001 Feled Eng 2023

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 15

ATX™ FELED Series Nonmetallic LED Luminaires

Standard and Emergency Battery Back-Up, Increased Safety

ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10

LED/AREA: ATEX/IECEX ENCLOSED AND GASKETED/INCREASED SAFETY


Applications
• For use in locations where:
— Hazardous areas are designated as Zone 1 and 2 – 21 and 22
— A high degree of corrosion resistance is required
— Protection against dirt, water and moisture is necessary
• Typical applications include:
— Oil refineries
— Petrochemical facilities
— Food processing plants
— Waste and water treatment plants
— Underground tunnels
— General manufacturing facilities
Features
• Available in 5000K or 4000K Color Temperatures.
• Meets photobiological requirement for Risk Group 0 (RG0).
• Easy to retrofit in same mounting footprint as Appleton’s FE Standard Materials
series nonmetallic fluorescent luminaires. • Housing: fiberglass reinforced polyester
• Full range of lumen outputs, with light distribution equivalent to • Lens: polycarbonate
Appleton’s FE series fluorescent luminaires. • Diffuser: polycarbonate
• Corrosion-resistant fiberglass reinforced polyester body and • Gasket: elastomer
hinged polycarbonate lens. • Internal reflector: highly reflective white polycarbonate (standard
• High impact resistance housing (20 Joules – IK10) from versions) or powder coated aluminum (emergency versions)
-30 °C to +55 °C (-22 °F to +131 °F) ambient temperature • Mounting accessories available in different materials such as
and wind profile for use in extreme offshore and onshore gray painted aluminum, zinc plated steel, galvanized steel or
environments. 316 stainless steel
• 60,000+ hour LED life for years of maintenance free operation.
• Lightweight design, hinged cover with captive screws, and ATEX/IECEx Certifications and Compliances
terminal block wiring for easy installation and maintenance. • Certification Type: FELED30
• Contemporary, low profile design suitable for tight spaces. — Gas: Zones 1 and 2
• Standard screw-type terminal block can accept 1.5 to 6 mm2 – Conforming to ATEX 2014/34/EU: II 2 G
wire. – Type of Protection: Ex eb mb op is IIC Gb
• Field replaceable LED driver. – Temperature Class: T4
• Industry-leading thermal management for safe, reliable — Dust: Zones 21 and 22
operation over wide temperature range. – Conforming to ATEX 2014/34/EU: II 2 D
• Universal, high efficiency, drivers cover voltage requirements for – Type of Protection: Ex op is tb IIIC Db
120-277 Vac, 170‑300 Vdc, 50/60 Hz +/- 10%. – Surface Temperature: +60 °C to +75 °C (+140 °F to +167 °F)
• High power factor electronic driver (>0.95). • Ambient Temperature: -30 °C up to +55 °C
• Standard 6KV surge suppression. (-22 °F up to +131 °F)
• M20 plug or M25 plug provided. • EU Declaration of Conformity: 50318
• Latch assembly and elastomer gasket seals against water and • ATEX Certificate: INERIS 18 ATEX 0042X
dust ingress, IP66. • IECEx Certificate: IECEx INE 18.0039X
• Easily accessed for maintenance using Allen key or straight • Certification Type: FELED (emergency)
blade screwdriver. — Gas: Zones 1 and 2
• Central opening with unique patented release system to prevent – Conforming to ATEX 2014/34/EU: II 2 G
damage. – Type of Protection: Ex db eb mb IIC Gb
• Can be horizontally or vertically mounted. – Temperature Class: T6
• Available in 3 hour emergency version, including built-in monthly — Dust: Zones 21 and 22
self- test. Test results through multi-colored LED. – Conforming to ATEX 2014/34/EU: II 2 D
• Positive safety switch disconnects power to LED’s and driver to – Type of Protection: Ex tb IIIC Db
allow maintenance in hazardous locations (emergency version). – Surface Temperature: +63 °C to +73 °C (+145 °F to +163 °F)
• Ex e battery with plug-in connector. • Ambient Temperature: -20°C up to +50 °C (-4 °F up to 122 °F)
Options • EU Declaration of Conformity: 50317
• ATEX Certificate: LCIE 16 ATEX 3048X
• 3 Hours Emergency/Battery Back-Up available ; • IECEx Certificate: IECEx LCIE 16.0038X
— Add suffix -E to the end of the catalog number. • Standard and Emergency:
Example: FELED5CBDSADE — Index of Protection according EN/IEC 60529: IP66
— Impact Resistance (shock): IK10
— Photobiological Safety, IEC 62778 and IEC 62471: RG0 at
0.25m mounting height

 Available for 5K lumen models only.

Visit our website at www.emerson.com or contact us at (800) 621-1506. 1


© May 2019
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety
LED/AREA: NEC/CEC EXPLOSIONPROOF/ATEX/IECEx FLAMEPROOF/INCREASED SAFETY

ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10

Order using catalog numbering guide below or select catalog number from tables on following pages.

FELED 3 C BU S A D

Series: Lumen Voltage: Cable Entry:


FELED - Zone 1, 2, Output : BU - 120-277Vac, A - Armored
21, 22 ATEX/ 3 - 3K 170-300Vdc, M20 
IECEx 4 - 4K 50/60 Hz N - Unarmored
Certified 5 - 5K BD - 100 to 240 Vac, M25 
7 - 7K 50/60 Hz 

LED Position: Color Temperature: Mounting Version : Options:


Blank - Direct (with diffuser) C - 5000K (Cool) S - Surface/Suspension Mount D - Diffused 
I - Indirect (without diffuser) N - 4000K (Neutral) Standard Wiring (single E - 3H Emergency
phase) (combined) 
L - Surface/Suspension Mount
Dual Loop In/Out Through
Wiring (single phase)

 All values displayed reflect typical values.


 Standard and Loop In/Out cable entries provide 3 entries; 1 at one and 2 at the other end of the housing.
 BD voltage for emergency model only
 Must order armored cable glands separately. M20 entries are with brass earth continuity plate for armored cable.
 Cable glands provided in luminaires with unarmored hub entries.
 Diffuser required for direct, not included with indirect.
 Available for 5K lumen model only.

2 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2019
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety

ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10

LED/AREA: ATEX/IECEX ENCLOSED AND GASKETED/INCREASED SAFETY


Lumen Comparison Chart
Correlated
Color Color
Line Current Input Power Lumen Output Efficacy Temperature Rendering
Amps Power Factor (Lumens) (lm/w) (CCT) Index (CRI) Length Weight Catalog Number

3,058 99 FELED3CBUxxD
5000K 70+
1,886 61 FELEDI3CBUxx
0.140A at
31 > 0.96
230Vac
2,512 81 FELED3NBUxxD
4000K 80+
1,616 52 FELEDI3NBUxx
0.785 m 4.5 kg
(2.58 ft) ( 9.9 lbs)
4,196 95 FELED4CBUxxD
5000K 70+
2,617 59 FELEDI4CBUxx
0.195A at
44 > 0.96
230Vac
3,428 78 FELED4NBUxxD
4000K 80+
2,111 48 FELEDI4NBUxx

5,290 106 FELED5CBUxxD


5000K 70+
3,260 65 FELEDI5CBUxx
0.224A at
50 >0.98
230Vac
4,380 88 FELED5NBUxxD
4000K 80+
2,613 52 FELEDI5NBUxx
1.39 m 8.5 kg
(4.56 ft) ( 18.74 lbs)
7,181 96 FELED7CBUxxD
5000K 70+
4,200 56 FELEDI7CBUxx
0.333A at
75 >0.97
230Vac
5,879 78 FELED7NBUxxD
4000K 80+
3,458 46 FELEDI7NBUxx

Visit our website at www.emerson.com or contact us at (800) 621-1506. 3


© May 2019
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety

ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10
LED/AREA: ATEX/IECEX ENCLOSED AND GASKETED/INCREASED SAFETY

Technical
Data
Gas Dust
T Rating Surface T°
Position
Horizontal / Ta = +40°C Ta = +50°C Ta = +55°C Ta = +40°C Ta = +50°C Ta = +55°C
Model Type Vertical (+104°F) (+122°F) (+131°F) (+104°F) (+122°F) (+131°F)

FELED3 Direct/ 60°C 70°C 75°C


T4 T4 T4
Indirect

 (140°F) (158°F) (167°F)

FELED4 Direct/ 60°C 70°C 75°C


T4 T4 T4
Indirect

 (140°F) (158°F) (167°F)

FELED5 Direct/ 60°C 70°C 75°C


T4 T4 T4
Indirect

 (140°F) (158°F) (167°F)

FELED5 63°C 73°C


T6 T6 -- --
Emergency

 (145°F) (163°F)

FELED7 Direct/ 60°C 70°C 75°C


T4 T4 T4
Indirect

 (140°F) (158°F) (167°F)

“T” Numbers Represent the Maximum Temperature


“T” # T1 T2 T3 T4 T5 T6

301-450 201-300 136-200 101-135 86-100 85


Temp.
Range
ºC (˚ºF) (547-842) (394-572) (277-392) (214-275) (187-212) (185)

4 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2019
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety

ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10

LED/AREA: ATEX/IECEX ENCLOSED AND GASKETED/INCREASED SAFETY


Wiring Diagrams

Standard

Version
Version
:L :L Version
Version
:S:S

DualDual
LoopLoop
In/Out
In/Out
- Through
- Through
Wiring
Wiring
(Single
(Single
Phase)
Phase) Standard
Standard
(Single
(Single
Phase)
Phase)

3 entries,
3 entries,
1 at1one
at one
endend
andand
2 at2the
at the
other
other 3 entries,
3 entries,
1 at1one
at one
endend
andand
2 at2the
at the
other
other
PE
PE

PE
PE

PE
PE
N
LN
N
N
N
N

PE
PE

PE
PE
L
LL
L
L

N
N
N
N
LL
L
L
Emergency

Version : L Version : L Version : S Version : S

Dual Loop In/Out - Through


Dual Loop
WiringIn/Out
(Single
- Through
Phase) Wiring (Single Phase) Standard (Single Phase)
Standard (Single Phase)

3 entries, 1 at one end 3and


entries,
2 at the
1 atother
one end and 2 at the other 3 entries, 1 at one end 3and
entries,
2 at the
1 atother
one end and 2 at th

PE

PE
PE

PE
PE

PE
PE

PE
PE

PE

L’
L’

L’
L’
N

N
N

N
L
L

L
L
L’

L’
N

LN

N
L’

L’

L’

L’
N

LN
L

L
L

Visit our website at www.emerson.com or contact us at (800) 621-1506. 5


© May 2019
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety

ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10
LED/AREA: ATEX/IECEX ENCLOSED AND GASKETED/INCREASED SAFETY

Wiring Diagram Emergency Function Diagram


Mains Mains Lighting Switch ON Lighting Switch OFF
PE N L

Lighting
Switch ON

L’

OFF
L
Standard LED
N Lighting Fixture
PE

L’
L Emergency LED
N Lighting Fixture
PE

LED Status
Color Indication Function
LED Blinking Mains voltage available – Battery charging
Green
LED Continuous Mains voltage available – Battery connected and loaded
Green and Red LED Blinking Alternately (2s) Mains voltage available – Battery in repair mode
LED Blinking Mains voltage available – No battery connected OR defective
Mains voltage NOT available — Light unit powered by batteries
LED Continuous
Red (emergency mode)
Mains voltage NOT available — Battery low (emergency mode com-
LED Flashing
pleted)
Yellow (Orange) and another Mains voltage available— Last automatic or manual operational check
LED Blinking Alternately
color has been unsuccessful
None (Off) No Light Emitted Mains voltage NOT available — Battery completely empty
Self-Test: In 3 month intervals batteries are automatically discharged and recharged once.

Emergency Light Duration


Version Battery Capacity Duration Light Output

5K 7 Ah – 6V 3 hours 25%

6 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2019
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety

ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10

LED/AREA: ATEX/IECEX ENCLOSED AND GASKETED/INCREASED SAFETY


Accessories and Replacement Parts

Description Catalog Number


Fixing Brackets
Set of two brackets for surface installation

Zinc plated steel FEFBZ

Brackets for Surface Mounting

Set of two

316 stainless steel FESBS

M8 Ring Bolts
Set of two

Zinc plated steel


FERBM8Z

Half Clamps Brackets for Pole Mounting


Set of two
Diameter for 1-1/4 to 1-1/2" pole: 42 mm (1.65 in) to 49 mm (1.93 in)
Zinc plated steel FEHC49Z
316 stainless steel FEHC49S
Diameter for 2" pole: 60 mm (2.36 in)
Zinc plated steel FEHC60Z
316 stainless steel FEHC60S
Hinged Brackets

Set of two brackets for adjusting luminaire


Aluminum FEHBA
316 stainless steel FEHBS
Fall Prevention Kit

Safety chain retains fixture temporarily to ease installation


For M25 cable entry FESCM25
For M20 cable entry FESCM20

Visit our website at www.emerson.com or contact us at (800) 621-1506. 7


© May 2019
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety

ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10
LED/AREA: ATEX/IECEX ENCLOSED AND GASKETED/INCREASED SAFETY

Accessories and Replacement Parts

Description Catalog Number


Replacement Drivers and Inverter

FELED3 Replacement Driver (1 each) APMZ050C135UD55

FELED4 Replacement Driver (1 each) APMZ050C135UD80

FELED5 Standard Model Replacement Driver (1 each) APMZ050C135UD95

FELED7 Replacement Driver (2 each) APMZ050C135UD67

FELED5 Emergency Model Replacement Driver (1 each) Z00928

FELED5 Emergency Model Inverter (1 each) Z00930

Replacement Lens

0.79 m (2.6 ft) clear polycarbonate external lens with gasket Z00650

1.39 m (4.6 ft) clear polycarbonate external lens with gasket Z00651

Battery Pack

Battery Pack 6V 7Ah for FELED5 Emergency version Z00848

8 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2019
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety

ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10

LED/AREA: ATEX/IECEX ENCLOSED AND GASKETED/INCREASED SAFETY


Mounting Options Dimensions in Millimeters (Inches)
FEFBZ: zinc plated steel — Set of two quick fixing brackets for ease of surface mounting

9.0 mm
(0.35")

64 mm
(2.52")
9.0 mm
(0.16")

30 mm
(1.18")

8.5 mm
(0.33")
8.5
25.0 mm (0.98")
49.0 mm (1.93")

FESBS: 316 stainless steel — Set of two brackets for surface mounting

232 mm (9.13")
200 mm (7.87")
38.0 mm
(1.50")
13.0 mm
(0.51")

32.0 mm
(1.26")
9.5 mm
(0.37")
9.5

14.5
14.5mm (0.57")

FERBM8Z: zinc plated steel — Set of two ring bolts

20.0 mm
(0.79")

8.0 mm
(0.31")
15.0 mm 36.0 mm
(0.59") (1.42")

M8x31.8 mm
M 8(1.25")
x 1.25

Visit our website at www.emerson.com or contact us at (800) 621-1506. 9


© May 2019
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety

ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10
LED/AREA: ATEX/IECEX ENCLOSED AND GASKETED/INCREASED SAFETY

Mounting Options Dimensions in Millimeters (Inches)


FEHC49Z: zinc plated steel or FEHC49S: 316 stainless steel — Set of two clamps for pole diameter 42 mm to 49 mm (for 1-1/4” to 1-1/2" pole).
FEHC60Z: zinc plated steel or FEHC60S: 316 stainless steel — Set of two clamps for pole diameter 60 mm (for 2” pole).

95 for 31.8 mm (1.25")


or 38.1 mm (1.50")

75.0 mm
(2.95”)

14.0 mm
(0.55”) or 84 for 50.8 mm (2.00")
31.8 mm (1.25")
or 38.1 mm (1.50")

m
m )
60 6”
85 mm Ø (2.3
(3.31”)

14.0 mm
(0.55”) 50.8 mm
(2.00")

FEHBA: aluminum or FEHBS: 316 stainless steel — Set of two hinged brackets for adjusting luminaire.
32.0 mm
5.5 mm (1.26”)
(0.22”)
82 18.0 mm
.
(3. 0 m
(3. 0 mm

23 m (0.71”)
”)
”)
03
.
77

132 mm (5.20”)
30°

100.0 mm
60
30

90

(3.94”) 14.5 mm
0

30
60
(0.57”)
90

30°

M8x31.8 mm
(1.25")
41.0 mm 13.0 mm 9.5 mm
(1.61”) (0.51”) (0.37”)

10 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2019
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety

ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10

LED/AREA: ATEX/IECEX ENCLOSED AND GASKETED/INCREASED SAFETY


Luminaire Dimensions in Millimeters (Inches)

145.0 mm
(5.71")

217.0 mm
(8.54")

End View

400.0 mm 2 X M8
(15.75")

785.0 mm (30.91")

Side View — 0.785 m (2.58 ft)

2 X M8
700.0 mm (27.56")

1390.0 mm (54.72")

Side View — 1.39 m (4.56 ft) Version

Visit our website at www.emerson.com or contact us at (800) 621-1506. 11


© May 2019
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety

ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10
LED/AREA: ATEX/IECEX ENCLOSED AND GASKETED/INCREASED SAFETY

Photometric Data — DATA SHOWN IS ABSOLUTE


5000K CCT, With Diffuser
REPORT NUMBER: FELED3CBUxxD

Luminaire Lumens: 3,057

POLAR CANDELA DISTRIBUTION ISOCANDELA PLOT ZONAL LUMEN SUMMARY

180° 170° 160° 150° 140° Zone Lumens % Lamp % Luminaire


1,100 -80° -60° -40° -20° 0° 20° 40° 60° 80° 0-30 785.8 25.7% 25.7%
80° 0-40 1,285.8 42% 42.1%
917 130°
60° 0-60 2,256.9 73.8% 73.8%
733 40° 60-90 650.7 21.3% 21.3%
120°
550 20° 70-100 385.9 12.6% 12.6%
90-120 133.2 4.4% 4.4%
110° 0°
367 0-90 2,907.6 95.1% 95.1%
-20°
183 100° 90-180 150.1 4.9% 4.9%
-40°
0-180 3,057.7 100% 100%
0.00 90° -60°
183 80° -80° LUMENS PER ZONE
367
Zone Lumens % Total Zone Lumens % Total
70° 0-10 95.8 3.1% 90-100 58.8 1.9%
Cd: 911, 90% Cd: 405, 40%
550 Cd: 759, 75% Cd: 304, 30% 10-20 274.2 9.0% 100-110 43.6 1.4%
60° Cd: 607, 60% Cd: 202, 20% 20-30 415.8 13.6% 110-120 30.8 1%
733 Cd: 506, 50% Cd: 101, 10%
30-40 500.0 16.4% 120-130 11.0 0.4%
917
Point of Max Cd: 1,013.8 40-50 519.2 17.0% 130-140 2.3 0.1%
50°
50-60 451.8 14.8% 140-150 1.4 0%
1,100 60-70 323.6 10.6% 150-160 1.1 0%
0° 10° 20° 30° 40°
70-80 209.4 6.8% 160-170 0.8 0%
-0° H -45° H 80-90 117.6 3.8% 170-180 0.3 0%
-90° H

5000K CCT, With Diffuser


REPORT NUMBER: FELED4CBUxxD

Luminaire Lumens: 4,195

POLAR CANDELA DISTRIBUTION ISOCANDELA PLOT ZONAL LUMEN SUMMARY

180° 170° 160° 150° 140° Zone Lumens % Lamp % Luminaire


1,400 -80° -60° -40° -20° 0° 20° 40° 60° 80° 0-30 1,078.1 25.7% 25.7%
1,167 130°
80° 0-40 1,763.6 42% 42%
60° 0-60 3,095.2 73.8% 73.8%
933
40° 60-90 894.2 21.3% 21.3%
120° 70-100 530.3 12.6% 12.6%
700 20°
90-120 182.8 4.4% 4.4%
110° 0°
467 0-90 3,989.4 95.1% 95.1%
-20° 90-180 206.3 4.9% 4.9%
233 100°
-40° 0-180 4,195.7 100% 100%
0.00 90°
-60°
233 80° -80° LUMENS PER ZONE
467 Zone Lumens % Total Zone Lumens % Total
70°
Cd: 1,252, 90% Cd: 556, 40% 0-10 131.5 3.1% 90-100 80.8 1.9%
700
Cd: 1,043, 75% Cd: 417, 30% 10-20 376.3 9.0% 100-110 59.7 1.4%
60° Cd: 835, 60% Cd: 278, 20%
933
Cd: 696, 50% Cd: 139, 10% 20-30 570.3 13.6% 110-120 42.3 1%
30-40 685.5 16.3% 120-130 15.3 0.4%
Point of Max Cd: 1,392.2
1,167 50° 40-50 712.1 17.0% 130-140 3.3 0.1%
1,400
50-60 619.5 14.8% 140-150 2.0 0%
0° 10° 20° 30° 40° 60-70 444.6 10.6% 150-160 1.5 0%
Max CD -45° H 70-80 288.2 6.9% 160-170 1.1 0%
80-90 161.4 3.8% 170-180 0.4 0%
-0° H
-90° H

12 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2019
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety

ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10

LED/AREA: ATEX/IECEX ENCLOSED AND GASKETED/INCREASED SAFETY


Photometric Data — DATA SHOWN IS ABSOLUTE
5000K CCT, With Diffuser
REPORT NUMBER: FELED5CBUxxD

Luminaire Lumens: 5,289

POLAR CANDELA DISTRIBUTION ISOCANDELA PLOT ZONAL LUMEN SUMMARY

180° 170° 160° 150° 140° Zone Lumens % Lamp % Luminaire


1,700 -80° -60° -40° -20° 0° 20° 40° 60° 80° 0-30 1,326.7 25.1% 25.1%
80° 0-40 2,201.8 41.6% 41.6%
1,417 130°
60° 0-60 3,907.1 73.9% 73.9%
1,133
40° 60-90 1,149.8 21.7% 21.7%
120°
850 20°
70-100 671.2 12.7% 12.7%
90-120 209.3 4% 4%
110° 0°
567 0-90 5,057.0 95.6% 95.6%
-20°
283 100° 90-180 232.5 4.4% 4.4%
-40° 0-180 5,289.5 100% 100%
0.00 90°
-60°
283 80° -80° LUMENS PER ZONE
567
Zone Lumens % Total Zone Lumens % Total
70° 0-10 158.0 3.0% 90-100 100.4 1.9%
850 Cd: 1,501, 90% Cd: 667, 40% 10-20 458.6 8.7% 100-110 64.4 1.2%
Cd: 1,251, 75% Cd: 500, 30%
60° Cd: 1,001, 60% Cd: 334, 20% 20-30 710.2 13.4% 110-120 44.6 0.8%
1,133 Cd: 834, 50% Cd: 167, 10% 30-40 875.0 16.5% 120-130 15.6 0.3%
1,417 Point of Max Cd: 1,668.9 40-50 913.0 17.3% 130-140 3.0 0.1%
50°
50-60 792.3 15.0% 140-150 1.8 0%
1,700 60-70 579.0 10.9% 150-160 1.4 0%
0° 10° 20° 30° 40°
70-80 370.8 7.0% 160-170 1.0 0%
Max CD -45° H 80-90 200.1 3.8% 170-180 0.4 0%
-0° H
-90° H
5000K CCT, With Diffuser
REPORT NUMBER: FELED7CBUxxD

Luminaire Lumens: 7,038

POLAR CANDELA DISTRIBUTION ISOCANDELA PLOT ZONAL LUMEN SUMMARY

180° 170° 160° 150° 140° Zone Lumens % Lamp % Luminaire


2,300 -80° -60° -40° -20° 0° 20° 40° 60° 80° 0-30 1,784.7 24.9% 24.9%
80° 0-40 2,966.4 41.3% 41.3%
1,917 130°
60° 0-60 5,282.4 73.6% 73.6%
1,533 40° 60-90 1,560.7 21.7% 21.7%
120° 70-100 911.3 12.7% 12.7%
1,150 20°
90-120 304.8 4.2% 4.2%
110° 0°
767 0-90 6,843.1 95.3% 95.3%
-20°
383 100° 90-180 337.9 4.7% 4.7%
-40° 0-180 7,180.9 100% 100%
0.00 90°
-60°
383 80° -80° LUMENS PER ZONE
767 Zone Lumens % Total Zone Lumens % Total
70°
Cd: 2,010, 90% Cd: 893, 40%
0-10 211.9 3.0% 90-100 138.3 1.9%
1,150
Cd: 1,675, 75% Cd: 670, 30% 10-20 615.8 8.6% 100-110 97.5 1.4%
60° Cd: 1,340, 60% Cd: 447, 20%
1,533
Cd: 1,117, 50% Cd: 223, 10%
20-30 957.1 13.3% 110-120 69.0 1%
30-40 1,181.6 16.5% 120-130 22.9 0.3%
1,917 50° Point of Max Cd: 2,233.7 40-50 1,235.6 17.2% 130-140 3.9 0.1%
2,300
50-60 1,080.4 15.0% 140-150 2.5 0%
0° 10° 20° 30° 40° 60-70 787.7 11.0% 150-160 1.9 0%
Max CD -45° H 70-80 499.0 6.9% 160-170 1.4 0%
80-90 274.0 3.8% 170-180 0.5 0%
-0° H
-90° H

Visit our website at www.emerson.com or contact us at (800) 621-1506. 13


© May 2019
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety

ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10
LED/AREA: ATEX/IECEX ENCLOSED AND GASKETED/INCREASED SAFETY

Photometric Data — DATA SHOWN IS ABSOLUTE


5000K CCT, Without Diffuser
REPORT NUMBER: FELEDI3CBUxxD

Luminaire Lumens: 1,885

POLAR CANDELA DISTRIBUTION ISOCANDELA PLOT ZONAL LUMEN SUMMARY

180° 170° 160° 150° 140° Zone Lumens % Lamp % Luminaire


500 -80° -60° -40° -20° 0° 20° 40° 60° 80° 0-30 298.8 15.8% 15.8%
80° 0-40 524.2 27.8% 27.8%
417 130°
60° 0-60 1,113.0 59% 59%
333 40° 60-90 681.6 36.1% 36.1%
120°
250 20°
70-100 404.4 21.4% 21.4%
90-120 88.3 4.7% 4.7%
110° 0°
167 0-90 1,794.6 95.2% 95.2%
-20°
83 100° 90-180 91.1 4.8% 4.8%
-40° 0-180 1,885.8 100% 100%
0.00 90°
-60°
83 80° -80° LUMENS PER ZONE
167
Zone Lumens % Total Zone Lumens % Total
70° 0-10 35.5 1.9% 90-100 61.1 3.2%
250 Cd: 441, 90% Cd: 196, 40% 10-20 102.3 5.4% 100-110 22.7 1.2%
Cd: 368, 75% Cd: 147, 30%
60° Cd: 294, 60% Cd: 98, 20% 20-30 161.0 8.5% 110-120 4.5 0.2%
333
Cd: 245, 50% Cd: 49, 10% 30-40 225.4 12.0% 120-130 1.1 0.1%
417 Point of Max Cd: 491.7 40-50 274.5 14.6% 130-140 0.6 0%
50°
50-60 314.3 16.7% 140-150 0.5 0%
500 60-70 338.3 17.9% 150-160 0.3 0%
0° 10° 20° 30° 40°
70-80 256.5 13.6% 160-170 0.2 0%
-0° H -45° H 80-90 86.7 4.6% 170-180 0.1 0%
-90° H

5000K CCT, Without Diffuser


REPORT NUMBER: FELEDI4CBUxxD

Luminaire Lumens: 2,616

POLAR CANDELA DISTRIBUTION ISOCANDELA PLOT ZONAL LUMEN SUMMARY

180° 170° 160° 150° 140° Zone Lumens % Lamp % Luminaire


690 -80° -60° -40° -20° 0° 20° 40° 60° 80° 0-30 415.1 15.9% 15.9%
80° 0-40 728.5 27.8% 27.8%
575 130°
60° 0-60 1,544.6 59% 59%
460 40° 60-90 938.5 35.9% 35.9%
120° 70-100 559.9 21.4% 21.4%
345 20°
90-120 129.0 4.9% 4.9%
110° 0°
230 0-90 2,483.1 94.9% 94.9%
-20°
115 100° 90-180 133.5 5.1% 5.1%
-40° 0-180 2,616.6 100% 100%
0.00 90°
-60°
115 80° -80° LUMENS PER ZONE
230 Zone Lumens % Total Zone Lumens % Total
70°
0-10 49.2 1.9% 90-100 86.8 3.3%
345 Cd: 613, 90% Cd: 272, 40%
Cd: 510, 75% Cd: 204, 30% 10-20 142.1 5.4% 100-110 35.5 1.4%
60° Cd: 408, 60% Cd: 136, 20% 20-30 223.8 8.6% 110-120 6.8 0.3%
460
Cd: 340, 50% Cd: 68, 10% 30-40 313.4 12.0% 120-130 1.8 0.1%
575 50° Point of Max Cd: 684.9 40-50 381.1 14.6% 130-140 1.0 0%
50-60 434.9 16.6% 140-150 0.7 0%
690
0° 10° 20° 30° 40°
60-70 465.4 17.8% 150-160 0.5 0%
70-80 351.9 13.4% 160-170 0.4 0%
-0° H -45° H 80-90 121.2 4.6% 170-180 0.1 0%
-90° H

14 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2019
ATX™ FELED Series Nonmetallic LED Luminaires
Standard and Emergency Battery Back-Up, Increased Safety

ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 – IK10

LED/AREA: ATEX/IECEX ENCLOSED AND GASKETED/INCREASED SAFETY


Photometric Data — DATA SHOWN IS ABSOLUTE
5000K CCT, Without Diffuser
REPORT NUMBER: FELEDI5CBUxxD

Luminaire Lumens: 3,259

POLAR CANDELA DISTRIBUTION ISOCANDELA PLOT ZONAL LUMEN SUMMARY


180° 170° 160° 150° 140° Zone Lumens % Lamp % Luminaire
840
-80° -60° -40° -20° 0° 20° 40° 60° 80° 0-30 492.7 15.1% 15.1%
700 130° 80° 0-40 871.6 26.7% 26.7%
60° 0-60 1,896.1 58.2% 58.2%
560
120° 40° 60-90 1,230.2 37.7% 37.7%
420
20°
70-100 730.9 22.4% 22.4%
110° 90-120 130.1 4% 4%
280 0°
0-90 3,126.3 95.9% 95.9%
140 100° -20°
90-180 133.6 4.1% 4.1%
-40° 0-180 3,259.9 100% 100%
0.00 90°
-60°
140 80°
-80° LUMENS PER ZONE
280
70° Zone Lumens % Total Zone Lumens % Total
420 0-10 56.9 1.7% 90-100 94.5 2.9%
Cd: 747, 90% Cd: 332, 40% 10-20 166.1 5.1% 100-110 29.9 0.9%
60° Cd: 622, 75% Cd: 249, 30%
560
Cd: 498, 60% Cd: 166, 20% 20-30 269.7 8.3% 110-120 5.7 0.2%
Cd: 415, 50% Cd: 83, 10% 30-40 378.9 11.6% 120-130 1.4 0%
700 50°
Point of Max Cd: 831.2 40-50 474.7 14.6% 130-140 0.8 0%
840 50-60 549.7 16.9% 140-150 0.6 0%
0° 10° 20° 30° 40°
60-70 593.9 18.2% 150-160 0.4 0%
Max CD 70-80 470.7 14.4% 160-170 0.3 0%
-0° H -45° H 80-90 165.7 5.1% 170-180 0.1 0%
-90° H
5000K CCT, Without Diffuser
REPORT NUMBER: FELEDI7CBUxxD

Luminaire Lumens: 4,200

POLAR CANDELA DISTRIBUTION ISOCANDELA PLOT ZONAL LUMEN SUMMARY

180° 170° 160° 150° 140° Zone Lumens % Lamp % Luminaire


1,100 -80° -60° -40° -20° 0° 20° 40° 60° 80° 0-30 621.8 14.8% 14.8%
80° 0-40 1,099.5 26.2% 26.2%
917 130°
60° 0-60 2,396.9 57.1% 57.1%
733 40° 60-90 1,619.2 38.6% 38.6%
120° 70-100 979.1 23.3% 23.3%
550 20°
90-120 179.5 4.3% 4.3%
110° 0°
367 0-90 4,016.1 95.6% 95.6%
-20°
183 100° 90-180 184.2 4.4% 4.4%
-40° 0-180 4,200.3 100% 100%
0.00 90°
-60°
183 80° -80° LUMENS PER ZONE
367 Zone Lumens % Total Zone Lumens % Total
70°
0-10 71.9 1.7% 90-100 127.5 3%
550 Cd: 960, 90% Cd: 426, 40%
Cd: 800, 75% Cd: 320, 30% 10-20 210.0 5.0% 100-110 43.9 1%
60° Cd: 640, 60% Cd: 213, 20% 20-30 339.8 8.1% 110-120 8.1 0.2%
733
Cd: 533, 50% Cd: 107, 10% 30-40 477.8 11.4% 120-130 1.9 0%
917 50° Point of Max Cd: 1,067.0 40-50 599.1 14.3% 130-140 1.0 0%
50-60 698.3 16.6% 140-150 0.8 0%
1,100
0° 10° 20° 30° 40°
60-70 767.6 18.3% 150-160 0.6 0%
70-80 633.3 15.1% 160-170 0.4 0%
Max CD 80-90 218.3 5.2% 170-180 0.1 0%
-0° H -45° H
-90° H

Visit our website at www.emerson.com or contact us at (800) 621-1506. 15


© May 2019

You might also like