1. Prerequisites
Before installing Sinumerik 840D VNCK (in the following just called VNCK) you should make sure that
the following prerequisites are met:
A compatible version of the simulation application (see release notes) should be installed.
Licensing for the simulation application should be set up correctly.
You should have the required licenses for VNCK.
Administrative privileges on the computer.
The UDP-ports 49999 and 50000 must be available. For machines with two NCUs the UDP-port
50001 is required additionally. (For details see VNCK_Reference.pdf)
The simulation application with VNCK (and HMI) has to be run at least once with administrator
privileges and boot the VNCK successfully to enable the access to the required ports.
If you already have a version of VNCK 2.6 SP1 installed and want to use it further on then it is required
that you install VNCK 2.6 SP1 HF1 before you install VNCK 4.7 and / or HMI sl 4.7. The setup and
installation instructions for VNCK 2.6 SP1 HF1 are available at the ftp-server at
Tecnomatix Products/Full products/Windows (32bit)/RealNC/RealNC_VNCK_2.6_SP1_HF1.zip.
If you want to use older versions of VNCK on them same computer then please install them in
chronological order starting with the oldest version first.
Warning: There is a bug in all VNCK setups with version numbers smaller than 4.5 (e.g. VNCK 2.6 and
4.4). Unfortunately that bug was detected after releasing the setup for VNCK 4.4 SP1 HF2. However the
bug has effect only when uninstalling VNCK on a machine where more than one VNCK is installed. The
uninstall process removes in general all HMI-Base services and removes not only the VNCK version it is
called for but corrupts also the chronological latest installed VNCK version.
As a workaround we recommend in case of an uninstall process to remove for safety reasons all
VNCKs and HMIs and then reinstall the needed VNCK and HMIs in the correct sequence.
3.5 Trace-Files
In case your simulation application with VNCK still produces errors (e.g. during the boot phase, or
during simulation) it is recommended to send the exact error message to the Siemens Industry Software
hotline. In general it is helpful to produce additional trace files with detailed information about what is
going on. VNCK 4.5 and following versions offer this by creating so called vncATrace-files. To activate
the trace you should follow these guidelines:
Locate the file “<VNCK_Install_Dir>\theVNC.ini” and open it in an editor (e.g. notepad.exe). In
case that your account has not the required access rights to save that file you may also edit /
create the “C:\Users\<username>\AppData\Local\Siemens\Sinumerik\VNCK\v4.7.4\theVNC.ini”
instead. All settings there will dominate all settings from other “theVNC.ini” files.
Identify the [GLOBAL]section in the file (marked red):