Carparking

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

GENERAL NOTES

99'-2" 1. ONLY WRITTEN DIMENSIONS SHALL


BE FOLLOWED.
2. SAFE BEARING CAPACITY OF THE
SOIL IS TAKEN FROM SOIL REPORT.
3. CLEAR COVER TO MAIN STEEL:
a) FOR ALL FOOTINGS= 60 mm
b) COLUMNS = 40 mm
c) BEAMS = 30 mm
d) SLAB = 20 mm
12 e) WALL = 25 mm
17 15 4. LAP LENGTH SHALL BE A MINIMUM OF
19 18 "50 TIMES DIA OF BAR".
5. MORE THAN " 50% " OF BARS SHALL
12 NOT BE CURTAILED AT ONE PLACE.
6. DISCREPANCY IF ANY, SHOULD BE
BROUGHT TO THE NOTICE OF THE
ENGINEER-IN-CHARGE.
7. GRADE OF CONCRETE :
FOOTINGS M20,COLUMNS M25.
8. GRADE OF STEEL :
Fe-415/500

20

IMPORTANT NOTES

11 1. THIS DRAWING IS UNDER


12 COPY-RIGHT OF STRUCTURAL
ENGINEER

2. ALL DRAWINGS ARE SUBJECT TO


SANCTION FROM CONCERNED
AUTHORITIES.
16 6 3
3. ANY DISCREPANCIES IN THE DRG.
SHOULD BE IMDTLY BROUGHT
9 TO THE NOTICE OF THE STRUCTURAL
10 ENGINEER.

4. ALL WORK IS TO BE CARRIED OUT


STRICTLY AS PER DRAWINGS

5. STRUCTURAL ENGINEER WILL NOT


11'-4" BE RESPONSIBLE FOR INCORRRECT,
BAD OR DEFECTIVE WORK.
8
6. BUILDING IS DESIGNED FOR STILT
+G+4 FLOORS(6 SLABS) Only
7

.\GVMC-sgn-BEST_BLUE_2022-23.png

ALL DIMENSIONS ARE IN FEET, UNLESS


SPECIFIED

IMPORTANT NOTE:
9'-4"
THE DESIGNS ARE VALID ONLY WHEN
5 PROPER CONSTRUCTION PRACTICES
4
AND QUALITY CONTROL ARE
IMPLEMENTED IN THE SITE .

IF THE SOIL STRATA IN THE SITE ARE


OBSERVED TO BE DIFFERENT FROM
THOSE MENTIONED IN THE SOIL TEST
REPORT, THE SAME SHOULD
BROUGHT TO THE NOTICE OF THE
2 STRUCTURAL ENGINEER IMMEDIATELY
FOR SUGGESTING MODIFICATIONS.
1

SHEET NO:
02
CLIENT:
Raju garu

1"
9'-22
NAME OF DRAWING:
4"
10'-73

CAR PARKING
4'
ISSUED:
23-12-2022

Dr. D.MANASA
30' WIDE ROAD M.E.(Strs.),Ph.D.(Strs.)
CONSULTANT STRUCTURAL ENGINEER

Car Parking D.No:6-12-24/47, FLAT NO: 201


EAST POINT COLONY,VISAKHAPATNAM.
MOBILE No.9505048155.

You might also like