Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Program options

The integrated EEPROM permits various program options to be called up. To gain access to
the program options, press the two speed buttons, and within 2 seconds press the two stroke
buttons simultaneously for a duration of 5 seconds. In total, there are 8 option levels
available with the possibility of selecting a further 8 options at each level.
The option level is indicated by the 3 stroke lift LEDs. Currently, there are 6 option levels
available.
Option level 0 is signaled, when none of the stroke lift LEDs is illuminated.
Options may be preselected at each option level (see table).
To change the option levels, activate the stroke lift buttons. To select the individual options,
use the stroke speed buttons.
Once an option has been selected, it may be stored by pressing the blade on/off button. The
LEDs flash briefly, confirming that the command has been acknowledged .
The machine has to be restarted for any changes to be activated.

Option level 0

The country version 2, 3 and 4 are preset and cannot be changed.


When one of the three country versions has been set and programmed at the option level 0,
the preset options are transferred to the following option levels.
If an option is changed and programmed at option level 1 to 5, the country version is
automatically set to 1. With country version 1, all options are freely selectable at option levels
1 to 5.
LLL Option level LLL Option
EE E EEE
DD D DDD
123 456
0 - country version 0 - unassigned
x 1 – no specific country setting
x 2 (USA): Albertson: activated for a duration of 15 seconds.
(option 1/3)
Start setting: high/high (option 2/0)
Servo support: off (option 3/0)
Mains voltage: 120 V~ (option 4/0)
Carriage speed: standard (option 5/0)
Blade start: blade off (option 6/0)
x x 3 (Euro): Albertson: deactivated (option 1/0)
Start setting: high/high (option 2/0)
Servo support: off (option 3/0)
Mains voltage: 230V~ (option 4/1)
Carriage speed: standard (option 5/0)
Blade start: blade off (option 6/1)
x 4 (Switzerland): low speed, extremely low speed,
otherwise like EURO version
x 1 - Albertson 0 – Albertson (blade cutoff) deactivated
x x 1 – Albertson active, 5 seconds
x x 2 – Albertson active, 10 seconds
x x x 3 – Albertson active, 15 seconds
x x 4 – Albertson active, 20 seconds
x x x 5 – Albertson active, 30 seconds
x x x 6 – Albertson active, 40 seconds
x x x x 7 – Albertson active, 60 seconds
x 2 – start setting 0 – number of strokes high / stroke lift high
x x 1 – number of strokes medium / stroke lift high
x x 2 – number of strokes low / stroke lift high
x x x 3 – number of strokes high / stroke lift medium
x x 4 – number of strokes medium / stroke lift medium
x x x 5 – number of strokes low / stroke lift medium
x x x 6 – number of strokes high / stroke lift low
x x x x 7 – number of strokes medium / stroke lift low
x x 3 – servo support 0 – servo support off
xx x 1 – stage 1
xx x 2 – stage 2
xx x x 3 – stage 3
xx x 4 – stage 4
xx x x 5 – stage 5
xx x x 6 – stage 6
xx x x x 7 – stage 7
x 4 – mains voltage 0 – 120V~
x x 1 – 230V~
x x 5 – carriage speed. 0 – standard
x x x 1 – low speed, extremely low speed (Switzerland)
x x 6 – blade start 0 – blade remains deactivated when machine is switched ON
x 1 – blade is activated when machine is switched ON


LED 1 to 3 - stroke lift automatic blade cutoff when the carriage is no longer
moved
LED 4 to 6 – stroke speed