UNIVERSITI TEKNOLOGI MARA

CENTRE OF STUDIES FOR QUANTITY SURVEYING


FACULTY OF ARCHITECTURE, PLANNING AND SURVEYING

BACHELOR OF QUANTITY SURVEYING (HONS) (AP224)


SEMESTER 1 2021/2022

COMPUTER AIDED MEASUREMENT & ESTIMATING (BQS562)

AIM

LAB
Demonstrate ability to use software application and
tools to produce Bills of Quantities for construction
project.

TASK
The drawing No. PUB/BQS562/FRAME/1-4 shows the
EXERCISE II:
detail for Frame for a surau
1. Take-off complete all necessary work related to: FRAME
i) FRAME
based on the principles in Standard Method of
Measurement II (SMM2).
2. Prepare Bills of Quantities (BQ) accordingly. ASSESSMENT RUBRICS
3. Priced the Bills of Quantities according to the
latest rates including with all necessary profit &
No. CRITERIA SCALE
overhead allocation. Very poor
MEASUREMENT/
A TAKING-OFF SKILL Excellent
Taking off by using software are being
i. carried out accoding to SMM2 1 2 3 4 5
SUBMISSION Points of references are accurately
ii. placed 1 2 3 4 5
All submission must be in the form of: Method of distingushing items for
measurement are clearly indicated in
1. Complete priced BQ in PDF and Excel format.
iii. drawings. 1 2 3 4 5
2. PDF drawings with all necessary MARKUP LABEL Critical thinking in identifying method of
iv. measurement. 1 2 3 4 5
as proof of taking off.
Scaling of drawings are accurately
v. identified. 1 2 3 4 5
3. The files should be uploaded in Google Classroom
according to class. B BILL OF QUANTITIES (BQ) PRODUCTION
BQ items are consistent with taking off
i. quantities 1 2 3 4 5
BQ are prepared according with
MARKS ii. prevailing principal and format. 1 2 3 4 5
BQ are neat, accurate and presentable
iii. according to elements. 1 2 3 4 5

20% C

i.
CONCEPT & PRINCIPAL
Students have demonstrated the ability to
use software application and tools.
Students manage to produce Bills of
1 2 3 4 5

ii. Quantities for the element appropriately 1 2 3 4 5


SUBMISSION DATE
TOTAL SCORE (50)

Friday, TOTAL SCORE REDUCED TO (20)

3 December 2021
AP/FRAME/BQS562

SPECIFICATION NOTES
AmRlication Notes on Measurement Please read carefuII)'.'. A. REINFORCED CONCRETE WORK
Toke-off complete all works associated with the el ement of 1. Prior to commencement of concreting, the Contractor shall submit to the S.O. for his approval, all
detailed proposal for the sequence of placing concrete and the positions of all vertical and horizontal

FRAME. joints (If any). Such proposals shall be submitted to the S.O. at least two weeks before scheduled date of
concreting.
2. No concrete shall be placed until the steel reinforcement has been checked and approved by the S.O.
or his representative.
3. All fresh concrete shall be protected by approved means from rain, sun and drying wind to maintain
suitable temperature and moisture.

4. All cone. work to be in accordance with the B.S. 8110 ; 1997 and its testing shall be in Accordance
with B.S. 1881.

5. All cone. placed (Unless Otherwise Stated) to be Grade 25 for Concrete as per JKR Specification
with nominal Mix. Using 20mm Size Graded Aggregate and having a minimum cube crushing strength of
35Mpa of 28 days.

6. Minimum cement content to be 360kg/m3 with maximum water cement ratio to be 0.50
as per JKR Specification.

7. All cone. placed ta be compacted with approved vibrators.

8. Cone. cover clear of all reinforcement (unless otherwise stated) to be as follows: -

a). Footing 50mm d). Floor & Roof Beams 40mm


b). Stump 40mm e). Columns 40mm

c). Ground Beams 40mm f). Slabs 40mm

9. All reinforcement shown to comply with B.S. 4449

10. No holes or chases are permitted in cone. member others than those detailed or authorised. No bars
are to be cut without specific instruction from The Engineers.

11. The contractor sholl advise the engineer when reinforcement is ready for inspection before concrete is
poured and adequate notice shall be given to enable inspection to be carried out.

12. 50mm thk. 1: 3: 6 - 40mm aggregate cone. blinding to be provided to be base of all ground beams,
slabs and pilecaps/footings.

13. All Slab Thickness Shall be 150mm Unless Otherwise Stated · -

a). HFS - Prop. Half Slab With Cast In-Situ Topping

b ). FS - Prop. Cast In-situ Slab

14. - - Column Going Through

� - Column Ending

D COB - Column On Beam

15. Water proofing to be provided for all bathrooms and exposed slabs.

PROJECT: DRAWING TITLE SUBJECT: DRAWN BY AF

CADANGAN MEMBINA SURAU CHECKED BY MAM


GENERAL NOTES
AR RAHMAN, COMPUTER AIDED
SCALE N.T.S
MEASUREMENT &
BANDAR SAUJANA PUTRA, ESTIMATING DATE
SELANGOR DARUL EHSAN
COURSE CODE
BQS562 DRAWING NO. PUB/BQS562/FRAME/1
AP/FRAME/BQS562

3050 3050 3050 3050 3050 3050 3050 3050

Cl cs
-
-- -- -
-- -- --
-

1 1 I 1 1 I

T
1 I 11 11 I

T
C) Fs11+ + + FS29+

3
LO
C)

l,7
0
r")
�I I 11 11

Cl C3 Cl
-- -- -- -- --

0
LO I Fs2+ 11 F 3+ 11 F g+ I
1 1 I 1 I
jl
0

--+-
jj
r")
1 11

_C1--=���0D,600)����= = �-� = = -:::::::=J___ FS24-+----�-==��

--+---:�--+--
I I I I I

-+- -:: - � - -�,


0
r")
00

]�
I

1
_____,�11

I
_ Fs1+ 1
11

_:: 1
=i
�=r ___:c_ _-
F54t_ ___ Iii

I
_ d7--r

I 1
--J'_+_
C4

l
Il

J_
,1 1

Jsr���= = ilisr� �=-- = = �, ___


0
r")
00

c6 Fs12 ____
= =-=_:::��oo,,oo)
gl ,r-= I T-= I I
C4
I
0
LO
0
r")
iI Fss+ 11 F 6+
j
11 F s+
j
I
�I
c.:, II II I
�11 Cl

0
LO
0
r")

GROUND FLOOR KEY PLAN


ALL SLAB THICKNESS = 150 MM THK. U.N.O
PROJECT : DRAWING TITLE : SUBJECT: DRAWN BY AF
CHECKED BY MAM
CADANGAN MEMBINA SURAU GROUND FLOOR KEY PLAN COMPUTER AIDED
AR RAHMAN, MEASUREMENT &
SCALE 1 : 100
BANDAR SAUJANA PUTRA, ESTIMATING DATE
SELANGOR DARUL EHSAN COURSE CODE
BQS562 DRAWING NO. PUB/BQS562/FRAME/2
AP/MAY2021/BQS562

--- ---
3050 3050 3050 3050 3050 3050 3050 3050

RBl 150x450

rx --- --- ==t ---


---1
� I� Is 1--- I

-<:::::
0
LC)

0
-st"
0
X
-st"

0
X
LC)
LC) LC)
n
0
N
?:::i'
co CD

a:: a:: �
1 5 150x450 RB4 150x450
-- --

I I
I Fp1+
I 1 1

-7t-
� 1 1

I
/
�_J_ -

R�50x450)___ --=
-------

+- --+-�--+-+-
0 � I I
I'
_\j_ I
n
� I

0
'f + -�

r: T f
N
� I Rf1fil150x450)_I
___

I
I I I

-r:: :=r: y- :�=r:


0
!
a::
0 0

\
F�2 + I
I I I �I ;§ I

_ __v
0 �

l
I
n
� CD
a:: CD

RB.fil1_50x450)
a::

al
LC)

0
-st"
X
{7
t-
/
I
-�-
I
� \ I 0
� I
1 I

i' +
0I
�I

-- --

0

--
LC) LC) LC)
0
n
;1
<D
CD
a:: �
a::
1
a::
I I I
RB2(150x450 RB3(150x750) RB_.ill.50x450) - --

-- -- --
-
� 0

-----1- -=:::::::.
0
LC)
-st"
-__:_
�I �I I
0 X X

l
LC)
0
n

_J
N
C ?:::i'
CD
--y-__

_J__
CD a::
a::
450 RB1 200x450

ROOF KEY PLAN


ALL SLAB THICKNESS = 150 MM THK. U.N.O

PROJECT : DRAWING TITLE SUBJECT: DRAWN BY AF


CHECKED BY MAM
CADANGAN MEMBINA SURAU ROOF KEY PLAN COMPUTER AIDED
AR RAHMAN, SCALE 1 : 100
MEASUREMENT &
BANDAR SAUJANA PUTRA, ESTIMATING DATE
SELANGOR DARUL EHSAN COURSE CODE
BQS562 DRAWING NO. PUB/BQS562/FRAME/3
AP/FRAME/BQS562

-----
FLOOR
�K Cl C2 C3 C4 cs C6 STUMP

-
□ 0 D
- -

MAIN t:lAK 4T12 8T20 4T16


D 4T16
0 D 4T16 4T16 4T12
Rf. 300
1-i

llES RB-150 Rl0-225 Rl0-225 R10-225 Rl0-225 R10-225 RB-150


COL. SIZE 200 X 200 450mm Diameter 200 X 850 200 X 800 500mm Diameter 200 X 1000 300 X 3D0

□ 0 0 □
- -

D D
1---COLUMN
Q.

MAIN t:1At< 4112 8T20 4T16


D 4T16 4T16

4T16 4T12
lits R8-150 Rl0-225 Rl0-225 R10-225 Rl0-225 Rl0-225 R8-150 Grd.
COL. SIZE 200 X 200 450mm Diameter 200 X 850 200 X 800 500mm Diameter 200 X 1000 300 X 300

LEVEL
COLUMN REINFORCEMENT SCHEDULE
E
E

T10-100

RBS (150 X 450)


scale : 1:150 lYPICAL SECTION
FOR COLUMN
0
scale : N.T.S

PROJECT: DRAWING TITLE SUBJECT: DRAWN BY AF

CADANGAN MEMBINA SURAU - ROOF BEAM DETAILS CHECKED BY MAM


- COLUMN REINFORCEMENT COMPUTER AIDED
AR RAHMAN, SCHEDULE MEASUREMENT &
SCALE AS SHOWN
BANDAR SAUJANA PUTRA, ESTIMATING DATE
SELANGOR DARUL EHSAN COURSE CODE
BQS562 DRAWING NO. PUB/BQS562/FRAME/4