Download as pdf or txt
Download as pdf or txt
You are on page 1of 14

GUYED TOWERS - 25G G

S TA N D A R D 2 5 G G U Y E D T O W E R
SECTIONS

6 1/2”
9 3/4” QUICK REFERENCE
PARTS & ACCESSORIES PAGES 37-40
GROUNDING INFORMATION PAGE 41
11 1/4”
FOUNDATION INFORMATION PAGES 41-44

2.25” O.D.
2.08” I.D.
1’ 6” (14 GA.)

Optional Waveguide
Brackets (KY2041A)
1’ 3”
9’ 9”

1 1/4” O.D.
1 1/4” O.D. (16 GA.)
(16 GA.)

5/16” O.D. ~
~ 5/16” O.D.
Solid Bracing Solid Bracing

Optional double braced sections STANDARD TOP SECTION


are available upon request. 25AG2

Additional 25G top sections


are shown on page 37.

CONCRETE BASE PLATE


BPC25G*
STANDARD SECTION FOR USE WITH 3/4X12PP PIER PIN
25G - 10’ Section EMBEDDED IN CONCRETE.

OPTIONAL 7’ SECTION Additional base sections are


25G7 - 7‘ Section available, please see page 38.
The 7’ Section is UPS shippable.

* Towers mounted on these bases must be bracketed or guyed at all times. Temporary steel guying may also be necessary during installation and dismantling.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard 25
© 2011 ROHN PRODUCTS LLC
GUYED TOWERS - 25G G
S TA N D A R D D E S I G N - 2 5 G
9 0 M P H R E V. G , 7 0 M P H R E V. F
40’ TOWER FDNS
22.6 OR 16.6 25G 25AG2 BPC25G GA25GD BASE ANCHOR
35’
TOWER PARTS
22.0 INCLUDED
47’ 3 1 1 1 CB1G AB2
3/16” EHS
(399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
40’ ROHN 25G
Al l par ts shown i n tabl e
CONNECTIONS
175’ 6 6 3 3 a re i nc l ud ed when ord er i ng
INCLUDED
Par t No: 25G90R 040
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
32’ GROUNDING
P/N: 25G90R040 INCLUDED 3 1 3 3 1

50’ TOWER FDNS


21.4 OR 15.8 25G 25AG2 BPC25G GA25GD
45’
TOWER PARTS BASE ANCHOR
21.0
INCLUDED 4 1 1 2 CB1G AB2
60’
3/16” EHS
GUYS &
50’ ROHN 25G
(399#) 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
23’ CONNECTIONS
46’ a re i nc l ud ed when ord er i ng
INCLUDED 350’ 12 12 6 3
Par t No: 25G90R 050
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
40’ GROUNDING
P/N: 25G90R050 INCLUDED 3 1 3 3 1

60’ TOWER FDNS


20.3 OR 15.2 25G 25AG2 BPC25G GA25GD BASE ANCHOR
55’
TOWER PARTS
20.2 INCLUDED
73’ 5 1 1 2 CB1G AB2
3/16” EHS
(399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY 60’ ROHN 25G
Al l par ts shown i n tabl e
28’ CONNECTIONS
56’
425’ 12 12 6 3 a re i nc l ud ed when ord er i ng
INCLUDED
Par t No: 25G90R 060
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
48’ GROUNDING
P/N: 25G90R060 INCLUDED 3 1 3 3 1

70’ TOWER FDNS


19.4 OR 14.7 25G 25AG2 BPC25G GA25GD BASE ANCHOR
65’
TOWER PARTS
19.4 INCLUDED
86’ 6 1 1 2 CB1G AB2
3/16” EHS
GUYS & BG2142
70’ ROHN 25G
(399#) 3/16EHS 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
32’ CONNECTIONS
64’ a re i nc l ud ed when ord er i ng
INCLUDED 500’ 12 12 6 3
Par t No: 25G90R 070
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
56’ GROUNDING
P/N: 25G90R070 INCLUDED 3 1 3 3 1

80’ TOWER FDNS


18.6 OR 14.3 25G 25AG2 BPC25G GA25GD BASE ANCHOR
75’
TOWER PARTS
18.8
INCLUDED 7 1 1 3 CB1G AB2
99’
3/16” EHS
GUYS &
80’ ROHN 25G
50’ (399#) 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
81’ CONNECTIONS
a re i nc l ud ed when ord er i ng
INCLUDED 800’ 18 18 9 3
Par t No: 25G90R 080
25’ 69’
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
64’ GROUNDING
P/N: 25G90R080 INCLUDED 3 1 3 3 1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
27
© 2011 ROHN PRODUCTS LLC
G GUYED TOWERS - 25G

S TA N D A R D D E S I G N - 2 5 G
9 0 M P H R E V. G , 7 0 M P H R E V. F
GA25GD BASEFDNS
90’ TOWER
25G 25AG2 BPC25G
85’
18.0 OR 13.9 TOWER PARTS ANCHOR
18.4 INCLUDED 8 1 1 3 CB1G AB2
111’
3/16” EHS
90’ ROHN 25G
57’
(399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
92’ CONNECTIONS a re i nc l ud ed when ord er i ng
INCLUDED 900’ 18 18 9 3 Par t No: 25G90R 090
28’ 77’
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
72’ GROUNDING
P/N: 25G90R090 INCLUDED 3 1 3 3 1

100’ TOWER
FDNS
17.5 OR 13.6 25G 25AG2 BPC25G GA25GD BASE ANCHOR
95’ TOWER PARTS
18.0
INCLUDED 9 1 1 3 CB1G AB2
124’
3/16” EHS 100’ ROHN 25G
63’
(399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
102’ CONNECTIONS a re i nc l uded when order i ng
INCLUDED 1000’ 18 18 9 3 Par t No: 2590R 100
31’ 86’
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
80’ GROUNDING
P/N: 25G90R100 INCLUDED 3 1 3 3 1

110’ TOWER
25AG2 FDNS
25G BPC25G GA25GD BASE ANCHOR
105’
17.0 OR 13.4
TOWER PARTS
17.6
INCLUDED 10 1 1 3 CB1G AB2
137’
3/16” EHS
110’ ROHN 25G
70’
(399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
112’ CONNECTIONS a re i nc l uded when order i ng
INCLUDED 1100’ 18 18 9 3 Par t No: 25G90R 110
35’ 95’
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
88’ GROUNDING
P/N: 25G90R110 INCLUDED 3 1 3 3 1

120’ TOWER
25AG2 FDNS
16.6 OR 13.1 25G BPC25G GA25GD BASE ANCHOR
115’ TOWER PARTS
17.2
INCLUDED 11 1 1 4 CB1G AB2
150’
85’ 3/16” EHS 120’ ROHN 25G
128’ (399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
55’
111’
CONNECTIONS a re i nc l uded when order i ng
INCLUDED 1575’ 24 24 12 3 Par t No: 25G90R 120
28’ 100’
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
96’ GROUNDING
P/N: 25G90R120 INCLUDED 3 1 3 3 1

130’ TOWER FDNS


25G 25AG2 BPC25G GA25GD BASE ANCHOR
125’
16.2 OR 12.9 TOWER PARTS
17.0 INCLUDED 12 1 1 4 CB1G AB2
163’
93’ 3/16” EHS
130’ ROHN 25G
140’ (399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
62’ CONNECTIONS a re i nc l uded when order i ng
121’
INCLUDED 1700’ 24 24 12 3 Par t No: 25G90R 130
31’ 108’
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
104’ GROUNDING
P/N: 25G90R130 INCLUDED 3 1 3 3 1

28 Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
© 2011 ROHN PRODUCTS LLC
GUYED TOWERS - 25G G
S TA N D A R D D E S I G N - 2 5 G
9 0 M P H R E V. G , 7 0 M P H R E V. F
140’ TOWER FDNS
25G 25AG2 BPC25G GA25GD BASE ANCHOR
135’
15.9 OR 12.7 TOWER PARTS
16.6 INCLUDED 13 1 1 4 CB1G AB2
175’
99’ 3/16” EHS
140’ ROHN 25G
149’ (399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
66’ CONNECTIONS a re i nc l ud ed when ord er i ng
130’
INCLUDED 1825’ 24 24 12 3 Par t No: 25G90R 140
33’ 117’
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
112’ GROUNDING
P/N: 25G90R140 INCLUDED 3 1 3 3 1

150’ TOWER FDNS


25G 25AG2 BPC25G GA25GD BASE ANCHOR
145’
15.5 OR 12.5 TOWER PARTS
16.4 INCLUDED 14 1 1 5 CB1G AB2
116’ 188’
3/16” EHS
150’ ROHN 25G
167’
87’
148’
(399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
58’ CONNECTIONS a re i nc l ud ed when ord er i ng
133’ INCLUDED 2425’ 30 30 15 3 Par t No: 25G90R 150
29’ 123’
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
120’ GROUNDING
P/N: 25G90R150 INCLUDED 3 1 3 3 1

160’ TOWER FDNS


25G 25AG2 BPC25G GA25GD BASE ANCHOR
155’
15.3 OR 12.3 TOWER PARTS
16.2 INCLUDED 15 1 1 5 CB1G AB2
124’ 201’
3/16” EHS
160’ ROHN 25G
178’
93’
158’
(399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
62’ CONNECTIONS a re i nc l ud ed when ord er i ng
142’ INCLUDED 2600’ 30 30 15 3 Par t No: 25G90R 160
31’ 132’
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
128’ GROUNDING
P/N: 25G90R160 INCLUDED 3 1 3 3 1

170’ TOWER FDNS


25G 25AG2 BPC25G GA25GD BASE ANCHOR
165’
15.0 OR 12.2 TOWER PARTS
16.0 INCLUDED 16 1 1 5 CB1G AB2
132’ 214’
3/16” EHS
170’ ROHN 25G
190’
99’
168’
(399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
66’ CONNECTIONS a re i nc l ud ed when ord er i ng
151’ INCLUDED 2750’ 30 30 15 3 Par t No: 25G90R 170
33’ 140’
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
136’ GROUNDING
P/N: 25G90R170 INCLUDED 3 1 3 3 1

180’ TOWER FDNS


25G 25AG2 BPC25G GA25GD BASE ANCHOR
175’
14.8 OR 12.0 TOWER PARTS
15.8 INCLUDED 17 1 1 5 CB1G AB2
139’ 227’
3/16” EHS
180’ ROHN 25G
200’
105’
178’
(399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
69’ CONNECTIONS a re i nc l uded when order i ng
160’ INCLUDED 2925’ 30 30 15 3 Par t No: 25G90R 180
35’ 148’
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
144’ GROUNDING
P/N: 25G90R180 INCLUDED 3 1 3 3 1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
29
© 2011 ROHN PRODUCTS LLC
G GUYED TOWERS - 25G

S TA N D A R D D E S I G N - 2 5 G
9 0 M P H R E V. G , 7 0 M P H R E V. F
190’ TOWER FDNS
14.5 OR 11.9
TOWER PARTS 25G 25AG2 BPC25G GA25GD BASE ANCHOR
185’
15.6
INCLUDED 18 1 1 5 CB1G AB2
239’
148’
3/16” EHS
190’ ROHN 25G
111’
212’ (399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
188’ CONNECTIONS a re i nc l ud ed when ord er i ng
74’
169’ INCLUDED 3075’ 30 30 15 3 Par t No: 25G90R 190
37’ 156’ ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
152’ GROUNDING
P/N: 25G90R190 INCLUDED 3 1 3 3 1

30 Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
© 2011 ROHN PRODUCTS LLC
GUYED TOWERS - 25G G
S TA N D A R D D E S I G N - 2 5 G
1 1 0 M P H R E V. G , 9 0 M P H R E V. F
40’ TOWER
FDNS
13.4 OR 9.7
TOWER PARTS 25G 25AG2 BPC25G GA25GD BASE ANCHOR
35’
13.4
INCLUDED 3 1 1 1 CB1G AB2
47’
3/16” EHS
40’ ROHN 25G
(399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
CONNECTIONS a re i nc l uded when order i ng
INCLUDED 175’ 6 6 3 3 Par t No: 25G110R 040

ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP


32’ GROUNDING
P/N: 25G110R040 INCLUDED 3 1 3 3 1

50’ TOWER
FDNS
12.6 OR 9.1
TOWER PARTS 25G 25AG2 BPC25G GA25GD BASE ANCHOR
45’
12.6 INCLUDED 4 1 1 2 CB1G AB2
60’
3/16” EHS
GUYS &
50’ ROHN 25G
(399#) 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
22’ CONNECTIONS
46’ a re i nc l ud ed when ord er i ng
INCLUDED 350’ 12 12 6 3
Par t No: 25G110R 050
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
40’ GROUNDING
P/N: 25G110R050 INCLUDED 3 1 3 3 1

60’ TOWER FDNS


11.9 OR 8.7 TOWER PARTS 25G 25AG2 BPC25G GA25GD BASE ANCHOR
55’
12.2 INCLUDED 5 1 1 2 CB1G AB2
73’
3/16” EHS 60’ ROHN 25G
(399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
28’ CONNECTIONS
56’ a re i nc l ud ed when ord er i ng
INCLUDED 425’ 12 12 6 3
Par t No: 25G110R 060
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
48’ GROUNDING
P/N: 25G110R060 INCLUDED 3 1 3 3 1

70’ TOWER FDNS


11.3 OR 8.6 TOWER PARTS 25G 25AG2 BPC25G GA25GD BASE ANCHOR
65’
11.8 INCLUDED 6 1 1 2 CB1G AB2
86’
70’ ROHN 25G
3/16” EHS
(399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
32’ CONNECTIONS a re i nc l ud ed when ord er i ng
64’
INCLUDED 500’ 12 12 6 3 Par t No: 25G110R 070

ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP


56’ GROUNDING
P/N: 25G110R070 INCLUDED 3 1 3 3 1

80’ TOWER FDNS


10.9 OR 8.3 TOWER PARTS 25G 25AG2 BPC25G GA25GD BASE ANCHOR
75’
11.4 INCLUDED 7 1 1 3 CB1G AB2
99’
80’ ROHN 25G
3/16” EHS
50’ (399#) GUYS & 3/16 EHS BG2142 5/16 THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
81’ CONNECTIONS a re i nc l ud ed when ord er i ng
INCLUDED 800’ 18 18 9 3 Par t No: 25G110R 080
25’ 69’
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
64’ GROUNDING
P/N: 25G110R080 INCLUDED 3 1 3 3 1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard 31
© 2011 ROHN PRODUCTS LLC
G GUYED TOWERS - 25G

S TA N D A R D D E S I G N - 2 5 G
1 1 0 M P H R E V. G , 9 0 M P H R E V. F
90’ TOWER FDNS
10.5 OR 8.1
TOWER PARTS 25G 25AG2 BPC25G GA25GD BASE ANCHOR
85’
11.2
INCLUDED 8 1 1 3 CB1G AB2
111’
3/16” EHS 90’ ROHN 25G
56’
(399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
91’ CONNECTIONS a re i nc l ud ed when ord er i ng
INCLUDED 900’ 18 18 9 3 Par t No: 25G110R 090
28’ 77’
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
72’ GROUNDING
P/N: 25G110R090 INCLUDED 3 1 3 3 1

100’ TOWER FDNS


10.2 OR 7.9 TOWER PARTS 25G 25AG2 BPC25G GA25GD BASE ANCHOR
95’
10.8 INCLUDED 9 1 1 3 CB1G AB2
124’
3/16” EHS
100’ ROHN 25G
63’
(399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
102’ CONNECTIONS a re i nc l uded when order i ng
INCLUDED 1000’ 18 18 9 3 Par t No: 25G110R 100
32’ 86’
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
80’ GROUNDING
P/N: 25G110R100 INCLUDED 3 1 3 3 1

110’ TOWER FDNS


9.9 OR 7.8 TOWER PARTS 25G 25AG2 BPC25G GA25GD BASE ANCHOR
105’
10.6 INCLUDED 10 1 1 3 CB1G AB2
137’
3/16” EHS
110’ ROHN 25G
70’
(399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
112’ CONNECTIONS a re i nc l uded when order i ng
INCLUDED 1100’ 18 18 9 3 Par t No: 25G110R 110
35’ 95’
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
88’ GROUNDING
P/N: 25G110R110 INCLUDED 3 1 3 3 1

120’ TOWER FDNS


9.7 OR 7.6 TOWER PARTS 25G 25AG2 BPC25G GA25GD BASE ANCHOR
115’
10.4 INCLUDED 11 1 1 4 CB1G AB2
150’
86’ 3/16” EHS
120’ ROHN 25G
129’ (399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
57’ CONNECTIONS a re i nc l uded when order i ng
112’
INCLUDED 1575’ 24 24 12 3 Par t No: 25G110R 120
28’ 100’
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
96’ GROUNDING
P/N: 25G110R120 INCLUDED 3 1 3 3 1

GA25GD BASEFDNS
130’ TOWER
25G 25AG2 BPC25G
125’
9.3 OR 7.5 TOWER PARTS ANCHOR
10.2 INCLUDED 12 1 1 4 CB1G AB2
93’
163’
130’ ROHN 25G
3/16” EHS
140’ (399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
62’ CONNECTIONS a re i nc l uded when order i ng
121’
INCLUDED 1700’ 24 24 12 3 Par t No: 25G110R 130
31’ 109’
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
104’ GROUNDING
P/N: 25G110R130 INCLUDED 3 1 3 3 1

32 Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
© 2011 ROHN PRODUCTS LLC
GUYED TOWERS - 25G G
S TA N D A R D D E S I G N - 2 5 G
1 1 0 M P H R E V. G , 9 0 M P H R E V. F
140’ TOWER FDNS
9.2 OR 7.4 TOWER PARTS 25G 25AG2 BPC25G GA25GD BASE ANCHOR
135’
10.0 INCLUDED 13 1 1 4 CB1G AB2
175’
101’ 140’ ROHN 25G
151’ 3/16” EHS
(399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY All par ts shown i n tabl e
67’ CONNECTIONS a re i nc l uded when order i ng
131’
INCLUDED 1825’ 24 24 12 3 Par t No: 25G110R 140
33’ 117’
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
112’ GROUNDING
P/N: 25G110R140 INCLUDED 3 1 3 3 1

150’ TOWER FDNS


9.0 OR 7.3
TOWER PARTS 25G 25AG2 BPC25G GA25GD BASE ANCHOR
145’
9.9
INCLUDED 14 1 1 5 CB1G AB2
116’ 188’
150’ ROHN 25G
87’
167’ 3/16” EHS
(399#)
GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
148’ CONNECTIONS a re i nc l uded when order i ng
58’
133’ INCLUDED 2425’ 30 30 15 3 Par t No: 25G110R 150
29’ 123’ ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
120’ GROUNDING
P/N: 25G110R150 INCLUDED 3 1 3 3 1

160’ TOWER
FDNS
8.8 OR 7.2
TOWER PARTS 25G 25AG2 BPC25G GA25GD BASE ANCHOR
155’
9.8
INCLUDED 15 1 1 5 CB1G AB2
124’ 201’
160’ ROHN 25G
93’
178’ 3/16” EHS
(399#)
GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
158’ CONNECTIONS a re i nc l uded when order i ng
62’
142’ INCLUDED 2600’ 30 30 15 3 Par t No: 25G110R 160
31’ 132’ ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
128’ GROUNDING
P/N: 25G110R160 INCLUDED 3 1 3 3 1

170’ TOWER INNER OUTER


8.7 OR 7.1 TOWER PARTS 25G 25AG2 BPC25G GA25GD BASE ANCHOR ANCHOR
165’
9.7 INCLUDED 16 1 1 6 CB2G AB2 AB2
138’
214’ 170’ ROHN 25G
3/16” EHS Al l par ts shown i n
110’ 194’ (399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY
83’
175’
CONNECTIONS tabl e are i nc l uded
159’
INCLUDED 2800’ 36 36 18 6 when ord er i ng
55’ Par t No: 25G110R 170
74’
28’ 57’ ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
50’ 136’ GROUNDING
P/N: 25G110R170 INCLUDED 6 2 3 6 1

180’ TOWER
25G 25AG2 BPC25G GA25GD BASE INNER OUTER
176’
8.6 OR 7.0 TOWER PARTS ANCHOR ANCHOR
9.6 INCLUDED 17 1 1 6 CB2G AB2 AB2
145’
227’
180’ ROHN 25G
3/16” EHS Al l par ts shown i n
116’ 204’ (399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY tabl e are i nc l uded
87’
185’
168’
CONNECTIONS when ord er i ng
58’ INCLUDED 2925’ 36 36 18 6 Par t No: 25G110R 180
77’
29’ 58’ ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
50’ 144’ GROUNDING
P/N: 25G110R180 INCLUDED 6 2 3 6 1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
33
© 2011 ROHN PRODUCTS LLC
G GUYED TOWERS - 25G

S TA N D A R D D E S I G N - 2 5 G
1 1 0 M P H R E V. G , 9 0 M P H R E V. F
190’ TOWER
INNER OUTER
8.5 OR 6.9 TOWER PARTS 25G 25AG2 BPC25G GA25GD BASE ANCHOR ANCHOR
186’
9.5 INCLUDED 18 1 1 6 CB2G AB2 AB2
155’
240’
3/16” EHS
190’ ROHN 25G
124’ 217’ (399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n
196’
93’ 178’
CONNECTIONS tabl e are i nc l uded
INCLUDED 3100’ 36 36 18 6 when ord er i ng
62’ 80’
Par t No: 25G110R 190
31’ 59’ ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
50’ 152’ GROUNDING
P/N: 25G110R190 INCLUDED 6 2 3 6 1

34 Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
© 2011 ROHN PRODUCTS LLC
GUYED TOWERS - 25G G
S TA N D A R D D E S I G N - 2 5 G
1 3 0 M P H R E V. G , 1 1 0 M P H R E V. F
40’ TOWER FDNS
10.8 OR 7.9
TOWER PARTS 25G 25AG2 BPC25G GA25GD BASE ANCHOR
38’
11.2
INCLUDED 3 1 1 1 CB1G AB2
50’
3/16” EHS
40’ ROHN 25G
(399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
CONNECTIONS a re i nc l uded when order i ng
INCLUDED 175’ 6 6 3 3 Par t No: 25G130R 040

ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP


32’ GROUNDING
P/N: 25G130R040 INCLUDED 3 1 3 3 1

50’ TOWER FDNS


10.1 OR 7.5 TOWER PARTS 25G 25AG2 BPC25G GA25GD BASE ANCHOR
48’
10.0 INCLUDED 4 1 1 2 CB1G AB2
62’ 50’ ROHN 25G
3/16” EHS
(399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
22’ CONNECTIONS a re i nc l uded when order i ng
46’
INCLUDED 350’ 12 12 6 3 Par t No: 25G130R 050

ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP


40’ GROUNDING
P/N: 25G130R050 INCLUDED 3 1 3 3 1

60’ TOWER FDNS


9.7 OR 7.2
TOWER PARTS 25G 25AG2 BPC25G GA25GD BASE ANCHOR
58’
9.8
INCLUDED 5 1 1 2 CB1G AB2
75’
60’ ROHN 25G
3/16” EHS
(399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
28’
56’
CONNECTIONS a re i nc l uded when order i ng
INCLUDED 425’ 12 12 6 3 Par t No: 25G130R 060

ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP


48’ GROUNDING
P/N: 25G130R060 INCLUDED 3 1 3 3 1

70’ TOWER
FDNS
9.2 OR 7.0
TOWER PARTS 25G 25AG2 BPC25G GA25GD BASE ANCHOR
68’
9.6
INCLUDED 6 1 1 2 CB1G AB2
88’
3/16” EHS
70’ ROHN 25G
(399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
32’
64’
CONNECTIONS a re i nc l uded when order i ng
INCLUDED 500’ 12 12 6 3 Par t No: 25G130R 070

ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP


56’ GROUNDING
P/N: 25G130R070 INCLUDED 3 1 3 3 1

80’ TOWER FDNS


8.9 OR 6.8
TOWER PARTS 25G 25AG2 BPC25G GA25GD BASE ANCHOR
78’
9.4 INCLUDED 7 1 1 3 CB1G AB2
101’
3/16” EHS
80’ ROHN 25G
50’ (399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
81’ CONNECTIONS a re i nc l uded when order i ng
INCLUDED 800’ 18 18 9 3 Par t No: 25G130R 080
25’ 69’
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
64’ GROUNDING
P/N: 25G130R080 INCLUDED 3 1 3 3 1

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
35
© 2011 ROHN PRODUCTS LLC
G GUYED TOWERS - 25G

S TA N D A R D D E S I G N - 2 5 G
1 3 0 M P H R E V. G , 1 1 0 M P H R E V. F
90’ TOWER
FDNS
8.6 OR 6.7
TOWER PARTS 25G 25AG2 BPC25G GA25GD BASE ANCHOR
88’
9.2
INCLUDED 8 1 1 3 CB1G AB2
114’
3/16” EHS
90’ ROHN 25G
56’
(399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
91’ CONNECTIONS a re i nc l ud ed when ord er i ng
INCLUDED 900’ 18 18 9 3 Par t No: 25G130R 090
28’ 77’
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
72’ GROUNDING
P/N: 25G130R090 INCLUDED 3 1 3 3 1

100’ TOWER
FDNS
8.3 OR 6.5
TOWER PARTS 25G 25AG2 BPC25G GA25GD BASE ANCHOR
98’
9.0
INCLUDED 9 1 1 3 CB1G AB2
127’
3/16” EHS
100’ ROHN 25G
63’
(399#) GUYS & 3/16EHS BG2142 5/16THH 1/2TBE&J TBSAFETY Al l par ts shown i n tabl e
102’ CONNECTIONS a re i nc l ud ed when ord er i ng
INCLUDED 1000’ 18 18 9 3 Par t No: 25G130R 100
32’ 86’
ANCHORS & GAC3455TOP AGK1GGX BGK3GGX CPC.5/.75 3/4x12PP
80’ GROUNDING
P/N: 25G130R100 INCLUDED 3 1 3 3 1

36 Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
© 2011 ROHN PRODUCTS LLC
GUYED TOWERS - 25G G
PA R T S & A CC E S S O R I E S

8 1/4” 2.00“ O.D. 1’ - 0” 1.66“ O.D. 1’ - 6” 2.25” O.D.


1.87” I.D. 1.38” I.D. 2.08“ I.D. 1’ - 0” 2.25” O.D.
1.25” N.P.T. 2.08“ I.D.
Set Screw 1’ - 3”
9’ - 0” 9’ - 3 1/4” 9’ - 9” 1’ - 4 3/4”
1’ - 3” Set Screw
1’ - 4” 9’ - 3 1/2”

1’-3 3/4”
1’-3 3/4”

TOP SECTION
25AG TOP SECTION TOP SECTION TOP SECTION
COMES WITH TOP BUSHING INSTALLED, 25AG1 25AG2 25AG3
1.31” I.D.

1’ - 1/4” Set Screw


1’ - 5 1/4”
8’ - 3/16” 2.75” O.D.
2.58“ I.D.
8’ - 3 1/2”
1’ - 3 3/4”
1’-3 3/4”

BEARING PLATE
BPL25G TOP PLATE
LONG LEGS PROVIDE EXTRA CLEARANCE
TOP SECTION TOP SECTION FOR INSTALLATION OF EQUIPMENT. APL25G
25AG4 25AG5 BOLTS TO TOP OF STANDARD SECTION. FOR MOUNTING BEACON
HOLE PATTERN FITS TB3 (2” O.D.) AND TB4 OR LIGHTNING ROD.
TOP PLATE HOLE PATTERN IS THE
(3” O.D.) THRUST BEARINGS.
SAME AS BPL25G.

TOP MOUNT
25TDMKD - NO MAST
25TDM2S3KD - 2 3/8” O.D. MAST
25TDM25S3KD - 2 7/8” O.D. MAST 1’- 4”
25TDM3S3KD - 3 1/2” O.D. MAST
25TDM35S3KD - 4” O.D. MAST
MOUNTING TUBE PROVIDED IS 7’ LONG.
BEARING/ACCESSORY SHELF LIGHTNING ROD
BAS25G LRCL
HOLE PATTERN FITS TB3 (2” O.D.) AND 5’ COPPER CLAD, MOUNTS TO APL25G.
TB4 (3” O.D.) THRUST BEARINGS ON
TOP PLATE. ACCESSORY SHELF DRILLED
FOR MOUNTING MANY POPULAR ROTORS.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
37
© 2011 ROHN PRODUCTS LLC
GUYED TOWERS - 25G G
PA R T S & A CC E S S O R I E S

1’

7/8” - 1 1/8” O.D.


Mounting Pipe
1’

FLAT ROOF MOUNT SIDE ARM MOUNT DBS ANTENNA MOUNT


FR25G* UHF25G KY2068A16 - 1.66” O.D.
BOLTS DIRECTLY TO FLAT ROOF SURFACE. FOR UHF & FM ANTENNAS. KY2068A15 - 1.50” O.D.
FACE MOUNT KY2068A2 - 2.38” O.D.
DM25G2 - 2 3/8” O.D. 5’ LONG MOUNTING TUBE PROVIDED IS 3’ LONG.

Adjustable
2.5’ - 3.0’

HEAVY DUTY UNIVERSAL UNIVERSAL EAVE BRACKET


HOUSE BRACKET EB2525G
ADJUSTABLE HOUSE BRACKET HBUTVRO HINGED CONNECTION ALLOWS TOWER
HB25AG 0 - 15” LEG CLAMPS TO REMAIN PERPENDICULAR
ADJUSTABLE TO POSITION TOWER TO GROUND WHILE BOLT DOWN
SIDE ARM BRACKET HB25BG 0 - 24” 18” - 36” FROM WALL. SUPPORTS ROTATE TO LAY FLAT ALONG
SA253UA HB25CG 0 - 36” PITCHED ROOF OR EAVE.
MOUNTING TUBE PROVIDED IS 3’ LONG,
2 - 1/4” O.D.

TORQUE ARM STABILIZER TORQUE BAR


ASSEMBLY TB25D
TA25 OPTIONAL, FOR USE WITH GA25GD. ACCESSORY SHELF
ANTI-TWIST DEVICE LOCATED IN THE REQUIRES (1) 3/8” SHACKLE AS25G
AREA OF ANTENNAS. PROVIDES SIX-WAY FOR EACH BAR. GUY BRACKET FOR MOUNTING MANY POPULAR
GUYING. BOLTS TO TOWER AT ANY GA25GD ROTORS. FIELD DRILLING MAY BE
SECTION JOINT. ATTACHED WITH MOUNTS TO TOWER AT ANY NECESSARY FOR SOME ROTORS.
JOINT BOLTS. MUST BE INSTALLED AS HORIZONTAL BRACE.
SECTIONS ARE JOINED TOGETHER.

* TOWERS MOUNTED ON THESE BASES MUST BE BRACKETED OR GUYED AT ALL TIMES. TEMPORARY STEEL GUYING MAY ALSO BE NECESSARY DURING INSTALLATION AND DISMANTLING.

Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
39
© 2011 ROHN PRODUCTS LLC
G GUYED TOWERS - 25G

PA R T S & A CC E S S O R I E S

Tower
Leg

RP25G

THRUST BEARING TOWER BUSHING


TB3 - SUPPORTS UP TO 2” O.D. MAST. TB50 - 1-1/4” I.D. X 2” O.D. Tower
Leg 90º JOINTS
TB4 - SUPPORTS UP TO 3” O.D. MAST. TB75 - 1-1/2” I.D. X 2” O.D. RP25G CM 2590MM - BOTH ENDS SWAGED
MOUNTS TO BAS25G, BPL25G FOR USE ON 25AG TOP SECTION JOINTS ARE NOT DRILLED WHERE THEY
AND 25AG4. SLIP FIT TO 25G SECTIONS. CAN BE
ROTOR POST FIELD DRILLED OR CUSTOM CONNECTED
1.25” O.D. TO MEET PARTICULAR NEEDS.
1.08” I.D.

90º JOINTS
90º JOINTS 2590FM - ONE END SWAGED,
2590FF - BOTH ENDS OPEN ONE OPEN
JOINTS ARE NOT DRILLED WHERE THEY ANTI-CLIMB PANELS SAFETY RING
JOINTS ARE NOT DRILLED WHERE THEY 25ACL3
SLIP FIT TO 25G SECTIONS. CAN BE SLIP FIT TO 25G SECTIONS. CAN BE SR245
FIELD DRILLED OR CUSTOM CONNECTED FIELD DRILLED OR CUSTOM CONNECTED THREE ANTI-CLIMB PANELS BOLT SNAPS INTO PLACE AT ANY LEVEL.
TO MEET PARTICULAR NEEDS. TO MEET PARTICULAR NEEDS. TO STANDARD TOWER SECTION. NO BOLTS REQUIRED.

CLIMBING HARNESS
TTFBH-4D
JOURNEYMAN HARNESS SAFETY CABLE SYSTEM
TTFBH-C/P ORDERING INFORMATION
PROFESSIONAL HARNESS

TOWER PART
HEIGHT NUMBER
50’ TT05025
100’ TT10025
150’ TT15025
200’ TT20025
ERECTION FIXTURE
EF2545 - 2 1/2” SHEAVE WITH SAFETY CABLE SLIDER AND
WORK PLATFORM CLIMBING HARNESS MUST
WP25G 3/8“ I.D. GROOVE. BE ORDERED SEPARATELY.
NOTE: ERECTION FIXTURES ARE FOR SAFETY CABLE SLIDER
SNAPS INTO PLACE AT ANY LEVEL. LIFTING ONE 10’ SECTION AT A TIME AND WITH CARABINEER
NO BOLTS REQUIRED. ARE NOT INTENDED FOR THE LIFTING OF TT-WG-500-W/SMC
PERSONNEL.

40 Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
© 2011 ROHN PRODUCTS LLC

You might also like