őŖŎőġœŐŖŕŊŏňġŔŌņŕńʼn

SET @ 850 Kpa(g)

LLL 300 mm
NLL 1800 mm
HLL 3300 mm FO
124
OP =385.7 Kpa(g) C-8403
OT=72.7 °C FT SET @ 820 Kpa(g)
dP=14.109kPa 125
LV
dP=306.729 kPa 122
PATH 2 dP=39.234kPa
9.6 m

ŕō
Flow Rate=34078.5 kg/hr dP=20 kPa
6m

OP =397.4 Kpa(g)
Le=89.03 m PATH 1 dP=70 kPa

21.6 m
OT(Bot)=102.5 °C
Flow Rate=141993.8 kg/hr OT(Top)=69.6 °C
Le=126.52 m C-8402
LLL 300 mm
NLL 1800 mm
4" HLL 3300 mm
ŕō
Distributor dP=5.77 kPa
dP=2.053kPa
Le=8.8 m

8m
dP=4.146kPa
XV
121
dP=3.5kPa
10" A 6"
Flow Rate=176072.3 kg/hr EL +0.7 m
Le=55.33 m P-8406A/B
Assumption
1) The pressure drop of pump suction strainer is 3.5 kPa.
2) The elevation of pump centerline above grade will be taken as 0.7m for small pumps(<30 kw).
3) Pump normal flow rate =125.77+37.7(pump min. circulation flow 30% of normal) m3/hr
4) Pump rated flow rate =125.77*1.25+37.7(pump min. circulation flow 30% of normal) Use
m3/hr.
SI Unit for calculation
Le: Equivalent Length
5) The pressure drop of 84-LV-122 is based on BDEP instrument data sheet.