▪ Malaysia wind speed map
) ( C pe )
2 2
p = 0.613 (V s ) ( Mz ,cat − C pi
where:
p = The design wind pressure in Pa
Vs = The basic wind speed (Figure A1)
Mz ,cat = The terrain/height multiplier (Table A1)
C pe = The external pressure coefficient for surface of enclose
building (A2.3 and A2.4)
C pi = The internal pressure coefficient for surface of enclose
building which shall be taken as +0.6 or -0.3. The two
cases shall be considered to determinate the critical load
requirements for the appropriate condition.
A3 B3 C3 D3
1.2WK
A2 B2 C2 D2
1.2WK
A1 B1 C1 D1
1.2WK
▪ Lateral load
of wind load
+
A3 B3 C3 D3
▪ Vertical load
due to wind A2 B2 C2 D2
pressure 1.2GK +1.2QK 1.2GK +1.2QK 1.2GK +1.2QK
A1 B1 C1 D1
26
0.65 x [(4+5)/2]
First Floor