Experiment 14
Aim :Study of PWM using different Sampling Frequency
Equipments :
Scientech 2110 with Power Supply cord
Scientech Oscilloscope with connecting probe
Connecting cords
Connection Block Diagram:
Procedure:
Connect the circuit as shown in next figure and also described below for clarity.
• 1 KHz sine wave output of Function Generator block to modulation input of
PWM block.
• 8 KHz square wave output to pulse input of PWM block.
Switch ‘On’ the Power Supply & Oscilloscope.
Observe the PWM outputs at TP (10) together with Modulation signal input TP
(9). [CH1(Y) – 5V; CH2(X) – 2V; Time base – 0.1mS]
1
ANALOG COMMUNICATION;4th SEM
Deptt. OF ETC,JIST Expt 14PwM
Experiment 14
Aim:Study of Pulse Width Demodulation
Equipments :
Scientech 2110 with Power Supply cord
Scientech Oscilloscope with connecting probe
Connecting cords
Connection Block Diagram:
Procedure:
Connect the circuit as shown in next figure and also described below for clarity.
• 1 KHz sine wave output of Function Generator block to modulation input of PWM
block.
• 8 KHz square wave output to pulse input.
• Output of PWM to input of low pass filter.
• Output of low pass filter to input of AC Amplifier.
Switch ‘On’ the Power Supply & Oscilloscope.
3
ANALOG COMMUNICATION;4th SEM
Deptt. OF ETC,JIST Expt 14PwM
Now, connect the pulse input in the pulse width modulation block to the different
frequencies available on board viz. 8, 16, 32 KHz and observe their demodulated
waveforms.
Try varying the amplitude of sine wave signal; you will observe that the output signal
varies similarly.
Switch ‘On’ fault no, 1, 2, 5 & 8 one by one at a time. Observe their effects on final
output and try to locate them.