DESCRIPTION 1 (9)
Prepared (also subject responsible if other) No.
DESCRIPTION OF MPH,
(MODEM PROTECTIVE HOUSING).
Abstract
Contents
1 Terminology.........................................................................................2
2 General................................................................................................2
3 Design and Performance.....................................................................2
3.1 Functional Design................................................................................2
3.2 Cooling ................................................................................................3
3.2.1 Sun Protection.....................................................................................3
4 Electrical Characteristics .....................................................................4
4.1 Grounding............................................................................................4
5 Interface ..............................................................................................4
5.1 External Interface ................................................................................4
5.1.1 Mechanical Interface ...........................................................................4
5.1.2 Electrical Interface ...............................................................................5
5.2 Internal Interface .................................................................................5
5.3 Case Ground .......................................................................................5
6 Environmental Data .............................................................................6
6.1 Temperature........................................................................................6
6.2 Humidity ..............................................................................................6
6.3 Solar Radiation....................................................................................6
6.4 Wind ....................................................................................................6
6.5 Ingress Protection of Enclosure, IP Class ...........................................6
7 Safety Regulation ................................................................................6
8 Mechanical Data..................................................................................7
8.1 Dimensions..........................................................................................7
8.2 Weight .................................................................................................7
8.3 Mechanical Design ..............................................................................7
8.4 Surface Treatment...............................................................................7
9 ERICSSON Product Designation ........................................................8
10 Supply form .........................................................................................8
10.1 Delivery Items......................................................................................8
11 Packing................................................................................................8
12 Product List .........................................................................................8
13 Revision record ...................................................................................9
E:\temp\LBN-40B368AC-SS.doc
Open
DESCRIPTION 2 (9)
Prepared (also subject responsible if other) No.
1 Terminology
AC Altering Current
DC Direct Current
EAB Ericsson AB
NCC Node Communication Channel
MMU Modem Unit
MPH Modem Protective Housing
O&M Operation & Maintenance
OVP Over Voltage Protection
PSU Power Supply Unit
TBD To Be Defined
2 General
The MPH shall to be used as an enclosure for one MMU (2x2, 4x2/8 or
2x2-34+2) in the MINI-LINK systems.
• Cable interface
E:\temp\LBN-40B368AC-SS.doc
Open
DESCRIPTION 3 (9)
Prepared (also subject responsible if other) No.
3.2 Cooling
Cooling fins on the rear side of the MPH provides cooling for one MMU.
The MPH is provided with a Sun Protection Shield (see figure below).
The Sun Protection Shield protects the MPH from the effects of solar
radiation, in order to reduce the inside temperature.
E:\temp\LBN-40B368AC-SS.doc
Open
DESCRIPTION 4 (9)
Prepared (also subject responsible if other) No.
4 Electrical Characteristics
4.1 Grounding
5 Interface
5.1 External Interface
E:\temp\LBN-40B368AC-SS.doc
Open
DESCRIPTION 5 (9)
Prepared (also subject responsible if other) No.
In the bottom of the MPH there is cable bushings for following type of cables
mounted in a the connector interface (lay-out see figure below):
Inside the MPH there is room for internal cabling to the MMU. It is possible to
tie the cables to the MPH.
Inside the MPH there is a mechanical interface (placed vertical) for the MMU.
Outdoor side:
Marking:
Mechanical interface: One M10 pin bolt to chassis. M10 nut with washer
is also provided. This is located near the cable
inlet to the MPH.
E:\temp\LBN-40B368AC-SS.doc
Open
DESCRIPTION 6 (9)
Prepared (also subject responsible if other) No.
6 Environmental Data
6.1 Temperature
6.2 Humidity
6.4 Wind
Operation: 50 m/s
Survival: 70 m/s
7 Safety Regulation
MPH complies with following safety regulations:
• EN 60 950
E:\temp\LBN-40B368AC-SS.doc
Open
DESCRIPTION 7 (9)
Prepared (also subject responsible if other) No.
8 Mechanical Data
8.1 Dimensions
8.2 Weight
E:\temp\LBN-40B368AC-SS.doc
Open
DESCRIPTION 8 (9)
Prepared (also subject responsible if other) No.
10 Supply form
10.1 Delivery Items
a A complete MPH
f Sun Shield
g One Station Radio Cable (Between MMU and Radio Cable Adapter.)
11 Packing
Each package includes a one MPH with its accessories according to
paragraph 10.1.
12 Product List
E:\temp\LBN-40B368AC-SS.doc
Open
DESCRIPTION 9 (9)
Prepared (also subject responsible if other) No.
13 Revision record
Revision A:
First issue!
E:\temp\LBN-40B368AC-SS.doc