Inverter Integrato Trifase Pe
Inverter Integrato Trifase Pe
250
Inverter PC board must be fed at 230 V ± 15% - 50/60 Hz o 400 V ± 15% - 50/60Hz directly on fastons labelled with letters "L1" "L2" "L3" and
connected to the earth. Just to avoid current over absorption speed drive varation comes from voltage/frequency of the motor itself. Speed control
is made by an acceleration/decelleration check-up to avoid sudden varations may cause problems. Possible and sudden breaks of
voltage/frequency are registred by the monitoring circuit to guarantee motor stability. Stop function ramping is guided during feeding interruption
but speed is reset when feeding is on .Is possible to insert a resistance for brake the motor, for used this option insert resistance between BRAKE
pin.
INPUT SEGNAL
the inverter's controles are in the J7 connecting terminal .Following you have all description:
• +10V reference output • Motor's direction 89forwand/reverse)
• Analogue input, voltage range 0-10Vdc • Start to run motor
• 0 Vdc ground l/0 • Fault reset
• Digital input (voltage max 5V current 1mA ≤ l ≤ 3,5 mA) • Digital input (voltage max 5V current 1mA ≤ l ≤ 3,5 mA)
OUTPUT SIGNAL
The inverter's controles are in the J2 connecting terminal .Following you have all description: