DDR AMERICAS INC.

1090 Fountain Street North, Unit 10


Cambridge, Ontario, Canada N3E 1A3
Tel: 519.650.0420 Fax: 519.650.1709

Submittal Sheet

Model GT 224A
Cast Iron Boiler

Project Name
Project location
Contractor
Engineering Firm
Boiler Representative
Sales Rep. Phone
Date Created

Boiler Model Burner Model


Assembled Burner Included
Relief Valve Fuel Type
Boiler Options Burner Options

Code

Revision
1 Date: 4 Date:

2 Date: 5 Date:

3 Date: 6 Date:

This drawing and the information depicted therein is the property of DDR Americas Inc. Copies are issued in strict confidence and shall not be
reproduced or copied or used as the basis fro the manufacture or sale of products without prior written permission of DDR Americas Inc.
Engineering Submittal Package for GT224A Series
30.39”
[772]

14.96”
[380mm]
27.56”
[700mm]

1 Heating outlet, 1¼” for GT 224A & GT 225A, 1½” for GT 226A to GT 228A GT 224A Combustible & Service Clearances
2 Heating return, 1¼” for GT 224A & GT 225A, 1½” for GT 226A to GT 228A Sides 20 in/500 mm
3 Fill/drain ¾” Rear 20 in/500 mm
4 Boiler vent connection
Front 24 in/600 mm
5 4xM8 on Ø 5.9”/150mm and 4 markings on Ø 6.7”/170mm
Top 34 in/800 mm
6 Precut/predrilled door to fit applied burner
Vent As specified by vent manufacturer
Boiler must not be installed on combustible flooring or pad, do not
install on carpet.

Boiler Specifications
Input (Gas) MBH/kW 173/50.7
Input (Oil) US GPH 1.2
Output (Gas-Oil) MBH/kW 147/43.2
Cast Iron Sections - 4
Flue-way Baffles - 2
Water Capacity USGAL/L 9.5/36
Water Resistance ΔT=18°F Feet of Water (FT)/mbar 0.667/19.952
Water Resistance ΔT=27°F Feet of Water (FT)/mbar 0.297/8.867
Water Resistance ΔT=36°F Feet of Water (FT)/mbar 0.167/4.988
Combustion Chamber Dimensions (Diameter) Inch/mm 12.17/309
Combustion Chamber Dimensions (Depth) Inch/mm 17.6/446
Combustion Chamber Dimensions (Volume) Ft³/m³ 1.165/0.033
ASME MAWP (Water) PSI ASME IV Rating Class 30- (60 psi)
Minimum Relief Valve Capacity MBH 162
Panel (Electrical Connection) V/P/H 120/1/60 <10A
Panel (Maximum Water Temperature) °F/°C 230/110
Panel (Operating Water Temperature Range) °F/°C 86-194/30-90
Chamber Resistance Inch w.c./mbar 0.08/0.2
Gas-Vent Category - I,II-III or IV & Sidewall Vented
Boiler Vent Connection Inch 6
Weight (Dry) LB/kg 481/218