CaSys.Cabling Strenghts
Practical: all openings can be rapidly assembled and removed by one person.
4/2 www.himelenclosures.com
VDAC
CaSys.Cabling Strengths
1 Innovative. 2 Time-saving.
Side cable entry is the most ergonomic and effi- All openings can be rapidly assembled and
cient on the market (patented): “Easy Cable removed. Only one person is needed to remove
Access”. The upper and lower cut-outs, being and reassemble the cladding elements. The feet
flush to the structure, allow the strands to be pre- are adjustable from the inside.
pared before the rack is installed. These cut-outs
also facilitate maintenance and are closed up
when the side panels are fitted.
www.himelenclosures.com 4/3
VDAC
CaSys.Cabling Strengths
5 Ergonomic. 6 Security.
Cable channelling is facilitated by: The panel latches may be fitted with a key loc-
- ready cut-out side cable passage areas at the king system (the key is identical for all panels).
top and bottom.
- ready cut-out rear cable passage areas at the
bottom.
- wide opening on the roof, offset towards
the rear and fitted with a removable plate.
Permits the incorporation of active equipment in
the upper part and the passage of cables at the
rear.
- wide opening in the lower part.
4/4 www.himelenclosures.com
VDAC
CaSys.Cabling Strengths
9 Ingenious. 10 Practical.
The pivot and guide system allow the panels to The units have markings on the front and side
be replaced very rapidly and safely. faces for rapid installation of the equipment. The
19” uprights are easily depth-adjustable on-site.
www.himelenclosures.com 4/5
VDAC Presentation
Rack composition
Top and bottom frames mechanically assembled with
Torx screws to vertical uprights, ensuring a rigid frame-
work.
Cut-out roof, closed with removable plain panel.
2 19” uprights, in treated steel, set back 100 mm Equipped Casys.Cabling rack, cladding in black
from front face and depth adjustable on a 25 mm step. RAL 9011
Delivered on a pallet, film-wrapped.
1 height: 42U.
Equipped Casys.Cabling standard 2 widths: 600 and 800 mm.
rack kit 3 depths: 600, 800 and 1000 mm.
1 height: 42U.
Rack composition
2 widths: 600 and 800 mm.
Composition identical to the equipped rack above, delivered
3 depths: 600, 800 and 1000 mm. assembled.
4/6 www.himelenclosures.com
VDAC Section table
CaSys.Cabling
Standar rack
Width 600 mm
Number Height Width Depth Rack Extension 19” rear additional 100 mm plinth Castors for Cable gland
of U rack uprights RAL7035 handling trim RAL7035
24 U 1200 600 600 VDAC 24U66 2PLVDC 24U6 BRF 24 ZUN 66/100VDAC RUF/VDAC -
24 U 1200 600 800 VDAC 24U68 2PLVDC 24U8 BRF 24 ZUN 68/100VDAC RUF/VDAC -
24 U 1200 600 1000 VDAC 24U610 2PLVDC 24U10 BRF 24 ZUN 610/100VDAC RUF/VDAC -
29 U 1400 600 600 VDAC 29U66 2PLVDC 29U6 BRF 29 ZUN 66/100VDAC RUF/VDAC -
29 U 1400 600 800 VDAC 29U68 2PLVDC 29U8 BRF 29 ZUN 68/100VDAC RUF/VDAC -
33 U 1600 600 600 VDAC 33U66 2PLVDC 33U6 BRF 33 ZUN 66/100VDAC RUF/VDAC -
33 U 1600 600 800 VDAC 33U68 2PLVDC 33U8 BRF 33 ZUN 68/100VDAC RUF/VDAC -
38 U 1800 600 600 VDAC 38U66 2PLVDC 38U6 BRF 38 ZUN 66/100VDAC RUF/VDAC -
38 U 1800 600 800 VDAC 38U68 2PLVDC 38U8 BRF 38 ZUN 68/100VDAC RUF/VDAC -
42 U 2000 600 600 VDAC 42U66 2PLVDC 42U6 BRF 42 ZUN 66/100VDAC RUF/VDAC -
42 U 2000 600 800 VDAC 42U68 2PLVDC 42U8 BRF 42 ZUN 68/100VDAC RUF/VDAC -
42 U 2000 600 1000 VDAC 42U610 2PLVDC 42U10 BRF 42 ZUN 610/100VDAC RUF/VDAC -
47 U 2200 600 600 VDAC 47U66 2PLVDC 47U6 BRF 47 ZUN 66/100VDAC RUF/VDAC -
47 U 2200 600 800 VDAC 47U68 2PLVDC 47U8 BRF 47 ZUN 68/100VDAC RUF/VDAC -
Width 800 mm
Number Heigth Width Depth Rack Extension 19” rear additional 100 mm plinth Castors for Cable gland
of U rack uprights RAL7035 handling trim RAL7035
24 U 1200 800 600 VDAC 24U86 2PLVDC 24U6 BRF 24 ZUN 86/100VDAC RUFVDAC PV24
24 U 1200 800 800 VDAC 24U88 2PLVDC 24U8 BRF 24 ZUN 88/100VDAC RUFVDAC PV24
24 U 1200 800 1000 VDAC 24U810 2PLVDC 24U10 BRF 24 ZUN 810/100VDAC RUFVDAC PV24
29 U 1400 800 600 VDAC 29U86 2PLVDC 29U6 BRF 29 ZUN 86/100VDAC RUFVDAC PV29
29 U 1400 800 800 VDAC 29U88 2PLVDC 29U8 BRF 29 ZUN 88/100VDAC RUFVDAC PV29
33 U 1600 800 600 VDAC 33U86 2PLVDC 33U6 BRF 33 ZUN 86/100VDAC RUFVDAC PV33
33 U 1600 800 800 VDAC 33U88 2PLVDC 33U8 BRF 33 ZUN 88/100VDAC RUFVDAC PV33
38 U 1800 800 600 VDAC 38U86 2PLVDC 38U6 BRF 38 ZUN 86/100VDAC RUFVDAC PV38
38 U 1800 800 800 VDAC 38U88 2PLVDC 38U8 BRF 38 ZUN 88/100VDAC RUFVDAC PV38
42 U 2000 800 600 VDAC 42U86 2PLVDC 42U6 BRF 42 ZUN 86/100VDAC RUFVDAC PV42
42 U 2000 800 800 VDAC 42U88 2PLVDC 42U8 BRF 42 ZUN 88/100VDAC RUFVDAC PV42
42 U 2000 800 1000 VDAC 42U810 2PLVDC 42U10 BRF 42 ZUN 810/100VDAC RUFVDAC PV42
47 U 2200 800 600 VDAC 47U86 2PLVDC 47U6 BRF 47 ZUN 86/100VDAC RUFVDAC PV47
47 U 2200 800 800 VDAC 47U88 2PLVDC 47U8 BRF 47 ZUN 88/100VDAC RUFVDAC PV47
Equipped
CaSys.Cabling
rack black RAL 9011
Number Heigth Width Depth Rack 19” Rear Blanking plate
of U RAL 9011 additional uprights with 3 fans
42 U 2000 600 600 VDAC 42U66N BRF 42 ECVT3V 440
42 U 2000 600 800 VDAC 42U68N BRF 42 ECVT3V 440
42 U 2000 600 1000 VDAC 42U610N BRF 42 ECVT3V 440
42 U 2000 800 600 VDAC 42U86N BRF 42 ECVT3V 440
42 U 2000 800 800 VDAC 42U88N BRF 42 ECVT3V 440
42 U 2000 800 1000 VDAC 42U810N BRF 42 ECVT3V 440
www.himelenclosures.com 4/7
VDAC Dimensions
Width 600 mm
Montant 19”
A-100
448
536,5
MIN/WAXI : AT18/AT25
14
A-1975
118
25 227
30
Width 800 mm
448
451
465
736,5
A-1975
A-136
227
Number U Heigth
467/667
400 A (mm)
24 U 1175
29 U 1400
33 U 1575
400 38 U 1800
42 U 1975
400
47 U 2200
450
600/800
4/8 www.himelenclosures.com
VDAC Accessories
www.himelenclosures.com 4/9
VDAC Cladding accessories
4/10 www.himelenclosures.com
VDAC Cladding accessories
Roll of 10 m of protec-
Protective strip reference
tive strip in rubber.
TPV
www.himelenclosures.com 4/11
VDAC Cladding accessories
Locking system
Coupling kit
Blanking plate for cable entries between racks positioned side by side.
4/12 www.himelenclosures.com
VDAC Cladding accessories
Lifting eyes
Earthing collectors
www.himelenclosures.com 4/13
VDAC Base accessories
Handling castors
4/14 www.himelenclosures.com
VDAC Base accessories
Plinth
Anti-tilt accessory
www.himelenclosures.com 4/15
VDAC Installation accessories
For mounting in inter- Supports ref. Rack width (mm) Rack depth (mm)
mediate position on the SBRF 66 600 600
framework to reinforce SBRF 68 600 800
rigidity of the 19” chassis SBRF 86 800 600
and/or to support SBRF 88 800 800
cables. SBRF 610 600 1000
Set of 2 supports and SBRF 810 800 1000
the necessary fixings for
mounting.
Depth adjustment on
a 25 mm step.
For fitting on frame- Supports ref. Rack width (mm) Depth (mm)
work instead of 19” SBMF 66 600 600
upright supports, allowing SBMF 68 600 800
the mounting of metric SBMF 86 800 600
step uprights. SBMF 88 800 800
Set of 2 supports and
the necessary fixings for
mounting.
4/16 www.himelenclosures.com
VDAC Accessories
For mounting bet- Reference Rack depth (mm) Fixing distance (mm)
ween front and rear TVP 256 600 258
19” uprights. TVP 456 800 458
Enable cables to be TVP 656 1000 658
fixed using cable ties.
Lot of 2 pieces.
www.himelenclosures.com 4/17
VDAC Ventilation accessories
4/18 www.himelenclosures.com
VDAC Accessories
www.himelenclosures.com 4/19