Project Completion Databook

General Inspection

PGC

WO №: 2626 • PO №: 4504180804 • Date: 21-Feb-2023


Approver Name & Qualification Approver Signature†
Edgar Santos de Souza
SNT-TC-1A / CFT 05568356700
†Digitally Signed

Av. José Silva de Azevedo Neto, 200 – Bl 3 – Térreo – Barra da Tijuca, Rio de Janeiro - RJ, Brazil – RJ, 22775-056 Tel: +55 21 3437-4645
Av. Prefeito Aristeu Fereira da Silva, 2829, Vale Encantado, Macaé – RJ, Brazil – 27930-070 Tel: +55 21 3437-4645
Calle 55 sin numero, Colonia San Carlos, Ciudad del Carmen, Campeche, México – 24116 Tel: +52 (938) 286 5291
Rua Abranches Ferrão, 23, 3º Andar, Escritório 3G, Laranjeiras, São Domingos de Benfica, Lisboa, Portugal – 1600-995 Tel: +354 9650-26467
21625 Rhodes Rd, Spring, TX 77388, United States

www.qualitechirm.com
RP-QT-135 Rev. 4 Quality for Safety
 

SECTION 01 —  EXECUTIVE SUMMARY REPORT

SECTION 02 —  TOP DRIVE REPROVED REPORTS

SECTION 03 —  DRILLING TOOLS REPROVED REPORTS

SECTION 04 —  COMPANY CERTIFICATES

www.qualitechirm.com
RP-QT-135 Rev. 4 Quality for Safety
 

Executive Summary Report

Client: Equinor
Installation: PGC
Purchase Order: 4504180804
Project: General Inspection
Qualitech WO: 2626
Technicians Onboard: Renan Santos, Tito Fabrin
Project Duration: 29-Jan-2023 to 16-Mar-2023

Project

Qualitech was contracted by Equinor to carry out an General NDT inspections onboard of the
Peregrino Charlie to ensure that all equipment inspected is free from any defect before any further
use / test in service in compliance with the all international and nacional standards and acceptance
criterias specified in the inspection reports of each equipment.

Project Development

During the period onboard, the equipment’s below were inspected in according with the relevant
standards specified in the inspection reports of each equipment that the items are fit and safe for
use.

Summary of Defective Items

All defective items have been clearly reported in the individual report of each equipment report of this
Project Completion Databook.

Additional Work Scope

No additional workscope was requested during the time onboard.

Outstanding Work Scope

All the work scope scheduled has been completed.

Qualitech would like to take this opportunity to thank Equinor and the crew of PGC for their co-
operation and assistance during this project.

www.qualitechirm.com
RP-QT-127 Rev. 3 Quality for Safety Page 1
Executive Summary Report

Signed on behalf of Qualitech†

Renan Santos
SNT-TC-1A / CFT 2009560418
Date: 21-Feb-2023
†Digitally Signed

Signed on behalf of Equinor

Date:

www.qualitechirm.com
RP-QT-127 Rev. 3 Quality for Safety Page 2
 

TOP DRIVE REPROVED REPORTS

www.qualitechirm.com
Quality for Safety
 

Magnetic Particle Inspection Report


Identification
Client Equinor Installation PGC Report Number MP-2626-379-4
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Magnetization
Technique Yoke pull 10lbs Equipment Type Electromagnetic Yoke Serial Number QT24967
Current Flow Alternating Voltage 220 V Magnetization Longitudinal
Pole Spacing 4" - 6" White Light Intensity 1200 lux UV Light Intensity N/A
Flux Indicator Burmah Strip Demagnetization Required No    

Consumable
Method Wet Colour Visible FL/Sample AT Visible: 1.2ml - 2.4ml / 100ml Black Light SN N/A
Particle Type 7C BLACK Manufacturer Magnaflux Batch Number 2101009718
Contrast Type WCP-2 Manufacturer Magnaflux Batch Number 2101009620
Antifoaming Type WA-4 Manufacturer Magnaflux Batch Number 2101009595

Equipment
Equipment Description Top Drive System Knuckles Serial Number 7873-1 GOT 120052-1
Size N/A Quantity 2 Temperature 29 °c
Acceptance Criteria EN-1369 Acceptance Level N/A Manufacturer Cameron
Material Carbon Steel Surface Condition Clean Number of Repairs N/A
Welding Process Used N/A Post Weld Heat Treatment No Reference Drawing N/A

Pictures

100% MPI in accessible areas. Areas found circular discontinuities

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 1
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-4
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Area with many discontinuities all dimensioned. Indications with varied but dimensioned areas.

Indications with varied but dimensioned areas Indications with varied but dimensioned areas

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 2
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-4
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Indications with varied but dimensioned areas Indications with varied but dimensioned areas

Indications with varied but dimensioned areas Indications with varied but dimensioned areas.

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 3
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-4
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Indications with varied but dimensioned areas. Indications with varied but dimensioned areas.

Indications with varied but dimensioned areas. Indications with varied but dimensioned areas.

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 4
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-4
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Indications with varied but dimensioned areas. Indications with varied but dimensioned areas.

Indications with varied but dimensioned areas. Indications with varied but dimensioned areas.

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 5
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-4
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Indications with varied but dimensioned areas. Indications with varied but dimensioned areas.

Indications with varied but dimensioned areas. Indications with varied but dimensioned areas.

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 6
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-4
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Indications with varied but dimensioned areas. Indications with varied but dimensioned areas.

Comments
Area Inspected: As per client request a visual and magnetic particle inspection was carried out on 100% of the accessible critical and stress areas of the
Top Drive System Knuckles. Equipment has several circular discontinuities throughout its structure, many areas appear as if it were a weld joint that has
been repaired.

Result: Defects were found at the time of inspection.

Conclusion: Refer to manufacturer guidelines for further advice.

Recommendations: Remove from service.

Inspector Inspector Signature† Inspection Date Approver Approver Signature†


Name & Qualification Name & Qualification
Renan Soares dos santos 09-Feb-2023 Luiz Felipe Leitão Jorge
SNT-TC-1A Quality Assurance
†Digitally Signed

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 7
 

Magnetic Particle Inspection Report


Identification
Client Equinor Installation PGC Report Number MP-2626-379-5
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Magnetization
Technique Yoke pull 10lbs Equipment Type Electromagnetic Yoke Serial Number QT24967
Current Flow Alternating Voltage 220 V Magnetization Longitudinal
Pole Spacing 4" - 6" White Light Intensity 1200 lux UV Light Intensity N/A
Flux Indicator Burmah Strip Demagnetization Required No    

Consumable
Method Wet Colour Visible FL/Sample AT Visible: 1.2ml - 2.4ml / 100ml Black Light SN N/A
Particle Type 7C BLACK Manufacturer Magnaflux Batch Number 2101009718
Contrast Type WCP-2 Manufacturer Magnaflux Batch Number 2101009620
Antifoaming Type WA-4 Manufacturer Magnaflux Batch Number 2101009595

Equipment
Equipment Description Top Drive System Knuckles Serial Number 7873-2 GOT 120052-2
Size N/A Quantity 2 Temperature 29 °c
Acceptance Criteria EN-1369 Acceptance Level N/A Manufacturer Cameron
Material Carbon Steel Surface Condition Clean Number of Repairs N/A
Welding Process Used N/A Post Weld Heat Treatment No Reference Drawing N/A

Pictures

100% MPI. Discontinuity identification area

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 1
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-5
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Area presents dimensioned circular discontinuities. Area presents dimensioned circular discontinuities.

Area presents dimensioned circular discontinuities. Area presents dimensioned circular discontinuities.

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 2
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-5
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Area presents dimensioned circular discontinuities. Area presents dimensioned circular discontinuities.

Area presents dimensioned circular discontinuities. Area presents dimensioned circular discontinuities.

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 3
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-5
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Area presents dimensioned circular discontinuities. Area presents dimensioned circular discontinuities.

Area presents dimensioned circular discontinuities. Area presents dimensioned circular discontinuities.

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 4
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-5
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Area presents dimensioned circular discontinuities. Area presents dimensioned circular discontinuities.

100% MPI. Discontinuity identification area

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 5
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-5
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Area presents dimensioned circular discontinuities. Area presents dimensioned circular discontinuities.

Area presents dimensioned circular discontinuities. Area presents dimensioned circular discontinuities.

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 6
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-5
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Area presents dimensioned circular discontinuities. Area presents dimensioned circular discontinuities.

Area presents dimensioned circular discontinuities. Area presents dimensioned circular discontinuities.

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 7
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-5
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Area presents dimensioned circular discontinuities.

Comments
Area Inspected: As per client request a visual and magnetic particle inspection was carried out on 100% of the accessible critical and stress areas of the
Top Drive System Knuckles. Equipment has several circular discontinuities throughout its structure, many areas appear as if it were a weld joint that has
been repaired.

Result: Defects were found at the time of inspection.

Conclusion: Refer to manufacturer guidelines for further advice.

Recommendations: Remove from service.

Inspector Inspector Signature† Inspection Date Approver Approver Signature†


Name & Qualification Name & Qualification
Renan Soares dos santos 09-Feb-2023 Luiz Felipe Leitão Jorge
SNT-TC-1A Quality Assurance
†Digitally Signed

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 8
 

Ultrasonic Inspection Report


Identification
Client Equinor Installation PGC Report Number UL-2626-400-3
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-034 Standard API RP 8B Purchase Order N/A

Test Equipment
Test Equipment Manufacturer Mitech Model MFD 350B Model MFD 350B Serial Number 3D42101A

Configuration
Transducer Calibration Record
Type Manufacturer Model Serial Number Dimensions Real Angle Freq. Ref. Block Ref.level “b” Increase Var.Gain
Straight Beam ENDVALE MDC 10 051920 10 mm 0 degrees 10 khz V1 And V2 55 db 6 db 61 db
Angle ENDVALE MZA 45-4 3D65311 8 mm 45.2 degrees 4 khz V1 And V2 44 db 6 db 50 db
Angle ENDVALE MZA60-4 28051911 8 mm 61.5 degrees 4 khz V1 And V2 55.5 db 6 db 61.5 db
Angle ENDVALE MZA70-4 28051939 8 mm 70.5 degrees 4 khz V1 And V2 53 db 6 db 59 db

Equipment
Equipment Description Top Drive System Shoulder Serial Number N/A
Size N/A Quantity 1 Temperature 31 °c
Acceptance Criteria API RP 4F Acceptance Level N/A Manufacturer N/A
Material Carbon Steel Surface Condition Clean Number of Repairs 0
Welding Process Used N/A Post Weld Heat Treatment No Reference Drawing N/A

Pictures

Local inspection Local inspection

Comments
Area Inspected: As per client request a visual and ultrasonic inspection was carried out on 100% of the accessible critical and stress areas of the Top
Drive System Shoulder. Ultrasound was requested for dimensioning the crack where it was already disapproved by the magnetic particle test. We were
trying to remove the crack with grinding where it remained, other particle tests were carried out remaining with the same result. Finally, we closed the
tests because the procedures used for the Ultrasound inspection were no longer in agreement because could be masking the test and could generate
false indications. (Swept surface was no longer up to standards.).

Result: Defects were found at the time of inspection.

Conclusion: Refer to manufacturer guidelines for further advice.

Recommendations: Remove from service.

www.qualitechirm.com
RP-QT-241 Rev. 5 Quality for Safety Page 1
Ultrasonic Inspection Report
Identification
Client Equinor Installation PGC Report Number UL-2626-400-3
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-034 Standard API RP 8B Purchase Order N/A

Inspector Inspector Signature† Inspection Date Approver Approver Signature†


Name & Qualification Name & Qualification
Marcelo Broseghini 05-Feb-2023 Luiz Felipe Leitão Jorge
SNQC 15247 US-N2-S2.1 Quality Assurance
†Digitally Signed

www.qualitechirm.com
RP-QT-241 Rev. 5 Quality for Safety Page 2
 

Magnetic Particle Inspection Report


Identification
Client Equinor Installation PGC Report Number MP-2626-379-3
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard EN-3069 Purchase Order N/A

Magnetization
Technique Yoke pull 10lbs Equipment Type Electromagnetic Yoke Serial Number QT-24967
Current Flow Alternating Voltage 220 V Magnetization Longitudinal
Pole Spacing 4" - 6" White Light Intensity 1100 lux UV Light Intensity N/A
Flux Indicator Berthold Demagnetization Required No    

Consumable
Method Wet Fluorescent FL/Sample AT UV: 0.1ml - 0.4ml / 100ml Black Light SN QT-28355
Particle Type 14A Manufacturer Magnaflux Batch Number 2101009718
Antifoaming Type WA-4 Manufacturer Magnaflux Batch Number 2101009595

Equipment
Equipment Description Top Drive System (Solid Body Elevator)-NEW Serial Number 4487 STG2012-103
Size N/A Quantity 1 Temperature 29 °c
Acceptance Criteria ASME B 31.1 Acceptance Level N/A Manufacturer Cameron
Material Carbon Steel Surface Condition Brushed Number of Repairs N/A
Welding Process Used N/A Post Weld Heat Treatment No Reference Drawing N/A

Pictures

100% of the critical area requested by the client Cracks were found on this area

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 1
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-3
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard EN-3069 Purchase Order N/A

Longitudinal cracks were found on this area with 90mm of lenght Longitudinal cracks were found on this area with 30mm of lenght

Circular cracks were found 90mm x 30mm The red circled indicated where the area with the crack concentration

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 2
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-3
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard EN-3069 Purchase Order N/A

Its appear that the equipment was repaired in many placed,. The circle These circles indicated that was filled by weldment
cracks can indicated the places that was filled by weldment.

The circles indicated that were filled by weldment 24mm and 26mm of Tongitudinal crack with 45mm of length
length

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 3
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-3
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard EN-3069 Purchase Order N/A

The circles indicated that were the cracks were found More circle crack with 37mm x 18mm of length

The circles indicated were the cracks were found Cracks found 37mm and 20mm of lenght

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 4
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-3
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard EN-3069 Purchase Order N/A

Circle cracks found 31mm x 30mm of length

Comments
Area Inspected: As per client request a visual and magnetic particle inspection was carried out on 100% of the accessible critical and stress areas of the
Top Drive System (Solid Body Elevator)-NEW. Several longitudinal and circular discontinuities were found, and the circular ones appear as if there had
already been a repair in place in the past, where the circular indications represent the failure of fusion with the base material during the repair.

Result: Defects were found at the time of inspection.

Conclusion: Refer to manufacturer guidelines for further advice.

Recommendations: Remove from service.

Inspector Inspector Signature† Inspection Date Approver Approver Signature†


Name & Qualification Name & Qualification
Renan Soares dos santos 09-Feb-2023 Gabriel Reis
SNT-TC-1A Project Coordinator | Quality
Control
†Digitally Signed

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 5
 

Magnetic Particle Inspection Report


Identification
Client Equinor Installation PGC Report Number MP-2626-379-2
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Magnetization
Technique Yoke pull 10lbs Equipment Type Electromagnetic Yoke Serial Number QT24967
Current Flow Alternating Voltage 220 V Magnetization Longitudinal
Pole Spacing 4" - 6" White Light Intensity 1200 lux UV Light Intensity N/A
Flux Indicator Burmah Strip Demagnetization Required No    

Consumable
Method Wet Colour Visible FL/Sample AT Visible: 1.2ml - 2.4ml / 100ml Black Light SN N/A
Particle Type 7C BLACK Manufacturer Magnaflux Batch Number 2101009718
Contrast Type WCP-2 Manufacturer Magnaflux Batch Number 2101009620
Antifoaming Type WA-4 Manufacturer Magnaflux Batch Number 2101009595

Equipment
Equipment Description knuckles Link Serial Number 7873-1
Size N/A Quantity 2 Temperature 29 °c
Acceptance Criteria EN-1369 Acceptance Level N/A Manufacturer Cameron
Material Carbon Steel Surface Condition Clean Number of Repairs N/A
Welding Process Used N/A Post Weld Heat Treatment No Reference Drawing N/A

Pictures

100% MPI. 100% MPI.

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 1
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-2
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Crack Crack

Crack Crack

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 2
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-2
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Crack Crack

Crack Crack

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 3
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-2
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Crack Crack

Crack Crack

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 4
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-2
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Crack

Comments
Area Inspected: As per client request a visual and magnetic particle inspection was carried out on 100% of the accessible critical and stress areas of the
knuckles Link. Equipment has several cracks in the body, circular and longitudinal cracks, as if there was filling in the area.

Result: Defects were found at the time of inspection.

Conclusion: Refer to manufacturer guidelines for further advice.

Recommendations: Remove from service.

Inspector Inspector Signature† Inspection Date Approver Approver Signature†


Name & Qualification Name & Qualification
Renan Soares dos santos 08-Feb-2023 Luiz Felipe Leitão Jorge
SNT-TC-1A Quality Assurance
†Digitally Signed

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 5
 

Ultrasonic Inspection Report


Identification
Client Equinor Installation PGC Report Number UL-2626-379-1
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-034 Standard API RP 8B Cat III Purchase Order N/A

Test Equipment
Test Equipment Manufacturer Mitech Model MFD 350B Model SIUI SMARTOR Serial Number M06320220066R

Configuration
Transducer Calibration Record
Type Manufacturer Model Serial Number Dimensions Real Angle Freq. Ref. Block Ref.level “b” Increase Var.Gain
Straight Beam SIUI RP4-10L 82100175R 10 mm 0 degrees 10 khz V1 And V2 55 db 6 db 45 db
Angle SIUI AFN4-89 02124018R 8 mm 45.2 degrees 4 khz V1 And V2 44 db 6 db 48 db
Angle SIUI AFN4-89-60L 02216713R 8 mm 61.5 degrees 4 khz V1 And V2 55.5 db 6 db 54 db
Angle SIUI AFN4-89-70L 02202539R 8 mm 70.5 degrees 4 khz V1 And V2 53 db 6 db 59 db

Equipment
Equipment Description Top Drive System (Solid Body Elevator)-NEW Serial Number 4487 STG 2012-103
Size N/A Quantity 1 Temperature 31 °c
Acceptance Criteria ASME Sec V Acceptance Level N/A Manufacturer Cameron
Material Carbon Steel Surface Condition Brushed Number of Repairs 0
Welding Process Used N/A Post Weld Heat Treatment No Reference Drawing N/A

Pictures

Area inspected by ultrassonic report. Additional inspection carried after The irregular surface indicated that the equipment was grinded on the past.
many craks found during the MPI inspection Ths type of surface dont allow the use of the UT probe in an correct way to
check the cracks depth

www.qualitechirm.com
RP-QT-241 Rev. 5 Quality for Safety Page 1
Ultrasonic Inspection Report
Identification
Client Equinor Installation PGC Report Number UL-2626-379-1
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-034 Standard API RP 8B Cat III Purchase Order N/A

Is was found a crack with 10,1mm of depth Is was found a crack with 13,86mm of depth

Comments
Area Inspected: As per client request a visual and ultrasonic inspection was carried out on 100% of the accessible critical and stress areas of the Top
Drive System (Solid Body Elevator)-NEW. Crack depths from 10.1 to 13.86 mm were found, and the area of inspection does not have a flat surface for a
accurate test,due to the surface roughing found after cleaning, making it impossible to have a test accuracy due to the difficult to probe coupling on the
surface.

Result: Defects were found at the time of inspection.

Conclusion: Refer to manufacturer guidelines for further advice.

Recommendations: Remove from service.

Inspector Inspector Signature† Inspection Date Approver Approver Signature†


Name & Qualification Name & Qualification
Renan Soares dos santos 09-Feb-2023 Gabriel Reis
SNT-TC-1A Project Coordinator | Quality
Control
†Digitally Signed

www.qualitechirm.com
RP-QT-241 Rev. 5 Quality for Safety Page 2
 

Magnetic Particle Inspection Report


Identification
Client Equinor Installation PGC Report Number MP-2626-110-1
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard EN-3069 Purchase Order N/A

Magnetization
Technique Yoke pull 10lbs Equipment Type Electromagnetic Yoke Serial Number QT-24967
Current Flow Alternating Voltage 220 V Magnetization Longitudinal
Pole Spacing 4" - 6" White Light Intensity 10 lux UV Light Intensity 1400 µw / cm²
Flux Indicator Berthold Demagnetization Required No    

Consumable
Method Wet Fluorescent FL/Sample AT UV: 0.1ml - 0.4ml / 100ml Black Light SN QT-28355
Particle Type 14A Manufacturer Magnaflux Batch Number 2101009718
Antifoaming Type WA-4 Manufacturer Magnaflux Batch Number 2101009595

Equipment
Equipment Description Top Drive System (Solid Body Elevator) Serial Number N\A
Size N/A Quantity 1 Temperature 29 °c
Acceptance Criteria ASME B 31.1 Acceptance Level N/A Manufacturer Cameron
Material Carbon Steel Surface Condition Clean Number of Repairs N/A
Welding Process Used N/A Post Weld Heat Treatment No Reference Drawing N/A

Pictures

Crack found. Crack found after dy grinder.

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 1
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-110-1
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard EN-3069 Purchase Order N/A

Crack found after dy grinder. Crack found after dy grinder.

Crack found Cracks founds

Comments
Area Inspected: As per client request a visual and magnetic particle inspection was carried out on 100% of the accessible critical and stress areas of the
Top Drive System (Solid Body Elevator). After the crack was found on the TDS, the inspection results were passed to the customer. The SLB base
requested that a roughing process be performed to find the crack depth by tracing it with the aid of MPI and UT. During the process, the unconformities
were visibly increasing in size on magnetic particle inspection (see photo). During the second-to-last cleaning, the crack decreased significantly, but on
the last inspection, it increased again significantly. Due to this fact it was decided together with the aboard SLB team to stop the grinding process until a
technical opinion from the owner and manufacturer of the equipment was obtained.

Result: Defects were found at the time of inspection.

Conclusion: Refer to manufacturer guidelines for further advice.

Recommendations: Remove from service.

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 2
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-110-1
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard EN-3069 Purchase Order N/A

Inspector Inspector Signature† Inspection Date Approver Approver Signature†


Name & Qualification Name & Qualification
Tito Fabrin 04-Feb-2023 Thiago Vasconcelos
SNT-TC-1A Quality Assurance / Quality
Control
†Digitally Signed

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 3
 

Visual Survey Inspection Report


Identification
Client Equinor Installation PGC Report Number VS-2626-110-1
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard EN-1369 Purchase Order N/A

Equipment
Equipment Description Top Drive Sistem
Serial Number N/A
Details N/A
Corrective Action N/A

Pictures

TDS shoulder dimension TDS shoulder dimension.

Crack 1: 5,5mm width x 50mm height Crack 1: Zoomed out

www.qualitechirm.com
RP-QT-017 Rev. 4 Quality for Safety Page 1
Visual Survey Inspection Report
Identification
Client Equinor Installation PGC Report Number VS-2626-110-1
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard EN-1369 Purchase Order N/A

Comments
Area Inspected: As per client request a visual survey inspection was carried out on 100% of the accessible critical and stress areas of the Top Drive
Sistem. As requested by the customer, the Qualitech team inspected the Top Drive Sistem. During the inspection a crack was found.( 5,5mm width x
50mm height ).

Result: Defects were found at the time of inspection.

Conclusion: Refer to manufacturer guidelines for further advice.

Recommendations: Remove from service.

Inspector Inspector Signature† Inspection Date Approver Approver Signature†


Name & Qualification Name & Qualification
Tito Fabrin 31-Jan-2023 Thiago Vasconcelos
SNT-TC-1A Quality Assurance / Quality
Control
†Digitally Signed

www.qualitechirm.com
RP-QT-017 Rev. 4 Quality for Safety Page 2
 

Magnetic Particle Inspection Report


Identification
Client Equinor Installation PGC Report Number MP-2626-379-1
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Magnetization
Technique Yoke pull 10lbs Equipment Type Electromagnetic Yoke Serial Number QT24967
Current Flow Alternating Voltage 220 V Magnetization Longitudinal
Pole Spacing 4" - 6" White Light Intensity 1200 lux UV Light Intensity N/A
Flux Indicator Burmah Strip Demagnetization Required No    

Consumable
Method Wet Colour Visible FL/Sample AT Visible: 1.2ml - 2.4ml / 100ml Black Light SN N/A
Particle Type 7C BLACK Manufacturer Magnaflux Batch Number 2101009718
Contrast Type WCP-2 Manufacturer Magnaflux Batch Number 2101009620
Antifoaming Type WA-4 Manufacturer Magnaflux Batch Number 2101009595

Equipment
Equipment Description Solid Body Elevator Serial Number N/A
Size N/A Quantity 2 Temperature 29 °c
Acceptance Criteria EN-1369 Acceptance Level N/A Manufacturer Cameron
Material Carbon Steel Surface Condition Clean Number of Repairs N/A
Welding Process Used N/A Post Weld Heat Treatment No Reference Drawing N/A

Pictures

MPI MPI

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 1
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-1
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Crack Crack

Crack Crack

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 2
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-1
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Crack

Comments
Area Inspected: As per client request a visual and magnetic particle inspection was carried out on 100% of the accessible critical and stress areas of the
Solid Body Elevator. Equipment has several cracks in the body, circular and longitudinal cracks, as if there was filling in the area.

Result: Defects were found at the time of inspection.

Conclusion: Refer to manufacturer guidelines for further advice.

Recommendations: Remove from service.

Inspector Inspector Signature† Inspection Date Approver Approver Signature†


Name & Qualification Name & Qualification
Renan Soares dos santos 08-Feb-2023 Luiz Felipe Leitão Jorge
SNT-TC-1A Quality Assurance
†Digitally Signed

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 3
 

Magnetic Particle Inspection Report


Identification
Client Equinor Installation PGC Report Number MP-2626-110-2
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Magnetization
Technique Yoke pull 10lbs Equipment Type Electromagnetic Yoke Serial Number QT24967
Current Flow Alternating Voltage 220 V Magnetization Longitudinal
Pole Spacing 4" - 6" White Light Intensity 1200 lux UV Light Intensity N/A
Flux Indicator Burmah Strip Demagnetization Required No    

Consumable
Method Wet Colour Visible FL/Sample AT Visible: 1.2ml - 2.4ml / 100ml Black Light SN N/A
Particle Type 7C BLACK Manufacturer Magnaflux Batch Number 2101009718
Contrast Type WCP-2 Manufacturer Magnaflux Batch Number 2101009620
Antifoaming Type WA-4 Manufacturer Magnaflux Batch Number 2101009595

Equipment
Equipment Description Top Drive System Knuckles Serial Number N/A
Size N/A Quantity 2 Temperature 29 °c
Acceptance Criteria API RB 4F Acceptance Level N/A Manufacturer Cameron
Material Carbon Steel Surface Condition Clean Number of Repairs N/A
Welding Process Used N/A Post Weld Heat Treatment No Reference Drawing N/A

Pictures

Part contrasted. Crack found. (Nonlinear Crack Grouping)

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 1
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-110-2
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Crack found. Crack found.

Crack found.

Comments
Area Inspected: As per client request a visual and magnetic particle inspection was carried out on 100% of the accessible critical and stress areas of the
Top Drive System Knuckles.

Result: Defects were found at the time of inspection.

Conclusion: Refer to manufacturer guidelines for further advice.

Recommendations: Remove from service.

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 2
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-110-2
Client Work Order N/A Qualitech WO WO-2626 SFI Code Top Drive
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Inspector Inspector Signature† Inspection Date Approver Approver Signature†


Name & Qualification Name & Qualification
Tito Fabrin 31-Jan-2023 Luiz Felipe Leitão Jorge
SNT-TC-1A Quality Assurance
†Digitally Signed

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 3
 

DRILLING TOOLS REPROVED REPORTS

www.qualitechirm.com
Quality for Safety
 

Magnetic Particle Inspection Report


Identification
Client Equinor Installation PGC Report Number MP-2626-418-23
Client Work Order N/A Qualitech WO WO-2626 SFI Code DHT
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Magnetization
Technique Yoke pull 10lbs Equipment Type Electromagnetic Yoke Serial Number QT24967
Current Flow Alternating Voltage 220 V Magnetization Longitudinal
Pole Spacing 4" - 6" White Light Intensity 1200 lux UV Light Intensity N/A
Flux Indicator Burmah Strip Demagnetization Required No    

Consumable
Method Wet Colour Visible FL/Sample AT Visible: 1.2ml - 2.4ml / 100ml Black Light SN N/A
Particle Type 7C BLACK Manufacturer Magnaflux Batch Number 2101009718
Contrast Type WCP-2 Manufacturer Magnaflux Batch Number 2101009620
Antifoaming Type WA-4 Manufacturer Magnaflux Batch Number 2101009595

Equipment
Equipment Description Bushing Serial Number 90648
Size N/A Quantity 1 Temperature 29 °c
Acceptance Criteria EN-1369 Acceptance Level N/A Manufacturer N/A
Material Carbon Steel Surface Condition Clean Number of Repairs N/A
Welding Process Used N/A Post Weld Heat Treatment No Reference Drawing N/A

Pictures

Before inspection Before inspection

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 1
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-418-23
Client Work Order N/A Qualitech WO WO-2626 SFI Code DHT
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

After inspection Crack found

Crack found Grouping crack

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 2
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-418-23
Client Work Order N/A Qualitech WO WO-2626 SFI Code DHT
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Grouping crack After inspection

Crack found Grouping crack

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 3
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-418-23
Client Work Order N/A Qualitech WO WO-2626 SFI Code DHT
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Crack measurement After inspection

Grouping crack Grouping crack

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 4
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-418-23
Client Work Order N/A Qualitech WO WO-2626 SFI Code DHT
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Measurement Measurement

After inspection After inspection

Comments
Area Inspected: As per client request a visual and magnetic particle inspection was carried out on 100% of the accessible critical and stress areas of the
Bushing . Cracks in body and support handles.

Result: Defects were found at the time of inspection.

Conclusion: Refer to manufacturer guidelines for further advice.

Recommendations: Remove from service.

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 5
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-418-23
Client Work Order N/A Qualitech WO WO-2626 SFI Code DHT
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Inspector Inspector Signature† Inspection Date Approver Approver Signature†


Name & Qualification Name & Qualification
Luis Silva 04-Feb-2023 Luiz Felipe Leitão Jorge
SNT-TC-1A Quality Assurance
†Digitally Signed

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 6
 

Magnetic Particle Inspection Report


Identification
Client Equinor Installation PGC Report Number MP-2626-110-3
Client Work Order N/A Qualitech WO WO-2626 SFI Code DHT
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Magnetization
Technique Yoke pull 10lbs Equipment Type Electromagnetic Yoke Serial Number QT24967
Current Flow Alternating Voltage 220 V Magnetization Longitudinal
Pole Spacing 4" - 6" White Light Intensity 1200 lux UV Light Intensity N/A
Flux Indicator Burmah Strip Demagnetization Required No    

Consumable
Method Wet Colour Visible FL/Sample AT Visible: 1.2ml - 2.4ml / 100ml Black Light SN N/A
Particle Type 7C BLACK Manufacturer Magnaflux Batch Number 2101009718
Contrast Type WCP-2 Manufacturer Magnaflux Batch Number 2101009620
Antifoaming Type WA-4 Manufacturer Magnaflux Batch Number 2101009595

Equipment
Equipment Description Master bushing Serial Number 122181
Size N/A Quantity 1 Temperature 29 °c
Acceptance Criteria EN-1369 Acceptance Level N/A Manufacturer DNV
Material Carbon Steel Surface Condition Clean Number of Repairs N/A
Welding Process Used N/A Post Weld Heat Treatment No Reference Drawing N/A

Pictures

Cleaning part. Cleaning part.

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 1
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-110-3
Client Work Order N/A Qualitech WO WO-2626 SFI Code DHT
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Cleaning part. Part contrasted.

Part contrasted. Part contrasted.

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 2
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-110-3
Client Work Order N/A Qualitech WO WO-2626 SFI Code DHT
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Crack found.( 44,97mm) Cracks found.(43,48mm)

Crack found.(7,49mm) Crack concentration found.(18,87mm)

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 3
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-110-3
Client Work Order N/A Qualitech WO WO-2626 SFI Code DHT
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Linear and aligned indications( 47,78mm) Crack

Comments
Area Inspected: As per client request a visual and magnetic particle inspection was carried out on 100% of the accessible critical and stress areas of the
Master bushing.

Result: Defects were found at the time of inspection.

Conclusion: Refer to manufacturer guidelines for further advice.

Recommendations: Remove from service.

Inspector Inspector Signature† Inspection Date Approver Approver Signature†


Name & Qualification Name & Qualification
Tito Fabrin 12-Feb-2023 Luiz Felipe Leitão Jorge
SNT-TC-1A Quality Assurance
†Digitally Signed

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 4
 

Magnetic Particle Inspection Report


Identification
Client Equinor Installation PGC Report Number MP-2626-379-6
Client Work Order N/A Qualitech WO WO-2626 SFI Code DHT
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Magnetization
Technique Yoke pull 10lbs Equipment Type Electromagnetic Yoke Serial Number QT24967
Current Flow Alternating Voltage 220 V Magnetization Longitudinal
Pole Spacing 4" - 6" White Light Intensity 1200 lux UV Light Intensity N/A
Flux Indicator Burmah Strip Demagnetization Required No    

Consumable
Method Wet Colour Visible FL/Sample AT Visible: 1.2ml - 2.4ml / 100ml Black Light SN N/A
Particle Type 7C BLACK Manufacturer Magnaflux Batch Number 2101009718
Contrast Type WCP-2 Manufacturer Magnaflux Batch Number 2101009620
Antifoaming Type WA-4 Manufacturer Magnaflux Batch Number 2101009595

Equipment
Equipment Description Insert Bowl Serial Number 2011410 7K0083
Size 9.5/8'' x 10.3/4'' Quantity 1 Temperature 29 °c
Acceptance Criteria EN-1369 Acceptance Level N/A Manufacturer N/A
Material Carbon Steel Surface Condition Clean Number of Repairs N/A
Welding Process Used N/A Post Weld Heat Treatment No Reference Drawing N/A

Pictures

Insert Bowl Insert Bowl

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 1
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-6
Client Work Order N/A Qualitech WO WO-2626 SFI Code DHT
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

100% MPI. 100% MPI.

Areas with discontinuities. Areas with discontinuities present.

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 2
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-6
Client Work Order N/A Qualitech WO WO-2626 SFI Code DHT
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Areas with discontinuities present. Areas with discontinuities present.

Areas with discontinuities present. Areas with discontinuities present.

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 3
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-6
Client Work Order N/A Qualitech WO WO-2626 SFI Code DHT
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Areas with discontinuities present. Areas with discontinuities present.

Areas with discontinuities present.

Comments
Area Inspected: As per client request a visual and magnetic particle inspection was carried out on 100% of the accessible critical and stress areas of the
Insert Bowl . Equipment has several discontinuities.

Result: Defects were found at the time of inspection.

Conclusion: Refer to manufacturer guidelines for further advice.

Recommendations: Remove from service.

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 4
Magnetic Particle Inspection Report
Identification
Client Equinor Installation PGC Report Number MP-2626-379-6
Client Work Order N/A Qualitech WO WO-2626 SFI Code DHT
Inspection Procedure PI-QT-031 Standard API RP 8B Cat IV Purchase Order N/A

Inspector Inspector Signature† Inspection Date Approver Approver Signature†


Name & Qualification Name & Qualification
Renan Soares dos santos 10-Feb-2023 Luiz Felipe Leitão Jorge
SNT-TC-1A Quality Assurance
†Digitally Signed

www.qualitechirm.com
RP-QT-097 Rev. 9 Quality for Safety Page 5
 

Visual Survey Inspection Report


Identification
Client Equinor Installation PGC Report Number VS-2626-418-1
Client Work Order N/A Qualitech WO WO-2626 SFI Code BHA
Inspection Procedure PI-QT-016 Standard DS-1 Purchase Order N/A

Equipment
Equipment Description IBOP
Serial Number 40493-B
Details N/A
Corrective Action Pin 7 5/8"REG damaged, workshop repair.

Pictures

Panoramic photo Pin 7 5/8"REG damaged

Pin 7 5/8"REG damaged

www.qualitechirm.com
RP-QT-017 Rev. 4 Quality for Safety Page 1
Visual Survey Inspection Report
Identification
Client Equinor Installation PGC Report Number VS-2626-418-1
Client Work Order N/A Qualitech WO WO-2626 SFI Code BHA
Inspection Procedure PI-QT-016 Standard DS-1 Purchase Order N/A

Comments
Area Inspected: As per client request a visual survey inspection was carried out on 100% of the accessible critical and stress areas of the IBOP.
Mechanical damaged thread e seal.

Result: Defects were found at the time of inspection.

Conclusion: Refer to manufacturer guidelines for further advice.

Recommendations: See corrective action above.

Inspector Inspector Signature† Inspection Date Approver Approver Signature†


Name & Qualification Name & Qualification
Luis Silva 31-Jan-2023 Thiago Vasconcelos
SNT-TC-1A Quality Assurance / Quality
Control
†Digitally Signed

www.qualitechirm.com
RP-QT-017 Rev. 4 Quality for Safety Page 2
 

Company Certificates

www.qualitechirm.com
Quality for Safety Page 1
Company Certificates

www.qualitechirm.com
Quality for Safety Page 2
Company Certificates

www.qualitechirm.com
Quality for Safety Page 3
Company Certificates

www.qualitechirm.com
Quality for Safety Page 4
Company Certificates

www.qualitechirm.com
Quality for Safety Page 5
Company Certificates

www.qualitechirm.com
Quality for Safety Page 6
Company Certificates

www.qualitechirm.com
Quality for Safety Page 7
Company Certificates

www.qualitechirm.com
Quality for Safety Page 8
Company Certificates

www.qualitechirm.com
Quality for Safety Page 9
Company Certificates

www.qualitechirm.com
Quality for Safety Page 10
Company Certificates

www.qualitechirm.com
Quality for Safety Page 11
Company Certificates

www.qualitechirm.com
Quality for Safety Page 12

You might also like