Professional Documents
Culture Documents
12 Odd - Study of PPM Using DC Input
12 Odd - Study of PPM Using DC Input
12 Odd - Study of PPM Using DC Input
Experiment 12.a
Aim : Study of PPM using DC Input
Equipment :
Scientech 2110 with Power Supply cord
Scientech Oscilloscope with connecting probe
Connecting cords
Connection Block Diagram:
Procedure:
Connect the circuit as shown in next figure and also described below for clarity.
•Connect the DC output to input of PPM block.1
Switch ‘On’ the Power Supply & Oscilloscope.
Observe the output of PPM block at TP7.
Vary the DC output while observing the output of PPM block. You will observe a shift
in position on the pulses for awhile during DC voltage variation
You can also connect an external lower frequency signal (Sine wave; 3Hz to 10 Hz;
3Vpp amplitude) to observe the shifting phenomenon in PPM signal.
Switch ‘Off’ the Power Supply.
1
ANALOG COMMUNICATION;4th SEM
Deptt. OF ETC,JIST Expt 12.a PPM
Vary the amplitude of sine wave and observe the pulse position modulation.
Switch ‘On’ fault No. 1, 2, & 6 one by one & observe their effects in pulse position
modulation output and try to locate them.
Switch ‘Off’ the Power Supply.