Cooling Fan
AC Input
DC Input
DC Input
DC Input
DC Input
Stall Alarm
42 52 60 80
62
Filter
AC Input
AC Input DC Input
AC Input DC Input Low-Speed Alarm
Fans 50 60 80 100
129×134
180×180
AC Input
AC Input
161×158
AC Input DC Input
DC Input
2
*
Axial Fans
AC Input
AC Input
AC Input
AC Input DC Input Stall Alarm
AC Input
AC Input
AC Input DC Input Low-Speed
DC Input Alarm
DC Input
Long-Life
Variable Flow
Splash Proof
Frame Size
mm
AC Input
AC Input AC Input
DC Input DC Input
Low-Speed Alarm AC Input Low-Speed Alarm
DC Input
Impeller Diameter Impeller Length
mm Low-Speed Alarm mm
Thermostat Accessories
IP43/55 IP43/55 ✽See specific part number for the agency approvals on our Oriental Motor website.
3
For a Wide Variety of Roles: Cooling, Drying, Air Flow, Ventilation and More. Axial Fans
AC Input
Standard Long-Life
MU Series MRE Series Low-Speed Alarm
Conform to the UL, CSA and EN Standards Achieved an expected life of 100,000 hours.
and also have the CE Marking affixed
(The conformity differs according to the
product.)
140 mm up to 250 mm
Max Air Flow = 883 CFM
DC Input
42 mm up to 172 mm 62 mm up to 172 mm
Max Air Flow = 349 CFM Max Air Flow = 212 CFM
Long-Life
MDE Series Stall Alarm
60 mm up to 172 mm
Max Air Flow = 226 CFM
4
Low-Speed Alarm : Low-Speed Alarm Type Stall Alarm : Stall Alarm Type ➜ For details about alarm function, refer to the Alarm on 6.
Degree of Protection IP43/ IP55 AC Input DC Input Low-Speed Alarm Stall Alarm Application Example
Thermostat
Enclosure Fan
(Suction Type)
Finger Guard Slit Metal Plate Dust and Water Resistant
IP2X Type IP4X Type IP43/ IP55 Type
AC Input DC Input
50 60 80 80 100 120
100 120 160
AC Input DC Input
5
Use with a Fan for Energy Saving and Temperature Control.
Thermostat
Achieve energy reduction and noise AM2-XA1 (°C)
reduction with the ON/OFF control. ●Unlimited settings within the 0∼60°C temperature range.
Automatically starts and stops the fan motor in ●Separate power supply not required
accordance with the temperature fluctuations inside the ●Supports DIN rail
equipment. Because the fan motor operates only when ●Compact design: Width 33 mm×Height 70 mm×
cooling is needed, this is effective in reducing both energy Thickness 42.5 mm
consumption and noise levels. ●A single thermostat can control multiple fans. For details,
see our Oriental Motor website.
When the fan activation temperature is set to 40˚C, and the fan turns ON due to temperature rise inside the enclosure
45
(Fan operates)
②
Set Temperature 40˚C
40
(Operating temperature = set temperature) ①Contact OFF (fan stopped) Temperature rise inside
enclosure
① ③ ②Contact ON (fan operates) Temperature inside enclosure is
Reset Temperature 36˚C
36 [Reset temperatures = operating temperature 40˚C (operating temperature)
35 ④ −4°C] ③Contact ON (fan operates) Temperature inside enclosure
Contact OFF at Reset Temperature falls
(Fan stops)
④Contact OFF (fan stops) Temperature inside enclosure is
Time [s] 36˚C (reset temperature)
Notification of Decreased Fan Motor Cooling Performance Contributes to Increased Device Reliability.
Alarm
Low-Speed Alarm Fans with Low-Speed Alarms
When the fan motor's speed drops to 70% or less of the rated
Low-Speed Alarm Output Detection
speed due to fan motor deterioration or ingression of a foreign before
stopping!
object, an alarm is output to the host controller.
Host Controller
Host Controller
0 r/min
Low-Speed
Alarm Signal Alarm Output
Host Controller
Host Controller
Rated Speed
Stalled
0 r/min
Stall Alarm
Signal Stall Alarm Output
6
Fan Kits
●Axial Fans ●Centrifugal Blowers
Accessories such as finger guards (or filters), power supply cables, mounting
brackets and screws, are packaged together as a single set. This allows use of
the fan straight out of the box.
✽Contents of sets differs by fan motor.
Accessories
●Finger Guard ●Filters/ Metallic Filters ●Screen ●Plug Cords for Connection to
Power Supply
●Finger Guard Cover Panels ●Finger Guard Cover Panels ●Slit Metal Cover Panels ●Dust and Water Resistant
(IP2X) (IP2X) with Filter (IP4X) Cover Panels with Filter
7
● The factories which manufacture the products listed in this catalogue have obtained Quality
Safety Precautions Management Systems ISO9001 and Environment Management Systems ISO14001.
● The content listed in this catalogue such as performance and specifications of the products are
● To ensure correct operation, carefully read the Operating Manual before using it. subject to change without notice for improvements.
● The products listed in this catalogue are for industrial use and for built-in ● The price of all products listed in this catalogue does not include the consumption tax etc.
● For details of the products, please contact the nearest dealer, sales office or the following “Order
component. Do not use for any other applications. Support Center” or “Customer Support Center”.
● is registered trademark or trademark of Oriental Motor in Japan and other countries.
ORIENTAL MOTOR ASIA PACIFIC PTE. LTD. ORIENTAL MOTOR (MALAYSIA) SDN. BHD.
31 Kaki Bukit Road 3, #04-02/04 Headquarters & Kuala Lumpur Office
Techlink, Singapore 417818 A-13-1, North Point Offices, Mid Valley City,
TEL: +65-6745-7344 FAX: +65-6745-9405 No.1 Medan Syed Putra Utara 59200
http://www.orientalmotor.com.sg/ Kuala Lumpur, Malaysia
TEL: +60-3-22875778 FAX: +60-3-22875528
ORIENTAL MOTOR (THAILAND) CO., LTD.
Penang Office
Headquarters & Bangkok Office 1-4-14 Krystal Point II, Lebuh Bukit Kecil 6, Bayan Lepas,
900, 8th Floor Zone C, Tonson Tower, Ploenchit Road, 11900 Penang, Malaysia
Lumpini, Pathumwan, Bangkok 10330 Thailand TEL: +60-4-6423788 FAX: +60-4-6425788
TEL: +66-2-251-1871 FAX: +66-2-251-1872
Lamphun Office
238/4 Moo 4, Tambol Ban-Klang, Customer Support Centre
Amphur Muang, Lamphun 51000 Thailand TEL: For Singapore: 1800-8420280 (Toll Free)
TEL: +66-(0)53-582-074 FAX: +66-(0)53-582-076 For Malaysia: 1800-806161 (Toll Free)
http://www.orientalmotor.co.th/ For Thailand: 1800-888881 (Toll Free)
For Other Countries: +65-6842-0280
ORIENTAL MOTOR (INDIA) PVT. LTD. Mail to: support@orientalmotor.com.sg
No.810, 8th Floor, Prestige Meridian-1 No.29,
Japanese Customer Support Centre
M.G.Road, Bangalore, 560001, India
TEL: +91-80-41125586 FAX: +91-80-41125588 TEL: +65-6745-3008
http://www.orientalmotor.co.in/ Mail to: j-support@orientalmotor.com.sg