Lift/Lower System Functional Operation Pedal depressed, moving the Lift/Lower Control

Overview thumb control knob (VR2) on the right-hand


Electric Steer Manager Control Handle clockwise causes the following
The Electric Steer Manager (ESM) reports the to occur:
voltage of the Main and Mini-Mast Pressure 1. The VR2 output voltage to the CM at
Transducers. It sends this information over JPC24-10 decreases to a voltage lower
BUS+/BUS– to the CM for the generation of than when in the neutral position.
weight-related fault codes, operational 2. The CM, detecting this voltage decrease,
restrictions, and information to be sent to the determines that a request for lift has been
Operator Display. made. It does this by comparing the input
Height Manager - Main Mast voltage with the learned voltage values for
An infrared Optical Sensor supplies inputs to lift, lower, and neutral. The CM processes
the Main Height Manager. The Main Mast this voltage and sends a message over
Height Manager sends information over BUS+/BUS– to the TM/VFC.
BUS+/BUS– to the CM for the generation of 3. The TM/VFC receives the message and
height-related fault codes, operational supplies a PWM voltage (P CONTROL) to
restrictions, and information to be sent to the the Coil Driver 3 (CD3) Card at JPS12-2,
Operator Display (OD). enabling the P Contactor coil driver.
Height Manager - Mini-Mast 4. With the P Contactor coil driver energized,
A Multi-Head Proximity Sensor supplies inputs the P Contactor coil has a path to ground
to the Mini Height Manager. The Mini-Mast from JPS29-3, through the coil driver to
Height Manager sends information over JPS12-9, through FU12 to B-PC at
BUS+/BUS– to the CM for the generation of JPS14-1 and JPS14-2. This energizes the
height-related fault codes, operational P Contactor coil, closing the P contactor
restrictions, and information to be sent to the tips, and starting the lift pump motor.
Operator Display. Models SA S/N > 03217 and
Carriage Manager
The Carriage Manager (CM) uses information SB S/N > 00761 have a Dump Solenoid
based on inputs from the Main Mast Height
Manager and Mini-Mast Height Manager to limit Valve (SOL99) installed. The “Dmp Vlv”
speed due to height and to determine the lift/
lower “decel” points for the Main and Mini-Mast setting in Configure Mode must be set ON
when nearing their extremes of movement. The
CM also uses information from the ESM or TM for trucks equipped with SOL99 and OFF
to stop lowering if the platform is hung up.
The Carriage Manager (CM) monitors the input for all others. The normally open SOL99
from the Lift/Lower Potentiometer (VR2) and
sends lift/lower requests to the TM over valve has its coil wired in parallel with the
BUS+/BUS–.
P Contactor coil. It is also energized (valve
The CM receives height count information from
the Height Managers and calculates the values
closed) by the P Contactor coil driver. With
from the Height Managers with respect to the
value of the reference point (fully lowered SOL99 coil energized (valve closed), the Lift
position). The CM then updates the OD height
indication. The CM uses the information from Pump output is available to the lift system
the ESM to update the OD for weight indication.
Slack Chain Switch during a lifting function. When the lift
When the slack chain switch is open or the
pressure transducer senses no pressure, lift is request is removed, the P Contactor coil is
limited to a maximum of 23.6 inches (600 mm)
so that the operator can correct a hung-up de-energized, along with the SOL99 coil,
platform and remove the slack in the chain. If
the slack chain condition will not correct, the returning the valve to its normally open
ability to lift will cease.
Main Lift state. This provides a path back to the
With the Key Switch ON and the right Deadman
Reservoir for the Lift Pump output, Cylinders.

resulting in the rapid relief of pump 8. The hydraulic fluid flows through the Lift

pressure to the system, thereby reducing Select Solenoid Valve (SOL3) and the Main

the transition delay between a lift to lower Load Holding Solenoid Valve (SOL1) to the

function. Lift Cylinders.

5. The TM/VFC also supplies a PWM voltage 9. The TM monitors the voltage at P

to the Lift/Lower Proportional Solenoid Contactor tip P-2 through the P-SENSE

Valve (SOL4) coil driver at JPS11-4, line at JPS14-7. The TM/VFC uses this

enabling the Lift/Lower Proportional information to determine if the P

Solenoid Valve coil driver. Contactor tips are open or closed. On

6. With the Lift/Lower Proportional Solenoid trucks not having the Dump Solenoid

Valve coil driver energized, SOL4 has a Valve (SOL99) installed (Models SA S/N <

path to ground from JPS19-4, to the coil 03218 and SB S/N < 00762), when the lift

driver at JPS11-9, through the coil driver request is removed (VR2 returned to the

to JPS11-11, through FU-12 to B-PC at neutral position), the P Contactor coil is

JPS14-1 and JPS14-2. immediately de-energized, but the

7. The Lift/Lower Proportional Solenoid Valve Lift/Lower Proportional Solenoid Valve

initially moves to the full open position, (SOL4) is kept fully energized (open) until

directing all hydraulic fluid flow back to the Lift Motor stops turning. It does this

the Hydraulic Reservoir. It then positions because a spinning motor does not stop

proportionally to the lift request voltage instantly. Due to the voltage (back EMF)

from VR2. The less the lift request voltage, produced in the Lift Motor as it spins to a

the more open the Lift/Lower Proportional stop, the P-SENSE line has some voltage

Solenoid Valve will be, permitting more on it. The TM/VFC monitors the P-SENSE

fluid to return to the Reservoir, resulting line (JPS14-7) to determine when the Lift

in a slower lift rate. A faster lift rate Motor has stopped turning (no more back

requires a greater lift request voltage, EMF produced). At that point the TM/VFC

which further closes the valve, and ports turns off (closes) the Lift/Lower

more hydraulic fluid to the Main Mast Lift Proportional Solenoid Valve coil driver. If
the Lift/Lower Proportional Solenoid Valve altura de Mini. El Manager de altura Mini-Mast envía
información sobre BUS + / BUS– cm para la generación
coil driver were de-energized at the same de códigos de avería relacionados con la altura, las
restricciones operacionales e información se envíe a la
time as the P Contactor coil, the operator
pantalla de operador. Administrador de transporte el
carriage would jump. Leaving the valve transporte Manager (CM) información basada en
insumos desde el administrador de altura en mástil
open until the motor stops diverts excess principal y Manager de alto Mini-Mast para limitar la
velocidad debido a la altura y a determinar el ascensor /
hydraulic fluid back to the Reservoir
menor "decel" puntos de la principal y Mini-Mast
10. The ESM reads the voltage from Pressure cuando casi sus extremos de movimiento. El CM
también utiliza la información de la ESM o TM para
Transducer A at JPA5-2 and sends this detener la reducción si se colgó la plataforma. El
Manager de transporte (CM) supervisa la entrada de
information over BUS+/BUS– to the CM.
elevar y descender potenciómetro (VR2) y envía las
The CM processes this information and solicitudes de elevar y descender a la TM en BUS + /
BUS–. El CM recibe información de número de la altura
sends it to the Operator Display to show de los administradores de altura y calcula los valores de
los administradores de altura con respecto al valor del
weight in pounds or kilograms. The CM
punto de referencia (posición completamente reducido).
also uses this information to determine El CM, a continuación, actualiza la indicación de la
altura de OD. El CM utiliza la información de ESM para
error codes and operational restrictions. actualizar el OD por indicación de peso. Parafina cadena
cambiar cuando el conmutador de parafina cadena está
11. The CM determines the height and abierto o el transductor de presión no sentidos presión,
direction of carriage movement by ascensor está limitada a un máximo de 23.6 pulgadas
(600 mm) para que el operador puede corregir una
summing the inputs from the Main Height plataforma hung-up y eliminar la holgura de la cadena.
Si no corrige la condición de cadena de holgura, dejará
Manager and the Mini Height Manager. la posibilidad de levantar. Ascensor principal con la
tecla interruptor ON y el Pedal derecho Deadman
deprimido, mover el mando de control de pulgar
ascensor/bajo Control (VR2) en la mano derecha Control
manejar hacia la derecha hace lo siguiente que se
El Manejador de dirección electrico (ESM) informa de la produzca: 1. VR2 el voltaje a la CM en 10 JPC24
tensión de los principales y transductores de presión disminuye a un voltaje de salida inferior en posición
Mini-Mast. Envía esta información sobre BUS + / BUS– neutral. 2. La CM, detectar esta disminución de la
cm para la generación de códigos de avería relacionada tensión, determina que se ha presentado una solicitud de
con el peso, las restricciones operacionales e ascensor. Para ello, comparando el voltaje de entrada
información se envíe a la pantalla de operador. con los valores de tensión aprendidas de ascensor,
Administrador de altura - mástil principal un Sensor inferior y neutral. El CM procesa este voltaje y envía un
óptico infrarrojo suministra insumos al administrador mensaje a través de BUS + / BUS– a la TM/VFC. 3. La
principal de altura. El administrador de altura del mástil TM/VFC recibe el mensaje y proporciona una tensión
principal envía información sobre BUS + / BUS– cm PWM (P CONTROL) a la tarjeta de bobina Driver 3
para la generación de códigos de avería relacionados con (CD3) en JPS12-2, que permite al controlador de bobina
la altura, las restricciones operacionales e información Contactor P. 4. Con el conductor de la bobina Contactor
para enviar a la pantalla de operador (OD). P energizado, la bobina del Contactor P tiene una ruta de
Administrador de altura - Sensor de proximidad Mini- acceso a terreno de JPS29-3, a través del controlador de
Mast A moderna suministra insumos al administrador de bobina JPS12-9, a través de FU12 para PC de B JPS14-1
y JPS14-2. Esto energiza la bobina del Contactor P, mayor voltaje de solicitud de ascensor, que además se
cerrando las puntas de contactor p e iniciar el motor de cierra la válvula y puertos más fluido hidráulico a los
la bomba de elevación. Modelos SA S/N > 03217 y SB cilindros de levante de mástil principal. 8. El fluido
S/N > 00761 tienen un volcado de válvula solenoide hidráulico fluye a través de la elevación seleccione
(SOL99) instalado. La configuración "dmp vlv" en el Electroválvula (SOL3) y la principal carga con válvula
modo de configurar debe establecerse ON para camiones solenoide (so11) a los cilindros de Levante. 9. La TM
equipados con SOL99 y desactivado para todos los supervisa el voltaje en punta de Contactor P P-2 a través
demás. La válvula de SOL99 normalmente abierta tiene de la línea P-sentido en JPS14-7. TM/VFC utiliza esta
su bobina con cables en paralelo con la bobina del información para determinar si las puntas P Contactor
Contactor P. El controlador de bobina Contactor P es están abiertas o cerradas. En camiones, no tener el
vigorizado (válvula cerrado). Con SOL99 bobina volcado de válvula solenoide (SOL99) instalado
energizado (válvula cerrado), la salida de levantar la (modelos SA S/N < 03218 y SB S/N < 00762), cuando
bomba es disponible para el sistema de elevación se quita la solicitud de elevación (VR2 regresó a la
durante una función de elevación. Cuando se quita la posición neutra), la bobina del Contactor de p es de-
solicitud de elevación, la bobina del Contactor P se energized inmediatamente, pero la válvula de solenoide
desconecta, junto con la bobina de SOL99, devolver la proporcional de ascensor/inferior (SOL4) se mantiene
válvula a su estado normalmente abierto. Esto totalmente vigorizado (abierto) hasta levantar Motor deja
proporciona una ruta hacia el embalse de la bomba de de inflexión. Ello porque un motor de giro no se detiene
elevación de salida, resultando en el alivio rápido de la al instante. Debido a la tensión (back EMF) producida en
bomba de presión al sistema, lo que reduce el retraso de el Motor de levantar como que gira a una parada, la línea
la transición entre un ascensor para disminuir la función. P-sentido tiene cierta tensión en él. TM/VFC supervisa
5. La TM/VFC también suministra una tensión PWM la línea P-sentido (JPS14-7) para determinar cuando el
para el controlador de bobina de elevar y descender ascensor Motor ha dejado torneado (no más back EMF
Electroválvula proporcional (SOL4) JPS11-4, producido). En ese momento TM/VFC desactiva (cierra)
permitiendo el bobina Electroválvula proporcional de el controlador de bobina Electroválvula proporcional de
elevar y descender al conductor. 6. Con el conductor de elevar y descender. Si el controlador de bobina
la bobina Electroválvula proporcional de elevar y Electroválvula proporcional de ascensor/inferior se de-
descender energizado, SOL4 tiene una ruta de acceso a energized a la vez que la bobina del Contactor P, podría
terreno de JPS19-4, al conductor de la bobina en JPS11- saltar al transporte de operador. Dejando la válvula
9, a través del controlador de bobina JPS11-11, a través abierta hasta el motor deje desvía back exceso de fluido
de FU-12 para PC de B JPS14-1 y JPS14-2. 7. La hidráulico al embalse de 10. ESM Lee el voltaje del
electroválvula proporcional de elevar y descender transductor de presión A JPA5-2 y envía esta
inicialmente se mueve a la posición completamente información a través de BUS + / BUS– a la CM. El CM
abierta, dirigir todo el flujo de fluido hidráulico hacia el procesa esta información y la envía a la pantalla de
embalse hidráulico. Luego posiciones operador para mostrar el peso en libras o kilogramos. El
proporcionalmente a la tensión de la solicitud de CM también utiliza esta información para determinar los
elevación de VR2. Al menos la tensión de solicitud de códigos de error y restricciones operacionales. 11. La
ascensor, más abierta la válvula solenoide proporcional CM determina la altura y la dirección del movimiento de
de elevar y descender será, permitiendo más fluido para transporte mediante la suma de las aportaciones de la
volver al embalse, resultando en un ritmo más lento del principal altura Manager y el Manager de altura
ascensor. Un ritmo más rápido de ascensor requiere un

de Mini.