Professional Documents
Culture Documents
E+h Eia251
E+h Eia251
RIA251
Process display Digital, loop-powered display for 4 to 20 mA current loops
Features and benefits 5-digit LC display with 0.66" (17 mm) character height Loop-powered display, no additional power supply wiring required Measuring range of -19999 to 99999 Flexible measurement range setup using 3 push buttons Hazardous certification: FM IS, Class I, Division 1, Groups A, B, C, D CSA IS, Class I, Division 1, Groups A, B, C, D ATEX II 1 G EEx ia IIC T6
Application Plant and machine construction Control panels Laboratory fittings Temperature display and monitoring Process display and monitoring Suitable for hazardous applications
2140
TI063R/24/ae
RIA251
Application Example
RIA251 with required power taken directly from the current loop; shown with recorder, PLC, etc.
250 Ohm
L/L
GND N/L
md mdsd .sad fd af sa d sa . al s a s a
********
rabm 253 C 0
EVAS
PLEH
6
eteleD
egaP pU pskB
9
egaP nO &%# CBA etsaP LKJ
1C
ypo IHG
5 nI
tres VUT
4
SRQP
8
><_
)(,
/*+
573
ROTACINU
M M O C DL
EI F
ENDRESS+HAUSER RIA251
HART handheld terminal DXR375 (available from Endress+Hauser) Temperature sensor with electronic insert TMT181 / TMT182
Hazardous Area
Input
Input types Measurement ranges Maximum input current Voltage drop HART protocol Current 4 to 20 mA, polarity protected 150 mA, short circuit current <2V Display is suitable for transmitting HART protocol
Accuracy
Current < 0.1% of FSD Temperature drift, 0.01% / 10 K ambient temperature
Installation conditions
Installation angle No limit
RIA251
-4 to +140 F (-20 to +60 C) -22 to +158 F (-30 to +70 C) To EN 60654-1 Class B2 Between front bezel and panel: NEMA 4 (IP 65) Terminals; NEMA 1 (IP 20) general purpose To EN 55011 Group 1, Class A To EN 61000-4-2, 6 kV/8 kV To EN 61000-4-3, 10 V/m To EN 61000-4-4, 4 kV
Mechanical construction
Dimensions
Weight Materials
10.6 oz (0.3 kg) Housing front, die cast aluminum Casing, galvanized sheet steel Rear panel, ABS plastic
Identification label
Power supply
Electrical connection Plug on screw terminals (securable), 1.5 mm2 terminal size for 16 AWG solid wire or 1.0 mm2 for 17 AWG stranded wire.
Explosion hazardous area
ENDRESS+HAUSER RIA251
Non-hazardous area
ENDRESS+HAUSER RIA251
+ E
+ E
- Intrinsically safe +
loop power supply
I -
I -
Both the terminals and the connection values of the display correspond to the hazardous location requirements. Note: The display can be placed into the hazardous area if a suitable barrier is used.
FM CSA ATEX
Ordering information
Product structure
RIA251 Process display
Certification
A B C D F Version for non hazardous areas ATEX II 1G EEx ia IIC T6 FM IS, Class I, Div. 1, Groups A, B, C, D CSA IS, Class I, Div. 1, Groups A, B, C, D NEPSI Ex ia IIC T6
Housing
1 2 Panel mounting, 3.78" x 1.89" x 3.54" (96 x 48 x 90 mm) Factory calibration certificate, panel mounting 1.89" x 3.78" x 3.54" (48 x 96 x 90 mm) Order code
RIA251-
United States Endress+Hauser, Inc. 2350 Endress Place Greenwood, IN 46143 USA Tel. 317-535-7138 Fax 317-535-8498 Sales 888-ENDRESS Service 800-642-8737 inquiry@us.endress.com www.us.endress.com
Canada Endress+Hauser Canada 1075 Sutton Drive Burlington, ON L7L 5Z8 Canada Tel. 905-681-9292 800-668-3199 Fax 905-681-9444 www.ca.endress.com
Mexico Endress+Hauser, Mxico, S.A. de C.V. Fernando Montes de Oca 21 Edificio A, Piso 3, San Nicols Tlalnepantla Edo. de Mxico. C.P. 54030 Mxico Tel.: +52 (55) 5321-2080 Fax: +52 (55) 5321-2080 eh.mexico@mx.endress.com www.mx.endress.com
InstrumentsInternational Endress+Hauser Instruments International AG Kaegenstrasse 2 4153 Reinach Switzerland Tel. +41 61 715 81 00 Fax +41 61 715 25 00 www.endress.com info@ii.endress.com