Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Prices as of April 15, 2015. Check Web site for most current prices.

DirectView 1000

DV-1000 $210.00 4-line by 16-character backlit LCD display


Display user-defined messages, even
Overview
Specifications with embedded V-memory values: Each
The DirectView DV-1000 is a small, low- line may contain a maximum of four
DV-1000CBL or
cost operator interface. The DV-1000 Cable Required D4-1000CBL. See the embedded values. Messages are stored
can be directly connected to DL05, following page in CPU variable memory. Therefore, the
DL06, DL105, DL205, D3-350 or DL405 Max. Distance 15 feet from the CPU number of messages is limited only by
CPUs. The DV-1000 is a “ladder logic Connector Phone jack RJ12 available CPU variable memory.
dependent” terminal which relies entirely 150mA @ 5VDC max Display system-defined error messages
on PLC ladder logic to perform its func- Power Consumption (supplied by PLC and user-defined fault messages even
communication port)
tions. The DV‑1000 does not require any in list format: Scroll through errors and
configuration software. Instead, setup NEMA Rating None
messages. Error logs can even show time
is performed through special reserved Agency Approval UL, CUL, CE and date stamps on DL06 family, D2-240,
memory locations inside of the CPU. Storage Temp -4 to 158°F (-20 to 70°C) D2-250-1, D2-260, D3-350, D4-440,
These special memory areas tell the D4-450 CPUs.
Operating Temp 32 to 122°F (0 to 50°C)
DV-1000 which modes to use, and more
importantly, where to get its display data. Humidity 5-95% (non-condensing)
The following functions can be performed Vibration Resistance MIL STD 810C
Method 514.2 Is the DV-1000 right for you?
by the DV-1000:
MIL STD 810C The DV-1000 is best suited for
 iew memory status: Display up to four
V Shock Resistance Method 516.2 displaying information and occasion-
variable address values at a time on a Noise Immunity NEMA (ICS3-304) ally changing setpoint parameters.
single screen. To use the DV-1000 you should be
Atmosphere No corrosive gases
View bit status: Display 32 bits (4 lines of very comfortable with ladder logic
Manufacturer Koyo Electronics
programming. If you’re looking for an
8 bits) or 64 bits (4 lines of 16 bits) at a
time on a single screen. Bit data types can operator control panel, you should
include I/O points, control relays, timer/ Part consider the C-more family of panels.
Price Description
counter and stage bits. Number They are better suited for applications
Change values of memory locations: Up Direct View 1000 Timer/
that require operator interaction as a
to 16 different variable memory values DV-1000 $210.00 Counter access unit for normal part of operation.
Direct LOGIC PLCs Which CPU is best to use with the
can be changed (32 for DL405). Just
move the cursor over the appropriate digit Shielded cable to connect to DV-1000?
DV-1000CBL $19.00 Direct LOGIC PLCs,
The DL05, DL105, DL06, D2-240,
and press the increment (+)/decrement (RS-232C)
(-) keys. D2-250-1, D2-260, D3-350,
Shielded cable to connect to
Units per CPU: Only one DV-1000 per D4-1000CBL $17.00 15-pin port on DL405 PLCs D4-440, and D4-450 have ACON
CPU. (RS232C) instructions that make the DV-1000
easier to work with. The DL105 and
D2-230 have only one communication
port, which can be a limitation in some
cases. The DV-1000 does not work
with D3-330 or D3-340 CPUs, CLICK
controllers or Productivity3000 CPUs.

Book 1 (14.3)
HM-8 Operator Interface 1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.

DV-1000 Dimensions and Installation Company


Information

Control Systems
Installation Clip mount
4.92"
Overview

(124.9mm)
The DV-1000 is designed to snap into a CLICK PLC
rectangular cutout in a control panel or
Do-More
other surface panel. On each side of the PLCs Overview
2.64" Back 2.8"
housing there is a retention clip to keep (67mm) (71mm)
the unit in place after installation. There Do-More H2
PLC
are no provisions for mounting screws,
so if your particular application is subject 5.12" Do-More T1H
Brightness adjustment
to high amounts of vibration, this may be screw (bottom)
(130mm) PLC
a factor in your selection process. The 1.34"
4.94"
(34mm) DirectLOGIC
drawing gives the physical dimensions of (125.5mm) PLCs
the DV-1000 housing.
DirectLOGIC
The panel cut-out dimensions provide Panel cut-out DL05/06
2.65"
necessary clearance for the body of the (67.3mm) Dimensions
unit and allow the outer housing bezel DirectLOGIC
DL105
to cover the edges of the cut-out for a
nice finished appearance. The optimum 1.03" DirectLOGIC
DL205
panel thickness for using the retention (26mm)
clips is 1/16”” to 1/8”. DirectLOGIC
DV-1000CBL DL305
Cabling requirements
6.6 ft./2m DirectLOGIC
Since the DV-1000 only works with the DL405

DL05, DL06, DL105, DL205, D3-350


Productivity
and DL405 CPUs, your cabling choices Controller
Overview
are fairly simple. 6-pin RJ12 connectors
•D V-1000CBL — connects to DL05, DL06, on both ends Productivity
DL105, DL205, D3-350 and D4-450 phone 2000

jack. Productivity
• D4-1000CBL — connects to all DL405 3000
CPU 15-pin ports. Back Universal
Maximum cable length of 15 feet between Field I/O
the DV-1000 and the PLC is recom-
6-pin RJ12 connector Software
mended.
The DV-1000 can be connected to a Use DV-1000CBL cable for connecting to DL05, C-More
DL06, DL105, DL205, D3-350, and D4-450. HMI
DL205 or DL405 DCM, but you have to
build your own cable. C-More Micro
HMI

C-more Micro-Graphic 6.6 ft./2m ViewMarq


Industrial
The C-more Micro-Graphic Panels are a D4-1000CBL Marquees
more enhanced small, low-cost graphic
Shielded cable Other HMI
operator interface that you may want to 6-pin RJ12 connector
consider when selecting a panel. The Communications
C-more Micro-Graphic panels are avail- 15-pin D-shell
connector
able in both a touch screen and non-touch Appendix
Book 1
version. The C-more panels will work with 6-pin RJ12 connector
all DirectLOGIC PLCs and will also work Terms and
Conditions
with many different 3rd party PLCs.

Back

Use D4-1000CBL cable for connecting DV-1000 to DL405,


including D4-450 middle port.

Book 1 (14.3)
www.automationdirect.com/optimates Operator Interface HM-9

You might also like