Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 2

Design of Isolated Footing (Calculation Sheet) EGYPTION CODE F2

INPUT DATA:
fcu (footing)= 300.00 kg/cm²
fcu (column)= 300.00 kg/cm²
fy = 3600.00 kg/cm²
Net permissible 1.25 kg/cm²
soil presure
Footing cover 5.00 cm
c1 (column
30 cm
dimention)
c2 (column 50 cm
dimention)
Pw
Working load 77 tons

Pu
Ultimate load 115.5 tons

1-Detemination of base area


Af=1.08*Pw/Net permissible soil presure
Af = 6.65 m²

PC AxBxT= 2.70 2.50 0.30 m


RC axbxH= 2.10 1.90 0.60 m

2- Factored load and soil reaction

qs=Pu/(axb) = 28.95 t/m²

a-Check of Shear

qu = qs x tributary area / (b*d) 2.76 t/m²

w= 0.53 m

Tributary area = 1.10 m²

qcu = 7.16 kg/cm² > qu OK

b-Check of Punching

Qup = Pu - qs x tributary area 89.664 ton


qup = Qup / bod = 4.29 kg/cm²
Tributary area =( c1 + d ) x ( c2 + d ) 0.893 m²

Qcup1 14.13 kg/cm²

Qcup2 27.87 kg/cm²


16 kg/m²
Qcup3 15.55 kg/cm²
Qcup 14.13 kg/cm² ok
a 4.00
bo 3.80 m

1/2
3- Design of section due to moment

Moment due to long direction

Mu = qs x ( a / 2 - c1 / 2 )² / 2 9.26 m.t /m'

As 9.17 cm²

As_ total = 19.25 cm²

Area steel due to short direction

As _total = 17.42 cm²

Spacing
Use As (short direction) 10 F 16 23 cm
Use As (long direction) 9 F 16 23 cm

4- bearing Strength of column

0.67A1fcu/gc 201.000 ton > Pu ok

5- bearing Strength of footing

The bearing strength of the footing is increased by a factor


due to the

0.67A1fcu/gc 402.000 ton > Pu ok

2/2