CENTRIFUGAL ROOF
BIFURCATED destratification
Twinflow
STDR DCV
ATEX SMOKE
Wiring
Diagrams
CIRCULATING WINDOW/WALL
t: 01384 275800
f: 01384 275810
e: bs@eltafans.co.uk
visit: eltaselect.com HEAT RECOVERY ACCESSORIES
Twinflow STDR DCV EC
Wiring Diagram Compatibility
Please use the table(s) below to match up the product code and the wiring diagram number.
EC SINGLE Phase - 220V to 240V / 50Hz or 60Hz EC THREE Phase - 380V to 415V / 50Hz or 60Hz
CONNECTIONS SCHEMATIC
DEVICE ENABLE
COMMON TO 21
INPUT 0-10V DC
COMMON TO
ANALOGUE OUTPUT
ANALOGUE OUTPUT
ANALOGUE
COMMON TO 91 & 92
ANALOGUE
COMMON TO 81 & 82
10, 11 &12
GROUND
TRICKLE / BOOST
REMOTE ENABLE
DAMPER
HEATER
COMMON TO 51
COMMON TO 84
FAN 2 STATUS
FAN 1 STATUS
FAN 2 SPEED
FAN 1 SPEED
0-10V DC
0-10V DC
- 32 31 23 21 20 13 12 11 10
92 91 90 84 83 82 81 80 51 50 E N L
SENSORS OUTPUTS
GREEN/YELLOW
(0V - 10V) DC ANALOGUE INPUT FOR
BROWN
BLUE
TEMPERATURE, HUMIDITY, CO2, FACTORY WIRED ONLY
PRESSURE OR MANUAL CONTROL
DEVICE CUSTOMER CONNECTIONS
DCV BOTTOM TIER CONNECTIONS ENABLE 220V - 240V 1Ph50Hz ROOM CONTROL
DCV 3Ph SUPPLY UNIT MAINS SUPPLY CONNECTIONS
92 91 90 84 83 82 81 80 51 50 E N L3 L2 L1
ORANGE
YELLOW
BROWN
BLACK
RED
COMMON TO 81 & 82
ANALOGUE OUTPUT
ANALOGUE OUTPUT
COMMON TO 91 & 92
TRICKLE / BOOST
REMOTE ENABLE
COMMON TO 51
COMMON TO 84
FAN 1 STATUS
FAN 2 STATUS
FAN 2 SPEED
FAN 1 SPEED
0-10V DC
0-10V DC
40 41 42 43
92 91 90 84 83 82 81 80 51 50 E N L3 L2 L1
32 31 32 31 23 32 31 23
+ -
0-10V
INPUT
4 3 2 1 0 +
32 31 23 32 31 23
8 7 6 5 4 3 2 1 4 3 2 1
ENABLE CONFIGURATION
81 80 51 50 81 80 51 50 81 80 51 50 81 80 51 50
Tel: 01384 275800 fax: 01384 275810 email: bs@eltafans.co.uk visit: eltaselect.com Twitter: @eltaselect & @eltafans 3
Wiring Diagram No.
EC
152-527 Please check the individual product accessories
table for fan and controller compatibility.
92 91 90 84 83 82 81 80 51 50 - 32 31 23 21 20 13 12 11 10
COMMON TO
COMMON TO 81 & 82
ANALOGUE OUTPUT
ANALOGUE OUTPUT
COMMON TO 91 & 92
REMOTE ENABLE
ANALOGUE
ANALOGUE
TRICKLE / BOOST
10, 11 &12
COMMON TO 51
DAMPER
COMMON TO 84
HEATER
GROUND
FAN 1 STATUS
FAN 2 STATUS
FAN 2 SPEED
FAN 1 SPEED
0-10V DC
0-10V DC
- 32 31 23 21 20 13 12 11 10
92 91 90 84 83 82 81 80 51 50
SENSORS OUTPUTS
ENABLE
N L1 L2 L3
ORANGE
YELLOW
BROWN
BLACK
RED
40 41 42 43 N L1 L2 L3 E
32 31 32 31 23 32 31 23
+ -
0-10V
INPUT
4 3 2 1 0 +
TEMPERATURE SENSOR
PRESSURE SENSOR
149-DCV-TRT
149-DPT3
140-DPT5
32 31 23 32 31 23
8 7 6 5 4 3 2 1 4 3 2 1
ENABLE CONFIGURATION
81 80 51 50 81 80 51 50 81 80 51 50 81 80 51 50
Tel: 01384 275800 fax: 01384 275810 email: bs@eltafans.co.uk visit: eltaselect.com Twitter: @eltaselect & @eltafans 4
BUILDING SERVICES APPLIED TECHNOLOGY EXPORT
Tel: +44 (0) 1384 275800 Tel: +44 (0) 1489 566500 Tel: +44 (0) 1489 566500
Fax: +44 (0) 1384 275810 Fax: +44 (0) 1489 566555 Fax: +44 (0) 1489 566555
e-mail: bs@eltafans.co.uk e-mail: at@eltafans.co.uk e-mail: export@eltafans.co.uk
www.eltafans.com
A member of
BS EN ISO 9001:2008 HEVAC ASSOCIATION
FM 556465 A member of GROUP LIMITED