Professional Documents
Culture Documents
Exam 2
Exam 2
19. The DC measuring system gives voltage and current indication located in ?
a. Overhead Panel
b. Electrical Panel
c. L/H maintenance panel
d. R/H maintenance panel
20. What is indication if inverter No 1 Fault :
a. “Bus Off” light illuminate on main electrical panel
b. “Bus Off” light extinguishers
c. “Bus Off” light extinguishers after 10 seconds later “Inv Fault” light illuminate on main
electrical power panel
d. “Inv Fault” light illuminate
21. The DC ground handling bus can be powered by :
a. Main battery
b. Emergency battery
c. DC external power
d. A and C correct
22. Basic mode on Batt switch is selected “ON” the main battery will supplies the :
a. DC bus 1
b. Hot emergency bus
c. The Stby Bus and inverter no 1 through the hot main battery bus.
d. Emergency bus and Ess bus
23. Feeder overheat will be indicated during a/c on ground and controlled by ?
a. FODU
b. MFC
c. BPCU
d. GCU
24. Which inverter powers AC bus 1 :
a. No 1 inverter only
b. No 2 inverter only
c. Normally by the no 1 inverter, the no 2 inverter can be automatically power at through
the AC Btr.
d. Either inverter but only if the DC battery push-button has ISOL illuminated
25. What is indication external power plug in on the aircraft :
a. The “Avail” light on the overhead panel illuminate
b. The “On” blue light on the cockpit illuminate
c. DC Power Not Use light extinguishes
d. DC Cntd on the external power panel illuminate
26. What is indication that battery are discharging ?
a. Amber arrows on LH maintenance panel
b. Amber arrows on Main elect panel
c. Disch light on the CAP
d. All above are correct
27. Main or emergency battery overheat is indicate :
a. By a red battery Ovht on the CAP
b. By one of the LH maintenance panel
c. On the relevant battery temp indicator
d. By an amber Fault light in one of the battery charge push button
28. Where is location two Generator Control Unit (GCU) :
a. On the aux gear box
b. On the reduct gear box
c. In the RH electrical racks 90 VU
d. In the LH avionic racks 80 VU
29. On push button starter panel “ON” light not illuminate during press in, what is the problem ?
a. Starter generator fault
b. GCU detection open circuit in the starter contactor
c. BPCU detection open circuit in the starter contactor
d. GCU detection generator undervolatge
30. During in flight dual DC generator fault, the TRU should be ON for supply :
a. DC emergency bus
b. DC ess bus
c. DC bus 1
d. A and B correct
31. Where is location battery charger indication :
a. LH maintenance panel
b. RH maintenance panel
c. Overhead Panel
d. No indication in the cockpit
32. A speed sensor incorporated in the DC starter/generator send a speed reference to the
associated GCU for the starter cut-out point :
a. 25% NH
b. 45% NH
c. 45% NP
d. 61.5% NH
33. Where is location main and emergency battery ?
a. On the floor of the electrical racks
b. On the floor of the avionic racks
c. On the floor in cargo compartment
d. Nose L/G bay area
34. Ground handling bus is automatically supplied by main battery through :
a. Ess bus 2
b. Hot main batt bus
c. Service bus
d. Hot emergency bus
35. During A/C on ground, the service bus and ground handling bus can be supplied from :
a. Battery
b. External power
c. Generator during engine run with external power connected
d. A and B correct
36. No Ext Power Available, does operation Hotel Mode provide power for the ACW system ?
a. Yes
b. No
c. Yes with Eng 2 CL at Max RPM
37. A/C on ground, Engine running, DC ext power AVAIL and on line ?
a. DC Ext PWR has no priority over Eng DC Gen
b. DC Ext PWR has priority over Eng DC Gen
c. The first on line has priority
38. In the ACW system, how any BTC are used ?
a. One BTC and one BTC Pb
b. Two BTC and one BTC Pb
c. Two BTC and two BTC Pb
39. The UNDV light illuminate amber when ?
a. DC Stby Bus voltage is lower than 19.5 volt
b. Battery voltage is below 26.5 volt
c. ACW gen voltage below 115 volt
40. When an inverter failure, INVT illuminate ?
a. Associated ac bus is lost
b. Associated ac bus is supply through the AC STBY Bus
c. Associated ac bus is supplied through the ac btr by the other inverter
41. The DC BTC is automatically closed and the flow bar is illuminate in case of ?
a. External power operation
b. Hotel mode operation
c. Ext pwr operation, hotel mode operation, single engine operation
42. DC Service and Utility bus shed amber light come on when ?
a. Utility bus 1 and utility bus 2 are shed
b. At least one utility bus is disconnected from associated main DC Bus
c. Corresponding DC service and Utility bus push button is pugh off
43. When emergency light will illuminate :
a. Switch in Arm position and one DC gen fail
b. Switch in Arm position and Essential bus drop bellow 18 V
c. Switch in Arm position and Stby bus drop bellow 18 V
d. Switch in Arm position
44. Chose the correct statement
a. Strobe light power supply by DC an has 60 flashes per minutes
b. Beacon light power supply by ACW and has 60 Flashes per minutes
c. Strobe light power supply by ACW
d. Strobe light power supply by DC
45. Ice evidence will illuminate associated with:
a. Beacon light
b. Taxi and T/O light
c. Navigation light
d. Strobe light
46. Switch ON No Smoking an Seat Belt Sign will be follow by:
a. No smoking and seat belt sign in the CAP
b. No smoking and seat belt sign in the memo panel
c. No smoking and seat belt sign in the F/A Panel
d. All incorrect
47. Lavatory light (normal light) will be illuminate withj following condition below:
a. Battery “ON”
b. GPU available lavatory door open
c. GPU available lavatory door closed and locked
d. All above are true