A1 B1 Check Valve

Pilot to open
Sandwich plate type
A B ZWI-RP06
Pmax = 350 bar
Qmax = 60 l/min

ZWI-RP06 is check valves available indirect or pilot operated models.


Valves are designed to operate in hydraulic systems with hydraulic mineral oil or synthetic fluid having similar lubricating
characteristics.
1. MAIN CHARACTERISTICS, SEALS AND HYDRAULIC FLUIDS
Assembly position / location Any position
Sub plate surface finishing Roughness index Ra 0.4 - flatness ratio 0.01/100 (ISO 1101)
MTTFd values according to
150 years
EN ISO 13849
Standard execution /FKM= -20°C to +70°C
/NBR = -30°C to +70°C
Ambient temperature
/HNBR= -40°C to +70°C
NBR seals (standard) = -20°C to +60°C, with HFC hydraulic fluids = -20°C to +50°C
Seals, recommended fluid FKM seals = -20°C to +80°C
temperature HNBR seals = -40°C to +60°C, with HFC hydraulic fluids = -40°C to +50°C.
Recommended viscosity 15 to100 mm²/s - max allowed range 2.8 to 500 mm2/s

ISO 4406 class 21/19/16 NAS 1638 class 10, achievable with in line filters - 25 µm
Fluid contamination class
(β10≥75 recommended)

Hydraulic fluid Suitable seals type Classification Ref. Standard


NBR, FKM, HL, HLP, HLPD,
Mineral oils DIN 51524
HNBR HVLP, HVLPD
Flame resistant without water FKM HFDU, HFDR
ISO 12922
Flame resistant with water NBR, HNBR HFC

2. VALVE CONFIGURATION

ZWI-RP06-AAB ZWI-RP06-A ZWI-RP06-B

The pilot pressure applied through ports A or B opens the valve acting on ports B and A, respectively.
Doc. No. 4373915/0 07/18

The minimum pilot pressure is a function of the area ratio; Area Ratio=3.3:1.

1 of 2
3. MODEL CODE
Standard Models Part Numbers ZWI-RP06 -AAB- -2 - -50- V
ZWI-RP06-AAB-0.5-50-V 4370214
ZWI-RP06-AA-0.5-50-V 4369832
ZWI-RP06-AB-0.5-50-V 4370226 Name and Nominal Size
RP06- Pilot to Open Check Valve.

Other Types on Request Types Pilot Operated


B: Check in Line & B.
: Check in Line
B: Check in Line B

Cracking Pressure
- 0.5 bar, 4 4 Bar.
2 2 bar, 8 8 Bar.

Series Number

Seals Material
N NBR
V FKM
HNBR-HNBR

4. PERFORMANCE
Measured on Mineral Oil ISO VG46 at 50°C
1 ->A1; B->B1; 2 = A1->A; B1->B

5. INSTALLATION DIMENSIONS [mm]


Check valve in Line A & B, Check Valve in Line A, and Check Valve in Line B.

1. O-Ring 9.25 x 1.78 (4 pcs.)


2. Fastening bolts: 4 socket head
screws M5. The length depends
on number and type of modular
elements associated.
3. Fixing elements are not in scope of
delivery.
Doc. No. 4373915/0 07/18

HYDAC INDIA PVT.LTD.


NOTE: The information in this brochure HYDAC HOUSE,
Relates to the operating conditions and Plot No. A-58, T.T.C., Ind. Area,
Applications described. For applications or M.I.D.C., Mahape,
Operating conditions not described, please Navi Mumbai – 400710
Contact the relevant technical department. Tel: +91 22 – 41118888
Email: info@hydacindia.com 2 of 2
Subject to technical modification. www.hydacindia.com