Fire Damage Assessment

Additional Information
ej

Inputs

Options
Code of Construction ASME Section VIII, Division 1

Conditions
Pressure Type Internal
Design Pressure 250.0 psig
Design Temperature 325.0 °F

Geometry
Geometry Cylinder

Dimensions
Inside Diameter 48.0 in
Wall Thickness 1.0 in
Future Corrosion Allowance 0.0 in
Metal Loss 0.0 in
Structural Tmin Basis API 579 Fitness-For-Service

Material Properties
Material Specification SA516, 60, 2011, K02100, ---, ---, Default
Pipe Undertolerance No
Circumferential Weld Efficiency 1.0
Longitudinal Weld Efficiency 1.0

Fire Damage Characterization


Tensile Stress Basis Estimate tensile stress from a Brinell hardness
Hardness Test Value 152.0

Page 1 of 2 Version: @e2grnd/calculator-ui@5.0.0, ID: q1HD5rrNx5iSScPo8yxw2I 04/13/2023 03:07:02 PM


Fire Damage Assessment

Results

Notes
The calculated MAWP based on the fire damaged material properties, corroded thickness, and specified temperature
exceeds the specified pressure.

Acceptance Criteria
Maximum Allowable Working Pressure (MAWP) 695.1 psi
MDMT Based on MAWP -3.0 °F
Retirement Thickness 0.3634 in

Estimated Fire Damaged Properties


Code Room Temperature Allowable 17100.0 psi
Code Design Temperature Allowable 17100.0 psi
Estimated Fire Damaged Tensile Stress 80000.0 psi
Final Allowable Stress 17100.0 psi

Applicability and Limitations


* The equipment being evaluated must be constructed to a recognized code or standard.

* The maximum operating temperature of the component does not exceed 650.00 (F).

* The component material must have sufficient toughness. If there is uncertainty regarding the material toughness, then a
brittle fracture assessment should be performed.

* The Part 11 Fire Damage assessment is only valid for components that may have experienced a reduction in material
tensile stress due to elevated temperature. Evaluations for other types of damage such as distortion, cracking, metal loss,
or creep may be evaluated per the appropriate Part in API 579.

Page 2 of 2 Version: @e2grnd/calculator-ui@5.0.0, ID: q1HD5rrNx5iSScPo8yxw2I 04/13/2023 03:07:02 PM