipe Support See our Comments
& Exceptions
9.2 Access Ladders and Platforms
The Vendor shall provide walkways, platforms, stairways See our Comments
and ladders complete with cages where required and in & Exceptions
Compliance with Cenovus Specification Rest OK
TR-43-SPC-00-025-01 Rev. 4 “Skid Mounted Equipment”
9
9.3 Building
As per Section 2.0 above, the heater package shall be OK, See our
complete with a building extending from the skid structural Comments &
base. Exceptions
10.0 Electrical
10.1 General OK, See our
Comments &
Exceptions
10.2 Area Classification OK
10.3 Electrical Installation Testing OK, See our
Comments &
Exceptions
10.4 Junction Boxes OK
11.0 Instrumentation
11.1 General Requirements
The package shall be adequately instrumented based OK, See our
on Vendor’s standard design to facilitate safe, smooth Comments &
and reliable operation Exceptions
10
All instruments shall have stainless steel tags stamped OK
with Cenouvs issued tag numbers.
All building fire and gas detectors, horn and alarm beacons OK
will be supplied and free issued to the Vendor by Stantec
along with specific location and installation instructions.
11
Blower suction and discharge pressure differential Low combustion
transmitter with low/low dP shutdown Air switch is required
by code, Flame
safeguard cannot
accept transmitters
Pressure gauge on the blower discharge OK
15.0 Guarantee OK
12
Comments and Exceptions
Final Databook Turnover
Requirements by Vendors
B. Fabrication Visits OK
Mechanical ITP OK
Electrical ITP OK
Instrumentation ITP OK
13
Comments and Exceptions
RFQ 1106-15907-002
14
Comments and Exceptions
RFQ 1106-15907-002
15
Comments and Exceptions
RFQ 1106-15907-002
Open Invoice > Supplier
Cenovus FCCL Ltd. Submission Guidelines
OK