Analytical Filtration HPLC Br8825en MK
filtration
for HPLC
2
Since our founding, we have participated Expert Products & Services
in the Pharmaceutical and Biotechnological With a catalog of over 300,000 products, our Life
industry with pharmaceutical chemists and Science business offers the most highly-recognized
analysts who address health and science brands in the industry including Supelco®, Sigma-
needs and deliver solutions. Aldrich®, Millipore®, Milli-Q®, SAFC® and BioReliance®.
Our product and services portfolio covers all stages
Our partners from the chemistry and life of the production chain with an end-to-end workflow,
science areas can rely on us to help them supported by world-class customer service.
meet their requirements with the highest
quality standards.
3
Features of our business model
5
HPLC filtration membranes
Selecting the ideal filter begins with understanding filter characteristics. Material, pore
size, flow rate, chemical compatibility, level of extractables, and application should all be
considered when choosing a membrane. We have included a list of membranes commonly
used in HPLC along with their distinguishing features.
F F H H F F
+
C C C
C C C
F F H H F F
n n n
Membrane Nylon
Material Nylon
Membrane Durapore®
Wettability Hydrophilic
Material Polyvinylidene floride (PVDF)
Pore size (µm) 0.2-1.2
Wettability Hydrophilic, Hydrophobic
Porosity % 70-75%
Pore size (µm) 0.1-5
Water flow rate (mL/min/ 8.0-21.5
Water flow rate (mL/ >4 for the 0.1 um and > 208 for cm2) @ 27.5” Hg
min/cm2) @ 27.5” Hg the 5um
Chemical compatibility Compatible with aqueous liquids
Chemical compatibility Compatible with both aqueous and and solvents
organic solvents
Properties General use, good resistance to
Properties High flow rates and throughput, solvents
low extractables, broad chemical
compatibility; hydrophilic PVDF has Applications Particle removal and clarification
very low protein binding property of solvents, particle analysis
Applications Hydrophilic PVDF is used for Products Millex® syringe filters, Millex
particle removal and clarification of for Samplicity® G2 Filteration
aqueous biological samples. System, filter discs
7
What do the membrane product numbers mean?
9
Compatible hardware
500 mL
300 mL
Ordering information
Cat. No. Description Quantity
MCFLX4702 Millicup™-FLEX 47 mm, filtration 10 funnels,
cup, semi-reusable 2 collars, 2 fittings
MCFLX4710 Millicup™-FLEX 47 mm, single 10 funnels,
use filtration cup 10 collars,
10 fittings
11
Glass Microanalysis Filter Holders
Cat. No. Description Membrane diameter Volume
XX1012500 Millipore® glass microanalysis filter holder kit 25 mm, glass frit membrane 25 mm 15
support, 15 mL funnel
XX1012530 Millipore® glass microanalysis filter holder kit 25 mm, stainless steel display 25 mm 15
membrane support, 15 mL funnel
XX1019022 Glass vacuum filter holder 90 mm 90 mm 1L
13
Sample Preparation
Non-sterile Millex® syringe filters
Prepare samples using low extractables Millex syringe filters to
ensure clean baselines and maximize instrument performance for
sensitive analyses like UHPLC, LC-MS, and ion chromatography.
Our world-class manufacturing processes ensure quality Benefits:
and integrity for superior sample filtration.
• Convenient, highest-quality syringe filters for
For best results, choose a filter based in the sensitive instrumental analyses including UHPLC,
following criteria: LC-MS and ion chromatography
• A membrane that is chemically compatible with • Broad chemical compatibility to ensure use with
your sample virtually any sample type
• The recommended pore size for your • Low analyte-binding membranes
analytical method
• The appropriate filter diameter for the sample volume
• Choose an integrated pre-filter (such as Millex®-HPF
filters) for samples with high particulate load.
1. F
ill syringe with 2. C
onnect the syringe 3. H
old the syringe 4. Push the
the solution to to the Millex® vertically with syringe plunger
be filtered. syringe filter. the filter pointing to deliver the
upward and press a filtered solution.
few drops through
Optional: To purge the
the filter. syringe filter and maximize
yield, remove the Millex®
filter from the syringe and
introduce air.
Then, replace the Millex®
filter and push the plunger
to force some air through
the filter.
15
We have a filter for that
Millex® syringe filters for small molecule and protein samples
Hydrophilic PTFE
Protect your results with HPLC-certified Millex® hydrophilic PTFE
syringe filters.
• Millex®-LG and Millex®-LCR filters contain hydrophilic PTFE membranes
and are HPLC-certified for low levels of UV-absorbing extractables.
• Hydrophilic PTFE membranes exhibit low analyte binding and broad
solvent compatibility, enabling filtration of aqueous and organic solvents.
Ordering Information
Choose the best diameter for your sample volume. We recommend our 13 mm Millex® filters for filtration of
1-10 mL samples and our 33 mm Millex® filters for filtration of 10-100 mL samples. These syringe filters have
color coded bands to easily identify the membrane type.
Millex® for
Samplicity® G2
50 100 250 1000 (250 funnels +
Membrane Pore Size Diameter units/pk units/pk units/pk units/pk 250 filters/pk)
PTFE Hydrophilic Millipore® 0.20 µm 13 mm – SLLGX13NL – SLLGX13NK –
Membrane
0.45 µm – SLCRX13NL – SLCRX13NK –
• Lowest extractables SLCRX13TL*
• Light blue band 0.20 µm 33 mm SLLG033NS SLLG033NB SLLG033NK SAMP2LGNB
0.45 µm SLCR033NS – SLCR033NB SLCR033NK SAMP2LCRB
PVDF Durapore® Membrane 0.22 µm 13 mm – SLGVX13NL – SLGVX13NK –
SLGVX13TL*
• Low protein binding
0.45 µm – SLHVX13NL – SLHVX13NK –
• Yellow band
SLHVX13TL*
0.22 µm 33 mm SLGV033NS – SLGV033NB SLGV033NK SAMP2GVNB
0.45 µm SLHV033NS – SLHV033NB SLHV033NK SAMP2HVNB
PTFE Hydrophobic Fluoropore™ 0.20 µm 13 mm – SLFGX13NL – SLFGX13NK –
Membrane SLFGX13TL*
• Excellent solvent resistance 0.45 µm – SLFHX13NL – SLFHX13NK –
SLFHX13TL*
• Red band
0.20 µm 33 mm SLFG033NS – SLFG033NB SLFG033NK –
0.45 µm SLFH033NS – SLFH033NB SLFH033NK –
17
PES Express® Membranes
Fast flow rate for aqueous samples with PES Millipore
Express® Membrane
When filtering large volumes or heavily contaminated solutions, membrane
pores can clog, slowing the filtration rate. For these processes, Millipore
Express® polyethersulfone (PES) membranes offer the largest filtration
capacity. These filters have an asymmetric pore structure: the pores are
larger at the top, where filtration starts. The pore size then decreases from
the top face of the filter to the bottom, where the pore size is small enough
to retain bacteria (0.22 μm). This asymmetric pore design traps large
particles at the top so that they do not clog the tight pores on the retentive
side of the membrane, enhancing the filtration capacity and useful life of
the filter.
Millex® for
Pore Samplicity® G2
Diameter Size 50 100 250 1000 (250 funnels +
Membrane (mm) (µm) units/pk units/pk units/pk units/pk 250 filters/pk)
PES Millipore Express® 13 0.22 – SLGPX13NL – SLGPX13NK –
Membrane
0.45 – SLHPX13NL – SLHPX13NK –
• Fastest liquid flow rate
33 0.22 SLGP033NS – SLGP033NB SLGP033NK SAMP2GPNB
• Green band 0.45 SLHP033NS – SLHP033NB SLHP033NK SAMP2HPNB
Membrane Membrane pore size (µm) Diameter Pack Size Cat. No.
Hydrophilic PTFE 100 SLLGX13NL
13 mm
1000 SLLGX13NK
0.20 µm 50 SLLG033NS
33 mm 250 SLLG033NB
1000 SLLG033NK
100 SLCRX13NL
13 mm SLCRX13TL
1000 SLCRX13NK
0.45 µm
50 SLCR033NS
33 mm 250 SLCR033NB
1000 SLCR033NK
Nylon 100 SLGNX13NL
13 mm 100 SLGNX13TL
1000 SLGNX13NK
0.20 µm
50 SLGN033NS
33 mm 250 SLGN033NB
1000 SLGN033NK
100 SLHNX13NL
13 mm 100 SLHNX13TL
1000 SLHNX13NK
0.45 µm
50 SLHN033NS
33 mm 250 SLHN033NB
1000 SLHN033NK
19
Does your hand get sore when filtering
complex samples?
The solution: HPF Millex® syringe filters
A filtration tool tailored to your needs
Use our Millex®-HPF syringe filters, specially designed • Two to four times greater throughput than syringe
for samples with high particle levels. HPF Millex® filters without prefilters
syringe filters include two different media: a graduated
• For manual or automated use
glass fiber prefilter to remove larger particles and a
0.20 or 0.45 µm membrane filter for fine filtration. This • Low-extractable polyethylene housing
combination of media provides significantly greater
throughput than standard filters without prefiltration
media, especially when filtering particle-laden solutions.
21
Automation Compatible Filter Units
Features
• Domed housing ensures reliable delivery of filters
• Pressure-resistant housing resists bursting
• Luer-Lok® connection optimized for precise alignment and fit
• Available in either bulk or delivery tubes for use with automated
filter-changing systems
23
Merck KGaA
Frankfurter Strasse 250
64293 Darmstadt, Germany
MerckMillipore.com
To place an order or receive technical assistance in Europe, please call Customer Service:
France: 0825 045 645 Spain: 901 516 645 Option 1
Germany: 069 86798021 Switzerland: 0848 645 645
Italy: 848 845 645 United Kingdom: 0870 900 4645
For other countries across Europe, please call: +44 (0) 115 943 0840
Or visit: MerckMillipore.com/offices
For Technical Service visit:MerckMillipore.com/techservice
© 2022 Merck KGaA, Darmstadt, Germany and/or its affiliates. All Rights Reserved. Merck, the vibrant M, Millipore,
Millex, Samplicity, Millipore Express, Fluoropore, Omnipore, Millicup-FLEX, and Durapore are trademarks
of Merck KGaA, Darmstadt, Germany or its affiliates. All other trademarks are the property of their
respective owners. Detailed information on trademarks is available via publicly accessible resources.