Professional Documents
Culture Documents
Manual of Rebar Rust Test Data Processing Software
Manual of Rebar Rust Test Data Processing Software
Software
Operation Manual
Contents
further more.
6) To automatic generate the testing data table in the style of
Microsoft Excel (Ext.XLS).The information of the engineering
and object is registered in the table.
This software consists of four different type files, as shown in tab. 1.1.
tab.1.1 File type list
Type Ext. Description
Data file XS Measuring data file
Data table file XLS The Rebar rust test data table file
Graphics file BMP Bitmap file
Text file TXT ASCII code file
2.1 Installation
1. Please insert the CD or U-disk into the computer , find out the
“RustSetup.exe” file in the root directory and run it, the installing
guide to unzip the needed files as shown in (fig. 2.1), after
unzipping file finish, the InstallShield Wizard is automatically
started up (fig 2.2) to guide the user how to install the software.
After some minutes later, the welcome interface appears as
displayed in (fig. 2.3)
2. On the welcome interface if Cancel button is pressed to exit the
installing program, after Next button is pressed to appear the
customer information input dialog box as shown in fig2.4.
2.2 Running
After install completion, you can use a mouse to choose step by step
Start→All Programs→Beijing ZBL→Rebar Rust Test Data
Processing Software→Rebar Rust Test Data Processing Software,
then run this process software. Besides, you can double click Rebar
Rust Test Data Processing Software icon to run this process software as
well.
2.3 Uninstallation
uninstallation.
This software interface is made up of eight parts (see fig. 3.1): Title bar,
Menu bar, Toolbar, Status bar, Object Info. Area, Object List Area,
Data Area, Graph Area.
the Menu bar, as shown in fig. 3.1. With each menu item is clicked to
appear one rolling down menu, which consists of a series functions.
The five item’s submenus contain all functions this software
possesses. When some menu item are in a grey color state that
expresses that its current function is inactive.
3. The Toolbar are made up of a series of buttons, as shown in fig. 3.2 ,
each button can have one common-use function, although which are
already contained in command menu, for these common-use
commands, it is more convenient for the user to use toolbar buttons
to complete the related operation. If you make mouse stay at one
button for a moment, this button’s function tips can appear on the
screen automatically. When this button is grey color state that means
the current function button is inactive.
The user can click the mouse’s right button in the object list area, to
popup a menu as shown in fig. 3.5 in which the function is same as
the corresponding item in the edit menu.
7. Data Area is used to display the current object measuring point’s
original measuring data, as shown in fig. 3.6. If there is a “----”
display that means that there is no data. The user can modify the
measurement data easily if necessary.
3.2 Menus
1.Open
By using this software, the user can open the data file which is
transmitted from the instrument to computer (the ext. is XS). After
opening data, as shown in fig.3.1, the corresponding data or
information can be displayed in the related area in the interface.
then a dialog box is appeared to ask if you want to overwrite this file, if
the user choose Yes, so that the existed file is overwritten; if user
choose No, so that the saving is given up and the interface return as
shown in the fig. 3.8, the user can input a new file name again.
one or more object, then press OK button, the “save as” dialog box is
appeared as shown in the fig.3.8, the user can input file name and press
the Save button to complete it.
5. Save bitmap
name in File name or from file list frame to choose the converting file.
After clicking the Open button, the file can be converted into the XS
format and be saved. The name and saved position of the XS format file
are same with the data file. The XS format file can be automatically
open after the converting work.
8.Merge file
This function is mostly used to combine more than two XS files as one
file, to make the user manage the files more conveniently.
9. Print
After the user choose Print menu, the print dialog box as shown in the
fig.3.13 is appeared. Choose the object to be printed (All objects or
Current object), print contents(Data table, Detection Data, Contour,
Color Gradation, Grey Image, Frequency Map, Statistical Result)and
then press OK button, so that the selected contents of the selected
object in current file will be printed out. Or press Cancel button to give
up the print operation.
setup menu item, the “print setup” dialog box is appeared as shown in
the fig. 3.15, the user can choose printer model in Printer, choose paper
size in Paper, choose printout orientation (portrait or landscape) in
Orientation, then press OK button to make the setup to be effective; or
press Cancel , to give up the setup.
NOTE:This software is mainly available for A4 and B5
paper, if other paper is chosen, an abnormal print may be
appeared.
12.Exit
To close currently data file and exit the program. Before exiting, if the
data has been modified, a saving hint is appeared.
1. Project information
After the user choose Project information menu item, a dialog box is
appeared as shown in fig.3.16, the user can setup Project, Construction,
Examiner, Certificate, Report No. and so on, as the setup is completed,
you can press OK button to accept this input information; or press
Cancel button to give up this input information.
If the current project information is same as or similar to that of a saved
file, the user can press Read button and choose this file appeared in
“open file” dialog box and press Open button, the project information
of this file is read out and filled in the dialog box, the user can make a
slight modification or without modification, the user press Default
button to make the last saved project information read out and fill in the
dialog box.
can adjust month, or click the month ( for example: May) position to
choose month that appear in the month list; 3) Using the mouse to click
date number, the user can adjust date. Besides, the user can click any
position beyond the date input interface, then the interface is
disappeared and the date is updated.
All input date position in other dialog box or interface can be appeared
as shown in the fig. 3.17, the input method is same as well.
2. Options
After the user choose Options menu item, a dialog box is appeared as
shown in fig. 3.18, the user can setup Display mode ,The evaluation
rules of corrosion degree and so on, after the setup is completed, the
user press OK button to accept the setup; or press Cancel button to give
up the setup.
appeared “open file” dialog box choose a XS file, then press the Open
button, All objects of the selected file can be shown in the Objects list
frame, the user can choose the objects to be added from this list(the
object in blue color are pitched on), then press the Add button, so that
the chosen objects are added to the current file; or press the Exit button
to give up adding.
1.Data table
by the Max. voltage ,Min. voltage and Contour interval in the Options
dialog box.
1. Data transmission
After the measurement completion, the user can use this menu function
to make the measuring data stored in the instrument transfer to a
computer in order to carry out evaluation and keep them in an archive
file. The procedure is as following:
1) To connect the rebar rust detector’s USB port with a computer’s
USB port by using the special transmission line.
NOTE :Before connection, it is better to switch off the rebar
Hotline:86-010-51290405 30 Fax: 86-010-51290406
Manual of Rebar Rust Test Data Processing Software
the user should not carry out other operations in the computer,
or it may cause abnormal phenomenon.
1. Simplified Chinese
There’re two edition, simplified Chinese and English edition, of this
software. If choose this menu, the user can change to simplified
Chinese edition. If the current edition is simplified Chinese, then this
menu is inactive.
2. English
There’re two edition, simplified Chinese and English edition, of this
software. If choose this menu, the user can change to English edition.
If the current edition is English, then this menu is inactive.
1. Help topics
The menu mainly offer the help for software operation, when the user
meets the problem in using the data process software, the user can
choose this item or 【F1】key, then press Contents or Index to find out
the solution in the appeared window.
2. ZBL Homepage
After choosing this menu item, the user can interlink to our company
internet Web homepage to know our company better.
3. E-mail to ZBL
After choosing this menu item, the user can use Outlook to send an
E-mail to our company to give us the feedback idea timely.
4. About
The menu to display company name, software name and version etc.
All C3 series rebar rust detector manufactured by our company use the
USB port to carry out the data transmission. When the user to carry out
data transmission at the first time and the computer without
corresponding driver software installed before, first of all, the user must
install USB driver, otherwise the data transmission can’t be carried out.
Before the user begin to install USB driver, the user must get USB
driver supplied by our company at first. The driver software can come
from two ways: one way is the CD or U-disk attached by our company
as the user purchase our product, there is a corresponding driver
program; the other way is from our company internet web “Download
Center→Tools” page to download “USB driver” (this driver is an
compressed file).
If the user install the driver with a CD ROM, who should put the driver
CD into the CD-ROM, and find the “USB Driver” folder under the root
of CD, then enter into the folder and run the UsbSetup.exe, then operate
according to the hints step by step, the driver software will be install on
the computer automatically.
If you download driver from network, please unzip this driver file at
first to some folder of the computer, then enter the folder and run the
UsbSetup.exe.
NOTE: If you have installed the USB driver of our other
instruments, such as Digital Rebounder, Floor Thickness Tester,
etc., you have no need to install the driver software again,
because they have no difference between each other completely.