PVsyst - Simulation report
Grid-Connected System
Project: LAGHOUAT500
Variant: Nouvelle variante de simulation
Sheds, single array
System power: 8.40 kWp
PVsyst TRIAL
PVsyst TRIAL
Author
PVsyst TRIAL
Project: LAGHOUAT500
Variant: Nouvelle variante de simulation
PVsyst V7.2.21
VC1, Simulation date:
21/05/23 22:23
PVsyst TRIAL
with v7.2.21
Project summary
Geographical Site Situation Project settings
Laghouat Latitude 33.80 °N Albedo 0.20
Algeria Longitude 2.87 °E
Altitude 763 m
Time zone UTC+1
Meteo data
Laghouat
NASA-SSE satellite data 1983-2005 - Synthétique
System summary
PVsyst TRIAL
Grid-Connected System Sheds, single array
Simulation for year no 20
System information
PV Array Inverters Battery pack
Nb. of modules 28 units Nb. of units 1 unit Storage strategy: Self-consumption
Pnom total 8.40 kWp Pnom total 8.00 kWac Nb. of units 14 units
Pnom ratio 1.050 Voltage 48 V
Capacity 1680 Ah
PVsyst TRIAL
Results summary
Produced Energy 12.57 MWh/year Specific production 1497 kWh/kWp/year Perf. Ratio PR 72.21 %
Used Energy 4.81 MWh/year Solar Fraction SF 100.00 %
Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Horizon definition 5
Near shading definition - Iso-shadings diagram 6
Detailed User's needs 7
Main results 8
Loss diagram 9
Special graphs 10
PVsyst TRIAL
CO₂ Emission Balance 11
PVsyst TRIAL
21/05/23 PVsyst Evaluation mode Page 2/11
Project: LAGHOUAT500
Variant: Nouvelle variante de simulation
PVsyst V7.2.21
VC1, Simulation date:
21/05/23 22:23
PVsyst TRIAL
with v7.2.21
General parameters
Grid-Connected System Sheds, single array
PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane Nb. of sheds 2 units Transposition Perez
Tilt/Azimuth 35 / 0 ° Single array Diffuse Perez, Meteonorm
Sizes Circumsolar separate
Sheds spacing 6.00 m
Collector width 2.00 m
Ground Cov. Ratio (GCR) 33.4 %
Top inactive band 0.02 m
PVsyst TRIAL
Bottom inactive band 0.02 m
Shading limit angle
Limit profile angle 15.0 °
Storage
Kind Self-consumption
Charging strategy Discharging strategy
When excess solar power is available As soon as power is needed
PV Array Characteristics
PVsyst TRIAL
PV module Inverter
Manufacturer Generic Manufacturer Generic
Model TDB156X156-72-P 300W Model SOFAR 8.8KTL-X
(Original PVsyst database) (Original PVsyst database)
Unit Nom. Power 300 Wp Unit Nom. Power 8.00 kWac
Number of PV modules 28 units Number of inverters 2 * MPPT 50% 1 unit
Nominal (STC) 8.40 kWp Total power 8.0 kWac
Modules 2 Strings x 14 In series Operating voltage 160-960 V
At operating cond. (50°C) Max. power (=>25°C) 8.80 kWac
Pmpp 7.40 kWp Pnom ratio (DC:AC) 1.05
U mpp 451 V
I mpp 16 A
PVsyst TRIAL
Total 28 modules Number of inverters 1 unit
Module area 54.4 m² Pnom ratio 1.05
Cell area 48.2 m²
Battery Storage
Battery
Manufacturer Generic
Model KBM216_2P13S 120Ah
Battery pack Battery Pack Characteristics
Nb. of units 14 in parallel Voltage 48 V
Discharging min. SOC 20.0 % Nominal Capacity 1680 Ah (C10)
Stored energy 64.0 kWh Temperature Fixed 20 °C
PVsyst TRIAL
21/05/23 PVsyst Evaluation mode Page 3/11
Project: LAGHOUAT500
Variant: Nouvelle variante de simulation
PVsyst V7.2.21
VC1, Simulation date:
21/05/23 22:23
PVsyst TRIAL
with v7.2.21
PV Array Characteristics
Battery Storage
Battery input charger
Model Generic
Max. charg. power 6.2 kWdc
Max./Euro effic. 97.0/95.0 %
Battery to Grid inverter
Model Generic
Max. disch. power 1.4 kWac
Max./Euro effic. 97.0/95.0 %
Array losses
PVsyst TRIAL
Thermal Loss factor
Module temperature according to irradiance
Uc (const)
Uv (wind)
0.5 %
DC wiring losses
Global array res.
Loss Fraction
2.0 % at MPP
LID - Light Induced Degradation
Loss Fraction
0.1 %
PVsyst TRIAL
Inv. output line up to injection point
Inverter voltage
Loss Fraction
Inverter: SOFAR 8.8KTL-X
Wire section (1 Inv.)
400 Vac tri
0.77 % at STC
Copper 1 x 3 x 3 mm²
AC wiring losses
Wires length 20 m
PVsyst TRIAL
PVsyst TRIAL
21/05/23 PVsyst Evaluation mode Page 4/11
Project: LAGHOUAT500
Variant: Nouvelle variante de simulation
PVsyst V7.2.21
VC1, Simulation date:
21/05/23 22:23
PVsyst TRIAL
with v7.2.21
Horizon definition
Horizon from PVGIS website API, Lat=33°48"0', Long=2°51"54', Alt=763m
Horizon profile
Azimuth [°] -180 -173 -165 -158 -143 -135 -75 -68 -60 -53 -45
Height [°] 1.1 0.8 0.8 1.1 1.1 1.5 1.5 2.7 3.8 3.8 3.4
Azimuth [°] -38 -30 -23 -15 -8 0 38 45 53 60 68
Height [°] 3.4 3.1 2.7 1.9 1.5 1.1 1.1 0.4 0.8 0.8 1.1
Azimuth [°] 75 83 98 105 128 135 143 173 180
PVsyst TRIAL
Height [°] 1.1 1.9 1.9 2.3 2.3 1.9 1.5 1.5 1.1
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
21/05/23 PVsyst Evaluation mode Page 5/11
Project: LAGHOUAT500
Variant: Nouvelle variante de simulation
PVsyst V7.2.21
VC1, Simulation date:
21/05/23 22:23
PVsyst TRIAL
with v7.2.21
PVsyst TRIAL
Iso-shadings diagram
PVsyst TRIAL
Orientation #1
PVsyst TRIAL
PVsyst TRIAL
21/05/23 PVsyst Evaluation mode Page 6/11
Project: LAGHOUAT500
Variant: Nouvelle variante de simulation
PVsyst V7.2.21
VC1, Simulation date:
21/05/23 22:23
PVsyst TRIAL
with v7.2.21
Summer 0h 1h 2h 3h 4h 5h 6h 7h 8h 9h 10 h 11 h
1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 kW
12 h 13 h 14 h 15 h 16 h 17 h 18 h 19 h 20 h 21 h 22 h 23 h
1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 1.02 kW
Autumn 0h 1h 2h 3h 4h 5h 6h 7h 8h 9h 10 h 11 h
0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 kW
12 h 13 h 14 h 15 h 16 h 17 h 18 h 19 h 20 h 21 h 22 h 23 h
0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 0.17 kW
Winter 0h 1h 2h 3h 4h 5h 6h 7h 8h 9h 10 h 11 h
PVsyst TRIAL
0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 kW
12 h 13 h 14 h 15 h 16 h 17 h 18 h 19 h 20 h 21 h 22 h 23 h
0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 kW
Spring 0h 1h 2h 3h 4h 5h 6h 7h 8h 9h 10 h 11 h
0.81 0.81 0.81 0.81 0.81 0.81 0.81 0.81 0.81 0.81 0.81 0.81 kW
12 h 13 h 14 h 15 h 16 h 17 h 18 h 19 h 20 h 21 h 22 h 23 h
0.81 0.81 0.81 0.81 0.81 0.81 0.81 0.81 0.81 0.81 0.81 0.81 kW
PVsyst TRIAL
Winter (Dec-Feb) Spring (Mar-May)
PVsyst TRIAL
PVsyst TRIAL
21/05/23 PVsyst Evaluation mode Page 7/11
Project: LAGHOUAT500
Variant: Nouvelle variante de simulation
PVsyst V7.2.21
VC1, Simulation date:
21/05/23 22:23
PVsyst TRIAL
with v7.2.21
Main results
System Production
Produced Energy 12.57 MWh/year Specific production 1497 kWh/kWp/year
Used Energy 4.81 MWh/year Performance Ratio PR 72.21 %
Solar Fraction SF 100.00 %
Battery aging (State of Wear)
Cycles SOW 95.0 %
Static SOW 90.0 %
PVsyst TRIAL
Balances and main results
PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
89.9
109.2
153.5
181.2
DiffHor
kWh/m²
28.83
31.92
46.81
54.90
T_Amb
°C
6.62
8.83
12.55
16.37
GlobInc
kWh/m²
146.0
156.0
187.5
190.1
GlobEff
kWh/m²
139.6
151.0
181.6
182.9
EArray
MWh
0.992
1.054
1.242
1.229
E_User
MWh
0.135
0.122
0.599
0.580
E_Solar
MWh
0.135
0.122
0.599
0.580
E_Grid
MWh
0.782
0.892
0.578
0.586
EFrGrid
MWh
0.000
0.000
0.000
0.000
May 205.5 65.41 21.60 192.1 184.2 1.212 0.599 0.599 0.547 0.000
June 208.2 65.70 26.91 184.2 176.2 1.127 0.736 0.736 0.322 0.000
July 217.6 63.86 30.17 198.4 190.3 1.191 0.760 0.760 0.350 0.000
August 189.7 60.76 29.56 190.6 183.4 1.150 0.760 0.760 0.313 0.000
September 158.4 48.90 24.54 183.4 177.4 1.147 0.125 0.125 0.974 0.000
October 124.0 40.92 18.70 166.5 161.1 1.074 0.129 0.129 0.903 0.000
November 90.9 30.60 12.44 140.4 135.4 0.935 0.125 0.125 0.771 0.000
PVsyst TRIAL
December 81.2 26.97 7.96 137.2 130.8 0.923 0.135 0.135 0.747 0.000
Year 1809.3 565.58 18.07 2072.6 1994.0 13.274 4.807 4.807 7.765 0.000
Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_User Energy supplied to the user
T_Amb Ambient Temperature E_Solar Energy from the sun
GlobInc Global incident in coll. plane E_Grid Energy injected into grid
GlobEff Effective Global, corr. for IAM and shadings EFrGrid Energy from the grid
PVsyst TRIAL
21/05/23 PVsyst Evaluation mode Page 8/11
Project: LAGHOUAT500
Variant: Nouvelle variante de simulation
PVsyst V7.2.21
VC1, Simulation date:
21/05/23 22:23
PVsyst TRIAL
with v7.2.21
Loss diagram
1809 kWh/m² Global horizontal irradiation
+14.6% Global incident in coll. plane
-7.80%
-0.37%
-7.52%
Array nominal energy (at STC effic.)
PVsyst TRIAL
13.27 MWh Array virtual energy at MPP
-1.91% Inverter Loss during operation (efficiency)
0.00% Inverter Loss over nominal inv. power
0.00% Inverter Loss due to max. input current
0.00% Inverter Loss over nominal inv. voltage
-0.02% Inverter Loss due to power threshold
0.00% Inverter Loss due to voltage threshold
13.02 MWh Available Energy at Inverter Output
PVsyst TRIAL
-0.99% Battery IN, charger loss
Stored Direct use
grid Battery Storage
23.4% 76.6%
consumption -1.08% Battery global loss
(4.79% of the battery contribution)
-1.00% Battery OUT, inverter loss
PVsyst TRIAL
21/05/23 PVsyst Evaluation mode Page 9/11
Project: LAGHOUAT500
Variant: Nouvelle variante de simulation
PVsyst V7.2.21
VC1, Simulation date:
21/05/23 22:23
PVsyst TRIAL
with v7.2.21
Special graphs
Diagramme d'entrée/sortie journalier
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
21/05/23 PVsyst Evaluation mode Page 10/11
Project: LAGHOUAT500
Variant: Nouvelle variante de simulation
PVsyst V7.2.21
VC1, Simulation date:
21/05/23 22:23
PVsyst TRIAL
with v7.2.21
PVsyst TRIAL
System Lifecycle Emissions Details
PVsyst TRIAL
Inverters 0.66 kgCO2/ 1.00 0.66
PVsyst TRIAL
PVsyst TRIAL
21/05/23 PVsyst Evaluation mode Page 11/11