Dual monitoring system
The FS-V10 Series features both a digital LED indicator, which numerically displays the received light intensity, and a bar LED, which shows the level of detection stability (excess gain). The digital LED indicator can be used to align the optical axis and to display operating conditions during sensor mounting. The bar LED indicates detection stability during operation.
FS01 Series
Features
q q q q q An Industry-first dual monitoring system Auto and manual calibration 20-bit concurrent processing chip High accuracy and high power Wire-saving 0-line or 1-line connection system
Detecting Distance
Thrubeam Up to 3,600 mm (with lens)
The digital LED indicator is a powerful aid for optical axis alignment.
Diffuse-reflective Up to 300 mm
Definite-reflective Up to 14 mm
By button
No good
By trimmer
Calibration requires No experience. Good good Settings vary depending on the operator. Just press the button for fully Good Good automatic calibration.
By hybrid calibration
<FS-V10 Series>
Automatic SET button MODE selector button Manual calibration button Digital LED Bar-graph LED
NEW 20-bit concurrent processing chip + 12-bit A/D converter The FS-V10 Series features a newly developed 20-bit concurrent processing chip. This chip can concurrently process 12 types of control including high-speed calculation of received light intensity, dual monitor display, and peak/bottom hold display. Compared to general-purpose CPUs for sequential processing, this chip offers various advantages such as low current consumption, high-speed response, and reduced heat value, resulting in the improvement of overall usability.
54
FS01
Amplifier Variations
Fibreoptic sensors FS01 Series
Hybrid Calibration Type: FS-V10 Series Dual monitoring function with bar LED and digital display Hybrid calibration with Auto SET button and manual adjustment button One-touch Calibration Type: FS-T Series Fully-automatic calibration by pressing a button Green LED light source model FS-T1G is also available
1 2 3 4 5 6 7 8 9
High accuracy detection: Detects down to 0.01 mm dia wire with thrubeam unit High power intensity: Detects target at the industry longest 300 mm distance with reflective unit Wire-saving connection: 1-line connection system reduces the wiring labour to 1/2 of conventional method Compact size with 9-mm thickness: Installing several units requires very small space.
1.
2.
2.
3.
5.
4.
2 independent outputs
One unit works as two separate amplifiers
7.
8.
Video Microscope
5.
6.
Technical Guide
FS-M2
Digital Calibration Type: FS-V1 Series Digital monitor function and 2 independent outputs Control and adjustment function for 1-line expansion units
Pressure Sensors
Manual Calibration Type: FS-M Series Fine adjustment in calibration by using a multi-turn trimmer Ultra-high-speed response model FS-M1H is also available
Proximity Sensors
10 11 12 13 14
55
The FS-V10 Series offers three levels of detection to suit the application.
56
Photoelectric Sensors
Model: FU-66
The FS-V10 Series can be used for high-precision detection of wire as thin as 0.01 mm in diameter with a thrubeam type fibre unit. It can also be used for detection in harsh environments where oil or dust exists. Because the FS-V10 Series can work in almost all applications, sensor selection is easy.
FS01
Unstable operating conditions can be discovered at a glance using Bar LED indicators
The bar LED indicates detection stability using a 7-level bar LED. The bar LED shows when maintenance is required at a glance, which is difficult to notice with the digital display.
Photoelectric Sensors
1 2 3 4 5 6 7 8 9
Low excess gain One LED does not light during light beam reception. That means the excess gain is +10%.
Inspection required Two LEDs do not light during light beam reception. That means the excess gain is +5%. An immediate inspection is required.
The FS-V10 Series uses the KEYENCEs unique 1-line system. Power is supplied from the main unit (FS-V11) through the expansion connector so that the expansion units (FS-V12) do not require power cables. When 10 units are used Conventional system
SET SET SET SET SET SET SET SET SET SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
No. of terminal blocks 20 pairs No. of wires 58 No. of crossover wires 8 Man-hours 120 minutes Approx.
1-line system
No. of terminal blocks 12 pairs No. of wires 24 No. of crossover wires 0 Man-hours 50 minutes Approx.
LOCK
OFF.D ON.D OFF L.ON D.ON
LOCK
OFF.D ON.D OFF L.ON D.ON
LOCK
OFF.D ON.D OFF L.ON D.ON
LOCK
OFF.D ON.D OFF L.ON D.ON
LOCK
OFF.D ON.D OFF L.ON D.ON
LOCK
OFF.D ON.D OFF L.ON D.ON
LOCK
OFF.D ON.D OFF L.ON D.ON
LOCK
OFF.D ON.D OFF L.ON D.ON
LOCK
OFF.D ON.D OFF L.ON D.ON
LOCK
OFF.D ON.D OFF L.ON D.ON
FS-T1
FS-T1
FS-T1
FS-T1
FS-T1
FS-T1
FS-T1
FS-T1
FS-T1
FS-T1
Space advantage
In TURBO/SUPER TURBO mode, up to 8 units can be mounted side-by-side without mutual interference. (In FINE mode, up to 4 units)
Video Microscope
Technical Guide
Vision Systems
Pressure Sensors
Proximity Sensors
10 11 12 13 14
57
Hybrid calibration (One-touch + manual, digital) Main unit NPN PNP FS-V11 FS-V11P 1-line expansion unit FS-V12 FS-V12P Red LED 250 s (FINE)/500 s (TURBO )/1 ms (SUPER TURBO) 410 s to 1.7 ms 2. 0-line expansion unit FS-V10 1.
Digital calibration Main unit FS-V1 FS-V1P 250 s Output indicators: 2 Red LEDs Digital LCD monitor: LCD (Red/Green LED back-lit) Calibration indicator: Orange LED ON-delay: 40 ms/ OFF-delay: 40 ms/ Timer OFF (switch-selectable)
Operation mode
LIGHT-ON/DARK-ON (switch-selectable) Output indicator: Red LED Digital LED monitor: Red LED, 7-segment, 4-digit Bar graph LED monitor: Green/Orange LED 3. Calibration indicator: Orange LED 3.
Indicators
Timer function
Control output Protection circuit Power supply Current consumption Ambient illumination Ambient temperature Housing material Weight (including 2-m cable)
1. 2. 3. 4. 5.
NPN or PNP open-collector: 100 mA (40 V) max., Residual voltage: 1 V max. 4. Reverse polarity protection, over-current protection, surge absorber 12 to 24 VDC 10% 50 mA max. Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max. -10 to +55C 5. Body/Cover: Polycarbonate Approx. 80 g Approx. 45 g Approx. 20 g Approx. 80 g
FS-V10 has no output wire and FS-R0 should be used for issuing output. The response time varies depending on the number of expansion units connected. The orange LED is normally part of the bar graph LED monitor. It is used as a calibration indicator during the setting of the sensitivity. FS-V1 has 2 outputs. When several units are connected, the allowable ambient temperature changes depending on the following conditions. To connect several units, be sure to mount them to a DIN rail (metal DIN rail). Make sure that the output current is 20 mA max. When 3 to 10 units are connected: -10 to +50C, When 11 to 16 units are connected: -10 to +45C
FS-T Series
Type NPN PNP One-touch calibration Main unit FS-T1 FS-T1P Red LED 250 s Colour detection FS-T1G Green LED 250 s 1-line expansion unit FS-T2 FS-T2P Red LED 250 s 0-line expansion unit FS-T0 Red LED 410 s to 1 ms 1.
Operation mode Indicators Timer function External calibration input signal Control output Stability output Protection circuit Power supply Current consumption Ambient light Ambient temperature Housing Weight (including 2-m cable)
1. 2. 3. 4.
LIGHT-ON/DARK-ON (switch-selectable) Output indicator: Red LED, Stable operation indicator: Green LED, Calibration indicator: Orange LED ON-delay: 40 ms, OFF-delay: 40 ms, Timer OFF (switch-selectable) Non-voltage input (contact, solid state)
NPN or PNP:100 mA max. (40 V max.), Residual voltage: 1 V max. 2. NPN or PNP: 50 mA max. (40 V max.), Residual voltage: 1 V max. 3. Reversed polarity protection, over-current protection, surge absorber 12 to 24 VDC 10% 35 mA max. -10 to +55C 12 to 24 VDC 10% 35 mA max. -10 to +55C 12 to 24 VDC 10% 4. 35 mA max. -10 to +55C 12 to 24 VDC 10% 4. 35 mA max. -10 to +55C
Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max. Body/Cover: Polycarbonate Body/Cover: Polycarbonate Body/Cover: Polycarbonate Body/Cover: Polycarbonate Approx. 75 g Approx. 75 g Approx. 40 g Approx. 20 g
The response speed varies depending on the number of expansion units connected. The FS-T0/M0 have no control output. Only the FS-T1/M1 provide stability outputs. Stability outputs for the FS-T2/T0/M2/M0 are output from the FS-T1/M1 or FS-R0. Power to the FS-T2/T0/M2/M0 is supplied through the FS-V11/V1/T1/M1 or FS-R0.
58
FS01
FS-M Series
Manual calibration Type NPN PNP
Photoelectric Sensors Vision Systems Video Microscope Analog Sensor Controllers Technical Guide Thrubeam Measuring Displacement Sensors Instruments Bar Code Readers
1 2 3 4 5 6 7 8 9
8-turn trimmer (with indicator), FINE/TURBO (switch-selectable) 250 s (FINE), 500 s (TURBO) 250 s (FINE), 500 s (TURBO) 20 s (FINE), 50 s (TURBO) 410 s to 1.2 ms 1.
Response time Operation mode Indicators Timer function Control output Stability output Protection circuit Power supply Current consumption Ambient light Ambient temperature Housing Weight (including 2-m cable)
1. 2. 3. 4.
LIGHT-ON/DARK-ON (switch-selectable) Output indicator: Red LED, Stable operation indicator: Green LED ON-delay: 40 ms, OFF-delay: 40 ms, Timer OFF (switch-selectable) NPN or PNP:100 mA max. (40 V max.), Residual voltage: 1 V max. 2. NPN or PNP: 50 mA max. (40 V max.), Residual voltage: 1 V max. 3. Reversed polarity protection, over-current protection, surge absorber 12 to 24 VDC 10% 35 mA max. 12 to 24 VDC 10% 4. 35 mA max. 12 to 24 VDC 10% 35 mA max. 12 to 24 VDC 10% 4. 35 mA max.
Pressure Sensors High Precision Sensors Counters, Control Units Programmable Logic Controllers Proximity Sensors
Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max. -10 to +55C -10 to +55C -10 to +55C -10 to +55C
Body/Cover: Polycarbonate Body/Cover: Polycarbonate Body/Cover: Polycarbonate Body/Cover: Polycarbonate Approx. 75 g Approx. 40 g Approx. 20 g Approx. 20 g
The response speed varies depending on the number of expansion units connected. The FS-T0/M0 have no control output. Only the FS-T1/M1 provide stability outputs. Stability outputs for the FS-T2/T0/M2/M0 are output from the FS-T1/M1 or FS-R0. Power to the FS-T2/T0/M2/M0 is supplied through the FS-V11/V1/T1/M1 or FS-R0.
Amplifier Function
1-line connection amplifiers reduce wiring and labour
Up to 16 expansion units can be connected to a single main unit and can be freely combined.
FS-V11 :Hybrid calibration FS-V1 :Multi-functions and digital calibration FS-T1 :One-touch calibration FS-M1 :Manual calibration FS-T1G FS-M1H FS-V12 FS-T2 FS-M2 :Green LED light source :High-speed response :Hybrid calibration :One-touch calibration :Manual calibration
Main units
Expansion units
Connector unit
0-line expansion-units
Board
Input
FS-V12
FS-T2
FS-M2
FS-R0
FS-V10
FS-T0
FS-M0
FS-R3
10 11 12 13 14
59
Photoelectric Sensors
Standard Fibre
M6, reflective
M4, thrubeam
M4, reflective
M3, reflective
60
FS01
1 2 3 4 5 6 7 8 9
Compact Definite Reflective Fibres: FU-38/38V/38R These fibres are excellent for detection in tight spaces such as being embedded in a robot arm or on a conveyor. Detection is almost unaffected by target backgrounds.
Area Detection Fibre: FU-12 The FU-12, which provides a detecting area 10 mm wide, is suitable for detecting vibrating targets or minute targets. A target as small as 1.2 mm in diameter can be accurately detected.
Liquid Level Detection Fibre: FU-93 The FU-93 is totally encased in a Teflon-sheath. It is liquid resistant and can be used to reliably detect a liquid surface level.
Focused Beam Lens and Fibre: FU-21X + F-2HA The FU-21X with the F-2HA forms a tiny beam spot 0.2 mm in diameter at a detecting distance of 7 mm. This combination is very useful for detecting minute targets or positioning with high accuracy.
Video Microscope
Tube-mountable Liquid Level Detection Fibre: FU-95 The FU-95 is a liquid-level-detection fibre that can be easily mounted to a tube. Because it is lightweight it can be mounted in anywhere.
Narrow-beam Fibre: FU-22X The light diffusion angle is 10 (1/6 of conventional models), allowing narrow beam emission. This capability is ideal for detecting minute targets.
Technical Guide
Wafer Mapping Fibre: FU-18 The FU-18 incorporates a special lens and prism and has an aperture angle of 2 enabling ultra-narrow beam emission. This capability is well suited to mapping (positioning) wafers placed at a small pitch.
Long Detecting Distance, Side-view Fibre: FU-16 The FU-16 provides a long detecting distance of 1.7 m and an aperture angle of 6, enabling narrow beam emission. Almost no light reflected by surrounding objects enters the receiver, enabling stable detection.
Pressure Sensors
Proximity Sensors
10 11 12 13 14
61
Features
Weight
(Approx.)
Model FU-5F
19g
0.03 mm R25 mm Long-detecting distance
Freecut
Thrubeam
Diffuse-reflective
62
Photoelectric Sensors
M4
Standard
M4
Lens F-1, F-2, F-4 Lens F-1, F-2, F-4 0.03 mm R4 mm A minimum bend radius of 4 mm
21g
FU-7F
Freecut
9g
FU-78
Freecut
19g
570 (3000) 460 230 0.03 mm Lens F-1, F-2, F-4 R2 mm Break-free fibre
FU-5FZ
Freecut
M4
ToughFlex
M4
21g
FU-77
Freecut
R10 mm
39g
1.5 mm dia.
220
3g
0.01 mm R4 mm High-flex fibre
High-flex
M3
200 100
FU-79 6g
Freecut
150 120 75 760 640 320 500 400 250 1700 1300 800 1300 1000 650 80 60 30 250 200 100 1000 800 600
FU-75F
0.01 mm R10 mm Thin sleeve
10g
Freecut
Thin-sleeve
Min. bend radius of sleeve: 10 mm 1.65 mm dia. 4 mm dia. Min. bend radius of sleeve: 10 mm 4 mm dia.
Long-detecting distance with sleeve 0.03 mm R25 mm Narrow-beam type with built-in micro lens 0.1 mm R10 mm 0.1 mm Long-detecting distance side-view type Wafer-mapping type Side-view type with thin sleeve R25 mm 0.03 mm Space-saving, side-view type Area detection fibre with a detecting width of 10 mm
FU-73 24g
Freecut
11g
FU-36X FU-16
6g
Freecut
4 mm dia.
FU-18 8g
Freecut
Side-view
0.82 mm dia. 2.5 mm dia. Do not bend sleeve. 1.2 mm dia. 3 mm dia. Min. bend radius of sleeve: 25 mm
FU-32 5g
Freecut
0.01 mm
FU-34 17g
Freecut
Area detection
3 mm dia.
1.2 mm 3. 0.3 mm
FU-12 23g
Freecut
R2 mm
FU-4F 8g
300 200 100 0.01 mm (gold wire) R25 mm Long-detecting distance
Freecut
M6
FU-6F 21g
Freecut
Standard
M4
10g
SUPER TURBO TURBO FINE SUPER TURBO is for FS-V11/12/10 only. For FS-V1 and FS-T, see FINE.
FU-66
Freecut
1. Detecting range varies depending on detecting distance and target diameter. Refer to "Characteristics". Detecting distance for reflective sensors were obtained using a white paper target (standard target). 2. The smallest detectable object was determined at the optimal detecting distance and sensitivity setting. 3. Smallest detectable object is 1.2 mm in TURBO mode and 0.3 mm in FINE mode.
FS01
Type
Shape
3 mm dia.
Features
Weight
(Approx.)
4g
Suitable for positioning
M6
1 2 3 4 5 6 7 8 9
18g
R25 mm 0.2 mm spot diameter when used with F-2HA 0.4 mm spot diameter when used with F-2HA
Freecut
Coaxial
M3
12
M3
110 70 35
FU-35FA 6g
Freecut
3 mm dia.
FU-4FZ
130 80 45
Freecut
M4
0.01 mm
(gold wire)
R2 mm
Break-free fibre
FU-66Z 10g
Freecut
FU-67
180 130
21g
Armoored ToughFlex fibre Coaxial fibre with 0.4 mm spot diameter when used with F-2HA Thin sleeve break-free fibre
Freecut
ToughFlex
65
0.01 mm
R10 mm
29g
M3
65 45 25 45 35 20
6g
0.01 mm
(gold wire)
R2 mm
Diffuse-reflective
10g
FU-63Z
Freecut
FU-48
55 40
M4
25 0.01 mm
(gold wire)
FU-68 8g
R4 mm High-flex fibre
Freecut
High-flex
1.5 mm dia.
25 20
M3
3g
FU-49x
15
3g
Narrow-beam type for small-beam spot
FU-69X
1.77 mm dia. 2.5 mm dia. Do not bend sleeve. 0.82 mm dia. 3 mm dia. Do not bend sleeve. 0.82 mm dia. M3 Do not bend sleeve. 1.65 mm dia. 4 mm dia.
12 10 8
R25 mm
4g
FU-22X
14 10 6 R4 mm
4g
FU-45X
5g
FU-65X FU-43
Freecut
Thin-sleeve
0.01 mm
(gold wire)
Do not bend sleeve. 1.65 mm dia. M4 Min. bend radius of sleeve: 10 mm 1.65 mm dia. Min. bend radius of sleeve: 10 mm 4.8 mm dia. 2.1 mm dia.
8g
R25 mm
Screw-mount type
10g
FU-63
Freecut
FU-63T 10g
Freecut
R25 mm 0.03 mm
(copper wire)
Long-sleeve
10g
FU-33
Freecut
Side-view
Min. bend radius of sleeve: 25 mm 2.8 mm dia. 2.0 mm dia. Do not bend sleeve.
R10 mm
Compact
5g
FU-31
Freecut
SUPER TURBO
TURBO
SUPER TURBO is for FS-V11/12/10 only. For FS-V1 and FS-T, see FINE.
1. Detecting distance for reflective sensors were obtained using a white paper target (standard target). 2. The smallest detectable object was determined at the optimal detecting distance and sensitivity setting.
7g
Freecut
1.65 mm dia. M4
M6
Pressure Sensors
M6
Proximity Sensors
8g
28 20
Lens F-2HA
4g
FU-21X
10 11 12 13 14
63
Type
Shape
Features
Weight
(Approx.)
Model FU-37
6g
0.01 mm
(gold wire)
Definite-reflective
R10 mm
Freecut
Diffuse-reflective
Thrubeam
64
Photoelectric Sensors
5g
Almost unaffected by target background, side-by-side detection available Almost unaffected by target colour and background, longdetecting distance For mounting to a tube Liquid level detection by sensor head immersion. Teflon-sheathed
Liquid level detection by sensor head immersion. Teflon covered for high durability against chemicals. FU-94C heat resistant up to 200C
FU-38
Freecut
Definitereflective
0.08 mm
(copper wire)
FU-38V 5g
Freecut
0.3 mm
(gold wire)
FU-38R 20g
Freecut
R25 mm
R10 mm
7g
FU-95
Freecut
Liquid-level
Liquid (except for milky white liquids)
R40 mm (Teflon part)
78g
FU-93
Freecut
90g
FU-94C
2.1 mm dia. M4
180 120 60
Heat resistance: 350C, glass fibre with sleeve R25 mm Heat resistance: 300C, glass fibre with sleeve Heat resistance: 300C, glass fibre Heat resistance: 105C, plastic fibre Heat resistance: 180C, plastic fibre
24g
FU-81C
2.1 mm dia.
M4
210 140
29g
FU-82C
Heatresistant
M4
70
0.01 mm
(gold wire)
23g
FU-83C FU-85
M6
21g
Freecut
M6
FU-87 33g
Freecut
4.5 mm dia.
0.01 mm
(gold wire)
R40 mm
Teflon fibre
32g
FU-91
Freecut
M4
66g
FU-84C FU-86
Freecut
Heatresistant
M4
320
M4
Heat resistance: 105C, plastic fibre Heat resistance: 180C, plastic fibre
22g
36g
FU-88
Freecut
200
5 mm dia.
FU-92
0.2 mm R40 mm 0.1 mm Teflon fibre, side-view type Teflon fibre
71g
1100
5 mm dia.
Freecut
FU-96 71g
Freecut
SUPER TURBO
TURBO
FINE
SUPER TURBO is for FS-V11/12/10 only. For FS-V1 and FS-T, see FINE.
1. Detecting range varies depending on detecting distance and target diameter. Refer to "Characteristics". Detecting distance for reflective sensors were obtained using a white paper target (standard target). 2. The smallest detectable object was determined at the optimal detecting distance and sensitivity setting.
FS01
Selection Chart
Lens attachment
Type Configuration Applicable Detecting distance (mm) fibre units FINE TURBO SUPER TURBO FU-7F,86 FU-77, 77G Side-view FU-78 FU-84C 400 260 220 220 1800 1500 1200 1500 3000 2500 2000 800 540 440 440 3600 3000 2400 3000 3600
2.
Feature Model
Model
Photoelectric Sensors Vision Systems
1000 670 Space-saving, side-view type 550 550 36002. 3600 3000 3600 36002. Greatly increases the detecting distance. Aperture angle: 8 NEW F-4 Greatly increases the detecting distance., Aperture angle: 15 F-2 F-11.
1 2 3 4 5 6 7 8 9
Thrubeam
FU-7F,86 Long-detecting distance FU-77, 77G FU-78 FU-84C FU-7F Ultra-long detecting distance FU-77, 77G FU-78
Diffuse-reflective
Focusing lens FU-21X Long-detecting distance, focusing lens Long-detecting distance, high focusing lens
7 2 with beam spot diameter of 0.2 mm Focuses light beam for precise aiming. Improves the stability for the minute target detection.
F-2HA
FU-35FA(Z) 0 to 20 with beam spot diameter of 4 mm 15 2 with beam spot diameter of 0.5 mm
F-3HA
1. When using the F-1 at a temperature of 70C or more, specify the "Heat-resistant F-1". 2. "3600" is assumed as maximum because the fibre cable has the length of 2 m.
Specifications
Fibre unit
Type Standard 350C type -40 to +70C (FU-12, 67, 77: -40 to +50C, FU-39: -30 to +100C) Fibre: Plastic, Sheath: Polyethylene (FU-39: glass) Heat-resistant 300C type 180C type 105C type Oil proof, Chemical proof
Ambient temperature
-30 to +350C
1.
-40 to +300C
1.
-60 to +180C
1.
-40 to +105C
-30 to +70C
Material
Fibre: Plastic, Fibre: Plastic, Sheath: Sheath: Fluorocarbon Polypropylene polymer coating
1. Ambient temperature varies depending on the distance from the tip or a fibre unit. Refer to "Dimensions". The ambient temperature for the FU-87 and 88 is in dry condition.
Video Microscope
Technical Guide
FU-35FA(Z)
NEW F-4HA
Pressure Sensors
Proximity Sensors
10 11 12 13 14
65
Weight
(Approx.)
Model FU-5F
Freecut
Thrubeam
Diffuse-reflective
66
Photoelectric Sensors
19g 21g
Standard
M4 3 mm dia.
FU-7F
Freecut
160 100 45
19g 21g 3g 6g
FU-5FZ
Freecut
ToughFlex
M4 1.5 mm dia.
FU-77,77G
Freecut
1m
65 40 25
FU-59
Freecut
High-flex
M3
FU-79
Freecut
1.65 mm dia.
M4
Sleeve
Min. bend radius of sleeve: 10 mm 0.82 mm dia. 2.5 mm dia.
24g
FU-73
Freecut
Side-view
Do not bend sleeve.
5g
FU-32
Freecut
Area detection
100 120
M4
200
23g
FU-12
Freecut
75 30 190
66g
FU-84C FU-86
Heatresistant
M4
120 50
22g
Freecut
3 mm dia.
80 50 20
FU-4F
Freecut
Standard
M6 M4
FU-6F
Freecut
36 20 12
FU-66Z
Freecut
ToughFlex
M6
FU-67, 67G
Freecut
1m
M3
28 17 10
Coaxial
1.5 mm dia.
FU-35FA
Freecut
High-flex
1.65 mm dia.
12 8
M3 4 mm dia.
Sleeve
Do not bend sleeve. 1.65 mm dia. M4 Min. bend radius of sleeve: 10 mm 1.65 mm dia.
24 15 4
10g 10g
FU-63
Freecut
FU-63T
Freecut
M4
50 30
23g
80
FU-83C
Heatresistant
M4
18
50 20
FU-85 21g
When using the FS-T1G
Freecut
When using the FS-M1H (TURBO mode) When using the FS-M1H (FINE mode) 1.Detecting range varies depending on detecting distance and target diameter. Refer to "Characteristics". Detecting distance for reflective sensors were obtained using a white paper target (standard target).
FS01
1 2 3 4 5 6 7 8 9
Type Model Fibre unit FS-M1H (FINE) Detecting distance (mm) FS-M1H (TURBO) FS-T1G
Ultra-long-detecting distance F-4 FU-7F, 86 1300 2100 600 FU-77, 77G 1000 1600 500 8 10 8
F-2HA
F-3HA
1. To use the F-1 with the FU-84C or FU-86, specify the heat-resistant F-1 when ordering.
Specifications
0-line system
Simple wiring connector unit
Model Power supply Current consumption Expandable inputs Number of outputs Response time Control output NPN FS-R0 12 to 24 VDC 5%, max. 1. 20 mA or less, plus current consumed by expansion units connected 16 (15 when using stability output) 16 410 s to 1.2 ms 2. NPN 50 mA max. (40 V max.) Residual voltage: 1 V max.
Model Power supply Current consumption Expandable inputs Input signal Response time Output mode
FS-R3 12 to 24 VDC 5% max. 1. 50 mA or less, plus current consumed by connected sensor (100 mA max.) 2 NPN/PNP non-voltage input (contact, solid-state) switching 350 s to 1 ms 2. N.O./N.C. (switch-selectable)
1. Change the supply voltage to meet the requirement of the input device (PLC, etc.). 2. The response speed varies depending on the number of expansion units connected.
1. Change the supply voltage to meet the requirement of the input device (PLC, etc.). 2. The response speed varies depending on the number of expansion units connected.
0 1 2 3 4 15
OUT 8
20 cores
20 pins
3m
34 pins
OUT 7 12 to 24 VDC 0V
* Pin 18 can be switched to OUT 15 or STB. OUT 15/STB (stability output)* 12 to 24 VDC 0V
Contact KEYENCE for cables for programmable logic controllers made by other manufacturers.
10 11 12 13 14
67
FS-T1/M1/T1G/M1H
Photoelectric sensor main circuit Overcurrent protection circuit
Brown 100mA max. Load Black (Control output) Brown 100 mA max. Load (Control output) 1. 50 mA max. Orange Load Black Blue Pink 2. (External calibration)
FS-V1
Brown
Black
12 to 24 VDC
(Stability output)
12 to 24 VDC
White Blue
(Control output)
Blue
Input circuit
Input circuit
1. When the stability output is not used, cut the orange cable at the base, or connect this cable to the 0 V terminal of the power supply. 2. The FS-M1/M1H does not have a pink cable (for external calibration).
FS-V12
Photoelectric sensor main circuit
Overcurrent protection circuit 100mA max. Load Black (Control output)
FS-T2/M2
Photoelectric sensor main circuit
Overcurrent protection circuit
FS-R0
Photoelectric sensor main circuit
Brown (common to pins 9 and 19) OUT 0 to 151. Load (Control output) 50mA max. Blue (common to pins 10 and 20)
5 to 40 VDC
5 to 40 VDC
12 to 24 VDC
0V
0V
PNP FS-V11P
Photoelectric sensor main circuit
Overcurrent protection circuit
Brown 100mA max. Load Black (Control output) Blue 12 to 24 VDC
FS-T1P/M1P
Brown
FS-V1P
Brown
100 mA max.
Black
(Control output) (Stability output)
Load
50 mA max.
12 to 24 VDC
100 mA max.
Load Load
12 to 24 VDC
Input circuit
2.
Input circuit
1. When the stability output is not used, cut the orange cable at the base, or connect this cable to the positive terminal of the power supply. 2. The FS-M1P does not have a pink cable.
FS- V12P
Photoelectric sensor main circuit
12 to 24 VDC Overcurrent protection circuit
FS-T2P/M2P
Photoelectric sensor main circuit
12 to 24 VDC Overcurrent protection circuit
0V
0V
Input circuit
NPN FS-T1/T1G/V1
External calibration input circuit
12 to 24 VDC
PNP FS-T1P/V1P
External calibration input circuit
11 k Pink Contact or solid-state input 12 to 24 VDC
NPN/PNP FS-R3
3.3 k
3.3 k
11 k
0V 2.7 k IN
When the external calibration input is not used, cut the pink cable at the root, or connect this cable to the positive terminal of the power supply.
When the external calibration input is not used, cut the pink cable at the root, or connect this cable to the 0 V terminal of the power supply.
68
FS01
Adjustment
FS-V10 Series Selecting displayed data
The display changes every time the MODE button is pressed.
Received light intensity MODE Press this button once. Display changes alternately. MODE Press this button once. Display changes alternately.
Select the sensitivity setting procedure according to the target condition. When the setting is completed, the setting value flashes twice. For sensitivity adjustment using a moving target Fully-automatic calibration
1. Pass a target through the optical axis while pressing the SET button. 2. The calibration indicator (orange LED) flashes. 3. Release the SET button. (The orange LED goes off.)
*The setting value is adjusted to the midpoint of the difference between the maximum and minimum values of the received light intensity.
1 2 3 4 5 6 7 8 9
Setting value*
Time
Displaying the setting value Press or once while the received light intensity is displayed. The setting value flashes for 2 seconds, and then the received light intensity appears once more. [Note] To change the setting value, press the setting value is flashing. or while
With no target
With target
2. The calibration indicator (orange LED) flashes. 3. Release the SET button. (The orange LED goes off.)
[Note] The MAX and MIN values vary depending on the fibre unit connected. Displaying excess gain Received light intensity is converted by defining the setting value as 100 P (%). Stable LIGHT status is obtained with 110 P (%) or more. Stable DARK status is obtained with 90 P (%) or less. Displaying the hold value The peak value or the minimum value of the received light intensity or excess gain is displayed. The setting of the output selector switch determines whether the peak value or the minimum value is displayed.
Output selector switch LIGHT-ON DARK-ON Display Hold value Peak-hold value Bottom-hold value
1. With no target in place, press the SET button and release it. (The orange LED lights.) 2. Position a target in place. Press the SET button again and release it. (The orange LED goes off.)
*The setting value is adjusted to the midpoint of the difference in the received light intensity when the target is absent and present.
SET
1. With no target, press the SET button and release it. (The orange LED lights.) 2. Place a target in the position where it is to be stopped.
3. Press the SET button for 3 seconds or more until the The setting value is adjusted to calibration indicator (orange turn on the sensor when the LED) flashes. Release the SET target comes to the place where it button. (The orange LED goes should be stopped. off.)
Displaying received light intensity Received light intensity is displayed 4095 max.
When the reflective type is used to detect a target with some objects in the background, the sensitivity is set to the maximum value at which the background objects are not detected.
1. Under the conditions on the left, press the SET button for 3 seconds or more.
If the fully-automatic calibration does not work properly, try the two-point calibration.
Pressure Sensors
SET
Proximity Sensors
Max.
10 11 12 13 14
69
FS-V1/FS-T Series
Select the sensitivity setting procedure according to the target condition. (FS-T has no display.)
UP DOWN
button.
FINE
SUPER
TURBO
SET
40ms
10ms
OFF
FINE
SUPER
TURBO
SET
40ms
MODE
10ms
OFF
FINE
SUPER
TURBO
SET
40ms
10ms
OFF
SUPER
TURBO
40ms
10ms
SET
10 ms
SUPER TURBO 40ms 10ms SET FINE OFF
FINE
OFF
SUPER
TURBO
40ms
10ms
SET
[Note] Be sure to readjust the sensitivity after the power mode is changed. Bar graph LED monitor in normal operation The LEDs show the The light is steadily +15% or more received. +10% or more received light intensity The light is irregularly with respect to the +5% or more received. Setting value setting value. -5% or less The light is irregularly The monitor shows interrupted. -10% or less the stability level of the -15% or less The light is steadily current detection. interrupted.
FINE
OFF
70
Photoelectric Sensors
or
At least 3 seconds
When the sensitivity difference is insufficient If the sensitivity has no allowance, - - - - flashes immediately after the completion of the automatic calibration. [Note] Sensitivity is set and entered even when the sensitivity difference is insufficient. Be sure to confirm that the detection is properly performed.
MODE A B CH
A 120P
SET
Power selection One lamp in the bar graph LED monitor flashes to show the currently selected power mode. Press or to choose the desired power mode.
FINE When detecting a minute difference in a short detecting distance When the detecting distance of FINE mode is insufficient When the environment is hostile, such as dusty
At least 3 seconds
MODE A B CH
A 100P
SET
TURBO
SUPER
MODE
Timer selection One lamp in the bar graph LED monitor flashes to show the currently selected output timer mode. Press or to choose the desired timer mode.
OFF Output timer OFF
OFF-delay for 10 ms
40 ms
OFF-delay for 40 ms
When the detection becomes unstable due to the change in surrounding environment or targets, readjust sensitivity.
With no target
With target
At least 3 seconds
MODE A B CH
A 120P
SET
FS01
1 2 3 4 5 6 7 8 9
PNP
Lock Brown +V
Blue
When the external calibration function is used, the stability output remains on for another 3 seconds after the calibration input is turned off. [Note] Sensitivity is set and registered even when the sensitivity difference is insufficient. Be sure to confirm that detection is properly performed.
FS-M Series
LIGHT-ON mode (When DARK-ON mode is specified, refer to symbols and words in parentheses.)
1. With no target, turn the trimmer clockwise until the red LED indicator lights (turns off). Point A
1. With a target in place, turn the trimmer clockwise until the red LED indicator turns off (lights). Point A
2. With a target in place, turn the trimmer counterclockwise until the green LED turns off (lights). Point B
A
2. With no target, turn the trimmer counterclockwise until the green LED lights (turns off). Point B
A
Optimal B position
3. Set the trimmer midway between points A and B. Confirm sensor operation.
Optimal B position
3. Set the trimmer midway between points A and B. Confirm sensor operation.
When the TURBO mode is selected with the FS-M Series, up to 8 sensors enable stable detection without mutual interference.
Video Microscope
When several units are connected, the FS01 Series alternates the light emission timing with up to four sensors so that the adjacent sensors light beams do not affect detection.
Technical Guide
DARK-ON mode (When LIGHT-ON mode is specified, refer to symbols and words in parentheses.)
Pressure Sensors
Proximity Sensors
0V
Blue
0V
10 11 12 13 14
71
Photoelectric Sensors
Stability output
[Note] When several units are connected, the stability outputs of all the units are output from the main unit based on OR logic.
Characteristics
Receiver excess gain vs. detecting distance (Typical)
FS-V/T+FU-5F, 7F ,73, 86
x 100 100 100
1000
1000
FS-V/T+FU-7F, 86+F-1
x
1000
Excess gain
10 SUPER 1 Operating level TURBO FINE 0.1 0 100 200 300 400 500 600 700 800 900 Detecting distance X (mm)
Excess gain
Excess gain
10
10 SUPER 1 Operating level FINE TURBO 0.1 0 2000 3000 4000 5000 Detecting distance X (mm) *Data was obtained using a 5-m type fiber unit. 1000
SUPER TURBO
0.1
200 400 600 800 1000 1200 1400 1600 Detecting distance X (mm)
1000
FS-V/T+FU-59, 79
x
1000
FS-V/T+FU-5FZ, 77
x
1000
FS-V/T+FU-75F
x
100
Excess gain
100
Excess gain
100
Excess gain
10 SUPER
10
SUPER
TURBO 0.1
TURBO 0.1 0 100 200 300 400 500 600 700 Detecting distance X (mm) 0 50 100 150 200 250 Detecting distance X (mm)
1000
1000
FS-V/T+FU-49X, 69X
x
1000
FS-V/T+FU-38
X
100
Excess gain
100
Excess gain
100 White mat paper 10 SUPER 1 Operating level FINE TURBO 0.1
10
10
SUPER
SUPER TURBO
72
FS01
100 80 60
Distance Y (mm)
20 15 10 5 0 5 10
15 10 5 0 5 10 15
1 2 3 4 5 6 7 8 9
10
15 20 25
30 35
40 45
10
15
20
25
Distance X (mm)
Distance X (mm)
250 200
Y Dia.
1 0 1 2 2
50 0 50 100 150 100 200 300 400 500 600 700 800
Distance Y (mm)
100
12
600
800
1000
3 4 Distance X (mm)
250
Direction B
Hysteresis (Typical)
FS-V (SUPER)+FU-7F, 86+F-2
X Y
Distance Y (mm)
100 80 60
FS-V (SUPER)+FU-59, 79
X Y
Distance Y (mm)
30 25
FS-V+FU-7F, 86+F-1
Detecting distance ON Hysteresis OFF
200 100 0 100 200 300 400 500 Distance X (mm) 1000 2000 3000 4000
10 11 12 13 14
100
1000
100
100
Excess gain
Excess gain
Excess gain
100
10
10
10
1 0
Operating level 100 200 300 400 500 600 700 800 Detecting distance X (mm)
1 0
Operating level 200 400 600 800 1000 1200 Detecting distance X (mm)
1 0
Operating level 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Detecting distance X (mm)
73
1000
Photoelectric Sensors
100
100
Excess gain
Excess gain
10
Excess gain
100
10
10
1 0
Operating level 50 100 150 200 250 300 Detecting distance X (mm)
1 0
Operating level 50 100 150 200 250 300 Detecting distance X (mm)
1 0
120 90
12 8
400
Distance Y (mm)
Distance Y (mm)
30 0 30 60 90
Target: 100 x 100 white mat paper 25 50 75 100 125 150 175 Distance X (mm)
Distance Y (mm)
60
200 100 0 100 200 300 500 1000 1500 2000 2500 3000 3500 Distance X (mm)
120
12
400
Hysteresis (Typical)
80 60
Distance Y (mm)
4
Hysteresis (mm) Hysteresis (mm)
20
40
60
80
100
50
100
150
200
Distance X (mm)
Distance X (mm)
100
200 175
Distance Y (mm)
Distance Y (mm)
8 6
0.8 (without slit) 0.5 (when using slit A) 0.5 (without slit) 0.3 (when using slit B) Detecting area
4 2
Diameter
40
Distance X (mm)
74
FS01
1 2
1. Insert the fibre unit into the corresponding cutter hole to the desired length. 2. Cut the fibre by quickly pushing the blade all the way down. Stopping the blade midway will prevent a clean cut, thereby lessening the detecting distance. Do not use a cutter hole more than once.
1
1 2 3 4 5 6 7 8 9
To connect a fibre unit with a small diameter, use the adapter included with the FU Series. 1. Attach the adapter to the fibre unit. 2. Fully insert the adapter into the mounting holes of the amplifier, and then lift the quick-release lever.
The required adapter is included in each model of the FU Series. If an inadequate adapter is used, the fibre unit cannot be properly installed.
Type Adaptor A (OP-26500)
For 1.3 mm diameter
Shape
Adaptor B (OP-26501)
For 1 mm diameter
FU-16/18/31/37/38/38V/48/59/ 68/75F/79/95
To connect the coaxial reflective type fibre unit to the amplifier, connect the single-core fibre to the transmitter side, and connect the multiple-core fibre to the receiver side. (Connect the fibres according to the marking on the amplifier lateral side.)
Single-core Transmitter Receiver Multiple-core
Pressure Sensors
Proximity Sensors
10 11 12 13 14
75
Amplifier
When extending, use the cable whose sectional area is more than 0.3 mm3. Do not extend the cable more than 100 m. (When using the expansion unit, contact Keyence.)
Photoelectric Sensors
If the amplifier cable is placed together with power lines or high-voltage lines in the same conduit, detection error may occur due to noise interference, or the sensor may be damaged. Isolate the amplifier cable from these lines. Do not use the FS01 Series outdoors, or in a place where extraneous light can enter the light-receiving surface directly. When the external calibration input is not used, cut the pink cable at the base, or connect this cable to the 0 V terminal of the power supply. If the wiring is incorrect, the unit may heat up, or the sensitivity setting may fluctuate. Do not remove the protective cover of the expansion connector on the outermost unit.
Protective cover
1. The FS-V11/V1/T1/M1, PS-T1, CZ-K1 (1-line connection) and FS-R0 (0-line connection) can be used as the main unit. 2. The FS-V12/T2/M2, PS-T2 (1-line connection) and FS-T0/M0 (0-line connection) can be used as the expansion unit. (The FS-T Series and FS-M Series can be used together.)
[Notes] When several units are connected, confirm the ambient temperature. (See Specifications.) To connect several units, be sure to use a DIN rail and end units. When detaching amplifiers from DIN rail, slide the expansion units apart, and detach them individually.
Do not detach several units at one time that are connected together.
76
FS01
Dimensions
Thrubeam type
FU-5F/5FZ
Free-cut
Unit: mm
FU-32
2.3
2.2
1.3
0.6
Photoelectric Sensors
1920
*Area for mounting 1 1000
1 2 3 4 5 6 7 8 9
15 (14)
15
15
1000
FU-7F
Free-cut
FU-34
M2.6 x P0.45 Across-flats: 7, t=2 M4 x P0.7 Nickel-plated brass 2.2
Free-cut
2.5
0.4
10
Bendable area 65
5 15
12
2000
65
15
FU-59
Free-cut
3.9
2000
FU-16
Free-cut
3.6
4 Stainless steel
10
1
1000
Bar Code Readers Video Microscope Analog Sensor Controllers Technical Guide Thrubeam Measuring Displacement Sensors Instruments
FU-73
Free-cut
1.3
17
13
2000
10
Bendable area
Vision Systems
12 20 23.3
1.0
FU-18
Free-cut
3.6
4 Stainless steel
2
1
65
15
2000
FU-75F
Across-flat: 5.4, t=2 M3 x P0.5 Nickel-plated brass 1.0 * Do not bend this area.
17
13
2000
15 *
15
1000
Pressure Sensors
Proximity Sensors
10 11 12 13 14
77
FU-77
Free-cut
FU-88
Across-flats: 7, t=2 M4 x P0.7 Nickel-plated brass 2.2
Free-cut
M2.6 x P0.45
Photoelectric Sensors
1
3 11 2000
15
2000 1
FU-92 FU-77G
Across-Flat : 7, t=2, M2.6 x P=0.45 M4 x P0.7 Nickel-plated brass 4
Free-cut
5.0 Teflon-tube
3.7 lens
1.13 core fibre 3 12 22
100
FU-78
Free-cut
FU-96
Across-flats: 7, t=2
Free-cut
5.0 Teflon-tube
M4 x P0.7 Nickel-plated brass 1.3 (4.5) Centre of optical axis
M2.6 x P0.45
2.8 lens
8 x 0.265 core fibre 3 12 2000
2000
100
FU-79
Free-cut
Diffuse-reflective type
1.0
FU-4F/4FZ
4 x 0.265 core fibre
core fibre
Free-cut
2 x 1.0 (1.13)
3 stainless steel
2 x 1.3
10
1000
17
FU-84C
Free-cut
FU-6F
M4 x P0.7 stainless steel 4.2 Hexagonal clasp
Free-cut
Across-flats: 10, t=2 2 x 1.0 core fibre M6 x P0.75 Nickel-plated brass 2 x 2.2
M2.6 x P0.45
1.0 fibre
Across-flats: 7, t=2
4 3
14
2000
12
10
FU-21X
480 20 (-40 to 200C) (-40 to 70C) 0.25 core fibre Across-flats: 5.4, t=2 M3 x P0.5 Nickel-plated brass 1.5
FU-86
Free-cut
M2.6 x P0.45
15
500
FU-21X+F-2HA
15.6
3 12 2000
12
78
FS01
FU-22X
0.5 core fibre 1.77 stainless steel
FU-48
Free-cut
Unit: mm
3 stainless steel 2 x 1.0
14
500
15 2000
FU-23X
1.0 core fibre
3 stainless steel
2.2
FU-49X
4 x 0.265 core fibre 1.5 stainless steel 1.0
1 2 3 4 5 6 7 8 9
17
500
15 1000
FU-25
Free-cut
Across-flats: 10, t=2 1.0 core fibre 4 16 x 0.25 core fibre 3 M6 x P0.75 Nickel-plated brass 2 x 2.2
FU-31
Free-cut
10
15
15
2000
FU-63/63Z
Free-cut
FU-33
2.1
Free-cut
10 2 x0.5(0.65)
1.3(1.65) 2
65
15
( ) shows FU-63Z.
FU-35FA/35FZ
Free-cut
FU-65X
2 x 0.265 core fibre 0.82 stainless steel Across-flats: 5.4, t=2 M3 x P0.5 Nickel-plated brass
FU-35FA(35FZ)+F-2HA FU-66/66Z
15.6 15 (9) 5 ( ) shows FU-35FZ.
Free-cut
Across-flats: 7, t=2 2 x 1.0 ( 1.13) core fibre M4 x P0.7 stainless steel 2 x 1.3
FU-35FA(35FZ)+F-3HA
9.5
15 (9)
5 ( ) shows FU-35FZ.
2.6 3
12
FU-43
Free-cut
FU-67
1.65 stainless steel 4 stainless steel 2 x 1.3
Free-cut
15
2000
13
2000
FU-45X
2 x 0.265 core fibre
FU-67G
0.82 stainless steel 3 stainless steel 1.0
Across-flats : 10, t=2, 2 x 1.13 core fibre 4 2 15 1000 M6 x P0.75 Nickel-plated brass 3.8 Stainless steel
500
Video Microscope
1.3 2
Technical Guide
Vision Systems
2.3
2.5
core fibre
Pressure Sensors
1.3
Proximity Sensors
FU-63T
Free-cut
10 11 12 13 14
79
FU-68
Free-cut
Definite-reflective type
Across-flats: 7, t=2 M4 x P0.7 stainless steel 2 x 1.0
FU-37
Free-cut
Photoelectric Sensors
3 3 12 2000
3 8.4 14.4
FU-69X
Across-flats: 5.4, t=2 4x 0.265 core fibre 10 M3 x P0.5 Nickel-plated brass 1
2 x 1 7 19
2000
FU-38
1000
Free-cut
2 x 1
FU-81C
1.45 fibre Across-flats: 7, t=2 1.85 2.1 stainless steel Bendable area 90 1000 500 (-30 to 350C) M4 x P0.7 stainless steel 5 3.8
4 6
5.5
7 19
3.5 2000
5 15
FU-38R
5 25 15 3.8 20 480 (-30 to 200C)(-30 to 70C)
Free-cut
FU-82C
Across-flats: 7, t=2 Hexagonal clasp 1.45 fibre 2.1 Stainless steel Bendable area 90 1000 500 (-40 to 300C) 480 20 (-40 to 300C) (-40 to 70C) 5 25 10 M4 x P0.7 stainless steel 4.2 Hexagonal clasp 3.4 stainless steel 3.8 3 14.9 29 6.5 (4.6) (20)* *Do not bend this part. 2000
20
FU-38V
Free-cut
2 x 3.2, 6.2 spot facing mounting hole 12 4.3 5.5 7 19 3.5 2000
2 x 1
FU-83C
Across-flats: 7, t=2 1.45 fibre 2.6 3 3.4 stainless steel 14 10 1000 500 480 20 (-40 to 300C) (-40 to 200C) (-40 to 70C) M4 x P=0.7 stainless steel 4.2 Hexagonal clasp
Liquid-level type
FU-93
Free-cut
FU-85
6, Teflon tube
2 x 1.3
Free-cut
2000
FU-94C
2 x 2.2
FU-87
Free-cut
(80)*
2000
10 200
FU-91
Free-cut
FU-95
4.5 Teflon -tube
4.2 Teflon -tube 2 x 1.3
Free-cut
15 5
2000 *Embed this area in metal casing. *Do not bend or cut this portion.
100
1 x 2 11 20
2000
80
FS01
Amplifier
FS-V11(P)
3.9, 3-core (Brown/Blue/Black) x 0.34 mm Cable length: 2 m 9 (Maximum when the cover is opened) 90 3 0.7 (33) 28.5 4 (13) 6.7 20.7 66 35.4 12 min.
2
1 2 3 4 5 6 7 8 9
DIN-rail mounting
36.5 3.8 8 22.8 25.6 30.8 25.4 12 min. 2 x 3.4, spot facing: 6, d=2.7 16
FS-V10/V12(P)
9 (Maximum when the cover is opened) 90 4 3 0.7 (33) 28.5
DIN-rail mounting
FS-V1(P)
3.9, 5-core 18 (Maximum when the cover is opened) 78
*3.9 5-core
( Black/Orange/Pink: 0.18 mm (
2
Cable length: 2 m
DIN-rail mounting
1.1 6
DIN-rail mounting
1.1 6
4 6.7
(33)
28.5
(12.5) 6.7
Bar Code Readers Video Microscope Analog Sensor Controllers
8.4 35.4 53.5 3.6
8.4
35.4 53.5
12 min.
FS-T2(P)/M2(P)
FS-T2/M2 (1-line expansion unit) 9
FS-T0/M0
FS-T0/M0 (0-line expansion unit) 9
DIN-rail mounting
1.1 6
DIN-rail mounting
1.1 6
(33)
28.5
Technical Guide
Vision Systems
135 max.
Cable length: 2 m
Pressure Sensors
Proximity Sensors
10 11 12 13 14
81
FS-R0
5.8 2-core x 0.5 mm2 Cable length: 2 m
FS-R3
Photoelectric Sensors
6 (22.6) 20.8 9.2
6.9 24
Cable diameter
DIN-rail mounting
135 max.
DIN-rail mounting
34.6
8.4
8.4 14 min. 35.4 53.5
35.4 53.5
End unit 2.
DIN-rail mounting
35.4 53.8
1. The FS-V11/V1/T1/M1/R0, PS-T1, CZ-K1 is mounted in . 2. When using expansion units, be sure to use the end unit (accessory to the FS-R0, T2, M2).
No. of units 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Attachment (optional)
F-1
2.8 4 6 9.5
F-2HA
4.3 5 15.6 5
F-2
4 7.9
F-3HA
4.3 5 9.5 5
OP-6631
5.8 spiral tube M4, P0.7 (for mounting the fibre unit) 7, d=10 (for mounting the connector)
F-4
4.3 9.5
F-4HA
8 15
7.4 8 27 8
8 12 1000 13 10
82
MEMO
High Accuracy Fibreoptic Sensors
FS01
Technical Guide
Video Microscope
83
Vision Systems
Pressure Sensors
Proximity Sensors
Photoelectric Sensors
6 7
10
11
13
12
14