Download as pdf or txt
Download as pdf or txt
You are on page 1of 11

UNIVERSITY OF ENGINEERING AND TECHNOLOGY

LAHORE (NAROWAL CAMPUS)

(Renewable Energy)

Complex Engineering Problem


(CEP)

Submitted to:
Engr. Adnan Bashir
Submitted by:
Muhammad Owais (2019-EE-616)

Department of Electrical Engineering


University of Engineering & Technology Lahore – Narowal Campus
Department of Electrical Engineering (NRWL)
COMPLEX ENGINEERING PROBLEM (CEP)
Course Title: EE-452: Renewable Electrical Energy Systems

Marks/Weightage: 12%
Time/Duration: 01 Week

CLOs and PLOs Mapping for CEP:

Domain/
CLO Description Domain Taxonomy PLO
MAPPING

Level

Design of a stand-alone power generation


CLO3 system using these renewable energy Cognitive 4-Analyze PLO3
technologies.

Statement: Design a stand-alone PV system for your own house. Suppose that your
house is in an area in which winter temperature drops to −20 ºC. The monthly insolation
data for the area in which your house is located is given in TABLE-1. While, TABLE-2
and TABLE-3 give the data/x-tics of PV modules and batteries for different
manufacturers respectively, you can choose the data of any module and battery as per
your design requirement when sizing battery storage and PV array. Design your system
with 95% system availability for 90% Coulomb efficiency, and 0.90 de-rating factor. And
also draw your design with specifying components ratings and accurate value of outputs
at various stages of the system.

Submission Guidelines:
• Each student shall submit solution separately.
• Submit your work in PDF format.
• The report should contain all the calculations, characteristics curves and data
used, block diagram of your design and any assumptions if made.
• Plagiarized reports will be marked zero.
• Give description of your house i.e. size and number and types of rooms etc.
in start of your design/report.
• Make sure, you are computing the power demand of your own house
assuming a realistic load, otherwise you will lose marks.
TABLE-1: Monthly Insolation Data.

TABLE-2: Module Performance Data Under STC for Different Manufacturers.

TABLE-3: Deep-Cycle (80%) Lead-Acid Battery X-tics/Data for Different


Manufacturers.
Complex Engineering Problem Attributes and Characteristics

Attributes Characteristics
1 Preamble Engineering problems which cannot be resolved without
in-depth engineering knowledge, much of which is at, or
informed by, the forefront of the professional discipline, Yes
and have some or all of the following characteristics
listed below.
2 Depth of knowledge Requires research-based knowledge much of which is
required at, or informed by, the forefront of the professional
Yes
discipline and which allows a fundamentals-based, first
principles analytical approach.
3 Depth of analysis Have no obvious solution and require abstract thinking, Yes
required originality in analysis to formulate suitable models.
4 Range of conflicting Involve wide-ranging or conflicting technical, engineering Yes
requirements and other issues.
5 Familiarity of issue Involve infrequently encountered issues.
6 Extent of applicable Are outside problems encompassed by standards and
codes codes of practice for professional engineering
7 Extent of stakeholder Involve diverse groups of stakeholders with widely
involvement and level varying needs.
of conflicting
requirement
8 Consequences Have significant consequences in a range of context

9 Interdependence Are high level problems including many component parts Yes
or sub-problems.
CEP Assessment Rubrics

Marks Distribution
Criteria Poor Average Good Excellent
(0-30)% (31-60)% (61-80)% (81-100)%
House description (i.e. size Not or Partially given Correctly Correctly
and number and types of wrongly given given with
rooms etc.) is given in start given map
of your design/report.
Load estimation assuming Incorrectly Calculated Correctly Correctly
a realistic load calculated with many calculated calculated
mistakes with one or
two mistakes
Inverter sizing and system Incorrectly Calculated Correctly Correctly
voltage selection calculated with many calculated calculated
with wrong mistakes with with one or with accurate
selection of accurate two mistakes selection of
system selection of with accurate system
voltage system selection of voltage
voltage system
voltage
Battery Sizing Incorrectly Calculated Correctly Correctly
calculated with many calculated calculated
mistakes with one or
two mistakes
PV Sizing Incorrectly Calculated Correctly Correctly
calculated with many calculated calculated
mistakes with one or
two mistakes
Design Not given Wrongly given Correctly Correctly
Layout/Configuration and without output given but given with
Output Specification at specification without output output
different Stages specification specification
at all stages
Scanned with CamScanner
Scanned with CamScanner
Scanned with CamScanner
Scanned with CamScanner
Scanned with CamScanner
Scanned with CamScanner

You might also like