Degraderesearch On Degradation Modeling of Pick-Up Time For Aerospace Electromagnetic Relay in Long-Term Stockpile
Degraderesearch On Degradation Modeling of Pick-Up Time For Aerospace Electromagnetic Relay in Long-Term Stockpile
Degraderesearch On Degradation Modeling of Pick-Up Time For Aerospace Electromagnetic Relay in Long-Term Stockpile
Abstract by the test data in the storage process, which is important for
The storage degradation test system for aerospace both relay manufacturer and user.
electromagnetic relay (EMR) is designed, which uses FPGA The relay characteristic of pick up time, time for the N.O.
and ARM SCM architecture as system’s hardware core. The contact to close, is sensitive to changes in electromagnetic
degradation data rule of pick-up time parameters for force, spring force, and other wear factors in the contact
aerospace EMR is tested. And the variation law of pick-up system associated with component degradation, so it contains
time changing with time is obtained. The change of pick-up the feature information reflecting relay component
time is analyzed and verified, which is mainly caused by degradation. Hammerschmidt et al. pointed that there are
reeds reaction occurred relaxation. Then, pick-up time and deterministic relation within some parameters, such as pick-
up time, contact clearance and contact pressure, etc [3].
reed reaction exists the approximate linear relationship was
During the aerospace relay storage accelerated test, it is found
found. So, the pick-up time can characterize the degradation that pick-up time change obviously during the storage
of reed relaxation. The storage degradation model of pick-up process. The foundations for design and storage reliability
time is estimated through regression theory. The research assessment are provided by finding degeneration reasons and
results in this paper provide the necessary theoretical method confirming the relay components which lead to the pick-up
and basis for studying storage reliability and life prediction time changed.
of the aerospace EMR. The pick-up time is affected by both coils and reeds. The
coils provide attractive force and reeds provide spring force,
Keywords-aerospace electromagnetic relay; storage and relay motions by the resultant force. The degradation of
reliability; pick-up time; degradation; stress coil within storage process is the changes of insulated wire
resistance, and the changes of spring force characteristics
I. INTRODUCTION mainly come from stress relaxation. Now, the research of
Aerospace relays are one of the indispensable key material stress relaxation has been very well researched by
components in National Defense Weapon Equipment System, international and domestic academics. Fox pointed the fall
and its storage reliability affects reliability of weaponry rate of stress relaxation and time follow a linear relationship,
equipments directly. Lu Jianguo analyzed the mechanism of when he researched the bending stresses relaxation
aerospace electromagnetic relay storage, and predicted characteristics of BeCu alloy strip [4]. Hashizume researched
accelerated storage life test data based on Grey theory [1]. Li the stress relaxation characteristics of copper alloy that used
Ling solved the optimization design problem of relay small to be spring and established Hashizume formula [5]. Zhu
sample storage accelerated test scheme by Gibbs sampling Yongqing took accelerated stress relaxation test of domestic
MCMC method [2]. tin bronze and beryllium bronze domestic relay contact reed
In the Aerospace EMR storage process, the reed, coil, materials, such as tin bronze and beryllium bronze, and he
varnished wire and magnetic materials, etc. will degraded to a calculated the value of long time stress relaxation by short
certain extent. The degeneration will affect relay performance time change law[6]. Now, the most stress relaxation is
characteristic or contact performance. For aerospace relays in researched simply from the views of material. In this paper,
long-term stockpile, the regression is accurately assessed and the degradation reasons of relay pick-up time in storage will
the current or future performance characteristics are predicted be analyzed and confirmed, and pick-up time is used to
a) Major structures of relay testing system a) Trend of pick-up time average value
Authorized licensed use limited to: TUBITAK ULAKBIM. Downloaded on May 26,2023 at 13:57:25 UTC from IEEE Xplore. Restrictions apply.
electromagnetic force closing the contacts and the contact A. Relationship of Pick-up Time and Spring Force
spring force holding the contacts open. The magnetic force To research the relationship of relay pick-up time and
varies with the gap between the armature which is attached to spring force, finite element modeling was carried out and
the spring and the core pin of the induction coil. The dynamic characteristics simulated on a certain aerospace
magnetic force pulls the armature toward the core pin and EMR by MSC.ADAMS (as shown in figure 4).
increases as the gap becomes smaller. The stability of the
magnetic force from the coil to degradation is mainly a
function of the electrical resistance stability of the coil
winding.
The contact spring applies a force in the opposite direction
to the magnetic force in trying to keep the contacts separated.
The magnetic effect must be larger than the spring force in
order to close the contacts. The spring force also increases,
similar to the magnetic force, as the gap between the armature
Fig. 5. Finite element model of aerospace EMR
and core pin becomes smaller. The stability of spring force to
degradation is mainly a function of stress relaxation which The change of the spring force characteristics during the
occurs from a combination of spring stress and temperature storage can be described by set of curves. Here initial force is
exposure. selected as the parameter on behalf of the relay spring force
The pick-up time is the time it takes to close the contacts. characteristics for easy analysis and discussion. Initial force is
This is a function of the net force for the magnetic force the representative value on the relay spring force curve. The
minus the spring force. If the magnetic force decreases due to initial force is a point force at the time of movable contact and
an increase in coil wire resistance the pick-up time will N.C.static contact breakaway by the bottom of armature
increase. If the spring force decreases due to stress relaxation pushed. On the premise that the size of relay and the relative
the pick-up time will decrease. location of movable contact and static contact are not
The stability of coil resistance was studied in a storage changed, the relationship of spring force characteristics and
accelerated test. The results are show in Table 1. The change pick-up time, when initial force is [0.65, 0.75]N and step size
in coil resistance was very small about 0.2%. This difference is 0.005N, is shown in figure 6. It can be seen that there is a
is insignificant. This means that pick-up time variations are nearly linear relationship between reed initial force and pick-
mainly a function of spring relaxation and that spring
relaxation can be calculated from changes in pick-up time. up time, and the slope is 3900 s / N .
3.8
TABLE I. MEASUREMENTS OF COIL RESISTANCE IN RELAY STORAGE
3.6
Time 0h 200h 400h 600h
Pick-up time (µs)
3.
4
Authorized licensed use limited to: TUBITAK ULAKBIM. Downloaded on May 26,2023 at 13:57:25 UTC from IEEE Xplore. Restrictions apply.
And, the pick-up time is nearly linear with the spring force as
follows:
Tx =kFx +c
Then put the formula (1) into the formula (2) to get the model
of pick-up time in storage as:
Figure 8 gives the relationship between pick up time and The accelerated storage data is disposed by least square
initial time of relay during 600h. It is can be seen that pick-up method that the contours fit using formula (4), which adjusts
time and initial force both decrease with time elapsing, and it the non-linearity of test data are shown in figure 9. The
is nearly a straight line. The line in the figure is the fitting storage test data of pick-up time and storage degradation
result, and the slope is 3770 s / N . It further testifies that the model (based on fitted parameters) are in good agreement.
change of pick-up time during storage is caused by spring
force rather than attraction force, and there is a local linear test values of pick-up time
relationship between pick-up time and initial force. degradation model of pick-up time
Fig. 8. Relationship of reed initial forces and pick-up time obtained in V. CONCLUSION
test This paper has made research on degradation modeling of
pick-up time for aerospace electromagnetic relay in long-term
The results of simulation and test prove the linear relation stockpile. From a series of consequences of previous testing,
between pick-up time and initial force. The uncertain factors this leads to the following results:
during the production process of aerospace relay cause the
small deviation between simulations and test. (1) In the accelerated storage degradation test, pick-up time
The analysis above shows that it is feasible to reflect the has shown the reduced trend. The results showed that
change of stresses of reed during the storage by use of the test there were two obvious phases in the pick-up time
results of pick-up time. There is a great necessity to research changes process. The two stages are as follows: stage 1:
the performance deterioration and reliability of aerospace rapid drop in closing time for aging under 1000 hours,
relay during storage. Furthermore, the storage reliability of stage 2: gradual further decline in closing time above
reed and even the whole reed can be evaluated and predicted 1000 hours.
by building the degradation model of pick-up time.
(2) The presumption of pick-up time change rule is
IV. STORAGE DEGRADATION MODEL OF PICK-UP TIME associated with stress relaxation has been proven by
tests and simulation result.
There is linear relation between the pick-up time and
spring force, and according to the stress relaxation theory, the (3) The simulation and test results show that pick-up time is
degradation model of pick-up time in storage may be inferred. nearly linear with the spring force. And so what that
The most common model of stress relaxation is Larson means is feasible to study the stress relaxation in storage
Miller method [9]. The empirical formulae of Larson Miller by means of analyzing the pick-up time change rule.
method can be expressed as: (4) The model for pick-up time and stress relaxation in
storage has been tested and found to predict stress
=F S = T +460 log t +C relaxation. This provides a reference base for future
research on improvement of relay storage reliability.
where θ is Larson-Miller parameter, T is Fahrenheit, t is time,
ACKNOWLEDGMENT
and the constant C is 20.
So, the values of the percentage of remaining initial force The authors express their great thanks to the support of the
in stress relaxation test as follows: National Natural Science Foundation of China (Grant
No.51507074), China Postdoctoral Science Foundation
FS /F0 = T +460 log t +20 (Grant No.2015M571898), the Natural Science Foundation of
Higher Education Institutions of Jiangsu Province (Grant
Authorized licensed use limited to: TUBITAK ULAKBIM. Downloaded on May 26,2023 at 13:57:25 UTC from IEEE Xplore. Restrictions apply.
No.15KJB470003), and the Opening Foundation of Zhejiang [5] Hashizume K , Agatsuma T. Stress relaxation in
Provincial Top Key Discipline (Grant No.ZSTUME01A02). bending on some copper alloys for spring use. Journal
of the Japan Copper and Brass Research Association,
REFERENCES 1982,21:159- 167.
[6] Y. Q. Zhu, J. G. Lu. Experimental Study on the Stress
[1] J. G. Lu, Y. Y. Luo, W. H. Li, F. B. Meng, L. Z. Wang. Relaxation of Contact Spring Material of Relay.
“Storage Life Test and Failure Analysis of Aerospace Jiangsu Apparatus, 2008(2):55-57.
Relays,” Transactions of China Electrotechnical [7] Z. B. Wang, G. F. Zhai, X. Y. Huang, D. X. Yi.
Society. 2009, 24(2): 54-59 . Combination Forecasting Method for Storage
[2] L. Li, W. Xu. Analysis for Accelerated Life Test of Reliability Parameters of Aerospace Relays Based on
Relays based on MCMC Method. Low Voltage Grey-Artificial Neural Networks. International Journal
Apparatus, 2010, 2:13-16. of Innovative Computing, Information and Control,
[3] Hammerschmidt M , Alexander R,Rieder W. The 2013, 9(9): 3807-381.
Effects of Material Transfer in Relays Diagnosed by [8] X. Zhou, J. F. Shi, G. F. Zhai. Testing and Analyzing
Force and/or Voltage Measurement. IEEE Trans. on Force for of Attraction Force and Mechanical
Components and Packaging Technologies, 2004, 27 Electromagnetic Relay. Electromechanical
(1):12-18. Components, 2005(25): 6-8.