SUBMITTAL AG015KSVAJH/AA
Samsung DVM Heat Pump Chiller
Job Name Location
Purchaser Engineer
Submitted to Reference Approval Construction
Unit Designation Schedule #
System Specifications
US Ton (nominal) 15 Construction
The unit shall be EGI (electronic galvanized steel) with a baked on powder coated
95°F Ambient, Entering Temperature: finish. Some brackets shall be GI (hot-dipped galvanized steel)
Cooling 168,000
54°F, Leaving Temperature: 44°F
Rated Leaving Temperature: 105°F 182,000 Air Side Heat Exchanger
Heating
Capacity The heat exchanger shall be mechanically bonded fin to copper tube.
(Dry/Wet Bulb: 47/43°F) Leaving Temperature: 120°F 171,000
(Btu/h)
Heating Leaving Temperature: 105°F 90,000 The aluminum fins of the heat exchanger shall have a protective coating.
(Dry/Wet Bulb: 17/15°F) Leaving Temperature: 120°F 85,000 Salt spray test method: ASTM B117-18 - the heat exchanger showed no
95°F Ambient, Entering Temperature: unusual rust or corrosion development to 2,280 hours.
Cooling 25.25
54°F, Leaving Temperature: 44°F
Water Side Heat Exchanger
Performance Power Heating Leaving Temperature: 105°F 22.40 The heat exchanger shall be brazed plate type (2)
Input (A) (Dry/Wet Bulb: 47/43°F) Leaving Temperature: 120°F 25.77
Controls
Heating Leaving Temperature: 105°F 17.72 The unit shall be operated via NASA Protocol with controls provided by Samsung
(Dry/Wet Bulb: 17/15°F) Leaving Temperature: 120°F 19.31
Can connect up to 16 X AG0**KSVA*H/AA DVM Chillers to a single DVM Chiller
Cooling EER 10.10 module controller (MCM-A00UN) to provide various system operation configuration,
Heating Leaving Temperature: 105°F 3.52 setup, monitoring, status, and error notification (MCM-A00UN is required for operation).
Heating (Dry/Wet Bulb: 47/43°F) Leaving Temperature: 120°F 2.87 The outdoor unit shall have a removable EEPROM that stores unit serial number,
COP Heating Leaving Temperature: 105°F 2.23 startup information, system settings, system tag/name, and other information.
(Dry/Wet Bulb: 17/15°F) Leaving Temperature: 120°F 1.95 Optional FCU Kit (fan coil unit) available to control and integrate fan coil units to
IPLV 18.80 Samsung central and local controls (FCU Kit: MIM-F00N; FCU Kit Central Control
Interface Module: MIM-F10N).
Voltage (ø/V/Hz) 3 / 460 / 60
Maximum Circuit Breaker (MCCB/ELB/ELCB) Controls shall integrate with a BMS system without additional interface modules
50
Power
Minimum Circuit Ampacity (MCA) 40 Control wiring shall be 16 AWG X 2 shielded wire (for communicating controls
SCCR kA 5 connections).

Type Inverter Driven Scroll X 2 Refrigerant System


Compressor The compressors shall be Samsung hermetically sealed, inverter driven, direct flash
RLA A 16.0 injected, DC scroll type with soft-start capability.
Refrigerant R410A Factory Charge Lbs. 40 The refrigerant system capacity shall modulate based on demand.
Connection Type 50A Cut Groove Flash injected compressors provide advanced low ambient heating performance.
Quantity 2
Refrigerant flow shall be controlled by EEV (electronic expansion valve).
Water Side Heat Minimum (cooling / heating) 16.8 / 16.8
Exchanger Water Flow (GPM) Nominal (cooling / heating) 33.6 / 33.6 Other Features
Asymmetrical scroll design with rotating compressor operation/priority.
Maximum (cooling / heating) 67.2 / 67.2
Minimum Water System Volume Gallons 100.8 Optional night quiet modes to reduce outdoor unit sound (default mode and levels 1-3)
with automatic or manual activation.
Type Propeller X 2
Fan Advanced intelligent defrost logic to significantly reduce defrost cycle frequency by
Output (max.) CFM 12,855
monitoring air resistance across the condenser coil during heating operation to
Type BLDC determine defrost operation initiation to prevent unnecessary defrost cycles. In
Condenser Fan
Motor Output W 630 X 2 applications where 2-16 modules are configured and controlled as one system, only
30% or less of the total nominal capacity will enter defrost operation at a time (ex: 6
FLA A 2.0 module system - only one module will defrost at a time; 8 module system - two modules
Max. External Static Pressure "WC 0.32 may enter defrost at a time).

WXHXD Inches 70 11/16 X 66 3/4 X 30 1/8 Optional snow blowing logic to prevent snow accumulation on idle units (enabled by
default, can be disabled at any time)
Dimensions Net Lbs. 959
Weight
Shipping Lbs. 1,008 Error reset with dry input at outdoor unit (refer to pages 4-5 for input/output details)

Sound Level Sound Pressure dB (A) 62 Three operation patterns can be selected: Standard, Rotation, and Efficiency (refer to
page 6 for details)
Operating Water Standard °F (°C) 41 ~ 77°F (5 ~ 25°C)
Cooling Operation patterns can be adjusted at DVM Chiller unit or at controllers (refer to page 7
Temperature When Using Brine °F (°C) 14 ~ 77°F (-10 ~ 25°C) for details)
Range Heating °F (°C) 77 ~ 131°F (25 ~ 55°C)
Energy savings options to reduce system energy consumption by configuring Water Law
Cooling °F (°C) 5 ~ 118°F (-15 ~ 48°C) control to automatically adjust leaving water set temperature based on ambient
Operating Ambient temperature or room temperature. Room temperature (heating and cooling, two points
Temperature Range each), outdoor temperature (heating and cooling, two points each), and water
Heating °F (°C) -13 ~ 109°F (-25 ~ 43°C)
temperature (heating and cooling, two points each) settings can be configured when
using Water Law control. Water Law can be based on outdoor temperature or indoor
Safety Certifications ETL (UL 1995)
temperature. Water Law based on room temperature requires installation of PT1000
temperature sensor (field provided) in the space to monitor room temperature (refer to
Intelligent logic to ensure proper operation within unit design limitations and operational parameters page 6 for details).
High pressure sensor, low pressure sensor, over-voltage protection, compressor over- current
Protection Devices protection, current transformer, fan motor voltage protection, fan motor thermal protection, overheat
protection, phase detection protection, high voltage fuses, water pressure sensors
Inverter PCB cooling done with liquid refrigerant to maintain optimal and safe operating temperatures

Performance is certified in accordance with the AHRI Air-Cooled Water-Chilling Packages Certification Program, which is
based on AHRI Standard 550/590 (I-P) and AHRI Standard 551/591 (SI). Heat Pump Water-Heating unit is certified
when operating in cooling. Certified units may be found in the AHRI Directory at www.ahridirectory.org. Combined
performance of multiple chillers are not AHRI Certified.
Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice.

© 20120 Samsung HVAC


SHA-DVMS-10152021 www.SamsungHVAC.com
Page 2 of 8
SUBMITTAL AG010KSVAFH/AA
Samsung DVM Heat Pump Chiller
Accessories, Control Points

Accessories
Qty. Model Number Description

WHG-T4 Top wind/hail guard

WHG-SL Left side wind/hail guard

WHG-SR Right side wind/hail guard

WHG-R1 Rear wind/hail guard (two required)

MCM-A00UN Module Controller for DVM Chiller

External contact control interface module (operation and error output, night silent
MIM-B14
mode manual activation)

Control Points
Below DVM Chiller control points are adjustable at the controllers/point of control noted below. Point of Control (X = supported)

Chiller module
Central control gateway
controller
DVM Chiller
dry contact
DMS2.5 BACnet LON
Control option MCM-A00UN
(MIM-D01AUN) (MIM-B17BUN) (MIM-B18BUN)

Operation ON/OFF X X X X X
Mode: cool, heat, cool storage, hot water X X X X X
Operation pattern: standard, rotation, efficiency X X
Enable/disable Water Law (adjustable temperature settings of Water Law) X1 X X X2
Enable/disable quiet mode (default mode and quiet mode levels 1-3 are selected during
X1 X X X2
system commissioning)
Forced fan mode X X X X
Demand/maximum current control of module chiller(s): limit current 50% - 100% of design
X1 X X X
2
current
1
The setting value is adjustable on MCM-A00UN service mode.
2
Adjust the setting value on Hydro controller option setting on DVM Chiller unit

888-699-6067
www.SamsungHVAC.com
Page 3 of 8
SUBMITTAL AG015KSVAJH/AA
Samsung DVM Heat Pump Chiller
Dimensional Drawing

70 11/16"

65 1/8"

35 5/16"

30 9/16"
30 1/8"
10"

70 11/16"

66 3/4"
4 1/2"
7 1/16"
7 9/16"

9 1/16" 6"
19 1/16" 8 15/16"

65 1/8"
30 9/16"

No. Description No. Description


1 Water connections 5 Communication wiring conduit opening (side)
2 Power wiring conduit opening (front) 6 Anchor bolt hole

3 Power wiring conduit opening (side) 7 PCB monitoring window


4 Communication wiring conduit opening (front)

Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice.
www.SamsungHVAC.com
Page 4 of 8
SUBMITTAL AG015KSVAJH/AA
Samsung DVM Heat Pump Chiller
Output Contacts

2XWSXWFRQWDFW for individual DVM Chiller units

A-T/B (terminal block: A)

                   

1R 1DPH 6LJQDO )XQFWLRQ &RQWDFW6KRUW &RQWDFW2SHQ


'LVSOD\sZKHQRSHUDWingLQ
 &RROLQJ+HDWLQJGLVSOD\ +HDW &RRO
 heat PRGH
 2SHUDWLRQGLVSOD\ 'LVSOD\sZKile system isRSHUDWing 2SHUDWH 6WRS
 :DUQLQJGLVSOD\ =HUR 'LVSOD\sZKHQHUURURFFXUV (UURURFFXUUHG 1RHUURU
 'HIURVWRSHUDWLRQGLVSOD\ 'LVSOD\sZKHQGHIURVWLQJ 'HIroVW21 'HIURVW2))
YROWDJH
 3XPSRSHUDWLRQGLVSOD\ 'LVSOD\sZKHQSXPSRSHUDWHV 3XPS21 3XPS2))
$7%
 &RPSressorRSHUDWLRQGLVSOD\ FRQWDFW 'LVSOD\sZKHQFRPSUHVVRU RSHUDWHV &RPSUHVVRU21 &RPSUHVVRU2))
 3XPSRSHUDWLRQ 6LJQDORISXPSRSHUDWLRQ 3XPSVLJQDO21 3XPSVLJQDO2))
 )UHH]HSURWHFWLRQGLVSOD\ 'LVSOD\sZKHQIUHH]HSURWHFWLRQ 3XPS21IRUIUHH]H 2WKHUV
is enabled SURWHFWLRQ
 Not used    
 Not used    
Refer to technical data book and installation manual for complete operation and control details.

([DPSOHRIRXWSXWFRQWDFWLQVWDOODWLRQ

2XWSXWWHUPLQDOEORFN in DVM Chiller

3RZHU $&RU'&

''&

([WHUQDOFRQWUROOHU ''&'LUHFW'LJLWDO&RQWURO
5HIHUWRWKHPDQXDOSURYLGHGZLWKWKHH[WHUQDOFRQWUROOHUIRUdetails

/DPSRURXWSXWORDG
)LHOGVFRSH (not Samsung HVAC)

Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice.
www.SamsungHVAC.com
Page 5 of 8
SUBMITTAL AG015KSVAJH/AA
Samsung DVM Heat Pump Chiller
Input Contacts

,QSXWFRQWDFWs

B-T/B (terminal block: B)

                   

&RQWDFW 6LJQDO 6HWWLQJ


1R 1DPH 6LJQDO )XQFWLRQ &RQWDFW6KRUW
2SHQ UHFRJQLWLRQ XQLW

1 Not used      

Pump operation signal


‡ 3XPSLQWHUORFNHUURU (
 3XPSLQWHUORFN 3XPS21 3XPS2)) 8VXDOLQSXW (DFKXQLW
RFFXUVLIiQSXWis not on ZKHQ 1RWH 2

RSHUDWLQJSXPS
 8VXDOLQVWDQW 0DLQXQLW
1RWe 3)
2SHUDWLRQ212)) &RQWUROOLQJRSHUDWLRQ212)) 1RWH 5
LQSXW RIJURXS
 1RWH 2 1RWH 6)

0DLQXQLW
 2SHUDWLRQPRGH 6HOHFWLQJFRROKHDWPRGH
1RWH 4)
+HDW &RRO 8VXDOLQSXW RIJURXS
1RWH 2
1RWH 6
%7%
(QWHULQJKRWZDWHU FRROVWRUDJH 
+RWZDWHU 0DLQXQLW
=HUR PRGHE\H[WHUQDOFRQWURO &RROVWRUDJH 8VXDOLQSXW
 &RROVWRUDJH mode &RRO+HDW 1RWH 2
RIJURXS
1RWH 1
YROWDJH ‡ &RRO21&RROVWRUDJH +RWZDWHU 1RWH 6
FRQWDFW ‡ +HDW21+RWZDWHU
&RQWUROGHSHQGLQJRQVHW
+RWZDWHU WHPSHUDWXUHZKHQ21 0DLQXQLW
&RROVWRUDJH &RQWUROE\VHW &RQWUROE\ 8VXDOLQSXW
 &RQWUROGHSHQGLQJRQH[WHUQDOKRW 1RWH 2
RIJURXS
FRQWUROVWDQGDUG WHPSHUDWXUH WKHUPRVWDW 1RWH 6
ZDWHU FRROVWRUDJH WKHUPRVWDW
1RWH 1
ZKHQ2))

:KHQWKHUPRVWDWLVVHWDVVWDQGDUG
+RWZDWHU
IRUKRWZDWHU FRROVWRUDJH PRGH 0DLQXQLW
&RROVWRUDJH 8VXDOLQSXW
 ‡ 7KHUPR21ZKHQ21 1RW over 7KHUPR21 7KHUPR2)) 1RWH 2 RIJURXS
WKHUPRVWDWVLJQDO range of water outlet temperature 1RWH 6)
1RWH 1
‡ 7KHUPR2))ZKHQ2))

Note 1) 7RXVHKRWZDWHU FRROVWRUDJH PRGHWKHIXQFWLRQVKRXOGEHDFWLYDWHGE\0RGXOH&RQWUROOHU (MCM-A00UN)


Note 2) Input types:
- 8VXDOLQSXW2SHUDWHE\FXUUHQWVWDWXVRIFRQWDFW (switch).
- Instant input: Operate when contact signal changes from OFF to ON / from ON to OFF (push button).
1RWH 3 2SHUDWHVZKHQLQSXWPHWKRGRIoSHDUDWLRQ2Q2IILVVHWDVH[WHUQDOFRQWDFW

1RWH 4 2SHUDWHVZKHQLQSXWPHWKRGRIRSHUDWLRQPRGHLVVHWDVH[WHUQDOFRQWDFW
1RWH 5 2SHUDWLRQGHSHQGLQJRQH[WHUQDOFRQWDFWRSHUDWLRQ212))LQSXWPHWKRG

:KHQVHWDVXVXDOLQSXW  2SHUDWLRQ21ZKHQLV212))ZKHQLV2))
:KHQVHWDVLQVWDQWLQSXW  2SHUDWLRQ21ZKHQLV21PRUHWKDQVHFRQG2))ZKHQLV21PRUHWKDQVHFRQG
1RWH 6 0DLQXQLWRIPRGXOHZKHQJURXSLVQRWDYDLODEOH

Refer to technical data book and installation manual for complete operation and control details.

Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice.
www.SamsungHVAC.com
Page 6 of 8
SUBMITTAL AG015KSVAJH/AA
Samsung DVM Heat Pump Chiller
Input Contacts (continued)

C-T/B (terminal block: C)

                   

&RQWDFW &RQWDFW 6LJQDO 6HWWLQJ


1R 1DPH 6LJQDO )XQFWLRQ
6KRUW 2SHQ UHFRJQLWLRQ XQLW
0DLQXQLW
2SHUDWHTXLHWIXQFWLRQLQOHYHOVHWE\ 4XLHW 8VXDOLQSXW
 4XLHWIXQFWLRQ  1RWH 9
RIJURXS
PDLQRSWLRQRUPRGXOHFRQWURO1RWH  IXQFWLRQ 1RWH 

2SHUDWHGHPDQGIXQFWLRQ FXUUHQW 0DLQXQLW


'HPDQG 8VXDOLQSXW
 'HPDQGIXQFWLRQ OLPiWFRQWURO atOHYHOVHWE\PDLQ  RIJURXS
IXQFWLRQ 1RWH 9
=HUR
RSWLRQRUPRGXOHFRQWURO1RWH  1RWH 

YROWDJH
0DLQXQLW
)RUFHGIDQ FRQWDFW )RUFHGIDQ 8VXDOLQSXW
 2SHUDWHIRUFHGIDQIXQFWLRQ1RWH   RIJURXS
IXQFWLRQ IXQFWLRQ 1RWH 9
1RWH 

8QXVXDO 5HVHWerrorVWDWXV
,QVWDQWLQSXW 0DLQXQLW
 FRQGLWLRQ(error) ‡ 2SHUDWHVRQO\ZKHQUHPRWHHUURU 5HVHWHUURU 
UHVHW
1RWH 9 RIPRGXOH
UHVHWLQSXWIXQFWLRQLVenabled
 Not used  Not used (N/A)    

&7% :DWHUODZ :DWHU


=HUR 0DLQXQLW
 (refer to page 6 YROWDJH 2SHUDWHZDWHUODZ1RWH 
:DWHUODZ RXWOHWVHW 8VXDOLQSXW RIJURXS
for details) FRQWURO WHPSHUDWXUH 1RWH 9
1RWH 
FRQWDFW
FRQWURO
 Not used  Not used 1$    
 Not used  Not used (N/A)    
5HFRJQL]HZDWHURXWOHWVHW temperature 
6HWWHPSHUDWXUH
by external input aP$ 1RWH  0DLQXQLW
URRP $QDORJ 5HFRJQL]HYDOXHRIURRPWHPSHUDWXUH
   &XUUHQWLQSXW RIJURXS
WHPSHUDWXUH FXUUHQW VHQVRU aP$ ZKHQVWDQGDUGIRU 1RWH 
VHQVRU ZDWHUODZLVURRPWHPSHUDXWUH1RWH 
([WHUQDO 5HFRJQL]HH[WHUQDOZDWHURXWOHW 0DLQXQLW
$QDORJ
 ZDWHURXWOHW WHPSHUDWXUHE\H[WHUQDOWHPSHUDWXUH   &XUUHQWLQSXW RIJURXS
FXUUHQW
WHPSHUDWXUH VHQVRU aP$ 1RWH  1RWH 

1RWH 
 Refer to technical data book for more details and sensor information
1RWH 2
 Refer to technical data book for more details and sensor information
1RWH 3
 If operation pattern is not standard control, control standard temperature depends on external water outlet temperature sensor. External water outlet temperature
sensor should be installed where it can represent the temperature of the water pipe system. Refer to technical data boook for full details.
1RWH 
 2SHUDWHVZKHQLQSXWPHWKRGIRUTXLHWIXQFWLRQLVVHWDVH[WHUQDOFRQWDFW
,IWKHFRQWDFWLVclosed (short)TXLHWIXQFWLRQRSHUDWHVLQ&RRO+HDWPRGH
4XLHWIXQFWLRQE\0RGXOH&RQWUROOHURSHUDWHVLQ&RROPRGHDQGQLJKWWLPH
1RWH 
2SHUDWHVZKHQLQSXWPHWKRGIRUGHPDQGIXQFWLRQLVVHWDVH[WHUQDOFRQWDFW
1RWH 
2SHUDWHVZKHQLQSXWPHWKRGIRUIRUFHGIDQIXQFWLRQLVVHWDVH[WHUQDOFRQWDFW
1RWH 
2SHUDWHVZKHQLQSXWPHWKRGIRUZDWHUODZIXQFWLRQLVVHWDVH[WHUQDOFRQWDFW
1RWH 
0DLQXQLWRIPRGXOHZKHQJURXSLVQRWDYDLODEOH
Note 9) Input types:
- 8VXDOLQSXW2SHUDWHE\FXUUHQWVWDWXVRIFRQWDFW (switch).
- Instant input: Operate when contact signal changes from OFF to ON / from ON to OFF (push button).
NOTE: 5RRPWHPSHUDWXUHDQGH[WHUQDOZDWHURXWOHWWHPSHUDWXUHVHQVRUsareQRWVXSSOLHG3XUFKDVH and install the appropriate sensor according to the usage.
5RRPWHPSHUDWXUHVHQVRUP$ƒ& ƒ) P$ƒ& ƒ)
([WHUQDOZDWHURXWOHWWHPSHUDWXUHVHQVRUaP$ P$ƒ& -ƒ) P$ƒ& ƒ)

Refer to technical data book and installation manual for complete operation and control details.
Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice.
www.SamsungHVAC.com
Page 7 of 8
SUBMITTAL AG015KSVAJH/AA
Samsung DVM Heat Pump Chiller
Water Law Details

Water Law Details


Water Law standards can be configured for cooling and heating operating mode. Water law can be enabled to change the water outlet temperature based on demand
load changes according to outdoor or indoor temperature.

Water Law configuration according to outdoor temperature

Set temperature

Set temperature
Theat1
Tcool1 Water temperature Water temperature

Tcool2 Theat2

AirCool1 AirCool2 AirHeat1 AirHeat2


Outdoor temperature Outdoor temperature
Cool Mode Heat Mode
NOTE:
If the unit is not a low temperature water model, the set temperature decided by the Water law control will not decrease below 41°F.

Tcool1, Tcool2, AirCool1, AirCool2, AirHeat1, and AirHeat2 will be configured at the DVM Chiller unit during system commissioning
or at controllers noted above.

Water Law configuration according to indoor temperature (when using an external temperature sensor)
Set temperature

Set temperature

Theat1
Tcool1 Water temperature Water temperature

Tcool2 Theat2

RoomCool1 RoomCool2 RoomHeat1 RoomHeat2


Indoor temperature Indoor temperature
Cool Mode Heat Mode

NOTE:
If the unit is not a low temperature water model, the set temperature decided by the Water law control will not decrease below 41°F.

Tcool1, Tcool2, RoomCool1, RoomCool2, RoomHeat1, and RoomHeat2 will be configured at the DVM Chiller unit during system
commissioning or at controllers noted above.

Refer to technical data book and installation manual for complete operation and control details.
Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice.
www.SamsungHVAC.com
Page 8 of 8
SUBMITTAL AG015KSVAJH/AA
Samsung DVM Heat Pump Chiller
Operation Patterns

Standard Control
yAll modules start operating at the same time, and each module operates in the operation pattern which set in the installation service mode.
– The default for each module is Standard control.

Unit 0 Unit 1 Unit 2 Unit 3 Unit 0 Unit 1 Unit 2 Unit 3

Operation of all units Pressure Pressure Pressure Pressure


control control control control

NOTE:
Standard control is suited for applications that always has a high cooling and heating load factor.

Rotation Control
yDVM CHILLER’s water outlet temperature is controlled according to the water outlet temperature average value of all operating units in a module. However, if you set “Use” for an
external water temperature sensor, it controls the water outlet temperature according to a temperature value from the sensor.
yModules in a group operate in Standard control.
yThe module with the highest priority starts operating first, and if the module reaches full load, a module with the following priority will start operating.
yWhen the module with the lowest priority operates at the minimum capacity and the water outlet temperature reaches close to the set temperature, the compressors of the module stop.

Module 1 Module 2 Module 1 Module 2

Unit 0 Unit 1 Unit 2 Unit 3 Unit 0 Unit 1 Unit 2 Unit 3

Start operating all units in Start operating all units in


the module Full load operation the module

NOTE:
Rotation control is suited for applications that have lower capacities at load side while starting a DVM CHILLER and has small fluctuation in momentary load.

Efficiency Control
yDVM CHILLER’s water outlet temperature is controlled according to the water outlet temperature average value of all operating units in a module. However, if you set “Use” for an
external water temperature sensor, it controls the water outlet temperature according to a temperature value from the sensor.
yOnly one unit with the highest priority operates, and if the unit operates with the optimum efficiency, a unit with the following priority will operate.
yWhen all units reach efficient operating condition, each unit operates at capacity between efficient operating condition and the maximum capacity condition.
yWhen all units reach efficient operating condition and the water outlet temperature reaches close to the set temperature, the unit with the lowest priority controls decrease compressor
operating capacity.

Unit 0 Unit 1 Unit 2 Unit 3 Unit 0 Unit 1 Unit 2 Unit 3

Operation Pressure
of 1 unit Operation with efficient Hz Off
control

Efficient
operating
condition

NOTE: Unit 0 Unit 1 Unit 2 Unit 3


• Efficiency control is suited for applications that has both an operating section with
the low load and a focused operating time.
Maximum
capacity Pressure Pressure Pressure Pressure
• When all units operate with the optimum efficiency, they control the pressure of
condition control control control control
their compressors in a range between higher than efficient Hz and lower than full
load Hz separately.
Efficient
– Efficient Hz means the most efficient Hz (speed) of inverter. operating
condition

Refer to technical data book and installation manual for complete operation and control details.
Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice.
www.SamsungHVAC.com