Abstract—Circulation is passage provided for ease of user. Usually
1) Space requrements: An easy way to identify
there are two types of circulation i.e. horizontal and vertical
stairs is to make them clearly visible. Stairs used for
circulation. Vertical circulation is one of the important component
commercial purposes should be at least 90 cm wide, have
in public building. It helps in vertical flow of user. For proper flight length of 12 steps, not exceed 40° in
a maximum
functioning of vertical circulation in public building orientation,
pitch, and avoid being flatter than 25°, with at least 2.14
space layout according to requirement of number of users and
meters of
materials is most important. Vertical circulation is categorized in headroom. A landing should not be narrower
different types depending on ease for public. Literature than
study it
andis wide; open risers can be confusing and
case study are done in detail to study about the vertical disconcerting
flow in for some people while avoiding spiral
commercial buildings. staircases in the event of tripping. A maximum of 60
people can pass through a 1525mm wide stairway
Keywords— vertical flow, steps, hoisting, powered stairs
according to the National Fire Protection Association's
''Life Safety Code”. Building height and purpose
determine the number of stair cases, so one stair case for
I. INTRODUCTION

C
23m.
IRCULATION, as usually applied in architecture, 2) Materials: Metal or timber stairs are noisy when
is the movement of people and goods between in use, while concrete stairs absorb more sound and the
interior spaces in buildings and to entrances and materials chosen will be based on a number of factors,
exits. Safe, convenient, rapid circulation is essential for all including cost, client preferences, location, structural
buildings under both normal and emergency conditions. requirements, and many more. Concrete stairs can be
Such circulation may be channeled through any of several crafted in situ using specialized formwork, followed by a
different types of passageways, such as lobbies, corridors, screed and polished, painted, or clad with another
ramps, stairways, and elevator hoist ways [1]. Having a
material. One can precast concrete stairs and assemble
vertical flow of traffic in a commercial building is crucial
them on site. In addition to metal stairs, metal balustrades
to its proper functioning, both in normal use and as a
can be made from light weight balusters or even mesh or
design feature. The placement of elevators and stairs
influences the design of the building, so consideration tension wires that give them a more industrial feel[3].
should be given to the type of vertical circulation, the B. Elevator
number of units needed, and their arrangement,
 As a hoisting and lowering mechanism, an elevator
arrangement, and design.
consists of a car or platform that travels along guides in a
Typically, commercial office buildings and apartment
shaft, or hoist way, in an approximately vertical direction,
buildings will reduce circulate space, so as to maximize
via a shaft or hoist way, to transport passengers or goods
the amount of rentable space or apartment interiors [2].
between two or more floors. A lift was first described by
Classification of vertical circulation system
Roman architect Vitruvius as being made of hemp rope
and powered by animals or people. An elevator contains
I. Stairs
hoist way, machine room, guide rails, elevator cars and so
II. Elevator
on.
III. Escalator
1) Space requirements: For public use, there should
A. Stairs be one lift on every four floors with a maximum distance
The stairs are a structure that allows individuals to pass of 45m to the lift lobby, and the floor space and car
between lower and higher levels by dividing a large capacity can be calculated by dividing each floor into
vertical distance into smaller vertical distances through a 0.2m2. It is easy for two passengers to enter and leave a
diagonal series of horizontal platforms referred to as car together with a 1075mm opening, as large passenger
steps that enable the passage of one level into another. As elevators (4000 lbs. and above) usually require 1225mm
evidenced by tower-like structures called pylons, ancient door openings, where 12.5% of the population uses them
Egyptians used them first. In a commercial building, during the 5-minute peak. It is classified as "excellent" if
vertical elevations connect the different levels with the the elevator interval is between 26 and 28 seconds;
help of several elements, such as landings, runs, steps, "good" if it is between 28 and 30 seconds; "fair" if it is
handrails, railings, and newel posts-all of which must be between 30 and 32 seconds; and "poor" if it is between 32
compliant with local standards. Usually, open tube well and 35 seconds. For greatest efficiency and lowest cost,
stairs and dog-leeged stairs usage are mostly seen in elevator group sizes should not exceed six elevators, with
public buildings for easy circulation of users four elevators per group as a more practical approach.
Since one cannot Buildings of up to 15000to 18000

XXX-X-XXXX-XXXX-X/XX/$XX.00 ©20XX IEEE


square meter frequently have only a single service depth of tread in direction of travel 400mm, maximum
elevator, whereas larger buildings are provided with two rise between treads is 200mm, width of tread is 600-
or more separate service cabs. 1000mm, maximum clearance between tread and adjacent
2) Types: According to Hoist Mechanism there is skirt panel is 10mm and maximum distance between
Hydraulic Passenger Elevator Hydraulic elevators where handrail centerlines—width between balustrades plus
elevators which are powered by a piston that travels 150mmwith not more than 75mm on either side of the
inside a cylinder and Traction/pulley passenger Elevator escalator. Speeds and Capacities Escalators typically
which consist of a lift car and a counterweight attached to operate at 25or 36m/min, as needed for peak traffic.
separate ends of a cable which travel over a large pulley Standard escalator widths are 800mm and 1150mm.
wheel called a Sheave at the top of the lift shaft.  Manufacturers rate their 25m/min units at corresponding
3) Materials:The elevator car itself is constructed capacities of 5000 and 8000 persons per hour, although
with a steel framework for durability and strength. A set observed capacities, even in heavy traffic, rarely exceed
of steel beams above the car, called the crosshead, span 2000 and 4000 persons per hour, respectively. Although
the elevator shaft from side to side and hold the pulley for 36m /min escalators will move about 30% more volume,
the hoist cable. A steel structure, called the sling, extends they are rarely specified because of the potential for
down the sides of the car from the crosshead and cradles adverse litigation. Structural Considerations in Escalator
the floor, or platform. The sides of a passenger elevator Installation Floor-to-floor height should be taken into
car are usually made from steel sheet and are trimmed on account in determining loads on supporting members.
the inside with decorative paneling. The floor of the car Generally, for floor-to-floor heights of less than 6m, the
escalator truss need be supported only at top and bottom.
may be tiled or carpeted. Handrails and other interior
Increased vertical rise can create the need for intermediate
trim may be made from stainless steel for appearance and
support points. A structural frame should be installed
wearability. A suspended ceiling is usually hung below
around the escalator well to carry the floor and well way
the actual top of the car and may contain fluorescent railing.
lighting above plastic diffuser panels. [4]. 2) Materials: The steps themselves are solid, one-
C. Escalator piece, die-cast aluminum. The hollow metal structure that
Escalators, or powered stairs, are used when it is joins the upper and lower landings is called the truss.
necessary to move large numbers of people from floor to Also, it carries tracks connecting both the upper and
floor. They provide continuous movement of persons and lower sections. [5].
can thus remedy traffic conditions that are not readily
REFERENCES
addressed by elevators. Escalators should be viewed as
[1] http://freeit.free.fr/Building%20Design&Construction
preferred transportation systems whenever heavy traffic %20Handbook,6ed/1999X_16.pdf
volumes are expected between relatively few floors. The [2] Vertical Circulation Design Manual NR/GN/CIV/200/05
earliest working type of escalator was patented in 1892 by [3] NFPA 101® Life Safety Code®
Jesse W. Reno, and was actually introduced in 1896 as a [4] http://www.madehow.com/Volume2/Elevator.
novelty ride at Coney Island, a theme park in New York. [5] https://buildingandinteriors.com/escalators-a-professionals-guide-
for-better-planning-installation
1) Space requirements: Maximum rise 6500mm
(NCE model) Dimensions for Escalators the minimum