M2 REMOTE MIRROR HEAD


ACTUATOR FIELD REPLACEMENT

NOTE: WEAR SAFETY GLASSES AND GLOVES.

© Lang Mekra North America LLC


101 Tillessen Boulevard – Ridgeway, SC 29130 – USA
414 – M2 REMOTE MIRROR HEAD ACTUATOR FIELD REPLACEMENT

M2 Actuator
Replacement New Components

Actuator 2 per mirror head


p/n 08 414 3000

Direct Connect Plug


08 589 0001

Jumper Cable from old wire harness to new


actuators - p/n 09 414 3000
Jumper Cable needed if converting
from old version to new direct plug
actuators

Retain Components
Screw
p/n 04 040 2201

Stabilizer
p/n 11 414 3300

Rev # 1 Page 2 of 7
414 – M2 REMOTE MIRROR HEAD ACTUATOR FIELD REPLACEMENT

1- After removing the glass carrier plate, remove all 12 screws retaining the actuators in
the mirror housing and disconnect the 3 pin connector to the wire harness.

NOTE: Be sure to review the parts list above and retain all necessary components to
assemble the new actuators.

Main Mirror head –


remove 12 fasteners
as marked

2- After removing the old actuators from the housing, 2 of the mounting posts will need
to be removed with wire cutters flush to the housing surface prior to installing the
new actuators. See picture.

Clip the 2 marked


actuator posts until
the tooling change is
complete.

Rev # 1 Page 3 of 7
414 – M2 REMOTE MIRROR HEAD ACTUATOR FIELD REPLACEMENT

3- Insert the swing pins of the actuators into the shorter arm of the lever joint and then
insert the 2nd actuator into the longer arm of the lever joint.

Longest arm of lever


joint
Swing pin

Shorter arm of lever


joint

4- Obtain 2 white stabilizers (p/n 11 414 3300) and insert them at the extremities of
both actuators (see picture).

This side of the


stabilizer needs to be
upside down

Actuator
Extremity

Rev # 1 Page 4 of 7
414 – M2 REMOTE MIRROR HEAD ACTUATOR FIELD REPLACEMENT

5- If necessary, insert a tie wrap between the short lever joint arm and the Left/Right
actuator (see picture). Then push it under the actuator.

Tie Wrap

6- Put one screw (p/n 04 040 2201) in each 10 posts of both actuators, torque each
screw to 0.7 –1.2 Nm. (IC)

Rev # 1 Page 5 of 7
414 – M2 REMOTE MIRROR HEAD ACTUATOR FIELD REPLACEMENT

7- After the actuators are screwed in place and secure, the direct plug actuator wires will
be inserted as follows:

When connecting the Direct Connect Plug to the actuator, the correct installation will look
like the picture below:

UP/DOWN MOVEMENT
LH – YELLOW 1, BROWN 2
RH – BROWN 1, YELLOW 2

LEFT/RIGHT MOVEMENT
LH – YELLOW 1, ORANGE 2
RH – ORANGE 1, YELLOW 2

After plugging the actuators, be sure to bench test the connections prior to finish
assembling the mirror system and mounting to the truck. This will save time later if
something is connected incorrectly.

Rev # 1 Page 6 of 7
414 – M2 REMOTE MIRROR HEAD ACTUATOR FIELD REPLACEMENT

8- After bench testing the new actuators, secure the excess wires with the tie wrap and
cut off the excess tie wrap.

9- Re-connect the heater circuit and AAT sensor before assembling the glass carrier plate
to the mirror system.