GENERAL SPECIFICATION

CORROSION

GS EP COR 772

Thermal insulation (cold service)

02 10/2017 General revision


01 09/2015 General revision
00 09/2013 First issue (cancels and replaces GS EP PVV 772)
Rev. Date Purpose of the revision

Owning entity: DSO/IP/TEC Managing entity: DSO/IP/TEC/COR


Other Approving entity(ies):

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 2 of 65

Contents

1. Scope ....................................................................................................................... 4

2. Reference documents ............................................................................................. 4

3. Insulation Classes ................................................................................................... 7

4. Insulation systems .................................................................................................. 8

5. Fire resistance ......................................................................................................... 8

6. General Design ........................................................................................................ 8


6.1 General ........................................................................................................................... 8
6.1 Insulation supports .......................................................................................................... 8
6.2 Piping supports ............................................................................................................... 8
6.3 Insulation water-tightness ............................................................................................... 8
6.4 Surface preparation ........................................................................................................ 9
6.5 Insulation type and thickness .......................................................................................... 9
6.6 Extent of insulation .......................................................................................................... 9

7. Materials................................................................................................................. 10
7.1 General ......................................................................................................................... 10
7.2 Insulating materials ....................................................................................................... 10
7.3 Protective cladding ........................................................................................................ 11
7.4 Insulation securement ................................................................................................... 12
7.5 Anti-abrasive coating, sealant, adhesive and vapour barrier ......................................... 12
7.6 Pipe supports ................................................................................................................ 13

8. General conditions for execution of works......................................................... 14


8.1 Qualification requirements ............................................................................................ 14
8.2 Health, Safety and Environment .................................................................................... 14
8.3 Material supply, handling and storage ........................................................................... 14
8.4 Samples ........................................................................................................................ 15
8.5 Preliminary conditions ................................................................................................... 15
8.6 Pre-insulation ................................................................................................................ 15
8.7 Execution conditions ..................................................................................................... 15

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 3 of 65

9. Application............................................................................................................. 16
9.1 Application Procedure ................................................................................................... 16
9.2 Cellular Glass ............................................................................................................... 16
9.3 Polyisocyanurate (PIR) ................................................................................................. 17
9.4 Bonding adhesive ......................................................................................................... 18
9.5 Joint sealing .................................................................................................................. 18
9.6 Insulation securement ................................................................................................... 19
9.7 Vapour barrier and lamination layer .............................................................................. 19
9.8 Vapour stop .................................................................................................................. 19
9.9 Penetration and protrusion ............................................................................................ 19
9.10 Insulation supports ........................................................................................................ 20
9.11 Protective cladding - Glass Reinforced Polyester (GRP) ............................................... 20
9.12 Mastic vapour barrier and weatherproofing ................................................................... 21
9.13 Valves, flanges and removable parts ............................................................................ 21
9.14 Repairs ......................................................................................................................... 21

10. Tests, inspections and acceptance ..................................................................... 22


10.1 Tests ............................................................................................................................. 22
10.2 Inspection ..................................................................................................................... 22
10.3 Acceptance ................................................................................................................... 23

11. Technical documentation ..................................................................................... 23


11.1 Bid stage ....................................................................................................................... 23
11.2 Prior to work commencement........................................................................................ 24
11.3 At work completion ........................................................................................................ 24
Appendix 1 Description of insulation systems .................................................................... 25
Appendix 2 Material specifications ..................................................................................... 31
Appendix 3 Principle sketches ........................................................................................... 53

Revision summary....................................................................................................... 65

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 4 of 65

1. Scope
This general specification defines the technical requirements of Cold Service insulation
materials and application, for equipment and piping on onshore and offshore installations,
operating between ambient temperature and -180°C, i.e. Insulation Classes C and K.
The following are excluded:
• Equipment and piping:
- For hot service and cyclic (dual) service (GS EP COR 771)
- Buried
- Subject to acoustic protection.
• Subsea pipelines (GS EP SPS 008 & GS EP COR 226).

2. Reference documents
The reference documents listed below form an integral part of this General Specification.

External Documents
Unless otherwise stipulated, the applicable version of these documents, including relevant
appendices and addendums, is the latest revision published at the effective date of this
document.

Reference Title
AGI Q136 Arbeitsgemeinschaft Industriebau e.V. - Bestimmung hydrophober
Eigenschaften von Mineralfaserdämmstoffen
ASTM C165 Standard Test Method for Measuring Compressive Properties of
Thermal Insulations
ASTM C177 Standard test method for steady-state heat flux measurement and
thermal transmission properties by means of the guarded-hot-plate
apparatus
ASTM C203 Standard Test Methods for Breaking Load and Flexural Properties
of Block-Type Thermal Insulation
ASTM C240 Standard test methods of testing cellular glass insulation block
ASTM C303 Standard Test Method for Dimensions and Density of Preformed
Block and Board-Type Thermal Insulation
ASTM C461 Standard Test Methods for Mastics and Coatings Used With
Thermal Insulation
ASTM C534 Standard Specification for Preformed Flexible Elastomeric Cellular
Thermal Insulation in Sheet and Tubular Form
ASTM C552 Standard specification for cellular glass thermal insulation

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 5 of 65

Reference Title
ASTM C612 Standard Specification for Mineral Fiber Block and Board Thermal
Insulation
ASTM C764 Standard Specification for Mineral Fiber Loose-Fill Thermal
Insulation
ASTM C795 Standard Specification for Thermal Insulation for Use in Contact
with Austenitic Stainless Steel
ASTM C871 Standard Test Methods for Chemical Analysis of Thermal
Insulation Materials for Leachable Chloride, Fluoride, Silicate, And
Sodium Ions
ASTM D1475 Standard Test Method For Density of Liquid Coatings, Inks, and
Related Products
ASTM D1621 Standard test method for compressive properties of rigid cellular
plastics
ASTM D1622 Standard test method for apparent density of rigid cellular plastics
ASTM D1623 Standard Test Method for Tensile and Tensile Adhesion
Properties of Rigid Cellular Plastics
ASTM D1640 Standard Test Methods for Drying, Curing, or Film Formation of
Organic Coatings
ASTM D1644 Standard Test Methods for Non volatile Content of Varnishes
ASTM D2126 Standard Test Method for Response of Rigid Cellular Plastics to
Thermal and Humid Aging
ASTM D2369 Standard Test Method for Volatile Content of Coatings
ASTM D256 Standard Test Methods for Determining the Izod Pendulum Impact
Resistance of Plastics
ASTM D2583 Standard Test Method for indentation hardness of rigid plastics by
means of a Barcol impressor
ASTM D2842 Standard Test Method for Water Absorption of Rigid Cellular
Plastics
ASTM D3039 Standard Test Method for Tensile Properties of Polymer Matrix
Composite Materials
ASTM D412 Standard Test Methods for Vulcanized Rubber and Thermoplastic
Elastomers -Tension
ASTM D4541 Standard Test Method for Pull-Off Strength of Coatings Using
Portable Adhesion Testers
ASTM D6226 Standard Test Method for Open Cell Content of Rigid Cellular
Plastics

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 6 of 65

Reference Title
ASTM D648 Standard Test Method for deflection temperature of plastics under
flexural load in the edgewise position
ASTM D695 Standard Test Method for compressive properties of rigid plastics
ASTM D696 Standard Test Method for Coefficient of Linear Thermal Expansion
of Plastics Between -30°C and 30°C with a Vitreous Silica
Dilatometer
ASTM D790 Standard Test Methods for Flexural Properties of Unreinforced
and Reinforced Plastics and Electrical Insulating Materials
ASTM D882 Standard Test Method for Tensile Properties of Thin Plastic
Sheeting
ASTM D93 Standard Test Methods for Flash Point by Pensky-Martens Closed
Cup Tester
ASTM E228 Standard Test Method for Linear Thermal Expansion of Solid
Materials With a Push-Rod Dilatometer
ASTM E398 Standard Test Method for Water Vapor Transmission Rate of
Sheet Materials Using Dynamic Relative Humidity Measurement
ASTM E84 Standard test method for surface burning characteristics of
building materials
ASTM E96 Standard Test Methods for Water Vapor Transmission of Materials
ASTM F1249 Standard Test Method for Water Vapor Transmission Rate
Through Plastic Film and Sheeting Using a Modulated Infrared
Sensor
BS 2782-0 Methods of testing Plastics. Introduction
BS 476 (Parts 6; 7) Fire tests on building materials and structures. Method of test to
determine the classification of the surface spread of flame of
products - Parts 6; 7
DIN 4102-1 Fire behaviour of building materials and building components -
Part 1: Building materials; concepts, requirements and tests
EN 13501-1 Fire classification of construction products and building elements -
Part 1: Classification using data from reaction to fire tests
EN 1606 Thermal insulating products for building applications -
Determination of compressive creep
IMO 2010 FTP Code International Code for the Application of Fire Test Procedures
2010
ISO 37 Rubber, vulcanized or thermoplastic - Determination of tensile
stress-strain properties

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 7 of 65

Reference Title
ISO 527-3 Plastics. Determination of tensile properties - Part 3: Test
conditions for films and sheets
ISO 9000 Quality management systems - Fundamentals and vocabulary

Total General Specifications


Unless otherwise stipulated, the applicable version of these documents, including relevant
appendices and addendums, is the latest revision published.

Reference Title
GS EP COR 226 Materials for thermal insulation of pipeline, piping and subsea
components
GS EP COR 350 External protection of offshore and coastal structures and
equipment by painting
GS EP COR 771 Thermal insulation (hot and dual service)
GS EP ICS 002 2D CAD Process Schematics
GS EP PVV 111 Piping design specification
GS EP PVV 119 Design and fabrication of metallic piping supports - Standard for
piping supports
GS EP PVV 202 Standard drawings for accessories and equipment vessels
GS EP PVV 211 Design and fabrication of pressure vessels according to ASME VIII
GS EP PVV 212 Design and fabrication of pressure vessels according to
BSI PD 5500
GS EP SPS 008 Thermal insulation of subsea stations

3. Insulation Classes
The specific insulation codes as provided below according to GS EP ICS 002 which is the
controlling document for specification of insulation codes.

Class C: Cold conservation


The purpose is to reduce heat gains according to values defined in the Job Specification (W/m2
on equipment and W/lm on piping).

Class K: Condensation prevention


The purpose is to prevent surface condensation due to ambient temperature and relative
humidity.
For other Insulation Classes (B, D, E, H, I, P, R, and S), refer to GS EP COR 771.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 8 of 65

For Class A (Acoustic insulation), Class L (Cold and acoustic) and Class T (Hot and acoustic),
refer to Particular Project Specification.

4. Insulation systems
Depending operating temperature, the insulation system shall be selected according the
following table:
Insulation
Operating Temperature Insulation System Comments
Class

-50°C to ambient 20 or 22 Or see paragraph 9.3.3 for a


C
spraying or pouring
K application method
-51°C to -180°C 21 or 23

Insulation systems are described in Appendix 1.

5. Fire resistance
Other requirements for fire performance in terms of heat generation, flame spread and smoke
development may apply depending on the facilities being assessed and local fire regulations
require to be specified e.g. BS 476-6, BS 476-7 may be specified for Northern Continental shelf
or IMO 2010 FTP Code for shipping or FPSO units.
Unless otherwise specified, materials shall, at least, meet the requirements of EN 13501-1,
Class A1.

6. General Design
6.1 General
All design shall allow for necessary room for insulation with protective jacketing and preformed
boxes. Particular care shall be taken in piping design to ensure sufficiently long straight pipe
runs around e.g. branches, nozzles, bends, valves, flanges and supports to enable proper
installation of insulation.

6.1 Insulation supports


Piping and equipment are supplied with insulation supports in accordance with the insulation
fabrication design documentation as per specification GS EP PVV 111, GS EP PVV 211 and/or
GS EP PVV 212 (depending which is applicable). Supports are supplied and installed by the
piping or vessel fabricator.

6.2 Piping supports


Piping is supplied with insulated supports according to specification GS EP PVV 119.

6.3 Insulation water-tightness


Particular attention shall be taken to warranty the complete water and vapour tightness of the
insulation and protective cladding. Penetration and insulation termination shall be perfectly
sealed according to paragraphs 9.8 and 9.9.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 9 of 65

6.4 Surface preparation


All surfaces to be insulated will be appropriately protected in accordance with GS EP COR 350.

6.5 Insulation type and thickness


Piping and equipment are insulated according to the insulation class, operating temperature and
insulation thickness defined in the Particular Project Specification, P&ID, line lists, and data
sheets or construction drawings.

6.6 Extent of insulation


The entire system is fully insulated, including all piping components, drains, piping/tubing of
instruments, nozzles and supports to the extent specified.
All metal parts which protrude through the insulation shall be insulated. The extent of insulation
is at least as noted below:
• Skirt supporting vertical equipment: inside and outside: four times the insulation thickness
from the bottom tangent line and not less than 300 mm
• Metal saddle supporting horizontal equipment: four times the insulation thickness from the
low point of the vessel shell or down to the supporting plate
• Structural steel member supporting equipment: three times the insulation thickness from
the outside surface of insulation, in each direction
• Vessel clips for pipe support, platform or ladder brackets: one time the insulation
thickness from the outside surface of insulation
• Pipe support trunnions: three times the insulation thickness from the outside surface of
insulation
• Vents, drains, instrument tubing: up to the first valve.
Saddles, skirts, steel member and trunnions shall be of sufficient length to allow a minimum of
300 mm of bare metal between termination of insulation and support/structure.
The insulation thickness for protruding parts are based upon the operating temperature of the
pipe or equipment and the size of the protrusion: diameter for cylindrical protrusion and longest
dimension rounded to the nearest pipe diameter for structural attachment.
The insulation thickness for fittings, valves and flanges are the same as for the adjoining pipe.
Name plates, coding tags, etc. are insulated. A duplicate name plate supplied by vessel
constructor shall be installed outside of the insulation system.
All metal attachments which are integral part of the vessel, such as stiffeners, are insulated with
two third of the nominal thickness where applied in multilayer, and full thickness where applied
as single layer.
Each line is insulated as a single unit. A minimum clearance of 50 mm shall be provided
between the outer surface of the insulation and any obstruction such as structural steel, piping
or other insulated line

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 10 of 65

At flanged joints, insulation is stopped at sufficient distance to allow the removal of studs without
damaging adjacent insulation. The clearance, at each side of the flanged joint, shall equal at
least the stud/bolt length plus 25 mm.
Piping supports are designed according to GS EP PVV 119 and to insulation type and
thickness. Final design shall be approved by Company Specialist.

7. Materials
Material specifications are given in Appendix 2.

7.1 General
• All materials shall be selected in accordance with the requirements specified within this
section and shall be new, undamaged and free from contamination.
• Medical, Safety and Product data sheets for all materials shall be approved by Company.
• Materials shall have the following general properties:
- on austenitic stainless steel, insulation materials shall comply with ASTM C795,
- full agreement certificates,
- completely free from asbestos,
- material shall not cause any harm or known hazard to health during application while in
use, or on removal,
- chemically neutral with pH preferably between 7 and 8 in wet conditions,
- water soluble chloride and fluoride as low as possible,
- non-combustible. Cladding materials at least self-extinguishing,
- not corrosive to metal surfaces and compatible with coating system applied,
- impervious to water and water vapour, and chemically inert,
- odourless at normal operating temperature.
Materials shall conform to the requirements of Material Specifications (Appendix 2).

7.2 Insulating materials

7.2.1 Cellular Glass (CG)


Cellular glass shall conform to the requirements of Material Data Sheet N°001.
Factory pre-fabricated and pre-coated pieces shall be used, except for special items or coating
not in the Manufacturer fabrication list. These items shall be insulated with pieces cut from pipe
sections or segment and perfectly fitted on site.
• Pipes sections or radiused and bevelled segments for straight parts.
• Two pieces (or more, according to size) preformed elbows, tees and reducers.
• Radiused and bevelled segments for equipment shells.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 11 of 65

• Spherical or elliptical segments for vessel head and bottoms.


• Trapezoidal segments for cones.
• Prefabricated flange and valve boxes.

7.2.2 Polyisocyanurate (PIR)


Rigid polyisocyanurate foam shall be blown without HCFC in accordance with European
Community regulations.
Polyisocyanurate shall conform to the requirements of Material Data Sheet N°009.
Factory pre-fabricated and pre-coated pieces shall be used, except for special items not in the
Manufacturer fabrication list. These items shall be insulated with pieces cut from pipe sections
or segment and perfectly fitted on site.
• Pipes sections or radiused and bevelled segments for straight parts.
• Two pieces (or more, according to size) preformed elbows, tees and reducers.
• Radiused and bevelled segments for equipment shells.
• Spherical or elliptical segments for vessel head and bottoms.
• Trapezoidal segments for cones.
• Prefabricated flange and valve boxes.

7.2.3 Mineral wool or Flexible Elastomeric Foam for contraction joint


Material for contraction joint shall be a flexible and resilient insulating material as mineral wool
or Flexible Elastomeric Foam, suitable with operating temperature.
Mineral wool shall only be used for contraction joint. It shall be a resilient low density loose rock
wool or glass wool with water soluble chloride and fluoride as low as possible (less than
10 mg/kg).
Mineral wool shall conform to the requirements of Material Data Sheet N°003.
Flexible Elastomeric Foam shall conform to the requirements of Material Data Sheet N°008.

7.3 Protective cladding

7.3.1 GRP laminated sheet (GRP)


The glass reinforced plastic shall be an UV curing laminated sheet or pre-cured cladding and
moulded accessories.
The preferred method is the application of pre-cured pipe sections and moulded pieces for
fittings as elbows, tees, reducers, end caps and vessel heads.
The minimum thickness of GRP shall be 2 mm ± 0.2 mm.
The GRP laminated sheet shall conform to the requirements of Material Data Sheet N°011 or
012.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 12 of 65

7.3.2 Coating mastic


Coating mastic is a tough, flexible and fire resistive elastomeric finish.
Coating mastic shall conform to the requirements of Material Data Sheet N°107.

7.3.3 Miscellaneous
All appurtenances and fixing shall be in AISI type 316L.

7.4 Insulation securement

7.4.1 Self-adhesive bands


Self-adhesive bands shall be a tape reinforced with continuous glass fibres in the longitudinal
direction along with a polypropylene backing (glass reinforced filament tape).
The self-adhesive bands shall conform to the requirements of Material Data Sheet N°109.

7.4.2 Stainless steel bands and seals


Stainless steel bands and seals shall be AISI type 316L, 0.5 mm thick, 13, 19 or 25 mm width.

7.5 Anti-abrasive coating, sealant, adhesive and vapour barrier

7.5.1 Anti-abrasive coating for cellular glass


Anti-abrasive coating shall be factory applied and used to prevent damage to cellular glass and
painting.
Operating temperature -50°C to ambient: low temperature anti-abrasive (LTAA) is a one-
component acrylic based coating.
Operating temperature -180°C to -51°C: high temperature anti-abrasive (HTAA) is of high
strength gypsum cement with inert mineral fillers.
The Anti-abrasive coatings shall conform to the requirements of Material Data Sheet N°100, 101
or 102.

7.5.2 Bonding adhesive


The bonding adhesive is a two components high strength thermosetting adhesive, remaining
flexible after curing.
The bonding adhesive shall conform to the requirements of Material Data Sheet N°105.

7.5.3 Cryogenic adhesive/coating for vapour stop


The cryogenic adhesive/coating is a two component elastomeric adhesive coating designed for
cryogenic application.
The cryogenic adhesive/coating shall conform to the requirements of Material Data Sheet
N°106.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 13 of 65

7.5.4 Joint sealant


The joint sealant is a non hardening butyl based sealer.
The joint sealant shall conform to the requirements of Material Data Sheet N°104.

7.5.5 GRP Adhesive


The GRP adhesive used to bond together GRP pre-moulded pieces is selected in accordance
with GRP manufacturer instructions.
The GRP adhesive shall conform to the requirements of Material Data Sheet N°013 or 014.

7.5.6 Reinforcing fabric


Reinforcing fabric is a polyester open mesh fabric.
The reinforcing fabric shall conform to the requirements of Material Data Sheet N°111 or 112.

7.5.7 Multiplex foil


The secondary vapour barrier is a three layers multiplex foil, consisting of a central layer of
25 microns thick aluminium foil sandwiched between two 12 microns thick polyester films.
The secondary vapour barrier shall conform to the requirements of Material Data Sheet N°114.

7.5.8 Aluminium-butyl Membrane


The aluminium-butyl membrane shall be an elastomeric modified butyl rubber, pressure
sensitive adhesive laminated with an aluminium/polyester/aluminium laminate foil.
The aluminium-butyl membrane shall conform to the requirements of Material Data Sheet
N°108.

7.5.9 Butyl rubber sheet


The cover over the outer insulation layer contraction joint shall be a poly-isobutylene sheet
(butyl rubber), 1 mm thick x 180 to 200 mm wide.
The butyl rubber sheet shall conform to the requirements of Material Data Sheet N°110.

7.6 Pipe supports


For cold insulated systems, PIR foam supports shall be specified for this application. The
specific selection of material shall take account of the required fire performance of the system
especially since high density PIR products have lower fire performance than low density PIR.
Supports shall be designed to withstand all service loads including thermal stresses as well as
all mechanical loads and clamping forces.
At support location, insulation material shall have a density higher than 160 kg/m3.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 14 of 65

8. General conditions for execution of works


8.1 Qualification requirements
• Operators, foremen and supervisor shall be individually certified by an approved
organization or by the product’s Manufacturer through the Applicator’s training system.
• Operators shall be individually qualified to tradesman level as “insulation applicator” or
“GRP applicator” and shall be familiar with the application of cellular glass and GRP.
• A register of qualified operators shall be documented (with photographic record). No
untrained or unsupervised personnel shall be used for insulation application.
• Supervisors and Foremen shall be qualified to tradesman level and shall have
documented minimum 3 years experience with insulation work described in this General
Specification.
• QC or personnel carrying out inspection or verification shall be qualified by the products
material suppliers, shall be familiar with the requirements in this General Specification,
and shall be accepted as inspector by the company.

8.2 Health, Safety and Environment


The Contractor shall take cognizance of the contents of the products safety data sheet and take
appropriate preventive measures and precautions to save personnel from injury, intoxication
and illness, in accordance with the project HSE plan.
The Contractor shall organize the management of waste in accordance with the project HSE
plan and the Rules in force.
Personnel shall have a relevant knowledge of health and safety hazard, use of individual
protection equipment, insulation systems surface requirements, and how to avoid corrosion
under insulation.

8.3 Material supply, handling and storage


• All materials shall be supplied in accordance with the material specifications of Appendix
2, with their Conformity Certificate.
• Materials shall be properly packed, handled, transported and stored in accordance with
the Manufacturer’s instructions.
• The materials shall remain in the original packaging, identified with manufacturer name,
product name, type, grade, density, thickness and dimensions. They shall be stored in dry
areas, sheltered from water and sun, and not in direct contact with the ground.
• Adhesives, coating mastics and sealants shall remain in the original packaging, identified
with manufacturer name, product name, type, batch number and expiry date. According to
Manufacturer instructions (minimum and maximum storage temperature), storage in air-
conditioned areas must be required.
• Factory or shop prefabricated elements shall be properly packaged by the
manufacturer in order to allow offshore transportation without damages: cardbox
shall be of strong and reinforced type, each element shall be individually wrapped and

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 15 of 65

voids shall be filled with air buffers. Packages shall be properly sealed and identified with
manufacturer name, product name, type, grade, density, thickness, dimensions and
Project name. They shall be carefully stored and handled to prevent any damage or
deformation.

8.4 Samples
Sample from each batch can be taken by the Company for conformance checking.

8.5 Preliminary conditions


An Inspection and Test Plan for the execution of the work shall have been approved by
Company or his representative.
The Applicator shall not commence any insulation works until a release report have been
officially issue, authorising insulation application.
Piping and equipment shall have all welding completed and shall have been hydrostatically or
pneumatically tested.
The thermal insulation supports shall have been installed according to the insulation fabrication
design documentation as per specification GS EP PVV 111, GS EP PVV 202, GS EP PVV 211
and/or GS EP PVV 212 (depending which is applicable).
The surfaces shall have been appropriately protected in accordance with GS EP COR 350 for
carbon steels and stainless steels.
The Contractor shall advise the Company or its representative of any remedial work that may be
required, in good time prior to commencement of insulation.

8.6 Pre-insulation
Manual or mechanical workshop pre-insulation on over-coated piping spool shall be
recommended whenever possible.

8.7 Execution conditions


The Applicator shall obtain technical assistance from the Manufacturers.
Just before fitting the thermal insulation, surfaces to be thermally insulated shall be:
• cleaned and dried,
• free of all oil, grease, loose scale and foreign matter,
• have been successfully hydrostatically tested,
• 100% holiday detected according GS EP COR 350 (no holidays) just before fitting the
thermal insulation.
Insulation shall only be fitted if the substrate temperature is at least 3°C above the dew point.
No work shall be carried out during period of rain or in a damp environment, except under
shelter and in a controlled atmosphere.
Application of the protective jacketing shall be done immediately after the installation of the
insulation. Insulation awaiting protective cladding shall be provided with effective temporary

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 16 of 65

weather and UV protection as polyethylene sheeting or tarpaulin. Insulation that has become
wet shall be removed and replaced with dry material.
The use of broken pieces of insulation for the filling of gaps or voids caused by incorrect fitting is
not permitted. Where such gaps or voids arise, the insulation shall be removed and refitted
correctly.

9. Application
9.1 Application Procedure
Insulating material and protective jacketing shall be applied according to an approved
Application Procedure, prepared by the Contractor according to the present specification and
Manufacturer application procedures.

9.2 Cellular Glass

9.2.1 General
Pipe sections, segments and prefabricated pieces shall be shaped to fit properly around the
pipes, fittings, shells and heads.
Insulation thicknesses up to 70 mm could be applied as single layer. For thicknesses above
70mm, insulation shall be applied as Multi-layer system.
In order to get rigid insulation system, longitudinal joints shall be staggered with an offset at
least equal to 150 mm.
When insulation is applied in two layers or more, the sections or segments shall be staggered
both radially and axially from the previous layer to the next one. Pipe sections shall be offset by
90° in successive layers and segments with an offset equivalent to half the segment width.
Application shall start by the installation of fittings insulation.
Pipe sections, segments and prefabricated pieces shall be tightly butted together and shall not
be bonded to the substrate.
Gaps or open joints resulting from damaged material or poor fit are not permitted (maximum gap
less than 1.5 mm).

9.2.2 Anti-abrasive coating


The anti-abrasive coating is a factory applied onto the inner side of the cellular glass elements
which will be in contact with the substrate.
The anti-abrasive coating shall be selected according to the operating temperature and
Insulation System.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 17 of 65

9.2.3 Contraction joints


In order to allow for differential linear contraction between metal and cellular glass, insulation
shall be provided with contraction joints.
• Operating temperature: -100°C to ambient: not necessary
• Operating temperature: -180°C to -101°C: contraction joint every 9 m.
A contraction joint consists of a 25 to 30 mm annular space in the insulation filled with resilient
low density mineral wool or flexible elastomeric foam. These joints shall be provided at each
layer with minimum 150 mm offset.
On vertical piping or equipment, contraction joint shall be placed directly beneath each support
ring.
The cover of the contraction joint shall be formed from flat butyl rubber sheet incorporating a
single 20 mm wide fold. The butyl rubber sheet shall be adhered with compatible adhesive with
the fold centrally positioned and shall be secured on both side with bands. The vapour barrier
shall overlap each side of the cover and bands.

9.3 Polyisocyanurate (PIR)

9.3.1 General
Pipe sections, segments and prefabricated pieces are shaped to fit properly around the pipes,
fittings, shells and heads.
For operating temperature below -50°C, a secondary vapour barrier foil shall be applied
between the outer insulation layer and the layer immediately beneath. Secondary vapour barrier
foil shall be preferably factory applied to the outer surface of the intermediate insulation layer or
shall be installed in the field prior to the installation of the outer insulation layer. The longitudinal
and circumferential joints in the secondary vapor barrier foil shall be sealed with multiplex foil
self adhesive tape.
Insulation thicknesses up to 50 mm could be applied as single layer and up to 80 mm with
longitudinal and circumferential ship-lapped joints.
In order to get rigid insulation system, longitudinal joints shall be staggered with an offset at
least equal to 75 mm.
When insulation is applied in two layers or more, the sections or segments shall be staggered
both radially and axially from the previous layer to the next one. Pipe sections shall be offset by
90° in successive layers and segments with an offset equivalent to half the segment width.
Application starts by the installation of fittings insulation.
Pipe sections, segments and prefabricated pieces are tightly butted together and shall not be
bonded to the substrate.
Gaps or open joints resulting from damaged material or poor fit are not permitted.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 18 of 65

9.3.2 Contraction joints


In order to allow for differential linear contraction between metal and polyisocyanurate,
insulation shall be provided with contraction joints.
• Operating temperature -50°C to ambient: not necessary.
• Operating temperature -200°C to -51°C: contraction joint every 6 m.
A contraction joint shall consist of a 30 to 50 mm annular space in the insulation filled with
resilient low density mineral wool or flexible elastomeric foam. These joints shall be provided at
each layer with minimum 150 mm offset.
On vertical piping or equipment, contraction joint shall be placed directly beneath each support
ring.
The cover of the contraction joint shall be formed from flat butyl rubber sheet incorporating a
single 20 mm wide fold. The butyl rubber sheet shall be adhered with compatible adhesive with
the fold centrally positioned and shall be secured on both side with bands. The vapour barrier
shall overlap each side of the cover and bands.

9.3.3 Pre-insulation application at shop by spraying or pouring method


Pre-insulation application may be done by sprayed or poured Polyisocyanurate in workshop.
Shop applied sprayed or poured Polyisocyanurate material shall be conformed to the
requirements of Material Data Sheet N°009.
Pre-insulation systems shall incorporate vapour barriers, all expansion and contraction
allowances and shear keys. A fully detailed specification including method, design, workshop
environment and means of movement of the spools shall be submitted to Company for
approval.

9.4 Bonding adhesive


For operating temperature from -50°C to ambient, adhesive may be used for full bonding of
insulation to particular part of equipment or piping in order to facilitate insulation application
(bottom head for example).

9.5 Joint sealing


Longitudinal and circumferential insulation joints shall be sealed with joint sealant.
For a multi-layer application, the first or initial layers shall be applied dry. Only longitudinal and
circumferential insulation joints of the uppermost layer shall be sealed with joint sealant.
Joint sealant shall be preferably gun extruded, in two Ø 7 mm minimum beads, with one bead at
outermost side of the joint height. Joint sealant shall be applied continuously without gap, with
continuity from longitudinal joints to circumferential joints, without gap. Any excess of sealant
squeezed out of the joint shall be cleaned up by a careful smoothing. Alternatively, the joint
sealant shall be applied in full depth of the uppermost layer thickness using a trowel or putty
knife.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 19 of 65

9.6 Insulation securement


Insulation pipe sections, segments and fittings shall be secured with filament tape with a 50%
overlap of the tape per wrap.
Minimum wide of filament tape according to diameter over insulation:
• OD up to 500 mm: 19 mm
• 500 mm < OD ≤ 1000 mm: 25 mm
• OD > 1000 mm: 50 mm.
Each layer of insulation shall be secured independently on every 300 mm, with a minimum of
two bands for each section, segment or piece. The tension shall be such that the insulation is
not damaged.
Insulation segments on bottom head and bottom under skirt shall be secured with stainless
steel band, tightened from inside skirt supporting ring or from shell banding, on at least every
300 mm.

9.7 Vapour barrier and lamination layer


An aluminium-butyl membrane shall be required on the uppermost insulation layer, before the
application of GRP cladding, as vapour barrier and in order to allow differential movements
between insulation and GRP and to avoid any cracks or tension into the GRP.
The aluminium-butyl membrane should be factory applied, particularly on elbows, tees, reducers
and bottom heads.
The longitudinal and circumferential joints in the vapour barrier shall be sealed with aluminium-
butyl bands, 50 mm wide, or shall overlap for 30 to 50 mm.

9.8 Vapour stop


Vapour stop shall be installed at all pipe support location: insulation shall be bonded to the
insulation material of the support and to the pipe surface for 150 mm with bonding adhesive or
cryogenic adhesive coating according to operating temperature.
Vapour stop shall be installed at each insulation termination at valve, flange, tee, etc.
• For operating temperature -50°C to ambient, vapour barrier membrane or two layers of
coating mastic reinforced with synthetic reinforcing fabric shall be dressed on the edge of
insulation and extended for 50 mm over the pipe surface and beneath the vapour barrier.
• For operating temperature -180°C to -51°C, insulation shall be bonded to the pipe surface
for 150 mm with cryogenic adhesive coating. The edge of insulation shall be dressed with
three layers of cryogenic adhesive coating reinforced with synthetic reinforcing fabric and
extended for 50 mm on the pipe surface and beneath the vapour barrier.

9.9 Penetration and protrusion


The insulation around penetrations and protrusions shall be treated as a vapour stop installed
as per paragraph 9.8, so that water cannot penetrate into the insulation system. Materials shall
be selected according to operating temperature.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 20 of 65

9.10 Insulation supports


Piping and equipment insulation supports are supplied and installed by the piping or vessel
fabricator (refer to paragraph 6.1).

9.11 Protective cladding - Glass Reinforced Polyester (GRP)

9.11.1 General
The preferred method is the application of pre-cured pipe sections and moulded pieces for
fittings as elbows, tees, reducers, end caps and vessel heads.
Pre-cured pipe sections and moulded pieces is supplied ex-factory or prefabricated in an
onshore site workshop.
UV curing GRP is only applied on site when prefabricated pieces cannot be used.
The GRP cladding shall be applied in accordance with the Manufacturer instructions by trained
and experienced personnel, certified by the Manufacturer (paragraph 8.1).
The GRP cladding shall be fully watertight.

9.11.2 Overlapping and bonding


Longitudinal joints shall be staggered.
Longitudinal and circumferential joints shall be positioned to shed water, and arranged with a
minimum overlap of 30 mm up to OD 300 mm and 50 mm for higher OD, for straight parts.
For moulded fittings, the minimum overlapping shall be:
• OD ≤ 199: 15 mm
• 200 ≤ OD ≤ 299: 25 mm
• 300 ≤ OD ≤ 399: 35 mm
• OD ≥ 400: 45 mm.
Overlap is properly prepared and bonded together with recommended adhesive. The quantity of
adhesive shall be sufficient to ensure perfect tightness. The excess of adhesive extruded during
tightening shall be cleaned out by a careful smoothing.
During curing time of GRP adhesive, overlaps shall be firmly strapped with appropriate devices.

9.11.3 Vessel and equipment


Appropriate GRP grade and application method are defined or agreed by the GRP
Manufacturer, according to specific data of each vessel and equipment.
According to the vessel design and size, the GRP cladding shall be reinforced by 316L stainless
steel 19 x 0.5 mm supporting bands, equally spaced, and incorporated in the cladding by a
bonded GRP backing strip.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 21 of 65

9.11.4 Terminations, penetration and protrusion


At terminations and around penetrations and protrusions, the GRP cladding shall be treated so
that water cannot penetrate into the insulation system.
Pre-moulded GRP end cap, or UV curing GRP applied on site, will be used.

9.11.5 Contraction joints


In order to allow for differential linear contraction between metal, insulation and cladding, GRP
cladding shall be provided with contraction joints.
Contraction joints shall be placed closely to the insulation contraction joints, if any.
These shall be placed, prepared and installed in accordance with Manufacturer instructions.

9.12 Mastic vapour barrier and weatherproofing


For particular application, bottom under skirt for example, coating mastic shall be applied as
vapour barrier and weatherproofing. Application of the vapour barrier shall immediately follow
installation of the insulation.
Vapour barrier shall be applied in strict accordance with the SUPPLIER’s application
instructions and shall comprise at least two layers of coating mastic, reinforced with a layer of
reinforcing fabric.

9.13 Valves, flanges and removable parts


Insulation for valves, flanges and removable parts shall be equal in thickness and type to that
applied on adjacent pipe or equipment. The insulation shall be preformed or fabricated in single-
matched halves to the maximum extent possible.
The insulation shall overlap the adjacent insulation and shall be applied with the same
procedure.
The entire outer surface of insulation shall be sealed with vapour barrier membrane with 50 mm
overlapping.
Shop fabricated GRP boxes or UV curing GRP are applied over the insulation.
Overlap is properly prepared and bonded together with recommended adhesive. The quantity of
adhesive shall be sufficient to ensure perfect tightness. The excess of adhesive extruded during
tightening shall be cleaned out by a careful smoothing.
During curing time of GRP adhesive, overlaps shall be firmly strapped with appropriate devices.

9.14 Repairs
Execution defects shall be drawn to the Company attention through the Quality Assurance Plan
and the method of repair shall be submitted to Company agreement.

9.14.1 Minor defect


Minor defects shall be treated according to Manufacturer instructions.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 22 of 65

The final aspect of GRP cladding applied in situ may present some slight imperfection as
wrinkle, ripple or emboss after curing. These shall not exceed 2 mm and should be abraded.
Filler compound shall also be used for small repairs.

9.14.2 Major defect


The extent of the defect shall be subject to Company agreement.
The elements shall be fully removed and replaced by new materials after cleaning and checking
of the substrate.

10. Tests, inspections and acceptance


10.1 Tests
Applicator shall check the following points, in accordance with the systems selected. The results
of these checks shall be recorded in the control sheets.
• Compliance with specifications
• Compliance with fire testing specifications for combustible materials
• Conformity of thermal insulation supports and welded collars
• Condition of surfaces to which the thermal insulation is applied
• Climatic conditions of application
• Surface temperatures
• Quality of materials (compliance with specifications)
• Thickness and number of layers
• Quality of implementation (maximum gap between segments, etc.)
• Check of location of contraction joint
• Effectiveness of fixings and clamping elements
• Quality of prefabrication of protective cladding components
• Compression of cladding on equipment and piping
• Fixing of cladding components to each other, overlaps
• Finishing
• Water tightness of insulation
• Quality and water tightness of the termination seals
• Quality and strength of removable boxes (assembly/dismantling).

10.2 Inspection
As part of the Quality Plan, an Inspection and Test Plan (ITP) including all points indicated in
paragraph 10.1 shall be prepared and submitted to Company who shall indicate the insulation

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 23 of 65

operations to be reviewed or witnessed in the various phases of execution and inspection of the
work.

10.3 Acceptance

10.3.1 Quality control


During acceptance testing by nominated party, a check shall be run to ensure that all the
inspections listed in paragraph 10 (tests) shall carry out and that the results are satisfactory.
Particularly emphasis shall be made with respect to inspection of jacket seals at penetrations
and terminations and insulation overlaps to ensure natural water shedding is achieved.

10.3.2 Thermal efficiency


After start-up of the installation, the following checks may be carried out on Company request, in
accordance with the Contract requirements:
• Surface temperature
• Heat gains.
Infrared cameras or other appropriate devices shall be used, according to the Company
requirements (measurement locations and numbers, duration, etc.).
The results of the tests shall be recorded in a report.
A second check shall be carried out before the end of the warranty period.
Acceptance test operations shall be recorded in a report.
The Applicator shall guarantee that the insulation has been executed in strict compliance with
this specification. Compliance shall be established through insulation thickness tables.

11. Technical documentation


11.1 Bid stage
Tenders shall include the following data:
• Contractor company profile
• Company quality system or manual (ISO 9000 or equal)
• Experience of similar projects and reference list
• List of subcontractors
• List of materials to be used with selected manufacturer and vendor
• List of deviations or exceptions
• Scope of work and method statement (outline)
• Key personnel and experiences
• Material storage and control policy
• HSE policy.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 24 of 65

11.2 Prior to work commencement


Contractor shall supply the following documents and data before work commencement:
• Detailed Application Procedure based on the present specification, the project
requirements and the Manufacturer application procedures, with detailed sketches and
processing for all particular points
• Repair procedures
• A quality assurance plan (QAP), including Inspection and Test Plan (ITP) and in particular:
- A nominal functional organisation chart
- The presence of an specialised inspector
- The list of installation and inspection phases, and their associated procedures
- List of installation and inspection equipment
- Resources provided for protection against adverse climatic conditions.
• List of materials with selected manufacturer and vendor, technical and safety data sheets,
test certificates
• Detailed scope of work including a List of insulated equipment and piping with operating
temperature, insulation type and thickness, detailed measurements and quantity.

11.3 At work completion


The technical documentation submitted by the Contractor on completion of the work shall
include:
• Handover (or release) certificate duly signed
• Quality control plans with inspection forms or certificates
• Acceptance report
• Maintenance program
• Data book containing:
- Certificates of conformity of materials
- Certificates of manufacture of the thermal insulation materials
- Certificates connected with tests and inspections by approved laboratories
- Certificates of fire performance as required by this specification
- Detailed execution standards
- Miscellaneous inspection forms
- Reports of tests and checks on thermal efficiency and effectiveness
- Acceptance test report.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 25 of 65

Appendix 1

Appendix 1 Description of insulation systems

Note: Identification principle


• Systems: from 20 to 23: see Appendix 1
• Insulating materials: from 001 to 009: see Appendix 2
• Cladding materials: from 011 to 014: see Appendix 2
• Miscellaneous: from 100 to 114: see Appendix 2
• Principle sketches: from 301 to 311: see Appendix 3

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 26 of 65

Appendix 1

SYSTEM 20
OPERATING TEMPERATURE: -50°C to ambient
COMPONENT DESCRIPTION REF REQUIREMENTS COMMENTS
Single layer of Inner face coated with LTAA anti-abrasive Insulation thickness
cellular glass coating N°101/102 ≤ 70 mm
Multi layer of Inner face of the first layer coated with Insulation thickness >
cellular glass LTAA anti-abrasive coating N°101/102 70 mm
INSULATION 001
Pipe sections
Pipe and equipment shell
or segments LTAA shall be factory
Preformed applied
Elbow, tee, cone, head…
pieces
All longitudinal and circumferential cellular Gun extruded and
INSULATION glass joints of the uppermost layer applied continuously in
Joint sealant 104
JOINT SEALING (For double layer application, the first layer two Ø 7 mm beads or
is applied dry) full depth with a trowel

OD up to 500 mm: 19 mm wide placed on 300 mm


centers, two bands
Filament tape 109 500 < OD ≤ 1000 mm: 25 mm wide
INSULATION minimum per section
SECUREMENT OD > 1000 mm: 50 mm wide or piece of each layer

Stainless Steel When required, on


13 x 0.5 or 19 x 0.5 mm
bands equipment
Should be factory
VAPOUR Alu-butyl
108 Applied on external face of cellular glass applied, particularly for
BARRIER membrane
pre-fabricated fittings
Bonding
105 Insulation bonding at supports and stops
adhesive
107 + Two layers reinforced
VAPOUR STOP Coating mastic
112 with synt.fabric
On insulation edges at terminations
or vapour
108
barrier
For pipe and
Pre-cured sections
equipment shell
Glass
For fittings as elbows,
Reinforced
CLADDING 011/012 Pre-cured moulded pieces tees, reducers, bottom
Polyester
heads, end caps…
(GRP)
For special pieces
U.V. curing
cladded on site
OD ≤ 300 mm: overlap
30 mm mini
GRP Adhesive 013/014 Bonding and sealing of overlapping
CLADDING OD > 300 mm: overlap
SECUREMENT 50 mm mini
316L Stainless When required, on
19 x 0.5 mm with GRP backing strip
Steel bands equipment
GRP End caps
CLADDING Moulded pieces and/or UV curing GRP
+ GRP 013/014
SEALING applied on site
Adhesive

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 27 of 65

Appendix 1

SYSTEM 21
OPERATING TEMPERATURE: -180°C to -51°C
COMPONENT DESCRIPTION REF REQUIREMENTS COMMENTS
Multi layer of Inner face of the first layer coated with
Two layers minimum
cellular glass HTAA anti-abrasive coating N°100
Pipe sections
INSULATION 001 Pipe and equipment shell
or segments HTAA shall be factory
Preformed applied
Elbow, tee, cone, head…
pieces

All longitudinal and circumferential


Gun extruded and
cellular glass joints of the uppermost
INSULATION applied continuously in
Joint sealant 104 layer
JOINT SEALING two Ø 7 mm beads or
(for double or multiple layer application,
full depth with a trowel
the first layers are applied dry)

OD up to 500 mm: 19 mm wide placed on 300 mm


500 < OD ≤ 1000 mm: 25 mm wide centers, two bands
Filament tape 109
INSULATION minimum per section
SECUREMENT OD > 1000 mm: 50 mm wide or piece of each layer
Stainless Steel When required, on
13 x 0.4 or 19 x 0.4 mm
bands equipment
Mineral wool/or
CONTRACTION Flexible 003/008 See paragraph 9.3.2
JOINT Elastomeric
Foam
Should be factory
VAPOUR Alu-butyl
108 Applied on external face of cellular glass applied, particularly for
BARRIER membrane
pre-fabricated fittings

106 Insulation bonding at supports and stops


Cryogenic
VAPOUR STOP adhesive Three layers
coating 106+111 On insulation edges at terminations reinforced with
synthetic fabric
For pipe and
Pre-cured sections
equipment shell
Glass
For fittings as elbows,
Reinforced
CLADDING 011/012 Pre-cured moulded pieces tees, reducers, bottom
Polyester
heads, end caps…
(GRP)
For special pieces
U.V. curing
cladded on site
OD ≤ 300 mm: overlap
30 mm mini
GRP Adhesive 013/014 Bonding and sealing of overlapping
CLADDING OD > 300 mm: overlap
SECUREMENT 50 mm mini
316L Stainless When required, on
19 x 0.5 mm with GRP backing strip
Steel bands equipment
GRP End caps
CLADDING Moulded pieces and/or UV curing GRP
+ GRP 013/014
SEALING applied on site
Adhesive

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 28 of 65

Appendix 1

SYSTEM 22
OPERATING TEMPERATURE: -50°C to ambient
COMPONENT DESCRIPTION REF REQUIREMENTS COMMENTS
≤ 80 mm with
Single layer of longitudinal and
Insulation thickness ≤ 50 mm
polyisocyanurate circumferential ship-
lapped joints

INSULATION Multi layer of 007 Insulation thickness > 50 or 80 mm


polyisocyanurate
Pipe sections or
Pipe and equipment shell
segments
Preformed pieces Elbow, tee, cone, head…
All longitudinal and circumferential
Gun extruded and
INSULATION polyisocyanurate joints of the
applied continuously in
JOINT Joint sealant 104 uppermost layer
two Ø 7 mm beads or
SEALING (for double layer application, the first
full depth with a trowel
layer is applied dry)
OD up to 500 mm: 19 mm wide placed on 300 mm
centers, two bands
Filament tape 109 500 < OD ≤ 1000 mm: 25 mm wide
INSULATION minimum per section
SECUREMENT OD > 1000 mm: 50 mm wide or piece of each layer

Stainless Steel When required, on


13 x 0.5 or 19 x 0.5 mm
bands equipment
Should be factory
VAPOUR Applied on external face of
Alu-butyl membrane 108 applied, particularly for
BARRIER polyisocyanurate
pre-fabricated fittings
Insulation bonding at supports and
Bonding adhesive 105
stops
VAPOUR
107 + Two layers reinforced
STOP Coating mastic
112 On insulation edges at terminations with synt.fabric
or vapour barrier 108
For pipe and
Pre-cured sections
equipment shell
For fittings as elbows,
Glass Reinforced
CLADDING 011/012 Pre-cured moulded pieces tees, reducers, bottom
Polyester (GRP)
heads, end caps…
For special pieces
U.V. curing
cladded on site
OD ≤ 300 mm: overlap
30 mm mini
GRP Adhesive 013/014 Bonding and sealing of overlapping
CLADDING OD > 300 mm: overlap
SECUREMENT 50 mm mini
316L Stainless Steel When required, on
19 x 0.5 mm with GRP backing strip
bands equipment
CLADDING GRP End caps + Moulded pieces and/or UV curing GRP
013/014
SEALING GRP Adhesive applied on site

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 29 of 65

Appendix 1

SYSTEM 23
OPERATING TEMPERATURE: -180°C to -51°C
COMPONENT DESCRIPTION REF REQUIREMENTS COMMENTS
Multi layer of
Two layers minimum
polyisocyanurate
INSULATION Pipe sections or 007
Pipe and equipment shell
segments
Preformed pieces Elbow, tee, cone, head…
Preferably factory
applied. Longitudinal
SECONDARY Applied on external face of insulation
Multiplex alu- and circumferential
VAPOUR 114 layer immediatly beneath the outer
polyester foil joints sealed with
BARRIER insulation layer
multiplex adhesive
tape
All longitudinal and circumferential
Gun extruded and
polyisocyanurate joints of the uppermost
INSULATION applied continuously in
Joint sealant 104 layer
JOINT SEALING two Ø7mm beads or
(for double or multiple layers application,
full depth with a trowel
the first layers are applied dry)
OD up to 500 mm: 19 mm wide placed on 300 mm
centers, two bands
Filament tape 109 500 < OD ≤ 1000 mm: 25 mm wide
INSULATION minimum per section
SECUREMENT OD > 1000 mm: 50 mm wide or piece of each layer

Stainless Steel When required, on


13 x 0.5 or 19 x 0.5 mm
bands equipment
Mineral wool
or
CONTRACTION
Flexible 003/008 See paragraph 9.3.2
JOINT
Elastomeric
Foam
Should be factory
VAPOUR Alu-butyl Applied on external face of
108 applied, particularly for
BARRIER membrane polyisocyanurate
pre-fabricated fittings
106 Insulation bonding at supports and stops
Cryogenic Three layers
VAPOUR STOP 106 +
adhesive coating On insulation edges at terminations reinforced with
111
synthetic fabric
For pipe and
Pre-cured sections
equipment shell
For fittings as elbows,
Glass Reinforced
CLADDING 011/012 Pre-cured moulded pieces tees, reducers, bottom
Polyester (GRP)
heads, end caps…
For special pieces
U.V. curing
cladded on site

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 30 of 65

Appendix 1

SYSTEM 23
OPERATING TEMPERATURE: -180°C to -51°C
COMPONENT DESCRIPTION REF REQUIREMENTS COMMENTS
OD ≤ 300 mm: overlap
30 mm mini
GRP Adhesive 013/014 Bonding and sealing of overlapping
CLADDING OD > 300 mm: overlap
SECUREMENT 50 mm mini
316L Stainless When required, on
19 x 0.5 mm with GRP backing strip
Steel bands equipment
CLADDING GRP End caps + Moulded pieces and/or UV curing GRP
013/014
SEALING GRP Adhesive applied on site

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 31 of 65

Appendix 2

Appendix 2 Material specifications

MATERIAL FORM DATA SHEET N°


Slabs, blocks, pipe sections, segments and preformed
Cellular Glass 001
pieces for elbows, tees, reducers and bottom head
Mineral wool for contraction joints Loose fill 003
Flexible Elastomeric Foam Sheets, panels, tubes 008
Rigid Polyisocyanurate foam for Slabs, blocks, pipe sections, segments and preformed
009
contraction joints pieces for elbows, tees, reducers and bottom head
UV curing laminated sheet or in pre-cured pipe sections
Glass reinforced polyester (GRP) FTI
and moulded accessories as elbows, tees, reducers, end 011
systems
caps, valve and flanges boxes, etc.
UV curing laminated sheet or in pre-cured pipe sections
Glass reinforced polyester (GRP)
and moulded accessories as elbows, tees, reducers, end 012
SolarTech systems
caps, valve and flanges boxes, etc.
Drum or cartridge 013
Adhesive for GRP
Drum or cartridge 014
High temperature anti-abrasive Powder 100
Drum 101
Low temperature anti-abrasive
Drum 102
Insulation joint sealant Drum 104
Insulation bonding adhesive Drum 105
Cryogenic adhesive & coating Drum 106
Coating mastic Drum 107
Aluminium-Butyl membrane Rolls 108
Self adhesive bands Rolls 109
Butyl Rubber sheet Rolls 110
Rolls 111
Reinforcing fabric
Rolls 112
Multiplex foil and self adhesive band Rolls 114
Stainless Steel Bands and seals 316 L: 13, 19, 25 x 0.5 mm thick with "wing" type seals

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 32 of 65

Appendix 2

Material specifications N°001


Form: slabs, blocks, pipe sections, segments and preformed
EXPANDED CELLULAR GLASS
pieces for elbows, tees, reducers and bottom head

Documents
Properties Min/max values Remarks
Reference
Expanded cellular glass without binder with
Product ASTM C552
homogeneous closed cell structure
FOAMGLAS® ONE or equivalent approved by
General specification
Company
Closed cell content ASTM D6226 100%
Apparent density ASTM C303 115 kg/m3
Service temperature limits NA -196°C to +430°C
Tm °C W/mK max.
Slabs Sections
-180 0.020 0.022
-150 0.022 0.024
-100 0.027 0.029
Tm °C = mean
Thermal conductivity ASTM C177 -50 0.035 0.036 temperature
0 0.040 0.043
+50 0.048 0.052
+100 0.057 0.062
+200 0.079 0.086
+300 0.103 0.110
Flame spread index ASTM E84 0 See section 4.1
Reaction to fire EN 13501-1 Euroclass A1
ASTM E96
Water vapour permeability max. 0 ng/(Pa.s.m) at 23° and 50% RH
Procedure A
Water absorption ASTM C240 None, apart from temporary surface retention
25 to 300°C: max 9 x 10-6m/(m.K)
Coefficient of linear expansion ASTM E228
-170 to 25°C: max 7 x 10-6m/(m.K)
Dimensional stability ASTM D2126 DiI,b ≤ 0.5; Δεd ≤ 1
Compressive strength ASTM C165 Mini 500 kPa in all directions
Compressive creep EN 1606 CC (1.5/1/50) ≥ 225 kPa
ASTM C240 /
Flexural strength 480 kPa
ASTM C203
Ph value ASTM C871 Between 7.00 and 10.5
Leachable chloride ASTM C871 10 ppm maximum
Prod data sheet All common acids except Hydrofluoric acid and
Resistance to chemical agents
ASTM C871 strongly Alkaline solutions

NOTE: If the temperature difference across the two sides of a single layer of cellular glass is more than 120K or if the
speed of temperature rise is > 2K/min, cracking may occur as a result of thermal stresses. In such cases, multi-layer
system shall be applied.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 33 of 65

Appendix 2

Material specifications N°003


MINERAL WOOL FOR CONTRACTION JOINTS Form: loose fill with no additives

Documents
Properties Min/max values or Requirements
Reference

Loose rock wool with diabase or basalt rock as principal raw


Product ASTM C764
materials

Apparent density According to the stuffing (100 to 200 kg/m3)

Service temperature limits Prod data sheet -200°C


Tm °C W/mK max.

20 0.040

- 20 0.033 Tm C = mean
Thermal conductivity ASTM C177
- 60 0.027 temperature

- 100 0.022

-140 0.018

Shot content ASTM C612 None

EN 13501-1 Non combustible A1


Combustibility
ASTM E84 Flame spread index: 0
Water absorption AGI Q136 ≤ 10% volume
Leachable chlorides content ASTM C871 ≤ 10 mg/kg
Ph value ASTM C871 Between 6.00 and 10.50 maximum
Resistance to chemical agents ASTM C871 Imputrescible

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 34 of 65

Appendix 2

Material specifications N°008


FLEXIBLE ELASTOMERIC FOAM (FEF) FOR
Form: sheets, panels, tubes
CONTRACTION JOINTS

Documents
Properties Min/max values or Requirements
Reference

Product ASTM C534 Synthetic rubber


Apparent density ASTM D1622 70 kg/m3 ± 15%
Percentage of closed cells ASTM D6226 90%
Service temperature limits -40°C to +105°C
Tm °C Max W/m.K

-20 0.034

-10 0.035 Tm C = mean


Thermal conductivity ASTM C177
0 0.036 temperature °C

10 0.037

20 0.037

ASTM E96
Water vapour permeability max. 0.007 g/(m².h) at 23°C and 50% RH
Proc A

Coefficient of linear expansion ASTM C534 7%


Compressive strength Prod data sheet 14 to 35 kN/m² at 25% deformation
Leachable chlorides content ASTM C871 ≤ 50 mg/kg
Ph value ASTM C871 Between 6.00 and 8.00 maximum
Fire performance ASTM E84 < 25

NOTE: Armaflex AF, K-Flex ST, or equivalent approved by Company.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 35 of 65

Appendix 2

Material specifications N°009


Form: slabs, blocks, pipe sections, segments and preformed
RIGID POLYISOCYANURATE FOAM
pieces for elbows, tees, reducers and bottom head

Documents
Properties Min/max values Remarks
Reference

Polyisocyanurate foam blown


Product
without HCFC

Apparent density ASTM D1622 ≥ 40 kg/m3

ASTM D6226
Closed cell content > 95%
Proc 2

Service temperature limits Prod data sheet -200°C to +120°C

Tm °C Max W/m.K

-170 0.016
-120 0.019

Thermal conductivity -80 0.022


ASTM C177 Tm C = mean temperature °C
-40 0.025
-20 0.024
0 0.024
20 0.027

Flame spread index ASTM E84 < 25

DIN 4102-1 B2
Reaction to fire
BS 476-7 Class 1

ASTM E96 max. 5.5 ng/(Pa.s.n) at 23°C


Water vapour permeability
Proc A and 50% R.H.

ASTM D2842
Water absorption ≤ 5% by volume
Proc B

Linear thermal expansion coefficient ASTM D696 max. 70.10-6 m/(m.K)


E-modulus ASTM D1623 at -165°C: max 16 MPa in all directions
Poisson's ratio ASTM D1623 0.4 at minimum temperature

at 23°C: 200 kPa


Compressive strength ASTM D1621 in all directions
at -165°C: 280 kPa

at 23°C: 300 kPa


Tensile strength ASTM D1623 in all directions
at -165°C: 200 kPa

Cryogenic thermal stress resistance


≥ 1.5 -165°C
ratio (CTSR)

Leachable chlorides content ASTM C871 ≤ 50 mg/kg


Ph value ASTM C871 Between 5.50 and 7.00 maximum

NOTE: TAREC PIR CR45 from Kinspan Tarec, CORAFOAM PB 45 from Duna Corradini, SAITEC, or equivalent.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 36 of 65

Appendix 2

Material specifications N°011


Form: UV curing laminated sheet delivered in 0.6 to 1.0 m
wide x 10 m long rolls or in pre-cured pipe sections and
GLASS REINFORCED POLYESTER (GRP)
moulded accessories as elbows, tees, reducers, end caps,
valve and flanges boxes, etc.

Documents
Properties Min/max values Remarks
Reference

F T I glass reinforced plastic UV curing laminated sheet and pre-


Product
cured cladding and moulded accessories

Isophthalic Polyester resin reinforced with shopped glass fibers


Construction
and surfacing tissue

Ultra Violet, natural or UV lamp (wave length 365 to 420 mm) at


Curing mechanism Prod data sheet
-15 to +70°C

Apparent density Prod data sheet 1.5 g/cm³


Thickness Prod data sheet 2 mm ± 0.2
Tensile strength ASTM D3039 71 MPa
Service temperature limit Prod data sheet 90°C Fibaclad VEFR: 135°C
Flexural strength ASTM D790 > 130 MPa
Elongation at break ASTM D3039 1.25%
Compressive strength ASTM D695 138 MPa
Impact resistance ASTM D256 70 kJ/m²
Hardness ASTM D2583 > 60 Barcol
Adhesion to steel ASTM D4541 > 14 MPa
Permeability ASTM E96 0.012 g/m².h.mmHg
Colour Prod data sheet Off white or grey
Heat distortion ASTM D648 > 255°C
Flame spread index BS 476-7 Class 1
Flame spread index ASTM E84 15/50

12 months in closed original


Storage Prod data sheet dry, < 25°C packing as per manufacturer
instructions

NOTE: FTI Fibaroll/Fibaclad - Refer to Manufacturer application procedure.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 37 of 65

Appendix 2

Material specifications N°012


Form: UV curing laminated sheet delivered in 0.92 m wide x
10 m long rolls or in pre-cured pipe sections and moulded
GLASS REINFORCED POLYESTER (GRP)
accessories as elbows, tees, reducers, end caps, valve and
flanges boxes, etc.

Documents
Properties Min/max values Remarks
Reference

SOLARTECH glass reinforced plastic UV curing laminated sheet


Product
and pre-cured cladding and moulded accessories

High grade Isophthalic Polyester resins fillers and glass


Construction
reinforcements

Curing mechanism Prod data sheet Ultra Violet, natural or UV lamp


Weight Prod data sheet 1.5 g/cm³
Thickness Prod data sheet 2 mm ± 0.2
Tensile strength BS 2782-0 55 MPa
Service temperature limit Prod data sheet dry: 120°C wet: 90°C
Flexural strength ASTM D790 > 130 MPa
Elongation at break BS 2782-0 > 3% SolarClad / SolarTech
Compressive strength ASTM D695 > 200 MPa SolarClad / SolarTech
Impact resistance ASTM D256 > 60 kJ/m² SolarClad / SolarTech
Hardness ASTM D2583 > 60 Barcol
Adhesion to steel ASTM D4541 > 14 MPa
Permeability ASTM E96 0.012 g/m².h.mmHg
Colour Prod data sheet grey
Heat distorsion ASTM D648 > 145°C SolarClad / SolarTech
Flame spread index BS 476-7 Class 1

12 months in closed original


Storage Prod data sheet dry, < 25°C packing as per manufacturer
instructions

NOTE: SolarTech SolarClad/ PE55 - Refer to Manufacturer application procedure.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 38 of 65

Appendix 2

Material specifications N°013


ADHESIVE for Glass Reinforced Polyester Form: drum or cartridge

Documents
Properties Min/max values Remarks
Reference

FibaBond 2K: two component adhesive based on silane


Prod data sheet
Product modified polmers

Prod data sheet FibaBond HT: two component alkoxy cure silicone

Solvent Prod data sheet Free from solvents and isocyanates

Prod data sheet 1.35 g/cm³ FibaBond 2K


Apparent density
Prod data sheet 1.43 g/cm³ FibaBond HT

ISO 37 (at 23°C) 3 MPa FibaBond 2K


Tensile strength
ISO 527-3 1.28 MPa FibaBond HT

(short exposure: +120°C - 1h


Prod data sheet -40 to +100°C
max.) FibaBond 2K
Service temperature limit
(short exposure: + 220°C - 1h
Prod data sheet -40 to +180°C
max.) FibaBond HT

Cure temperature Prod data sheet -5 to +50°C

(90% of cure in 24 hours)


Prod data sheet 1.5 to 3 hours
FibaBond 2K
Curing time
(fixture time: 12 hours) -
Prod data sheet skin over time: 12 min.
FibaBond HT

ISO 37 (200 mm/min) 150% FibaBond 2K


Elongation at break
ISO 527-3 230% FibaBond HT

Prod data sheet 1: 1 FibaBond 2K


Mixing ratio
Prod data sheet 2: 1 FibaBond HT

Prod data sheet 20 minutes @ 23°C FibaBond 2K


Pot life
Prod data sheet 5 minutes @ 25°C FibaBond HT

Prod data sheet white FibaBond 2K


Colour
Prod data sheet black FibaBond HT

9 months in original
Prod data sheet 10 to 25°C unopened package -
FibaBond 2K
Storage
12 months in original
Prod data sheet 8 to 21°C unopened package -
FibaBond HT

NOTE: FTI Fibabond - Refer to Manufacturer application procedure.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 39 of 65

Appendix 2

Material specifications N°014


ADHESIVE for Glass Reinforced Polyester Form: drum or cartridge

Documents
Properties Min/max values Remarks
Reference

Product Prod data sheet elastomeric polymer adhesive based on Silyl modified polymer
Apparent density Prod data sheet 1.4 g/cm³ SolarBond
Tensile strength ISO 37 (100%) ± 1.7 MPa
Tensile strength at break ISO 37 ± 2.6 MPa
Elongation at break ISO 37 250%

(short exposure: +180°C - 1/2 h


Service temperature limit Prod data sheet -40 to +120°C
max.)

Application temperature Prod data sheet +5 to +35°C


Mixing ratio Prod data sheet one component
Open time Prod data sheet 15 minutes @ 20°C
Colour Prod data sheet white, grey other colours available

12 months in original unopened


Storage Prod data sheet 5 to 30°C
container (cartridge: 18 months)

NOTE: SolarBond from SolaTech - Refer to Manufacturer application procedure.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 40 of 65

Appendix 2

Material specifications N°100


HIGH TEMPERATURE ANTI-ABRASIVE COATING Form: powder delivered in polyethylene lined paper bags

Documents
Properties Min/max values Remarks
Reference

Product Gypsum cement with inert fillers

0.70 kg/dm3 Powder


Apparent density Prod data sheet
3
1.0 kg/dm Applied bore coating

Service temperature limits Prod data sheet -180°C to +350°C


Application temperature Prod data sheet +5 to +40°C
Working time at +25°C Prod data sheet about 30 minutes
Vicat setting time at +20°C Prod data sheet between 60 to 120 minutes
Complete drying (dry weather) Prod data sheet about 24 hours

Should not be used as vapour


Water vapour diffusion resistance Prod data sheet µ < 30
barrier

Colour Prod data sheet dark grey


Fire resistance Prod data sheet non-combustible
Mixing ratio Prod data sheet water = 6.5 to 7.5 kg for 10 kg powder

NOTE: Pittsburgh Corning HTAA or equivalent.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 41 of 65

Appendix 2

Material specifications N°101


LOW TEMPERATURE ANTI-ABRASIVE COATING Form: drum

Documents
Properties Min/max values Remarks
Reference

Product one-component acrylic based coating, for factory application


Apparent density Prod data sheet 0.9 kg/dm3
Solids (non-volatile) Prod data sheet 50% by weight
Service temperature limits Prod data sheet -180°C to +120°C
Application temperature Prod data sheet +5°C minimum
Drying Prod data sheet 2 to 3 hours at 20°C 10 minutes at 105°C
Colour Prod data sheet yellow
Fire resistance Prod data sheet combustible
Solvent Prod data sheet White spirit
Flash point Prod data sheet minimum +39°C
Coverage range Prod data sheet 0.40 kg/m² approx

shelf life: 2 years in original


Storage Prod data sheet from 0 to +45°C
unopened container

NOTE: Pittsburgh Corning LTAA compound 2A or equivalent.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 42 of 65

Appendix 2

Material specifications N°102


LOW TEMPERATURE ANTI-ABRASIVE COATING Form: drum

Documents
Properties Min/max values Remarks
Reference

Product one-component water based fire resistive coating


Apparent density ASTM D1475 1.6 kg/dm3
Solids (non-volatile) ASTM D2369 69% by weight (51% by volume)
Service temperature limits Prod data sheet -196°C to +93°C
Application temperature Prod data sheet Between +4 to +38°C
Drying ASTM D1640 2 to 3 hours at 23°C Set to touch: 45 to 90 minutes
Colour Prod data sheet Off white

Flame Spread: 10 Tested at 1.72 m²/l coverage


Fire resistance ASTM E84
Smoke Developed: 10 rate

Storage Prod data sheet Between +4 to +38°C Protect from freezing


Flash point ASTM D93 over +100°C
Coverage range Prod data sheet 0.3 to 0.4 kg/m² approx 0.28 to 0.41 mm wet thickness

NOTE: FOSTER 30-16 WB or equivalent.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 43 of 65

Appendix 2

Material specifications N°104


INSULATION JOINT SEALANT Form: drum or cartridge

Documents
Properties Min/max values Remarks
Reference

Product one-component, non hardening, butyl based sealer


Apparent density Prod data sheet 1.5 kg/dm3
Solids (non-volatile) Prod data sheet 84% by volume

Successfully tested at
cryogenic temperatures at
Service temperature limits Prod data sheet -50°C to +80°C
which it still gives an acceptable
elasticity

Application temperature Prod data sheet +10 to +25°C


Drying Prod data sheet Non drying skin in 1 to 3 hours
Colour Prod data sheet grey
Permeability Prod data sheet 0.01 perm
Water vapour diffusion resistance Prod data sheet Factor µ = ± 23,000
Fire resistance Prod data sheet dry: combustible
Solvent Prod data sheet mineral oil solvents
Flash point Prod data sheet minimum +40°C
Coverage range Prod data sheet 5.2 kg/m² for 3 mm final layer

shelf life: 2 years in original


Storage Prod data sheet from 0 to +45°C
unopened container

NOTE: Pittsburgh Corning PITTSEAL 444N, Foster FLEXTRA 95-50 or equivalent.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 44 of 65

Appendix 2

Material specifications N°105


INSULATION BONDING ADHESIVE Form: drum

Documents
Properties Min/max values Remarks
Reference

two parts adhesive, modified bitumen based for component 1 and


Product
isocyanate for component 2

Apparent density Prod data sheet 1.05 kg/dm3

component 1: 42 parts
Mixing ratio, by weight Prod data sheet
component 2: 1 part

minimum - 40°C on stainless


Service temperature limits Prod data sheet -50°C to +80°C steel or aluminium maximum
120°C for low strength

Application temperature Prod data sheet + 20 to + 35°C Substrate: + 5 to + 35°C


Pot life Prod data sheet 2 to 2h30 at 25°C ambient
Colour Prod data sheet black
Permeability Prod data sheet 0.01 perm cm
Water vapour diffusion resistance Prod data sheet Factor µ = ± 23,000
Fire resistance Prod data sheet dry: combustible

white spirit or chlorinated


Solvent Prod data sheet for tools cleaning
solvent

Flash point Prod data sheet minimum +40°C

depend on substrate or
Coverage range Prod data sheet 3 kg/m²
application method

maximum 2 1/2 years in original


Storage Prod data sheet from 0 to +45°C
unopened container

NOTE: Pittsburgh Corning PC 88, Foster 81-84 adhesive sealant or equivalent.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 45 of 65

Appendix 2

Material specifications N°106


CRYOGENIC ADHESIVE/COATING for vapour stop Form: drum

Documents
Properties Min/max values Remarks
Reference

two parts elastomeric adhesive / coating for use in cryogenic


Product
application

Apparent density ASTM D1475 1.15 kg/dm3


Mixing ratio, by weight Prod data sheet 1: 1 by volume
Solids (non-volatile) ASTM C461 73.5% by weight
Service temperature limits Prod data sheet -196°C to +121°C
Application temperature Prod data sheet +4 to +38°C
Pot life Prod data sheet 6 to 9 h at 25°C ambient
Bonding time range Prod data sheet 20 to 60 minutes
Drying time ASTM D1640 Through: 48 hours Full cure: 2 weeks
Colour Prod data sheet black

ASTM F1249 0.01 perm 0.51 to 0.64 mm dry film


Permeability
ASTM E398 0.01 perm 0.76 to 0.89 mm dry film
Elongation ASTM D412 200%
Tensile strengh ASTM D412 207 N/cm²
Fire resistance Prod data sheet dry: combustible
Flash point ASTM D93 +26.7°C

for 1.22 to 1.42 mm, depend on


Wet coverage range Prod data sheet 1.22 to 1.43 l/m²
substrate or application method

Storage Prod data sheet +4 to +38°C

NOTE: Foster 90-66 cryogenic adhesive or equivalent.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 46 of 65

Appendix 2

Material specifications N°107


COATING MASTIC Form: drum

Documents
Properties Min/max values Remarks
Reference

Tough, flexible and fire resistive elastomeric mastic containing


Product
DuPont Hypalon® rubber

Apparent density ASTM D1475 1.20 to 1.25 kg/dm3


Solids (non-volatile) ASTM D1644 60% by weight
Service temperature limits Prod data sheet -46°C to +104°C
Application temperature Prod data sheet +4 to +38°C
Drying time ASTM D1640 Set to touch: 3 hours Dry touch: 48 hours
Colour Prod data sheet White or Grey

ASTM F1249 0.03 perm 0.76 mm dry film


Permeability
ASTM E96 0.024 perm 1.3 mm dry film

Fire resistance ASTM E84 Flame spread: 10 Smoke developed: 15


Flash point ASTM D93 +43°C

for 2 mm (0.9 mm dry


Wet coverage range Prod data sheet 2 to 2.4 l/m² thickness), depend on substrate
or application method

Storage Prod data sheet +4 to +38°C

NOTE: Foster 60-90/91 Monolar mastic, BS Coating HYPALKOTE 570 or equivalent.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 47 of 65

Appendix 2

Material specifications N°108


ALUMINIUM-BUTYL MEMBRANE Form: 50 to 1000 mm wide rolls

Documents
Properties Min/max values Remarks
Reference

heavy duty, self vulcanising tape with aluminium/polyester


Product
laminate backing and a strong self bonding layer

Compound of an elastomeric modified butyl rubber, pressure


sensitive adhesive laminated with a 48 mic. thick
Construction
Aluminium/Polyester (25 mic. Aluminium + 23 mic. Polyester)
laminate foil and a silicone treated paper liner

Apparent density Prod data sheet 1.1 g/cm³


Thickness Prod data sheet 1.2 mm ± 3%
Solids (non-volatile) Prod data sheet 100%
Service temperature limits Prod data sheet -30°C to +85°C
Tack Prod data sheet immediatly
Bonding time Prod data sheet 24 hours max.
Adhesion Prod data sheet 2.0 kg/cm on galvanised steel
Pressure rating Prod data sheet max. 4,000 Pa measured at 20°C
Colour Prod data sheet Bright aluminium

0.00 Metric perm for the complete product


Permeability Prod data sheet
0.02 Metric perm for the elastomeric butyl rubber
Flammability DIN 4102-1 Class 1 B2 UL-listed

2 years in closed original


Storage Prod data sheet dry
packing

NOTE: IWR 701 AP, Temati TEMBUTIL IF or equivalent.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 48 of 65

Appendix 2

Material specifications N°109


SELF ADHESIVE BANDS Form: 12 to 75 mm wide x 50 m long rolls

Documents
Properties Min/max values Remarks
Reference

Product glass reinforced filament tape 10 mm

Rubber-resine adhesive with polypropylene backing biaxially


Construction
oriented

Total thickness Prod data sheet 135 microns


Backing thickness Prod data sheet 32 microns
Adhesion to steel Prod data sheet 9.6 N/10 mm
Tensile strength Prod data sheet 250 N/10 mm
Service temperature limits Prod data sheet -35°C to +130°C
Elongation Prod data sheet 8.5%
Static shear Prod data sheet 4500 minutes
Colour Prod data sheet Transparent
Storage

NOTE: IWR Glass reinforced filament tape mm10 or equivalent.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 49 of 65

Appendix 2

Material specifications N°110


BUTYL RUBBER SHEET Form: 1 mm thick x 1 m wide x 12 m long rolls

Documents
Properties Min/max values Remarks
Reference

Product Polyisobutylene (PIB) sheeting for contraction joints


Construction High molecular weight polyisobutylene
Total thickness Prod data sheet 0.5 to 2 mm
Chemical resistance Prod data sheet majority of chemicals

aromatic, aliphatic, hydrocarbon


Oil resistance Prod data sheet attacked by:
oils

Tensile strength Prod data sheet 2.5 MN/mm²


Service temperature limits Prod data sheet -34°C to +72°C
Elongation Prod data sheet 300%
Vapour permeability Prod data sheet 5.0 g/m/,001"/m²/day at 38°C
Colour Prod data sheet black

to seal overlapping seams by


"B" type for tropical or "E" type
Welding agent Prod data sheet means of vulcanisation of butyl
for moderate climates
rubber sheet

NOTE: IWR Butyl rubber sheet or equivalent.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 50 of 65

Appendix 2

Material specifications N°111


REINFORCING FABRIC for VAPOUR STOP Form: 0.76 m wide x 183 m long rolls

Documents
Properties Min/max values Remarks
Reference

Synthetic fibre fabric for vapour stop or coating mastic


Product
reinforcement

Construction Polyester with PVA finish, 18 ends, 8 picks

Weave Prod data sheet Leno


Visual mesh Prod data sheet 9 x 18 openings per square inch
Elongation Prod data sheet 70 to 90% in water base mastic
Weight Prod data sheet 30.5 g/m²
Service temperature limits Prod data sheet +121°C
Colour Prod data sheet white
Storage

NOTE: FOSTER MAST-A-FAB® or equivalent.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 51 of 65

Appendix 2

Material specifications N°112


REINFORCING FABRIC for COATING MASTIC Form: 1.0 m wide x 50 m long rolls

Documents
Properties Min/max values Remarks
Reference

Product Fibreglass scrim fabric for coating mastic reinforcement


Construction Fibreglass coated with weavelock, 3.8 x 3.9 setting/cm

Weave Prod data sheet Leno


Visual mesh Prod data sheet 10 x 10 openings per square inch
Thickness Prod data sheet 0.20 mm
Tensile strength Prod data sheet 85 x 75 daN/5 cm warp x weft
Weight Prod data sheet 58 g/m²
Service temperature limits Prod data sheet 300°C
Fire classification Prod data sheet M0
Storage

NOTE: FOSTER SCRIMTEX™ or equivalent.

REINFORCING FABRIC for COATING MASTIC Form: 1.0 m wide x 45 m long rolls

Documents
Properties Min/max values Remarks
Reference

Product Synthetic fabric for coating mastic reinforcement


Construction Polyester with 3.175 mm opening

Visual mesh Prod data sheet 6x6 openings per square inch
Thickness Prod data sheet 0.70 mm
Tensile strength Prod data sheet 280 x 550 N warp x weft
Weight Prod data sheet 90 g/m²
Service temperature limits Prod data sheet -35 to +80°C
Fire classification Prod data sheet combustible
Storage

NOTE: Pittsburgh Corning PC 79 or equivalent.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 52 of 65

Appendix 2

Material specifications N°114


MULTIPLEX FOIL Form: Roll up to 1.0 m wide

Documents
Properties Min/max values Remarks
Reference

Three layer lamination of polyester film/aluminium foil/polyester


Product
film

12 microns polyester film + 25 microns aluminium foil +


Construction
12 microns polyester film

Density Prod data sheet 2.2 kg/dm³


Weight Prod data sheet 110 g/m²
Tensile strength MD ASTM D882 8.3 kg/15x100m
Tensile strength TD ASTM D882 10 kg/15x100m
Elongation MD Prod data sheet 54%
Elongation TD Prod data sheet 58%
Friction film/film Prod data sheet 0.45 Kinetic
Humidity absorption Prod data sheet < 0.3%
Steam permeability Prod data sheet 0.000001 g/m².24h.mm HG
µ value Prod data sheet > 2 x 10-6 practically water vapour tight
Temperature resistance Prod data sheet -60 to +150°C
Melting point Prod data sheet 250 to 265°C
Storage

NOTE: FOSTER SCRIMTEX™ or equivalent.

MULTIPLEX FOIL ADHESIVE TAPE Form: 12, 25, 50, 75, 100 mm wide x 50 m long rolls

Documents
Properties Min/max values Remarks
Reference

Three layer lamination of polyester film/aluminium foil/polyester


Product
film

12 microns polyester film + 25 microns aluminium foil +


Construction 12 microns polyester film + solvent based acrylic adhesive and
removable silicone paper

Weight Prod data sheet 150 g/m²


Temperature resistance Prod data sheet -60 to +150°C
Other properties Prod data sheet As above

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 53 of 65

Appendix 3

Appendix 3 Principle sketches

N°301: Cold insulation - operating temperature -50°C to ambient - Vapour stop and insulation
termination
N°302: Cold insulation - operating temperature < -50°C - Vapour stop and insulation
termination
N°303: Cold insulation - Valve and flanged joint
N°304: Cold insulation - Contraction joint
N°305: Cold insulation - Pipe support (1/2)
N°306: Cold insulation - Pipe support (2/2)
N°307: Cold insulation - Equipment details (1/2)
N°308: Cold insulation - Equipment details (2/2)
N°309: Cold insulation - GRP cladding - pre-cured pipe sections and moulded pieces
N°310: Cold insulation - Tee, branches, nozzles
N°311: Cold insulation - GRP cladding reinforcement - vessel and equipment Ø ≥ 1200 mm

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 54 of 65

Appendix 3

Principle sketch N°301

Cold insulation
Operating temperature -50°C to ambient
Vapour stop and insulation termination

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 55 of 65

Appendix 3

Principle sketch N°302

Cold insulation
Operating temperature < -50°C
Vapour stop and insulation termination

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 56 of 65

Appendix 3

Principle sketch N°303

Cold insulation
Valve and flanged joint

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 57 of 65

Appendix 3

Principle sketch N°304

Cold insulation
Contraction joint

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 58 of 65

Appendix 3

Principle sketch N°305

Cold insulation
Pipe support (1/2)

Note: Vapour barrier on high density polyisocyanurate shall be a bonded aluminum foil (no Alu-
Butyl membrane).

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 59 of 65

Appendix 3

Principle sketch N°306

Cold insulation
Pipe support (2/2)

Note: Vapour barrier on high density polyisocyanurate shall be a bonded aluminum foil (no Alu-
Butyl membrane).

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 60 of 65

Appendix 3

Principle sketch N°307

Cold insulation
Equipment details (1/2)

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 61 of 65

Appendix 3

Principle sketch N°308

Cold insulation
Equipment details (2/2)

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 62 of 65

Appendix 3

Principle sketch N°309

Cold insulation
GRP cladding
Pre-cured pipe sections and moulded pieces

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 63 of 65

Appendix 3

Principle sketch N°310

Cold insulation
Tees, branches, nozzles

Note: GRP cladding pre-moulded tee or pre-moulded sections + GRP piece prepared and
applied on site may be used as well for one layer than two layers insulation application.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 64 of 65

Appendix 3

Principle sketch N°311

Cold insulation
GRP Cladding reinforcement
Vessel and equipment Ø ≥ 1200 mm

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.
Afnor, WEBPORT le 19/03/2019 à 14:06 GS EP COR 772 (Edition 2019 - REV 02):2017-10
Pour : Saipem 1 +

General Specification GS EP COR 772

Thermal insulation (cold service)

Rev.: 02 Effective date: 10/2017 Page: 65 of 65

Revision summary

Rev 02: 10/2017


• § 4: New paragraph: Insulation systems.
• § 5: Change of the fire requirement.
• § 7.7: New requirement added: “100% of the painted surface shall be holiday detected
according GS EP COR 350 (no holidays) just before fitting the thermal insulation”.
• § 7.1: New requirement for stainless steel added: “On austenitic stainless steel, insulation
shall comply with ASTM C795”.
• Appendix 2: Update of the insulation material properties.

This document is the property of TOTAL S.A., it contains confidential information which may not be disclosed to any third party,
reproduced, stored or transmitted without the prior written consent of TOTAL S.A.
The information contained in this document does not substitute for applicable laws and regulations.