DESCRIPTION 1 (9)
Prepared (also subject responsible if other) No.

EAB/JT/XU B Stensby 1555-SDC 901 08Uen


Approved Checked Date Rev Reference

EAB/JT/XU (Johan Blomqvist) 2004-03-23 A

DESCRIPTION OF MPH,
(MODEM PROTECTIVE HOUSING).

Abstract

This document is a description of the MPH, (Modem Protective Housing).

Contents
1 Terminology.........................................................................................2
2 General................................................................................................2
3 Design and Performance.....................................................................2
3.1 Functional Design................................................................................2
3.2 Cooling ................................................................................................3
3.2.1 Sun Protection.....................................................................................3
4 Electrical Characteristics .....................................................................4
4.1 Grounding............................................................................................4
5 Interface ..............................................................................................4
5.1 External Interface ................................................................................4
5.1.1 Mechanical Interface ...........................................................................4
5.1.2 Electrical Interface ...............................................................................5
5.2 Internal Interface .................................................................................5
5.3 Case Ground .......................................................................................5
6 Environmental Data .............................................................................6
6.1 Temperature........................................................................................6
6.2 Humidity ..............................................................................................6
6.3 Solar Radiation....................................................................................6
6.4 Wind ....................................................................................................6
6.5 Ingress Protection of Enclosure, IP Class ...........................................6
7 Safety Regulation ................................................................................6
8 Mechanical Data..................................................................................7
8.1 Dimensions..........................................................................................7
8.2 Weight .................................................................................................7
8.3 Mechanical Design ..............................................................................7
8.4 Surface Treatment...............................................................................7
9 ERICSSON Product Designation ........................................................8
10 Supply form .........................................................................................8
10.1 Delivery Items......................................................................................8
11 Packing................................................................................................8
12 Product List .........................................................................................8
13 Revision record ...................................................................................9

E:\temp\LBN-40B368AC-SS.doc
Open
DESCRIPTION 2 (9)
Prepared (also subject responsible if other) No.

EAB/JT/XU B Stensby 1555-SDC 901 08Uen


Approved Checked Date Rev Reference

EAB/JT/XU (Johan Blomqvist) 2004-03-23 A

1 Terminology
AC Altering Current
DC Direct Current
EAB Ericsson AB
NCC Node Communication Channel
MMU Modem Unit
MPH Modem Protective Housing
O&M Operation & Maintenance
OVP Over Voltage Protection
PSU Power Supply Unit
TBD To Be Defined

2 General
The MPH shall to be used as an enclosure for one MMU (2x2, 4x2/8 or
2x2-34+2) in the MINI-LINK systems.

3 Design and Performance


3.1 Functional Design

The MPH consists of the following functions:

• Shelter for one MMU

• Cooling systems (cooling fins and sun protection)

• Cable interface

• Support for mast and wall installation

E:\temp\LBN-40B368AC-SS.doc
Open
DESCRIPTION 3 (9)
Prepared (also subject responsible if other) No.

EAB/JT/XU B Stensby 1555-SDC 901 08Uen


Approved Checked Date Rev Reference

EAB/JT/XU (Johan Blomqvist) 2004-03-23 A

3.2 Cooling

Cooling fins on the rear side of the MPH provides cooling for one MMU.

3.2.1 Sun Protection

The MPH is provided with a Sun Protection Shield (see figure below).

The Sun Protection Shield protects the MPH from the effects of solar
radiation, in order to reduce the inside temperature.

Figure 3.2.1-1 Sun shield

E:\temp\LBN-40B368AC-SS.doc
Open
DESCRIPTION 4 (9)
Prepared (also subject responsible if other) No.

EAB/JT/XU B Stensby 1555-SDC 901 08Uen


Approved Checked Date Rev Reference

EAB/JT/XU (Johan Blomqvist) 2004-03-23 A

4 Electrical Characteristics
4.1 Grounding

The MPH case has connection for protective earth,


see paragraph 5.3.

5 Interface
5.1 External Interface

5.1.1 Mechanical Interface

The MPH can be mounted to a pole (mast) with a diameter of 50-120 mm by


using the Pole mount set.

It can also be mounted on a wall by using the Wall mount set.

Figure 5.1.1-1 Pole and wall mount set

E:\temp\LBN-40B368AC-SS.doc
Open
DESCRIPTION 5 (9)
Prepared (also subject responsible if other) No.

EAB/JT/XU B Stensby 1555-SDC 901 08Uen


Approved Checked Date Rev Reference

EAB/JT/XU (Johan Blomqvist) 2004-03-23 A


5.1.2 Electrical Interface

In the bottom of the MPH there is cable bushings for following type of cables
mounted in a the connector interface (lay-out see figure below):

• One DC cable (Ø 6-10 mm)

• One Traffic cable (Ø 6-10 mm)

• One NCC cable (Ø 6-10 mm) or similar

• One O&M cable (Ø 6-10 mm) or similar

• One Radio cable adapters (ERICSSON code RNT 1565)

Inside the MPH there is room for internal cabling to the MMU. It is possible to
tie the cables to the MPH.

The electrical interface has no extra Over Voltage Protection (OVP)


(Lightening Protection).

Figure 5.1.2-1 Connection Interface, lay-out

5.2 Internal Interface

Inside the MPH there is a mechanical interface (placed vertical) for the MMU.

5.3 Case Ground

Outdoor side:

Marking:

Mechanical interface: One M10 pin bolt to chassis. M10 nut with washer
is also provided. This is located near the cable
inlet to the MPH.

E:\temp\LBN-40B368AC-SS.doc
Open
DESCRIPTION 6 (9)
Prepared (also subject responsible if other) No.

EAB/JT/XU B Stensby 1555-SDC 901 08Uen


Approved Checked Date Rev Reference

EAB/JT/XU (Johan Blomqvist) 2004-03-23 A

6 Environmental Data
6.1 Temperature

Low temperature -33°C

High temperature +45°C (Solar radiation can also be added to this


requirement, See also paragraph 6.3)

6.2 Humidity

Relative humidity 8-100% Rh

6.3 Solar Radiation

Solar intensity max 1120W/m2

6.4 Wind

The equipment shall withstand following wind speed:

Operation: 50 m/s

Survival: 70 m/s

6.5 Ingress Protection of Enclosure, IP Class

The equipment shall be Ingress Proof according to IEC 60 529, IP 55.

• Degree 5 (first) protection against harmful ingress and deposits of


dust.

• Degree 5 (second) protection against splashing water from all


directions.

7 Safety Regulation
MPH complies with following safety regulations:

• EN 60 950

E:\temp\LBN-40B368AC-SS.doc
Open
DESCRIPTION 7 (9)
Prepared (also subject responsible if other) No.

EAB/JT/XU B Stensby 1555-SDC 901 08Uen


Approved Checked Date Rev Reference

EAB/JT/XU (Johan Blomqvist) 2004-03-23 A

8 Mechanical Data
8.1 Dimensions

The size of the MPH is 600x320x90 mm (HxWxD) (Support not included).

8.2 Weight

The weight of the MPH is 8 kg.

8.3 Mechanical Design

The MPH is equipped with a handle as a lifting point.

10x M5 screws lock the MPH cover.

8.4 Surface Treatment

The MPH is painted in following colour:

NCS S2502-R, grey. (According to NCS-gauge edition 2)

E:\temp\LBN-40B368AC-SS.doc
Open
DESCRIPTION 8 (9)
Prepared (also subject responsible if other) No.

EAB/JT/XU B Stensby 1555-SDC 901 08Uen


Approved Checked Date Rev Reference

EAB/JT/XU (Johan Blomqvist) 2004-03-23 A

9 ERICSSON Product Designation


The ERICSSON product designation is marked on each delivered unit:

SDC 901 08/X (Product Number) RXX. (R-State)

10 Supply form
10.1 Delivery Items

The delivery unit consists of following:

a A complete MPH

b Pole Mounting Set

c Wall Mounting Set

d Fixing bars for MMU

e Cable glands and Radio Cable Adapter

f Sun Shield

g One Station Radio Cable (Between MMU and Radio Cable Adapter.)

h Grounding kit for MPH

i MPH Installation Instruction

11 Packing
Each package includes a one MPH with its accessories according to
paragraph 10.1.

12 Product List

Product number Description

SDC 901 08/1 Modem Protection Housing (MPH)

E:\temp\LBN-40B368AC-SS.doc
Open
DESCRIPTION 9 (9)
Prepared (also subject responsible if other) No.

EAB/JT/XU B Stensby 1555-SDC 901 08Uen


Approved Checked Date Rev Reference

EAB/JT/XU (Johan Blomqvist) 2004-03-23 A

13 Revision record
Revision A:

First issue!

E:\temp\LBN-40B368AC-SS.doc