1 2 3 4 5 5.2 5.4 5.6 5.

8 6 7 8 9 10

B5
A-404
B1
6'-9 1/2" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 3'-2 1/2" A-406
E

A AVIDXCHANGE
2'-3 1/2"

SECURITY 11' - 4"


B B B B B OFFICE / AFF 11' - 4"
AFF
11' - 4"
AFF
INTERIOR UPFIT AT
B B B B B B B B B B EQUIP
R
1201
R
R R
RECEIVING
THE MUSIC
R R R R R
FACTORY
8'-1"

8'-1"
11' - 4" OFFICE
1211A RECEIVING,
AFF MAINTENANCE
STAGING &
/ WORKSHOP
MAIL
TEL/DATA 1211C
B B B B CAFE SEATINGB B B B B B B 1211
ACT-6 120
1000
R R R R R R
8'-1"

8'-1"
A.5 EXPOSED CEILING, PAINTED

4'-7 1/2"
4'-2 1/4" 11' - 4"
B AFF
B1
B B B B B B B B B R
3 A-407
R R R

TYP.
3'-6"
CENTER OF ELLIPSE
B
B B B
B B
PNT-2
B GAMING
B
1200

PNT-9

1
3
A-405
D

B 10' - 0"
GAMING AFF
STORAGE Q
COFFEE BAR
CATERING 1200A
1000C
1000B
DISCHARGE

EQ
ACT-3 CORRIDOR
1370

Y Y Y
5 WOMEN'S RR MECHANICAL MEETING RM
C4
SIM
MEN'S RR
1353 MDF RM 1421
1146 A-413

12'-0"
1144
ELECTRICAL 1358
M
WOMENS TEL/DATA JANITOR 1356 B B

EQ
ACT-4 LOCKER RM 1148 FIRE

7'-5 1/4"
ACT-3 1351 7'-6" AFF 227 WEST TRADE STREET SUITE 700
ACT-2 B COMMAND
1864
EQ 4'-0" 4'-0" EQ CHARLOTTE, NORTH CAROLINA 28202
M 1371
TEL. 704.333.6686 FAX 704.333.2926

EQ
STAIR #1 STAIR #2

EQ
ACT-3 Y Y Y WWW.LS3P.COM
1131 1322
B B

EQ
EQ 6'-0" 6'-0" EQ 11' - 4"

7'-5 1/4"
AFF
C STORAGE
1863 B

EQ
EQ
3
B B 8'-0" B 8'-0" B 8'-0" B 8'-0" B 8'-0" B 8'-0" B 8'-0" B 8'-0" B 8'-0" B 8'-0" B 8'-0" B FIRE PUMP

EQ
CORRIDOR

EQ

7'-5 1/4"
B1 MEN'S 1700 1372

8'-5 1/2"
A-404 LOCKER RM 1'-6"
ACT-3 ACT-4 B

EQ
1862 8'-0" 8'-0" 2'-0"

2'-6"
EQ EQ

EQ
C 10' - 0" B

EQ
AFF B B B

7'-5 1/4"
S ACT-2
EXPOSED CEILING, PAINTED MEETING RM
EQ

EQ
R LOBBY B 1423

8'-6"
H

EQ
STORAGE 1600
1721 11'-5 1/4" S M
12' - 10" B

EQ
TYP.

EQ
2'-0"

S AFF

7'-5 1/4"
11' - 4"

24'-0"
B B B 7'-6" AFF

6'-0"
S S S S M8 M8 M8 OPEN TO ABOVE OPEN TO ABOVE AFF
9'-0"

11' - 0" S B
FITNESS EXPOSED CEILING, PAINTED

EQ
AFF M

EQ
9'-1"
CENTER
S S S 3 LOUNGE
YOGA STUDIO STOR 1731 S S

EQ
RR B
PRESENTATION 1400

EQ
L

6'-0"
1861 1751A 1751D S

7'-5 1/4"
11' - 4" 10' - 0"
1500

EQ
C.5

EQ
S S AFF S S AFF

4'-11 1/2" 2'-2"


G B A4 MEETING RM
R R R R

EQ
M8 M8 M8

3'-7 1/4"
NURSE SUITE S S S A-413 1425

2'-6"
9'-0"

9' - 0" 9' - 0"

EQ
ACT-2 WAITING RM S
H 05.06.2016
S S S ACT-3 AFF ACT-3 AFF O B
ACT-3

1751 4'-6" 7'-0" 7'-0" 7'-0" 7'-0" 7'-0" 5'-0"

EQ
G M

7'-5 1/4"
B
NURSE 2'-2 1/4" 11' - 4"
S S S S EXAM 1751C 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 7'-6" AFF AFF

EQ
MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS

7'-0"

EQ EQ
1751B
EQ

M8 M8 M8 M8 M
R R R R
S S S 6'-0 1/4" 3'-11" 3'-6" B B B B B B B B B B B
11' - 4" 11' - 4"
3 ACT-2 COPYRIGHT 2016 ALL RIGHTS RESERVED
11' - 4" AFF AFF 3 3 3 3 3 3 3 PRINTED OR ELECTRONIC DRAWINGS AND
D AFF DOCUMENTATION MAY NOT BE REPRODUCED
IN ANY FORM WITHOUT WRITTEN PERMISSION
11'-0" AFF, TYP. 3 11'-4" AFF, TYP.
FROM LS3P ASSOCIATES LTD.
3 3 3 3 3
C5
A-501
TYP.

REVISIONS:

B No. Description Date


3 CLIENT REQUESTED 05/23/2016
REVISIONS
FIRST FLOOR REFLECTED CEILING PLAN
B1 1/8" = 1'-0"

REFLECTED CEILING PLAN SHEET NOTES RCP LEGEND RCP NUMBERED NOTES PROJECT: 9107-152470

1 PROVIDE SUPPORT TO STRUCTURE AND CONNECTIONS FOR CEILING MOUNTED DATE: 05/06/2016
1. SEE SHEET A-001 FOR WALL TYPES AND HEIGHT OF WALLS ABOVE CEILING. 2X4 LAY-IN CEILING 1'-0" HEIGHT (FEET, INCHES) TYPE L, NEIDHARDT PENDANT MONITOR AND MOUNT BY OTHERS.
2. ACOUSTICAL CEILING TILE SHALL BE ACT-1, UNO. SYSTEM ABOVE FINISHED FLOOR,
AFF
3. SEE FINISH SCHEDULE FOR CEILING TYPES & MATERIALS IN EACH ROOM / AREA. TYPE M, AXIS SCULPT (SUBSCRIPT INDICATES LENGTH)
C:\Users\kyleemme\Documents\Arch_Avidx_2015_kyleemme@ls3p.com.rvt

4. PERIMETER TRACK FOR ALL ACOUSTICAL CEILINGS GRIDS SHALL BE INSTALLED IN ACCORDANCE WITH IBC AND CISCA GUIDELINES. TYPE A, LEUCOS FAIRY 2 PROVIDE SUPPORT TO STRUCTURE AND CONNECTIONS FOR (2) CEILING MOUNTED
5. DIMENSIONS ARE TO FACE OF FINISH WALL. TYPE N, SPECTRUM SQUARE MONITOR AND MOUNT BY OTHERS.
2X2 LAY-IN CEILING TYPE B, ATLANTIC CYLINDER
6. CEILING GRIDS/TILES TO BE CENTERED IN ALL ROOMS UNLESS NOTED OTHERWISE. PARTIAL TILES AT ROOM PERIMETERS SHALL NOT BE LESS THAN 6” IN EITHER SYSTEM TYPE O, AXIS BEAM2 ASSYMETRIC
DIMENSION. TYPE C, AXIS BEAM4 3 PROVIDE SHD-1 WITH LIGHT-LOCK CHANNELS AT EXTERIOR GLAZING.
7. ALL CEILINGS SHALL BE 10'-0" AFF, UNO. CEILING HEIGHTS SHOWN ON THE REFLECTED CEILING PLANS ARE NON-TYPICAL AND SPECIFIC TO THE AREA INDICATED. TYPE P, GOTHAM DOWNLIGHT
REFER TO INTERIOR ELEVATIONS FOR THE HEIGHTS OF SOFFITS ABOVE CASEWORK. TYPE D, LIGHTOLIER VETRO
8. SEE ELECTRICAL, FIRE ALARM AND FIRE PROTECTION DRAWINGS FOR SPECIAL SYSTEMS, SMOKE DETECTORS, LIGHTING AND WALL MOUNTED FIXTURES NOT SHOWN TYPE Q, 2 X 4 LED D/I FIXTURE
ON THIS SHEET. COORDINATE LOCATIONS OF ALL FIXTURES NOT INDICATED WITH LAYOUT INDICATED ON THIS SHEET. GYPSUM BOARD TYPE E, REJUVENATION HALEIGH
9. LIGHT FIXTURES AND MECHANICAL DIFFUSERS ARE SHOWN FOR POSITIONING IN FINISH CEILING SYSTEM. COORDINATE WITH MECHANICAL AND ELECTRICAL
DRAWINGS FOR FIXTURE TYPES, MECHANICAL DIFFUSERS, WALL MOUNTED FIXTURES AND INSTALLATION OF FIXTURES IN SPACES WITHOUT CEILINGS. (LIGHTING AND TYPE F, INTERLUX CLEAR TYPE R, 2 X 2 LED D/I FIXTURE
HVAC DIFFUSERS ARE SHOWN FOR COORDINATION ONLY - SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR SPECIFIC INFORMATION). EXPOSED STRUCTURE -
PENDANT SQUARE
F1 = 12" X 12"
FIRST FLOOR
10. SEE MECHANICAL FLOOR PLANS FOR EXTENT OF EXPOSED DUCTWORK IN EXPOSED STRUCTURE AREAS WITHOUT CEILINGS.
A 11. EXTEND PERIMETER WALLS AND FINISH TO STRUCTURE ABOVE AT EXPOSED STRUCTURE AREAS. PAINT ALL EXPOSED DUCTWORK, PIPING, HANGERS, ETC…
PAINTED F2 = 18" X 18"
F3 = 24" X 24"
TYPE S, RECESSED DOWNLIGHT
REFLECTED
12. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR MOUNTING LOCATIONS OF ITEMS WHERE NO CEILING IS INDICATED.
13. CENTER LIGHTS, DIFFUSERS, EXIT SIGNS SMOKE DETECTORS, SPEAKERS, GENERAL ALARM SPEAKERS/STROBES & MISC DEVICES IN CEILING TILES WHERE THEY ARE
TYPE SW, RECESSED DOWNLIGHT WITH LENSE
CEILING PLAN
LOCATED. ALIGN MULTIPLE ITEM CENTER OR EDGES. EXHAUST AIR GRILLE TYPE G, NEIDHARDT 72X36 OVAL TYPE T, GLOBAL MESH PENDANT
14. LOCATE MECHANICAL GRILLES AND DIFFUSERS SHOWN IN CORNERS OR NEAR WALL TO 12” OFF WALLS, UNO.
15. INSTALL ACCESS PANELS IN GYPSUM BOARD CEILINGS AT DUCT DAMPER CONTROLS, DUCT MOUNTED SMOKE DETECTORS, MANUAL DUCT CONTROLS, ETC.
16. ALL SINGLE LIGHT FIXTURES SHALL BE CENTERED IN THE CEILING WITHIN THEY OCCUR. TYPE U, BASELITE PENDANT
17. LIGHTS LOCATED IN STAIRS SHALL OCCUR AT EACH FLOOR AND INTERMEDIATE LANDINGS. NOT IN SCOPE TYPE H, NEIDHARDT 96X48 OVAL
18. LOCATE SPRINKLER HEADS IN THE CENTER ZONE OF THE CEILING TILE. ALIGN CORRIDOR SPRINKLER HEADS IN THE SAME LINE PARALLEL TO THE WALL WITHIN TYPE Y, SUSPENDED LINEAR FIXTURE
EACH SPECIFIC CEILING CONSTRUCTION.
19. SPRINKLER HEADS, OTHER THAN CONCEALED, SHALL BE FULLY RECESSED (CENTER IN CEILING TILE).

A-121
5/23/2016 5:42:16 PM

20. ALL GWB CEILINGS TO RECEIVE CONCEALED SPRINKLER HEADS. TYPE I, GLOBAL, TREE SERIES SUPPLY AIR DIFFUSER
21. PROVIDE ARMSTRONG 9/16" TEGULAR TRANSITION MOLDING #7907 AT TRANSITIONS FROM ACT TO GWB CEILINGS OF THE SAME HEIGHT. ACT-5(A/B/C) I1 = 22" DIA.
22. COORDINATE TRIM COLOR AND LOCATION OF CEILING MOUNTED SECURITY CAMERAS WITH ARCHITECT PRIOR TO INSTALLATION. 3 I2 = 30" DIA. RETURN AIR DIFFUSER

TYPE J, LITECONTROL COVE EXHAUST FAN 3

TYPE K, NEIDHARDT ZOLLSTOCK C CEILING MOUNTED SECURITY CAMERA

1 2 3 4 5 6 FOR CONSTRUCTION ONLY


1 2 3 4 5 5.2 5.4 5.6 5.8 6 7 8 9 10

EQ EQ EQ

EQ EQ
S S S S AVIDXCHANGE

ALIGN

ALIGN
INTERIOR UPFIT AT

EQ

EQ
PHONE RM PHONE RM R R
2123 2223 EXEC. OFFICE
2301
THE MUSIC
Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q
S R R S
1
FACTORY

EQ

EQ
EQ EQ R R
PHONE RM PHONE RM EQ EQ 1'-0" 1'-0"
2122 2222
A.5 Q Q Q Q Q Q Q Q Q Q
S S
Q Q Q Q Q Q Q Q Q 3

3'-6"
R R

EQ

EQ
ACT-2 ACT-2 C
3 S PHONE RM PHONE RM S 3

EQ
2 2121 2221 2 10' - 0"
AFF

EQ

EQ
Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q
R R
OPEN OFFICE OPEN OFFICE C
2000 S S 2300

EQ
EQ

EQ
EQ EQ
Q Q Q Q Q Q Q Q Q Q D2 7'-6" AFF Q Q Q Q Q Q Q Q Q
C
A-501
S S

EQ
B5 1'-0" M B5
ACT-2

EQ

EQ
A-501 TYP. A-501
MEETING RM
10' - 6" B6
2125 AFF C

3'-6"
Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q A-406 Q Q
S S

4'-0"

4'-0"
D
B EQ EQ

EQ
ALIGN ALIGN EXEC. OFFICE
M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6 M6
3'-6" 9'-8 1/4" 9'-8 1/4" 9'-8 1/4" 9'-8 1/4" 9'-8 1/4" 9'-8 1/4" 9'-2 1/4" 10'-2 1/4" 9'-8 1/4" 9'-8 1/4" 9'-8 1/4" 9'-8 1/4" 9'-8 1/4" 9'-6" 9'-9 1/4" 9'-9 1/4" 9'-9 1/4" 9'-9 1/4" 9'-9 1/4" 9'-9 1/4" 9'-9 1/4" 9'-9 1/4" 9'-9 1/4" 9'-9 1/4" 9'-9 1/4" 6'-6" 2321
R R

EQ
EQ 4'-0" EQ 1'-0"
EQ

EQEQ

EQEQ
EQ

EQ EQ
EQ

EQ EQ
EQ EQ
EQ EQ

2'-6" EQ EQ 2'-6"

EQ
PRINT S S S S

1'-5"

EQ
S S S B2 3 S
2000A R R
A-501 S

EQ
EQ EQ B1 S PRINT / MAIL
D2 EQ EQ EQ EQ R
2'-5"

A-501 R 2358

EQ
A-501 MEETING RM R R
10' - 6" 1'-0" Q Q B2 IDF CL.
1'-0" 2357 CATERING
Q Q Q Q
5 AFF 10' - 6" A-501 S 2500A S S
2402

EQ
AFF
ACT-2 ALT. MECHANICAL ELECTRICAL R
23'-2"

M R STAIR #2
WORKSPACE R R R
2353 2356 WOMENS S
2332
A1 CONFERENCE 2022 STAIR #1 8' - 0"
ACT-2 JANITOR 2444 S S
A-501 7'-6" AFF RM ACT-2 MEN'S RR WOMEN'S RR TEL/DATA AFF ACT-3
2131 2351
LOBBY

EQ
2021 2144 2146 2148 R S
M 2600 R R R
36'-0"

D2 R WELLNESS 227 WEST TRADE STREET SUITE 700


3 S PRINT

4'-0"
Q Q 2530 MENS CHARLOTTE, NORTH CAROLINA 28202
Q Q Q Q A-501 EQ EQ S S S
EQ 14'-0" EQ 2500B 2446 TEL. 704.333.6686 FAX 704.333.2926
ALIGN
1'-0"

S R R WWW.LS3P.COM

EQ
C
B1 STORAGE ACT-2 ACT-2 BOARDROOM
CORRIDOR A5

EQ
2022A 2421
A-501 C C
Q Q Q Q Q Q Q R 2400 A-501
OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE MEETING RM MEETING RM PHONE RM
R R N
2810 2809 2805 2804 2803 2802 2801 2721 2521 2522 3

6'-0"
Q Q Q Q
EQ 5'-0" EQ C C
Q Q Q Q Q Q Q Sim R
2
B4
EQ EQ

PRINT N
A-406
EQ

S 2800A S

6'-0"
10' - 4"
AFF
C

EQ
ACT-2
EQ EQ P P
M6 9'-8 1/4" 9'-8 1/4" M6 9'-8 1/4" M6 9'-8 1/4" M6 9'-8 1/4" M6 9'-8 1/4" M6 9'-8 1/4" M6 9'-8 1/4" M6 9'-8 1/4" M6 9'-8 1/4" M6 9'-8 1/4" M6 9'-8 1/4" M6 9'-8 1/4" 9'-8 1/4" 4'-7 1/2"
9'-6"

EQ
EQ 4'-5" EQ
3'-3"

10'-0" AFF, TYP. M6 ALIGN ALIGN M6 M6 ALIGN M6 N

6'-0"
PHONE RM INTERVIEW RM

3'-3"
2725 2525
3
Q Q Q Q Q Q Q Q Q R U U U U N
R R

ALIGN

ALIGN
B5

6'-0"
OPEN OFFICE B1
A-501

EQ
2800 A-501
PHONE RM BREAKROOM
C.5 3 PHONE RM N

8' - 0"
8' - 0"

AFF
2726 2600A
2526

6'-0"
Q Q Q Q Q Q Q Q Q AFF
R U U U U R R
EQ EQ
ACT-2 3 F3
N 05.06.2016

EQ
1

6'-0"
3
PHONE RM TYPE V, UNDERCABINET LIGHTING F2
Q Q Q Q Q Q Q Q Q 2727 2'-8" EQ EQ EQ 2'-8" 1'-0" MEZZANINE EXPOSED CEILING
R R N 2500 MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS
R INTERVIEW RM F1

EQ
3'-3"
U U U U
1 2527
D COPYRIGHT 2016 ALL RIGHTS RESERVED
PRINTED OR ELECTRONIC DRAWINGS AND
10'-0" AFF, TYP. DOCUMENTATION MAY NOT BE REPRODUCED
3 3 4 IN ANY FORM WITHOUT WRITTEN PERMISSION
3 3 3 3 3 3
FROM LS3P ASSOCIATES LTD.
A1
A-403

REVISIONS:

B No. Description Date


3 CLIENT REQUESTED 05/23/2016
SECOND FLOOR REFLECTED CEILING PLAN REVISIONS
B1 1/8" = 1'-0"
4 CLARIFICATIONS 05/27/2016

REFLECTED CEILING PLAN SHEET NOTES RCP LEGEND RCP NUMBERED NOTES PROJECT: 9107-152470
C:\Users\sivilayxayasaene\Documents\Arch_Avidx_2015_sivixayasaene@ls3p.com.rvt

1 PROVIDE SUPPORT TO STRUCTURE AND CONNECTIONS FOR CEILING MOUNTED DATE: 05/06/2016
1. SEE SHEET A-001 FOR WALL TYPES AND HEIGHT OF WALLS ABOVE CEILING. 2X4 LAY-IN CEILING HEIGHT (FEET, INCHES) TYPE L, NEIDHARDT PENDANT MONITOR AND MOUNT BY OTHERS.
1'-0"
2. ACOUSTICAL CEILING TILE SHALL BE ACT-1, UNO. SYSTEM ABOVE FINISHED FLOOR,
AFF
3. SEE FINISH SCHEDULE FOR CEILING TYPES & MATERIALS IN EACH ROOM / AREA. TYPE M, AXIS SCULPT (SUBSCRIPT INDICATES LENGTH)
4. PERIMETER TRACK FOR ALL ACOUSTICAL CEILINGS GRIDS SHALL BE INSTALLED IN ACCORDANCE WITH IBC AND CISCA GUIDELINES. TYPE A, LEUCOS FAIRY 2 PROVIDE SUPPORT TO STRUCTURE AND CONNECTIONS FOR (2) CEILING MOUNTED
5. DIMENSIONS ARE TO FACE OF FINISH WALL. TYPE N, SPECTRUM SQUARE MONITORS AND MOUNT BY OTHERS.
2X2 LAY-IN CEILING TYPE B, ATLANTIC CYLINDER
6. CEILING GRIDS/TILES TO BE CENTERED IN ALL ROOMS UNLESS NOTED OTHERWISE. PARTIAL TILES AT ROOM PERIMETERS SHALL NOT BE LESS THAN 6” IN EITHER SYSTEM
DIMENSION. TYPE O, AXIS BEAM2 ASSYMETRIC
TYPE C, AXIS BEAM4 3 PROVIDE SHD-1 WITH LIGHT-LOCK CHANNELS AT EXTERIOR GLAZING.
7. ALL CEILINGS SHALL BE 10'-0" AFF, UNO. CEILING HEIGHTS SHOWN ON THE REFLECTED CEILING PLANS ARE NON-TYPICAL AND SPECIFIC TO THE AREA INDICATED. TYPE P, GOTHAM DOWNLIGHT
REFER TO INTERIOR ELEVATIONS FOR THE HEIGHTS OF SOFFITS ABOVE CASEWORK. TYPE D, LIGHTOLIER VETRO
8. SEE ELECTRICAL, FIRE ALARM AND FIRE PROTECTION DRAWINGS FOR SPECIAL SYSTEMS, SMOKE DETECTORS, LIGHTING AND WALL MOUNTED FIXTURES NOT SHOWN
GYPSUM BOARD TYPE E, REJUVENATION HALEIGH TYPE Q, 2 X 4 LED D/I FIXTURE
ON THIS SHEET. COORDINATE LOCATIONS OF ALL FIXTURES NOT INDICATED WITH LAYOUT INDICATED ON THIS SHEET.
9. LIGHT FIXTURES AND MECHANICAL DIFFUSERS ARE SHOWN FOR POSITIONING IN FINISH CEILING SYSTEM. COORDINATE WITH MECHANICAL AND ELECTRICAL
DRAWINGS FOR FIXTURE TYPES, MECHANICAL DIFFUSERS, WALL MOUNTED FIXTURES AND INSTALLATION OF FIXTURES IN SPACES WITHOUT CEILINGS. (LIGHTING AND TYPE F, INTERLUX CLEAR TYPE R, 2 X 2 LED D/I FIXTURE
HVAC DIFFUSERS ARE SHOWN FOR COORDINATION ONLY - SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR SPECIFIC INFORMATION). EXPOSED STRUCTURE -
PENDANT SQUARE
F1 = 12" X 12"
SECOND FLOOR
10. SEE MECHANICAL FLOOR PLANS FOR EXTENT OF EXPOSED DUCTWORK IN EXPOSED STRUCTURE AREAS WITHOUT CEILINGS.
A 11. EXTEND PERIMETER WALLS AND FINISH TO STRUCTURE ABOVE AT EXPOSED STRUCTURE AREAS. PAINT ALL EXPOSED DUCTWORK, PIPING, HANGERS, ETC…
PAINTED F2 = 18" X 18"
F3 = 24" X 24"
TYPE S, RECESSED DOWNLIGHT
REFLECTED
12. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR MOUNTING LOCATIONS OF ITEMS WHERE NO CEILING IS INDICATED.
13. CENTER LIGHTS, DIFFUSERS, EXIT SIGNS SMOKE DETECTORS, SPEAKERS, GENERAL ALARM SPEAKERS/STROBES & MISC DEVICES IN CEILING TILES WHERE THEY ARE
TYPE SW, RECESSED DOWNLIGHT WITH LENSE
CEILING PLAN
LOCATED. ALIGN MULTIPLE ITEM CENTER OR EDGES. EXHAUST AIR GRILLE TYPE G, NEIDHARDT 72X36 OVAL TYPE T, GLOBAL MESH PENDANT
14. LOCATE MECHANICAL GRILLES AND DIFFUSERS SHOWN IN CORNERS OR NEAR WALL TO 12” OFF WALLS, UNO.
15. INSTALL ACCESS PANELS IN GYPSUM BOARD CEILINGS AT DUCT DAMPER CONTROLS, DUCT MOUNTED SMOKE DETECTORS, MANUAL DUCT CONTROLS, ETC.
16. ALL SINGLE LIGHT FIXTURES SHALL BE CENTERED IN THE CEILING WITHIN THEY OCCUR. TYPE U, BASELITE PENDANT
17. LIGHTS LOCATED IN STAIRS SHALL OCCUR AT EACH FLOOR AND INTERMEDIATE LANDINGS. NOT IN SCOPE TYPE H, NEIDHARDT 96X48 OVAL
18. LOCATE SPRINKLER HEADS IN THE CENTER ZONE OF THE CEILING TILE. ALIGN CORRIDOR SPRINKLER HEADS IN THE SAME LINE PARALLEL TO THE WALL WITHIN TYPE Y, SUSPENDED LINEAR FIXTURE
EACH SPECIFIC CEILING CONSTRUCTION.

A-122
19. SPRINKLER HEADS, OTHER THAN CONCEALED, SHALL BE FULLY RECESSED (CENTER IN CEILING TILE).
5/27/2016 2:58:50 PM

20. ALL GWB CEILINGS TO RECEIVE CONCEALED SPRINKLER HEADS. TYPE I, GLOBAL, TREE SERIES SUPPLY AIR DIFFUSER
21. PROVIDE ARMSTRONG 9/16" TEGULAR TRANSITION MOLDING #7907 AT TRANSITIONS FROM ACT TO GWB CEILINGS OF THE SAME HEIGHT. ACT-5(A/B/C) I1 = 22" DIA.
22. COORDINATE TRIM COLOR AND LOCATION OF CEILING MOUNTED SECURITY CAMERAS WITH ARCHITECT PRIOR TO INSTALLATION. 3 I2 = 30" DIA. RETURN AIR DIFFUSER

TYPE J, LITECONTROL COVE EXHAUST FAN

TYPE K, NEIDHARDT ZOLLSTOCK C CEILING MOUNTED SECURITY CAMERA

1 2 3 4 5 6 FOR CONSTRUCTION ONLY