LABORATORY
GENERAL CHEMISTRY 2
GRADUATED CYLINDER
ACID BURETTE
•SECURE THE BURETTE ON THE IRON STAND WITH A
CLAMP. ENSURE IT IS PERFECTLY VERTICAL AND
THERE IS ENOUGH CLEARANCE TO POSITION THE
CONICAL FLASK BELOW.
•FULLY OPEN THE STOPCOCK AND RINSE THE INNER
SURFACE WITH THE ACID SOLUTION TO BE USED.
REPEAT THE PROCESS A FEW TIMES WITH A FUNNEL.
•CLOSE THE STOPCOCK, FILL THE BURETTE WITH THE
ACID SOLUTION UNTIL THE STARTING MARK. PLACE
THE ANALYTE FLASK UNDER THE BURETTE.
•OPEN THE STOPCOCK AND LET THE TITRANT FLOW
UNTIL A FEW MILLILITERS BELOW THE THEORETICAL
AMOUNT. RESTRICT THE FLOW TO A DROP EVERY FEW
SECONDS AND STOP WHEN THE INDICATOR ACTIVATES.
GENERAL CHEMISTRY 2
ALKALINE BURETTE
•SECURE THE BURETTE ON THE IRON STAND WITH A CLAMP.
ENSURE IT IS PERFECTLY VERTICAL AND THERE IS ENOUGH
CLEARANCE TO POSITION THE CONICAL FLASK BELOW.
•REMOVE THE BURETTE CLAMP AND RINSE THE INNER
SURFACE WITH THE ALKALI SOLUTION TO BE USED. REPEAT
THE PROCESS A FEW TIMES WITH A FUNNEL.
•ATTACH THE BURETTE CLAMP, FILL THE BURETTE WITH
THE ALKALI SOLUTION UNTIL THE STARTING MARK. PLACE
THE ANALYTE FLASK UNDER THE BURETTE.
•OPEN THE BURETTE CLAMP AND LET THE TITRANT FLOW
UNTIL A FEW MILLILITERS BELOW THE THEORETICAL
AMOUNT. RESTRICT THE FLOW TO A DROP EVERY FEW
SECONDS AND STOP WHEN THE INDICATOR ACTIVATES.
GENERAL CHEMISTRY 2
BEAKER
CONICAL FLASK
•RINSE THE FLASK WITH
DISTILLED WATER.
ALWAYS USE A FLASK
WITH A SIGNIFICANTLY
LARGER CAPACITY THAN
THE LIQUID TO BE
POURED.
•MIX THE CONTENTS OF
THE FLASK BY SWIRLING
THE LIQUID BY HAND.
•WHEN PLUGGING THE
OPENING, CHOOSE A
SLIGHTLY WIDER GLASS,
RUBBER, OR CORK PLUG.
GENERAL CHEMISTRY 2
DISTILLATION FLASK
•ATTACH A UTILITY AND RING
CLAMP TO THE CLAMP STAND.
PLACE A WIRE GAUZE ABOVE
THE RING CLAMP. SECURE
THE DISTILLATION FLASKS
WITH THE CLAMPS.
•INSERT THE NARROW TUBE
IN THE CONDENSER. POUR
THE SOLUTION INSIDE.
•PLUG THE MAIN OPENING
WITH A STOPPER WITH
THERMOMETER AND HEAT
THE SOLUTION WITH THE
BUNSEN BURNER.
GENERAL CHEMISTRY 2
CONDENSER TUBE
•SECURE THE CONDENSER TUBE TO BE
PERFECTLY CENTER AND PARALLEL TO THE
NARROW TUBE OF THE DISTILLATION FLASK.
PLACE A CLEAN CONICAL FLASK BY THE
CONDENSATE OUTLET.
•CONNECT THE LOWER COOLANT TUBE TO
THE WATER SUPPLY WITH A RUBBER TUBE.
CONNECT A RUBBER TUBE TO THE COOLANT
OUTLET TUBE AND DIRECT THE USED
WATER TO THE DRAIN.
GENERAL CHEMISTRY 2
•STERILIZE THE
INOCULATING LOOP BY
PASSING IT OVER THE FLAME
OF AND ALCOHOL LAMP. LET
IT AIR COOL FOR A FEW
SECONDS BEFORE DIPPING IT
IN THE MICROBIAL SAMPLE.
GLASS ROD
PASTEUR PIPETTE
•ATTACH THE RUBBER BULB TO THE
PIPETTE. DO NOT INSERT THE
PIPETTE ALL THE WAY.
•SQUEEZE THE RUBBER BULB AND
INSERT THE LOWER TIP OF THE
PIPETTE TO THE LIQUID. SLOWLY
RELEASE THE BULB TO SIPHON THE
LIQUID. DO NOT LET THE LIQUID GO
PAST THE INDENT MARK OF THE
PIPETTE.
GENERAL CHEMISTRY 2
WATCH GLASS
•SMALL AMOUNT OF
MATERIALS CAN BE
PLACED ON TOP FOR
USING IN CHEMICAL
REACTIONS.
•THE WATCH GLASS
CAN BE USED TO COVER
THE BEAKER OR FLASK
DURING HEATING OR
CHEMICAL REACTION.
GENERAL CHEMISTRY 2
SPOT PLATE
EVAPORATING DISH
•PLACE THE MIXTURE
TO BE DRIED OUT IN
THE EVAPORATING
DISH.
•PLACE THE
EVAPORATING DISH
ON THE BURNER
STAND WITH WIRE
GAUZE.
•KEEP THE DISH
UNDER HEAT UNTIL
ALL OF THE LIQUIDS
EVAPORATE. USE A
TONG FOR HANDLING.
GENERAL CHEMISTRY 2
BUNSEN BURNER
•ENSURE THAT THE NEEDLE VALVE AND
AIR COLLAR ARE COMPLETELY CLOSED.
•CONNECT THE BURNER TO THE GAS
SUPPLY. OPEN THE GAS VALVE FULLY
•OPEN THE NEEDLE VALVE BY A
QUARTER OF A ROTATION. USING A
LONG-NOZZLE LIGHTER, IGNITE THE
BURNER.
•ADJUST THE HEIGHT AND COLOR OF
THE FLAME USING THE NEEDLE VALVE
AND AIR COLLAR. THE BURNER SHOULD
HAVE A BLUE STEADY FLAME.
GENERAL CHEMISTRY 2
CRUCIBLE TONGS
THERMOMETER