Camber Camber Thickness

Clear Span of All Beams = 4 m Clear Span Description Clear Span Camber
Camber of All Slabs = 8 mm All Beams 4 m Clear Span 10 mm
Clear Span of Cantilever Slab = 2 m Clear Span Cantilever Beam 3 m Clear Span 50 mm
Camber of All Beams = 10 mm All Slabs 3 m Clear Span 8 mm
Clear Span of Cantilever Beam = 3 m Clear Span Cantilever Slab 2 m Clear Span 14 mm
Camber of Cantilever Slab = 14 mm
Clear Span of All Slabs = 3 m Clear Span Minimum Thickness of Non Pre-stressed
Camber of Cantilever Beam = 50 mm Beams or One-way Slab
Description Solid One- Beams/ Ribbed
Philippine Seismic Zone Way Slab One-Way Slab
ø of Steel Bolts in Palawan = 12 mm Simply L/20 L/16
ø of Steel Bolts in Sorsogon = 16 mm Supported
ø of Steel Bolts in Legazpi = 16 mm One End L/24 L/18.5
ø of Steel Bolts in Tawi-Tawi = 12 mm Continuous
ø of Steel Bolts in Boracay = 16 mm Both Ends L/28 L/21
ø of Steel Bolts in Basilan = 16 mm Continuous
ø of Steel Bolts in Rawis = 16 mm Cantilever L/10 L/8
ø of Steel Bolts in Dagupan= 16 mm
ø of Steel Bolts in Cebu = 16 mm Philippine Seismic Zone
ø of Steel Bolts in Sulu = 12 mm Zone # Locations Steel Bolts ø
Seismic Zone of Boracay = Zone 4 2 Sulu, Tawi-Tawi, 12 mm
Seismic Zone of Sulu = Zone 2 Palawan
Seismic Zone of Sorsogon = Zone 4 4 Rest of The Philippines 16 mm
Seismic Zone of Palawan = Zone 2
Seismic Zone of Makati = Zone 4 Air Space Requirements
Seismic Zone of BGC = Zone 4 DESCRIPTION Air Space Ceiling
Seismic Zone of Samar = Zone 4 (cu.m) Height
Seismic Zone of Tawi-Tawi = Zone 2 School Room 3 cu.m 3.00m
Seismic Zone of Siargao = Zone 4 Workshop & Offices, 12 cu.m 3.00m
Seismic Zone of Tagaytay = Zone 4 Facilities
Habitable Room 14 cu.m 2.40m
Minimum Thickness of Non Pre-stressed One-
way Slab
Cantilever = L/10
One End Continuous = L/24
Simply Supported = L/20
Both Ends Continuous = L/28
Minimum Thickness of Non Pre-stressed
Beams/ Ribbed One-way Slab
Both Ends Continuous = L/21
Simply Supported = L/16
One End Continuous = L/18.5
Cantilever = L/8

Philippine Seismic Zone


Zone # Locations Steel Bolts ø
2 Sulu, Tawi-Tawi, 12 mm
Palawan
4 Rest of The Philippines 16 mm
Tagayun Concrete Mixture Proportion
CLASS PROPORTION CEMENT SAND GRAVEL Strength After 28 Days
AAA 1:1:2 - - - -
AA 1 : 1-1/2 : 3 10.46 0.42 0.84 4000 – 3500 PSI
A 1:2:4 7.85 0.42 0.84 3000 – 2500 PSI
B 1 : 2-1/2 : 5 6.49 0.44 0.87 2000 – 1500 PSI
C 1:3:6 5.49 0.44 0.89 1000 – 500 PSI
D 1 : 3-1/2 : 7 4.82 0.45 0.91 Less than 500 PSI
Imhotep Concrete Mixture Proportion
CLASS PROPORTION CEMENT SAND GRAVEL STRENGTH
40 kg 50kgs
AAA 1:1:2 - - - - -
AA 1 : 1-1/2 : 3 12 9.5 0.5 1 4000 PSI
A 1:2:4 9 7 0.5 1 3500 PSI
B 1 : 2-1/2 : 5 7.5 6 0.5 1 3000 PSI
C 1:3:6 6 5 0.5 1 2500 PSI
D 1 : 3-1/2 : 7 5 4 0.5 1 2000 PSI
Concrete Mixture Uses
CLASS USES
AAA Pre-stressed & Post-Tensioned
AA Under Water Retaining Walls, Shear Walls & Elevator Core Walls
A Footings, Piers, Columns, Girders, Beams, Joist & Slabs
B Slabs on Fills & Non-Load Bearing Walls or 4” CHB
C Concrete Plant Boxes and Parapet Walls
D Plant Boxes, Footpaths, Walkways & Lean Concrete

Subdivision Minimum Lot Area


Description PD 957 BP 220
Medium Cost Open Market Socialized Economic
Single Detached 100 sq.m 120 sq.m 64 sq.m 72 sq.m
Duplex/ Single Attached 80 sq.m 96 sq.m 48 sq.m 54 sq.m
Rowhouse 50 sq.m 60 sq.m 28 sq.m 36 sq.m
Minimum Floor Area
House 30 sq.m 42 sq.m 18 sq.m 22 sq.m
Condo 22 sq.m 36 sq.m

PD 957 Condominium Floor Areas PD 957 Min. Lot Dimension for Subdivision
DESCRIPTION AREA DESCRIPTION MEDIUM OPEN
SINGLE OCCUPANCY COST MARKET
Studio Room 18 sq.m Single Detached - -
Studio Room for Student 12 sq.m Corner Lot 12.0 m 12.0 m
FAMILY OCCUPANCY Regular Lot 10.0 m 10.0 m
Medium Cost 22 sq.m Irregular Lot 6.0 m 6.0 m
Open Market 36 sq.m Interior Lot 3.0 m 3.0 m
Duplex 8.0 m 8.0 m
Rowhouse 4.0 m 4.0 m