E1/T1 INTERFACE PLUG-IN CARD

FOR Alstom e-DXC


Enhanced Digital Cross-connect
USER'S MANUAL
12 JUNE 2012 Version 5
TABLE OF CONTENTS

1 PRODUCT DESCRIPTION ........................................................................................................................ 1


1.1 APPLICATION ILLUSTRATIONS ................................................................................................................. 2
1.2 PRODUCT SPECIFICATIONS .................................................................................................................... 3
2 INSTALLATION ......................................................................................................................................... 4
2.1 MECHANICAL INSTALLATION ................................................................................................................... 4
2.2 ELECTRICAL INSTALLATION .................................................................................................................... 4
3 OPERATION .............................................................................................................................................. 7
4 E/T1 SETUP PROCEDURE....................................................................................................................... 8
4.1 MENU TREE .......................................................................................................................................... 8
4.2 INITIAL SETUP AND CARD REGISTRATION ................................................................................................ 9
4.3 CHOOSING A TRIB UNIT ....................................................................................................................... 12
4.4 CONFIGURATION SETUP ....................................................................................................................... 14
4.4.1 Channel Line Interface Setup Procedure................................................................................... 15
4.4.2 Trace Message & EPSL Setup Procedure ................................................................................ 16
4.4.3 Customer Information Setup Procedure .................................................................................... 17
4.4.4 RDI Mode Setup Procedure....................................................................................................... 18
4.4.5 TPSG Protection Mode Setup Procedure.................................................................................. 19
4.4.6 TPSG Protection Switch Setup Procedure ................................................................................ 20
4.4.7 LIU HighZ Setup ........................................................................................................................ 21
4.5 ALARM SETUP ..................................................................................................................................... 22
4.5.1 Alarm Mask and Relay Setup Procedure................................................................................... 23
4.5.2 Alarm Severity Setup Procedure ............................................................................................... 23
4.5.3 Insert AIS Alarm Setup .............................................................................................................. 25
4.6 LOOPBACK AND DIAGNOSTICS SETUP ................................................................................................... 26
4.6.1 Channel Loopback Setup Procedure......................................................................................... 27
4.6.2 Unit Diagnostics Setup Procedure............................................................................................. 28
4.7 PERFORMANCE SETUP/CLEAR ............................................................................................................. 29
4.7.1 Unit Clear Performance Data Procedure ................................................................................... 30
4.7.2 Unit Performance Threshold Setup Procedure.......................................................................... 30
4.7.3 Line Monitor Framer Setup Procedure ...................................................................................... 31
4.8 FILE TRANSFER ................................................................................................................................... 32
4.8.1 Unit Download Firmware Procedure.......................................................................................... 33
4.9 SNCP/UPSR APS SETUP .................................................................................................................. 35
4.9.1 SNCP/UPSR APS Command .................................................................................................... 35
4.9.2 SNCP/UPSR Revertive Setup ................................................................................................... 36

LIST OF TABLES
Table 3- 1 LED Indication for E1/T1 Card ................................................................................................. 7

Table 4- 1 Channel Line Interface setting Options.................................................................................. 15


Table 4- 2 Trace Message Setup and EPSL Setting Options #1 ............................................................ 16
Table 4- 3 Trace Message Setup and EPSL Setting Options #2 ............................................................ 16
Table 4- 4 RDI Mode Setup Setting Options........................................................................................... 18
Table 4- 5 TPSG Protection Mode Setting Options ................................................................................ 19
Table 4- 6 TPSG Protection Switch Setting Options............................................................................... 20
Table 4- 7 Unit Alarm Mask and Relay Setting Options #1..................................................................... 23
Table 4- 8 Unit Alarm Mask and Relay Setting Options #2..................................................................... 23
Table 4- 9 Unit Alarm Severity Setting Options....................................................................................... 24
Table 4- 10 Insert AIS Alarm Setting Options.......................................................................................... 25
Table 4- 11 Channel Loopback Setting Options...................................................................................... 27
Table 4- 12 Optical Line Alarm Mask/Relay Setting Options 2 ............................................................... 28
Table 4- 13 Channel Diagnostics Setting Options #2 ....................................................................... 28
Table 4- 14 Unit Performance Threshold Setting Options ...................................................................... 30
Table 4- 15 Line Monitor Framer Setting Options #1.............................................................................. 31
Table 4- 16 Line Monitor Framer Setting Options #2.............................................................................. 31
LIST OF FIGURES
Figure 1- 1 E1(75 ohm) 16, 32 and 63 Port Interface Cards .................................................................... 1
Figure 1- 2 E1(120 ohm)/T1 16, 32 and 63 Port Interface Cards ............................................................. 1
Figure 1- 3 Card Based 1:1 and Port Based 1:1 Protection .................................................................... 2
Figure 1- 4 Line 1+1 Protection ................................................................................................................ 2
Figure 4- 1 E1/T1 Interface Card Menu Tree............................................................................................ 8
D Bitte führen Sie das Gerät am Ende seiner Lewbensdauer den zue Verfügung
stehended Rückgabeund Sammelsystemen zu.

GB At the end of the product's useful life, please dispose of it at appropriate collection
points provided in your country

F Une fois le produit en fin devie, veuillez le déposer dans un point de recyclage
approprié.

ES Para preservar el medio ambiente, al final dela vida útil de su producto, depositelo
en los laguares destinado aello de acuerdo con la legislación vigente.

P No final de vida útil do producto, por favor coloque no ponto de recolha apropriado.

I I Onde tutelare l'ambiente, non buttate l'apparecchio trai i normali rifiuti al termine
della sua vita utile, ma portatelo presso i punti DI RACCOLTA specifici per questi
rifiuti previsti dalla normativa vigente.

NL Wij raden u aan het apparant aan het einde van zijn nuttige levensduur, niet bij hey
gewone huisafval te deponeren, maar op de dearvoor bestemde adressen.

DK Når produktet er udtjent, bor det børtskaffes via de sæ rlige indsamlingssteder i


landet.

N Ved slutten av produktets levetid bør det avhendes på en kommunal miljøstasjon


eller leveres til en elektroforhandler.

S Lämna vänligen in produkten på lämplig återvinningsstation när den är förbrukad.

FIN Hävitä tuote käytöiän päättyessä viemällä se asianmukaiseen keräyspisteeseen.

PL Gdy produkt nie nadaje sie juz do dalszego uzytku, nalezy zostawic go w jednym ze
specjalnych punktów zajmujacych sie zbiórka zuzytych producktów w wybranych
miejscach na terenie kraju.

CZ Po skončení jeho životnosti odložte prosím výrobek na přislušném sbĕrném místé


zřízeném dle předpisů ve vaší zemi.

SK Po skončení jeho životnosti odovzdajte prosím zariadenie na príslušnom zbernom


mieste podía platných miestnych predpisov a noriem.

SLO Ko se izdelku izteče življenska doba, ga odnesite na ustrezno zbirno mesto oziroma
ga odvrzite v skladu z veljavnimi predpisi.

GR Στο Тέλος тης λειτουργικής Ζωής του προϊόντος παρακαλώ


Πετξτε το στα ειōικά σημεία που Παρέχονται οτη χωρα σας.

PRC 當產品使用壽命結束,請在你的國家所提供的適當地點做好回收處理
Chapter 1 Product Description

1 Product Description
The E1/T1 Interface Card is a software selectable plug-in card. Depending upon manufacturing options
there are Nx E1/T1 ports available, where N=16/32/63TE or 16/32/63E75. The card is hot-pluggable and can
be installed in or removed from an e-DXC chassis when the e-DXC device is powered up.

Note: The 75 ohm E1 card is an E1 card only. It is not configurable as a T1 card.

Figure 1- 1 E1(75 ohm) 16, 32 and 63 Port Interface Cards

Figure 1- 2 E1(120 ohm)/T1 16, 32 and 63 Port Interface Cards

1
Chapter 1 Product Description

1.1 Application Illustrations

Tributary Protection
Switching Group #1

E1/T1 Card E1/T1 Card


Trib #1 Trib #2

TX standby line in high


impedance mode

Out of the two E1/T1 ports


on the card only one TX
will be accepted
Y-Box

RX signal is fed into both


Trib #1 and Trib #2

Two tributary cards service


a single tributary line

Figure 1- 3 Card Based 1:1 and Port Based 1:1 Protection

E1/T1 Card E1/T1 Card


Trib #1 Trib #2

Working Standby

Figure 1- 4 Line 1+1 Protection

2
Chapter 1 Product Description

1.2 Product Specifications


E1 Interface
Line Rate 2.048 Mbps ± 50 ppm Jitter ITU G.823
Line Code AMI/HDB3 Framing Unframed with a framing monitor on
receiving side
Input Signal ITU G.703 Impedance 75 ohm coax/120Ω twisted pair
Output Signal ITU G.703 Connector SCSI-II 68-pin
One connector for 16 ports
Two connectors for 32 ports
Four connectors for 63 ports
Output Mask ETS 300 689 Sec.4.2.1.2 ITU
G.703

T1 Interface
Line Rate 1.544 Mbps ± 32 ppm Jitter ITU G.824
Line Code AMI/B8ZS Framing Unframed with a framing monitor on
receiving side
Input Signal ITU G.703 DSX-1 0dB to –6dB Impedance 100 ohm twisted pair
Output Signal ITU G.703 DSX-1 w/short (0-110, Connector SCSI-II 68-pin
110-220, 220-330, 330-440, 440- One connector for 16 ports
550, 550~660 feet) Two connectors for 32 ports
Four connectors for 63 ports
Output Mask Bellcore GR-499-core

3
Chapter 2 Installation

2 Installation

2.1 Mechanical Installation

The E1/T1 interface card will plug into any tributary slot in the e-DXC chassis. E1/T1 interface cards are hot
swappable.

2.2 Electrical Installation


All electrical connections are on the backplane. The electrical connections are made when the card is firmly
seated into a tributary slot in the e-DXC chassis.

E1/T1 SCSI 68 E1 SCSI 68 E1/T1


Pin Number Pin Number Signal Pin Number Port Number
(Port 1-16) ( Port 17~32 )
15 Tx Tip 15
16 Tx Ring 16
1 17
49 Rx Tip 49
50 RX Ring 50
13 Tx Tip 13
14 Tx Ring 14
2 18
47 Rx Tip 47
48 RX Ring 48
11 Tx Tip 11
12 Tx Ring 12
3 19
45 Rx Tip 45
46 RX Ring 46
9 Tx Tip 9
10 Tx Ring 10
4 20
43 Rx Tip 43
44 RX Ring 44
7 Tx Tip 7
8 Tx Ring 8
5 21
41 Rx Tip 41
42 RX Ring 42
5 Tx Tip 5
6 Tx Ring 6
6 22
39 Rx Tip 39
40 RX Ring 40
3 Tx Tip 3
4 Tx Ring 4
7 23
37 Rx Tip 37
38 RX Ring 38
1 Tx Tip 1
2 Tx Ring 2
8 24
35 Rx Tip 35
36 RX Ring 36
31 Tx Tip 31
32 Tx Ring 32
9 25
65 Rx Tip 65
66 RX Ring 66

4
Chapter 2 Installation

E1/T1 SCSI 68 E1 SCSI 68 E1/T1


Pin Number Pin Number Signal Pin Number Port Number
(Port 1-16) ( Port 17~32 )
29 Tx Tip 29
30 Tx Ring 30
10 26
63 Rx Tip 63
64 RX Ring 64
27 Tx Tip 27
28 Tx Ring 28
11 27
61 Rx Tip 61
62 RX Ring 62
25 Tx Tip 25
26 Tx Ring 26
12 28
59 Rx Tip 59
60 RX Ring 60
23 Tx Tip 23
24 Tx Ring 24
13 29
57 Rx Tip 57
58 RX Ring 58
21 Tx Tip 21
22 Tx Ring 22
14 30
55 Rx Tip 55
56 RX Ring 56
19 Tx Tip 19
20 Tx Ring 20
15 31
53 Rx Tip 53
54 RX Ring 54
17 Tx Tip 17
18 Tx Ring 18
16 32
51 Rx Tip 51
52 RX Ring 52
Table 2-1 E1/T1 SCSI 68 Pin Assignment (Port 1~32)

E1/T1 SCSI 68 E1/T1 SCSI 68 E1/T1


Pin Number Pin Number Signal Pin Number Port Number
(Port 33-48) ( Port 49 ~ 63 )
15 Tx Tip 15
16 Tx Ring 16
33 49
49 Rx Tip 49
50 RX Ring 50
13 Tx Tip 13
14 Tx Ring 14
34 50
47 Rx Tip 47
48 RX Ring 48
11 Tx Tip 11
12 Tx Ring 12
35 51
45 Rx Tip 45
46 RX Ring 46
9 Tx Tip 9
10 Tx Ring 10
36 52
43 Rx Tip 43
44 RX Ring 44

5
Chapter 2 Installation

E1/T1 SCSI 68 E1 SCSI 68 E1/T1


Pin Number Pin Number Signal Pin Number Port Number
(Port 33-48) ( Port 49 ~ 63 )
7 Tx Tip 7
8 Tx Ring 8
37 53
41 Rx Tip 41
42 RX Ring 42
5 Tx Tip 5
6 Tx Ring 6
38 54
39 Rx Tip 39
40 RX Ring 40
3 Tx Tip 3
4 Tx Ring 4
39 55
37 Rx Tip 37
38 RX Ring 38
1 Tx Tip 1
2 Tx Ring 2
40 56
35 Rx Tip 35
36 RX Ring 36
31 Tx Tip 31
32 Tx Ring 32
41 57
65 Rx Tip 65
66 RX Ring 66
29 Tx Tip 29
30 Tx Ring 30
42 58
63 Rx Tip 63
64 RX Ring 64
27 Tx Tip 27
28 Tx Ring 28
43 59
61 Rx Tip 61
62 RX Ring 62
25 Tx Tip 25
26 Tx Ring 26
44 60
59 Rx Tip 59
60 RX Ring 60
23 Tx Tip 23
24 Tx Ring 24
45 61
57 Rx Tip 57
58 RX Ring 58
21 Tx Tip 21
22 Tx Ring 22
46 62
55 Rx Tip 55
56 RX Ring 56
19 Tx Tip 19
20 Tx Ring 20
47 63
53 Rx Tip 53
54 RX Ring 54
17 Tx Tip
18 Tx Ring
48
51 Rx Tip
52 RX Ring
Table 2-2 E1/T1 SCSI 68 Pin Assignment (Port 33~63)

6
Chapter 3 Operation

3 Operation
LED Indication for E1/T1 Card
LED Color Indication
ACTIVE Off Off
Flashing Green Working E1/T1 card
Flashing Amber Standby E1/T1 card
Red Card is unregistered

TEST Off Neither loopback nor diagnostics exist


Flashing Amber Card self-test, Loopback or diagnostics exist
Flashing Red Chip initialization failed

ALM This LED is used to indicate alarm status:TU-LOP, TU-AIS, LP-UNEQ, LP-PLM,
LP-TIM, LP-RDI-P, LP-RDI-S, LP-RDI-C, LP-V5-REI, LP-V5-BIP, LOS, AIS, UAS,
RAI/YEL ... all paired alarms about SDH/SONET.
Red Critical alarm message or Major alarm message occurs
Amber Minor alarm message occurs
Green Informative alarm message or no alarm message occurs

E1 Indicator Off T1
Green E1
Table 3- 1 LED Indication for E1/T1 Card

7
Chapter 4 E/T1 Setup Procedure

4 E/T1 Setup Procedure


The E1/T1 card can be set up as either E1 or T1. This chapter provides detailed setup instructions.

Please note that Tributary cards must be registered with the e-DXC device or you will not be able to access
their detailed menu screens. The card registration procedure is detailed in Section 4.2 of this manual.

4.1 Menu Tree


Menu tree shown below is for both E1 and T1 Modes.

Figure 4- 1 E1/T1 Interface Card Menu Tree

8
Chapter 4 E/T1 Setup Procedure

4.2 Initial Setup and Card Registration


Prior to setting up an E1/T1 Interface Card you must first set up the main e-DXC device. Full instructions for
doing so are found in the e-DXC User’s Manual. After that setup is complete go to the main Controller Menu
for the e-DXC device. A sample screen is shown below.

You must register your E1/T1 cards with the e-DXC device.
Press N to register the unit (ie. register your card).
e-DXC === Controller Menu === 10:21:29 11/07/2008

Serial Number : 000022 Device Name : e-DXC


Hardware Version: C Start Time : 09:31:00 11/07/2008
Software Version: V1.01.02 10/24/2008 Connect Port : SUPV_PORT

[DISPLAY] [SETUP]
C -> System Config Display S -> System Config Setup
D -> SDH/SONET Display H -> SDH/SONET Setup
J -> PDH Display K -> PDH Setup
P -> Map Display G -> Map Setup
Q -> Alarm Queue M -> Alarm Setup
I -> System Information L -> File Transfer
T -> System Log V -> Store/Retrieve Backup Config
N -> Unit Registration

[LOG] [MISC]
F -> Log Off Y -> Alarm Cut Off
O -> Log On Z -> Reset
U -> Choose a Trib Unit X -> Clear Alarm Queue
W -> Return to Default

>>SPACE bar to refresh or enter a command ===>

The following screen will appear. The slot location of any card in the device shows up on the screen.
Choose the command “Card Registration” and press Enter. The model name “E1-75ohm” represents 75ohm
E1 interface, and “E1” represents 120ohm E1 interface. Choose “Card Registration” to start the register
process.
e-DXC === Unit Registration === 10:23:10 02/10/2010
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

SL. REG. Model/Mode Card Model Software Version Remark


=== ===================== ================ =================== =============
#1 E1-75ohm-PRTD(63Port) E1-75ohm(63Port) V1.02.02 03/23/2009
#2
#3 E1-NP(63Port) E1/T1(63Port) V1.03.03 12/09/2009
#4
(PRTD = Protected, NP = No Protection)
=== ===================== ================ =================== =============
#11
#12
#13
#14
#15
#16

Command : Card Registration

<< Press ESC key to return to previous menu >>

9
Chapter 4 E/T1 Setup Procedure

Use the Tab key to scroll in the Tributary slot that your E1/T1 card is plugged into. Press the Enter key.
Command : Card Registration
Unit : Trib-4
Note that the model of card will appear. Move the cursor to the Registered Model field and scroll in either the
E1 or T1 setting. Press the Enter key.
Command : Card Registration
Unit : Trib-4
REG. Model/Mode : E1-PRTD(63Port)
A registration prompt will appear as the registration takes place.
Registration......SUCCESS!
After registration, the E1/T1 card information will show on the screen:
e-DXC === Unit Registration === 10:23:10 02/10/2010
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

SL. REG. Model/Mode Card Model Software Version Remark


=== ===================== ================ =================== =============
#1 E1-75ohm-PRTD(63Port) E1-75ohm(63Port) V1.02.02 03/23/2009
#2
#3 E1-NP(63Port) E1/T1(63Port) V1.03.03 12/09/2009
#4 E1-PRTD(63Port) E1/T1(63Port) V1.03.03 12/09/2009
(PRTD = Protected, NP = No Protection)
=== ===================== ================ =================== =============
#11
#12
#13
#14
#15
#16

Command : Card Registration

<< Press ESC key to return to previous menu >>

If you have other cards to register do it now. Each plug-in interface card must be registered separately.

Change Protection Mode:


You do not need to de-register the card to change the protection mode. Simply use the command “Change
Protection Mode”. You can change the card’s protection mode from NP (without protection) to PRTD (with
protection), or vise-versa.

10
Chapter 4 E/T1 Setup Procedure

Card De-registration:
To de-register a card, please activate the command “Card Un-registration”. The setup procedure is similar to
that of “Card registration”.
Note: If you want to change a registered card from E1 toT1 or vice-versa, you must de-register the card and
re-register it again.
e-DXC === Unit Registration === 10:23:10 02/10/2010
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

SL. REG. Model/Mode Card Model Software Version Remark


=== ===================== ================ =================== =============
#1 E1-75ohm-PRTD(63Port) E1-75ohm(63Port) V1.02.02 03/23/2009
#2 E1-75ohm-PRTD(63Port)
#3 E1-PRTD(63Port) E1/T1(63Port) V1.03.03 12/09/2009
#4 E1-PRTD(63Port)
(PRTD = Protected, NP = No Protection)
=== ===================== ================ =================== =============
#11
#12
#13
#14
#15
#16

Command : Card Un-registration

<< Press ESC key to return to previous menu >>

11
Chapter 4 E/T1 Setup Procedure

4.3 Choosing a Trib Unit


Press U from the e-DXC Controller Menu to select the Tributary slot that E1/T1 card is plugged into.
e-DXC === Controller Menu === 11:30:22 04/25/2007

Serial Number : 010523 Device Name : e-DXC


Hardware Version: D Start Time : 11:26:28 04/25/2010
Software Version: V1.01.01 03/19/2007 Connect Port : SUPV_PORT

[DISPLAY] [SETUP]
C -> System Config Display S -> System Config Setup
D -> SDH/SONET Config Display H -> SDH/SONET Config Setup
I -> System Information M -> Alarm Setup
Q -> Alarm Queue L -> File Transfer
B -> Currently-Active Alarm Summary V -> Store/Retrieve Backup Config
A -> Current Alarm Status G -> Loopback/Diagnostics Setup
P -> SDH/SONET Performance R -> Performance Setup/Clear
T -> System Log N -> Unit Registration
E -> Diagnostics Display

[LOG] [MISC]
F -> Log Off Y -> Alarm Cut Off
O -> Log On Z -> Reset
U -> Choose a Trib Unit X -> Clear Alarm Queue
W -> Return to Default

>>SPACE bar to refresh or enter a command ===>

A prompt will appear. Use the Tab key to scroll in the card’s Tributary slot number. Press the Enter key.
==>> Press Tab key to select the unit: 4

The unit menu will appear for that card. If the unit you select is a 120ohm E1 card, the model name on the
upper left of the screen shows “E1”.
Unit 1 E1 === Unit Menu === 18:00:09 09/02/2011

HW Version : C Card State : Initialization Completed


SW Version : V1.05.01 11/18/2010

[DISPLAY] [SETUP]
C -> Config Display S -> Config Setup
B -> SNCP/UPSR Status M -> Unit Alarm Setup
Q -> Currently-Active Alarm Summary G -> Loopback & Diagnostics Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance L -> File Transfer
K -> Diagnostics Display D -> SNCP/UPSR APS Setup

[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu

>>SPACE bar to refresh or enter a command ===>

12
Chapter 4 E/T1 Setup Procedure

If the unit you select is a 75ohm E1 card, the model name on the upper left of the screen shows “E1-75ohm”.
Unit 1 E1-75ohm === Unit Menu === 18:20:50 02/08/2010

HW Version : C Card State : Initialization Completed


SW Version : V1.05.01 11/18/2010

[DISPLAY] [SETUP]
C -> Config Display S -> Config Setup
B -> SNCP/UPSR Status M -> Unit Alarm Setup
Q -> Currently-Active Alarm Summary G -> Loopback & Diagnostics Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance L -> File Transfer
K -> Diagnostics Display D -> SNCP/UPSR APS Setup

[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu

>>SPACE bar to refresh or enter a command ===>

13
Chapter 4 E/T1 Setup Procedure

4.4 Configuration Setup


The Unit Menu path for Config Setup is as follows:

S > Config Setup

Then press one of the following:


A > Channel Line Interface Setup
B > Trace Message & EPSL Setup
C > Customer information Setup
D > RDI Mode Setup
E > TPSG Protection Mode Setup
F > TPSG Protection Switch Setup
G > LIU HighZ Setup

Screen by screen setup examples are shown below.

Setup Screen Access


To set up the Config, press S from the Unit Menu.
HW Version : C Card State : Initialization Completed
SW Version : V1.05.01 11/18/2010

[DISPLAY] [SETUP]
C -> Config Display S -> Config Setup
B -> SNCP/UPSR Status M -> Unit Alarm Setup
Q -> Currently-Active Alarm Summary G -> Loopback & Diagnostics Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance L -> File Transfer
K -> Diagnostics Display D -> SNCP/UPSR APS Setup

[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu

>>SPACE bar to refresh or enter a command ===>

The Unit Configuration Setup menu will appear. Press A, B, C, D, E, F, or G.


Unit 4 E1 === Unit Configuration Setup === 10:51:37 11/07/2008

A -> Channel Line Interface Setup


B -> Trace Message & EPSL Setup
C -> Customer information Setup
D -> RDI Mode Setup
E -> TPSG Protection Mode Setup
F -> TPSG Protection Switch Setup
G -> LIU HighZ Setup

<< Press ESC key to return to Main Menu or enter a command >>

14
Chapter 4 E/T1 Setup Procedure

4.4.1 Channel Line Interface Setup Procedure


The Unit Menu path for Channel Line Interface Setup Procedure is as follows:

S > Config Setup


A > Channel Line Interface Setup

The Channel Line Interface Setup screen will appear. Use the arrow keys to move the cursor to each field.
Use the Tab key to scroll in your settings. Press the Enter key.

E1 Card Model Setting Options


Coding HDB3, AMI
Impedance Balanced, Unbalanced

T1 Card Model Setting Options


Coding B8ZS, AMI
Equalizer 0~110 ft., 110~220ft.,
220~330 ft., 330~440 ft.,
440~550 ft., 550~660 ft.
Table 4- 1 Channel Line Interface setting Options

Unit 7 E1 == = L ine Int erf ace Set up === 1 2:33 :47


10/1 5/2 007
ARRO W K EYS : CU RSO R M OVE, TA B/` : RO LL UP/ DOWN OP TIO NS

Chan nel ra nge: 1~ 32

E1 # Co ding I mpe danc e E1# C odi ng Imp eda nce


1 HD B3 B ala nced 17 H DB3 Bal anc ed
2 HD B3 B ala nced 18 H DB3 Bal anc ed
3 HD B3 B ala nced 19 H DB3 Bal anc ed
4 HD B3 B ala nced 20 H DB3 Bal anc ed
5 HD B3 B ala nced 21 H DB3 Bal anc ed
6 HD B3 B ala nced 22 H DB3 Bal anc ed
7 HD B3 B ala nced 23 H DB3 Bal anc ed
8 HD B3 B ala nced 24 H DB3 Bal anc ed
9 HD B3 B ala nced 25 H DB3 Bal anc ed
10 HD B3 B ala nced 26 H DB3 Bal anc ed
11 HD B3 B ala nced 27 H DB3 Bal anc ed
12 HD B3 B ala nced 28 H DB3 Bal anc ed
13 HD B3 B ala nced 29 H DB3 Bal anc ed
14 HD B3 B ala nced 30 H DB3 Bal anc ed
15 HD B3 B ala nced 31 H DB3 Bal anc ed
16 HD B3 B ala nced 32 H DB3 Bal anc ed

<< P res s E SC k ey to retu rn to prev iou s m enu >>


Note: If the card is E1(75 ohm), the Impedance field is fixed as unbalanced.

A prompt will ask if you want to change the configuration. Press Y for Yes.
>> Change configuration (Y/N)? (Note: to save, please use V-command)

In order to save this configuration you must return to the e-DXC Controller Menu and press V. Full
instructions can be found in the e-DXC User’s Manual.

15
Chapter 4 E/T1 Setup Procedure

4.4.2 Trace Message & EPSL Setup Procedure


The Unit Menu path for Trace Message & EPSL Setup Procedure is as follows:

S > Config Setup


B > Trace Message & EPSL Setup

The Trace Message & EPSL Setup screen will appear. Use the arrow keys to move the cursor to each
field. Key in your setting. Press the Enter key.

Table 4- 2 Trace Message Setup and EPSL Setting Options #1


Card Model Field Setting Options
E1 Channel # Range is 1~16/1~32/1~63*
(16/32/63 Port)
T1
Note: * It depends on how many ports this card has.
Unit 7 E1 === Trace Message Setup & EPSL === 13:41:26 10/16/2007
ARROW KEYS: CURSOR MOVE, Please Input: 1~32, BACKSPACE to edit

E1 Channel# : 01

<< Press ESC key to return to previous menu >>

An expanded menu will appear. Use the arrow keys to move the cursor to each field. Use the Tab key to
scroll in your settings. Press the Enter key.
Table 4- 3 Trace Message Setup and EPSL Setting Options #2
Card Model Field Setting Options Default
E1 J2_LEN BYTE(Space Padding) NULL
T1 64-BYTE(Space Padding)
16-BYTE(NULL Padding)
64-BYTE(NULL Padding)
Expected J2_MSG Set up by user
TX_J2_MSG Set up by user
RX_J2_MSG Setup by user
LP_EPSL 0~7 2

Unit 4 E1 == = T rac e Me ssa ge Setu p & EP SL = == 1 1:1 2:59


11/0 7/2 008
ARRO W K EYS : CU RSO R M OVE, Pl eas e In put : 0 ~7, BAC KSP ACE to edi t

E1 Channel# :01
J2_LEN :16-BYTE(Space Padding)
Expected_J2_MSG :
TX_J2_MSG :
RX_J2_MSG :

LP _EPS L : 2 ( Asy nch rono us )

Cop y t he same co nfi g. f rom Ch an#0 1 t o C han# 01

>> C han ge conf igu rat ion (Y/ N)? (No te: to save ,pl eas e us e V -co mman d)
A prompt will ask if you want to change the configuration. Press Y for Yes.
>> Change configuration (Y/N)? (Note:to save,please use V-command)
In order to save this configuration you must return to the e-DXC Controller Menu and press V. Full
instructions can be found in the e-DXC User’s Manual.

16
Chapter 4 E/T1 Setup Procedure

4.4.3 Customer Information Setup Procedure


The Unit Menu path for Customer Information Setup Procedure is as follows:

S > Config Setup


C > Customer information Setup

The Customer Information Setup screen will appear. Use the arrow keys to move the cursor to each
field. Key in your customer information. Press the Enter key.
Unit 7 E1 == = C ust omer In for mati on Set up = == 1 3:11 :28
10/1 5/2 007
ARRO W K EYS : CU RSO R M OVE, BA CKS PACE to ed it, ESC to abo rt

Chan nel ra nge: 1~ 32

E1 # Cu stom er Inf orma tio n E1# C ust ome r In for mat ion
1 _ ____ ___ ___ ____ ___ _ 17
2 18
3 19
4 20
5 21
6 22
7 23
8 24
9 25
10 26
11 27
12 28
13 29
14 30
15 31
16 32

<< P res s E SC k ey to retu rn to prev iou s m enu >>

A prompt will ask if you want to change the configuration. Press Y for Yes.
>> Change configuration (Y/N)? (Note:to save,please use V-command)

In order to save this configuration you must return to the e-DXC Controller Menu and press V. Full
instructions can be found in the e-DXC User’s Manual.

17
Chapter 4 E/T1 Setup Procedure

4.4.4 RDI Mode Setup Procedure


The Unit Menu path for RDI Mode Setup Procedure is as follows:

S > Config Setup


D > RDI Mode Setup

The RDI Mode Setup screen will appear. Use the arrow keys to move the cursor to each field. Use the Tab
key to scroll in your settings. Press the Enter key.

Table 4- 4 RDI Mode Setup Setting Options


Card Model Field Setting Options Note
E1 Mode RDI,
T1 E-RDI

Unit 7 E1 == = RD I M ode Set up === 1 3:13 :25


10/1 5/2 007
ARRO W K EYS : CU RSO R M OVE, TA B/` : RO LL UP/ DOWN OP TIO NS

Chan nel ra nge : 1 -32

E1 # Mo de E1# M ode
1 RD I 17 R DI
2 RD I 18 R DI
3 RD I 19 R DI
4 RD I 20 R DI
5 RD I 21 R DI
6 RD I 22 R DI
7 RD I 23 R DI
8 RD I 24 R DI
9 RD I 25 R DI
10 RD I 26 R DI
11 RD I 27 R DI
12 RD I 28 R DI
13 RD I 29 R DI
14 RD I 30 R DI
15 RD I 31 R DI
16 RD I 32 R DI

<< P res s E SC k ey to retu rn to prev iou s m enu >>

A prompt will ask if you want to change the configuration. Press Y for Yes.
>> Change configuration (Y/N)? (Note:to save,please use V-command)

In order to save this configuration you must return to the e-DXC Controller Menu and press V. Full
instructions can be found in the e-DXC User Manual.

18
Chapter 4 E/T1 Setup Procedure

4.4.5 TPSG Protection Mode Setup Procedure


The Unit Menu path for TPSG protection Mode Setup Procedure is as follows:

S > Config Setup


E > TPSG Protection Mode Setup

The TPSG Protection Mode Setup screen will appear. Use the arrow keys to move the cursor to each
field. Use the Tab key to scroll in your settings. Press the Enter key.

Table 4- 5 TPSG Protection Mode Setting Options

Card Model Field Setting Options Note


E1 TPSG Protection Type OFF,
T1 Card Base(1:1),
Port Base(1:1),
Line (1+1)
TPSG Protection Mode Revertible or Non-revertible Only for Port Base
(1:1)/Line (1+1)

Unit 7 E1 == = T PSG Pro tec tio n Mo de Set up = == 13: 14:3 2


10/1 5/2 007
ARRO W K EYS : CU RSO R M OVE, TA B/` : RO LL UP/ DOWN OP TIO NS

TP SG Pro tect ion Ty pe : OFF

<< P res s E SC k ey to retu rn to prev iou s m enu >>

A prompt will ask if you want to change the configuration. Press Y for Yes.
>> Change configuration (Y/N)? (Note:to save,please use V-command)

In order to save this configuration you must return to the e-DXC Controller Menu and press V. Full
instructions can be found in the e-DXC User Manual.

19
Chapter 4 E/T1 Setup Procedure

4.4.6 TPSG Protection Switch Setup Procedure

The Unit Menu path for TPSG Protection Switch Setup Procedure is as follows:

S > Config Setup


F > TPSG Protection Switch Setup

The TPSG Protection Switch Setup screen will appear. Use the arrow keys to move the cursor to each field.
Use the Tab key to scroll in your settings. Press the Enter key.

Table 4- 6 TPSG Protection Switch Setting Options

Card Model Field Setting Options Note


E1 Side Left, Right
T1

Unit 7 E1 === TP SG Prot ect ion Swi tch Se tup === 1 3:16 :11
10/1 5/2 007
ARRO W K EYS : CU RSO R M OVE, TA B/` : RO LL UP/ DOWN OP TIO NS

E1 # Si de E1# Sid e
1 Le ft 17 Lef t
2 Le ft 18 Lef t
3 Le ft 19 Lef t
4 Le ft 20 Lef t
5 Le ft 21 Lef t
6 Le ft 22 Lef t
7 Le ft 23 Lef t
8 Le ft 24 Lef t
9 Le ft 25 Lef t
10 Le ft 26 Lef t
11 Le ft 27 Lef t
12 Le ft 28 Lef t
13 Le ft 29 Lef t
14 Le ft 30 Lef t
15 Le ft 31 Lef t
16 Le ft 32 Lef t

<< P res s E SC k ey to retu rn to prev iou s m enu >>

A prompt will ask if you want to change the configuration. Press Y for Yes.
>> Change configuration (Y/N)? (Note: to save, please use V-command)

20
Chapter 4 E/T1 Setup Procedure

4.4.7 LIU HighZ Setup

Unit 4 E1 === LIU HighZ Setup === 14:12:30 11/07/2008


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

LIU#1 TX HighZ : Disable


LIU#2 TX HighZ : Disable

<< Press ESC key to return to previous menu >>

Press Enter

SUCCESS
>> Change configuration (Y/N)? (Note:to save,please use V-command)Y

21
Chapter 4 E/T1 Setup Procedure

4.5 Alarm Setup


The Unit Menu path for Alarm Setup is as follows:

M > Alarm Setup

Then press one of the following:


A > Alarm mask and relay Setup
B > Alarm Severity Setup
C > Insert AIS Alarm Setup

Screen by screen setup examples are shown below.

Setup Screen Access


To set up the Alarms, press M from the Unit Menu.
The Unit Alarm Sertup menu will appear. Press A, B, or C.
Unit 4 E1 === Unit Alarm Setup === 14:30:40 11/07/2008

A -> Alarm mask and relay Setup


B -> Alarm Severity Setup
C -> Insert AIS Alarm Setup

<< Press ESC key to return to Main Menu or enter a command >>

22
Chapter 4 E/T1 Setup Procedure

4.5.1 Alarm Mask and Relay Setup Procedure


The Unit Menu path for Alarm Mask and Relay Setup is as follows:

M > Alarm Setup


A > Alarm Mask and Relay Setup

The Unit Alarm Mask and Relay Setup screen will appear. Use the arrow keys to move the cursor to each
field. Key in your setting. Press the Enter key.

Table 4- 7 Unit Alarm Mask and Relay Setting Options #1


Card Model Field Setting Options
E1 Channel # 1~63
(16/32/63 Ports)
T1
Note: * It depends on how many ports this card has.

Unit 4 E1 = == U nit Al arm Mas k a nd R ela y S etup == = 14: 31:2 4


11/0 7/2 008
ARRO W K EYS : CU RSO R M OVE, TA B/` : RO LL UP/ DOWN OP TIO NS

E1 Cha nne l# : 01

An expanded screen will appear. Use the arrow keys to move the cursor to each field. Use the Tab key to
scroll in your settings. Press the Enter key.
Table 4- 8 Unit Alarm Mask and Relay Setting Options #2
Card Model Field Setting Options
E1 Alarm ENABLED,
T1 Relay DISABLED

Unit 4 E1 = == U nit Al arm Mas k a nd R ela y S etup == = 14: 31:2 4


11/0 7/2 008
ARRO W K EYS : CU RSO R M OVE, TA B/` : RO LL UP/ DOWN OP TIO NS

E1 Cha nne l# : 01

Typ e Al arm Re lay


TU- LOP DI SAB LED DI SAB LED
TU- AIS DI SAB LED DI SAB LED
LP- UNE Q DI SAB LED DI SAB LED
LP- PLM DI SAB LED DI SAB LED
LP- TIM DI SAB LED DI SAB LED
LP- RDI -P DI SAB LED DI SAB LED
LP- RDI -S DI SAB LED DI SAB LED
LP- RDI -C DI SAB LED DI SAB LED
LP- V5- REI DI SAB LED DI SAB LED
LP- V5- BIP DI SAB LED DI SAB LED
LOS EN ABL ED DI SAB LED
AIS EN ABL ED DI SAB LED
UAS EN ABL ED DI SAB LED
RAI EN ABL ED DI SAB LED

Cop y t he same co nfi g. f rom Ch an#0 1 t o C han# 01

<< P res s E SC k ey to retu rn to prev iou s m enu >>


A prompt will ask if you want to change the configuration. Press Y for Yes.
>> Change configuration (Y/N)? (Note: to save, please use V-command)
4.5.2 Alarm Severity Setup Procedure
The Unit Menu path for Alarm Severity Setup is as follows:

M > Alarm Setup

23
Chapter 4 E/T1 Setup Procedure

B > Alarm Severity Setup

The Unit Alarm Severity Se tup screen will appear. Use the arrow keys to move the cursor to each field. Use
the Tab key to scroll in your settings. Press the Enter key.

Table 4- 9 Unit Alarm Severity Setting Options


Card Model Field Setting Options
E1 Severity MAJR,
T1 MINR,
INFO,
CRIT

Unit 4 E1 == = U nit Ala rm Sev erit y S etu p == = 1 6:35 :07


11/0 7/2 008
ARRO W K EYS : CU RSO R M OVE, TA B/` : RO LL UP/ DOWN OP TIO NS

Typ e Se ver ity


TU- LOP MA JR
TU- AIS MA JR
LP- UNE Q MA JR
LP- PLM MA JR
LP- TIM MA JR
LP- RDI -P MA JR
LP- RDI -S MA JR
LP- RDI -C MA JR
LP- V5- REI MA JR
LP- V5- BIP MA JR
LOS MA JR
AIS MA JR
UAS MA JR
RAI MA JR
(CRI T:C RIT ICAL , M AJR :MAJ OR, MI NR:M INO R, INFO :IN FOR M)

<< P res s E SC k ey to retu rn to prev iou s m enu >>

A prompt will ask if you want to change the configuration. Press Y for Yes.
>> Change configuration (Y/N)? (Note:to save,please use V-command)

In order to save this configuration you must return to the e-DXC Controller Menu and press V. Full
instructions can be found in the e-DXC User’s Manual.

24
Chapter 4 E/T1 Setup Procedure

4.5.3 Insert AIS Alarm Setup

The Unit Menu path for Insert AIS Alarm Setup is as follows:

M > Alarm Setup


C > Insert AIS Alarm Setup

The Insert AIS Alarm Setup screen will appear. Use the arrow keys to move the cursor to each field. Use
the Tab key to scroll in your settings. Press the Enter key.

Table 4- 10 Insert AIS Alarm Setting Options


Card Model Field Setting Options
E1 Alarm ENABLED,
T1 DISABLED

Unit 4 E1 === In sert AI S A larm Se tup === 1 6:36 :22


11/0 7/2 008
ARRO W K EYS : CU RSO R M OVE, TA B/` : RO LL UP/ DOWN OP TIO NS

T ype Al arm
- --- --- ---- --- -- --- --- --
L ine -LO S t o A IS : EN ABL ED
T U-L OM t o A IS : EN ABL ED
T U-L OP t o A IS : EN ABL ED
L P-U NEQ t o A IS : EN ABL ED
L P-P LM t o A IS : EN ABL ED

<< P res s E SC k ey to retu rn to prev iou s m enu >>

A prompt will ask if you want to change the configuration. Press Y for Yes.
>> Change configuration (Y/N)? (Note:to save,please use V-command)

25
Chapter 4 E/T1 Setup Procedure

4.6 Loopback and Diagnostics Setup


The Unit Menu path for Loopback and Diagnostics Setup is as follows:

G > Loopback and Diagnostics Setup

Then press one of the following:


A > Channel Loopback Setup
B > Unit Diagnostics Setup

Screen by screen setup examples are shown below.

Setup Screen Access


To set up Loopbacks and Diagnostics, press G from the Unit Menu.

HW Version : C Card State : Initialization Completed


SW Version : V1.05.01 11/18/2010

[DISPLAY] [SETUP]
C -> Config Display S -> Config Setup
B -> SNCP/UPSR Status M -> Unit Alarm Setup
Q -> Currently-Active Alarm Summary G -> Loopback & Diagnostics Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance L -> File Transfer
K -> Diagnostics Display D -> SNCP/UPSR APS Setup

[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu

>>SPACE bar to refresh or enter a command ===>

The Loopback and Diagnostics Setup screen will appear. Press A or B.


Unit 4 E1 === Loopback & diagnostics Setup === 15:34:15 10/15/2007

A -> Channel Loopback Setup


B -> Unit Diagnostics Setup

<< Press ESC key to return to Main Menu or enter a command >>

26
Chapter 4 E/T1 Setup Procedure

4.6.1 Channel Loopback Setup Procedure

The Unit Menu path for Channel Loopback Setup is as follows:

G > Loopback and Diagnostics Setup


A > Channel Loopback Setup
The Channel Loopback Setup screen will appear. Use the arrow keys to move the cursor to each field.
Use the Tab key to scroll in your settings. Press the Enter key.

Table 4- 11 Channel Loopback Setting Options


Card Model Field Setting Options Note
E1 Mode OFF, LOC, LOC: Local Loopback
T1 LLB LLB: Line Loopback

Uni t 4 E1 == = C hann el Loo pbac k S etu p == = 16:3 9:5 9


11/0 7/2 008
ARRO W K EYS : CU RSO R M OVE, TA B/` : RO LL UP/ DOWN OP TIO NS

Chan nel ra nge : 1 ~32


E1 # Mo de E1# M ode
1 OF F 17 O FF
2 OF F 18 O FF
3 OF F 19 O FF
4 OF F 20 O FF
5 OF F 21 O FF
6 OF F 22 O FF
7 OF F 23 O FF
8 OF F 24 O FF
9 OF F 25 O FF
10 OF F 26 O FF
11 OF F 27 O FF
12 OF F 28 O FF
13 OF F 29 O FF
14 OF F 30 O FF
15 OF F 31 O FF
16 OF F 32 O FF

<< P res s E SC k ey to retu rn to prev iou s m enu >>

A prompt will ask if you want to change the configuration. Press Y for Yes.
>> Change configuration (Y/N)? (Note: to save, please use V-command)

27
Chapter 4 E/T1 Setup Procedure

4.6.2 Unit Diagnostics Setup Procedure


The Unit Menu path for Unit Diagnostics Setup is as follows:

G > Loopback and Diagnostics Setup


B > Unit Diagnostics Setup

The Unit Diagnostics Setup screen will appear. Use the arrow keys to move the cursor. Key in your
Channel # setting. Press the Enter key.

Table 4- 12 Optical Line Alarm Mask/Relay Setting Options 2


Card Model Field Setting Options
E1 Channel # Range is 1~16/1~32/1~63*
(16/32/63 Ports)
T1
Note: * It depends on how many ports this card has.

Unit 4 E1 == = C han nel Dia gno stic s S etu p == = 1 6:06 :02


10/1 5/2 007
ARRO W K EYS : CU RSO R M OVE, Pl eas e In put : 1 ~32, BA CKS PACE to ed it

Sen d T est Pat ter n t o == >

E1 Cha nne l# : 01

Dir ect ion :

Tes t P att ern :

<< P res s E SC k ey to retu rn to prev iou s m enu >>

Use the arrow keys to move the cursor to the various fields. Use the Tab key to scroll in your setting. Press
the Enter key.

Table 4- 13 Channel Diagnostics Setting Options #2


Card Model Field Setting Options
E1 Channel # Range is
T1 1~16/1~32/1~63*
(16/32/63 Ports) Direction System Side, Line Side
Test Pattern OFF, 2^11-1,
2^15-1, 2^20-1
Note: * It depends on how many ports this card has.

Unit 4 E1 === Channel Diagnostics Setup === 16:40:27 11/07/2008


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Send Test Pattern to ==>

E1 Channel# : 01

Direction :System side

Test Pattern :OFF

<< Press ESC key to return to previous menu >>

28
Chapter 4 E/T1 Setup Procedure

4.7 Performance Setup/Clear


The Unit Menu path for Performance Setup/Clear is as follows:

R > Performance Setup/Clear

Then press one of the following:

A > Unit Clear Performance Data


B > Unit Performance Threshold Setup
C > Line Monitor Framer Setup

Screen by screen setup examples are shown below.

Setup Screen Access


To set up Performance Setup/Clear, press R from the Unit Menu.

HW Version : C Card State : Initialization Completed


SW Version : V1.05.01 11/18/2010

[DISPLAY] [SETUP]
C -> Config Display S -> Config Setup
B -> SNCP/UPSR Status M -> Unit Alarm Setup
Q -> Currently-Active Alarm Summary G -> Loopback & Diagnostics Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance L -> File Transfer
K -> Diagnostics Display D -> SNCP/UPSR APS Setup

[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu

>>SPACE bar to refresh or enter a command ===>

The Performance Setup/Clear screen will appear. Press A, B or C.


Unit 4 E1 === Performance Setup/Clear === 16:30:36 10/15/2007

A -> Unit Clear Performance Data


B -> Unit Performance Threshold Setup
C -> Line Monitor Framer Setup

<< Press ESC key to return to Main Menu or enter a command >>

29
Chapter 4 E/T1 Setup Procedure

4.7.1 Unit Clear Performance Data Procedure

The Unit Menu path for Unit Clear Performance Data is as follows:

R > Performance Setup/Clear


A > Unit Clear Performance Data

A prompt will ask if you want to clear the performance data. Press Y for yes.
>> Clear performance data - are you sure [Y/N] ?

4.7.2 Unit Performance Threshold Setup Procedure

The Unit Menu path for Unit Performance Threshold Setup is as follows:

R > Performance Setup/Clear


B > Unit Performance Threshold Setup

The Unit Performance Threshold Setup screen will appear. Use the arrow keys to move the cursor to each
field. Use the Tab key to scroll in your settings. Press the Enter key.

Table 4- 14 Unit Performance Threshold Setting Options


Card Model Field Setting Options
E1 En/Dis EN,
T1 DIS
Severity MAJR,
MINR,
INFO,
CRIT
Threshold 1~99999

Uni t 4 E1 === Uni t P erfo rma nce Thr esh old Set up === 16:4 7:1 8
11/0 7/2 008
ARRO W K EYS : CU RSO R M OVE, TA B/` : RO LL UP/ DOWN OP TIO NS

Moni tor Po int En /Di s s eve rit y T hre sho ld


BIP- V5 EN I NFO 0 060 0
REI- V5 EN I NFO 0 060 0
BPV EN I NFO 0 060 0

<< P res s E SC k ey to retu rn to prev iou s m enu >>

A prompt will ask if you want to change the configuration. Press Y for Yes.
>> Change configuration (Y/N)? (Note: to save, please use V-command)

30
Chapter 4 E/T1 Setup Procedure

4.7.3 Line Monitor Framer Setup Procedure


The Unit Menu path for Line Monitor Framer Setup is as follows:

R > Performance Setup/Clear


C > Line Monitor Framer Setup

The Line Monitor Framer Setup screen will appear. Use the arrow keys to move the cursor. Key in
your Channel # setting. Press the Enter key.

Table 4- 15 Line Monitor Framer Setting Options #1


Card Model Field Setting Options
E1 Channel # Range is 1~16/1~32/1~63*
(16/32/63 Ports)
T1
Note: * It depends on how many ports this card has.
Unit 4 E1 == = L ine Mon ito r F rame r S etu p == = 1 6:45 :09
10/1 5/2 007
ARRO W K EYS : CU RSO R M OVE, Pl eas e In put : 1 ~32, BA CKS PACE to ed it

E1 Ch anne l# : 0 1

<< P res s E SC k ey to retu rn to prev iou s m enu >>

Use the arrow keys to move the cursor to the various fields. Use the Tab key to scroll in your setting. Press
the Enter key.

Table 4- 16 Line Monitor Framer Setting Options #2


Card Model Field Setting Options
E1 Frame OFF,
CRC ON
CAS
T1 Frame OFF, DS4, ESF

Unit 4 E1 === Line Monitor Framer Setup === 16:45:09 10/15/2007


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

E1 Channel# : 01
Frame : OFF
CRC : OFF
CAS : OFF

Copy the same config. from Chan#01 to Chan#01

<< Press ESC key to return to previous menu >>

A prompt will ask if you want to change the configuration. Press Y for Yes.
>> Change configuration (Y/N)? (Note: to save, please use V-command)

31
Chapter 4 E/T1 Setup Procedure

4.8 File Transfer


The Unit Menu path for File Transfer is as follows:
L > File Transfer

Then press one of the following:


A > Unit Download Firmware
B > Copy Firmware to Standby Unit

Screen by screen setup examples are shown below.

Setup Screen Access


To set up a File Transfer, press L from the Unit Menu.
HW Version : C Card State : Initialization Completed
SW Version : V1.05.01 11/18/2010

[DISPLAY] [SETUP]
C -> Config Display S -> Config Setup
B -> SNCP/UPSR Status M -> Unit Alarm Setup
Q -> Currently-Active Alarm Summary G -> Loopback & Diagnostics Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance L -> File Transfer
K -> Diagnostics Display D -> SNCP/UPSR APS Setup

[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu

>>SPACE bar to refresh or enter a command ===>

The FileTransfer screen will appear. Press A or B.


Unit 4 E1 ===File Transfer=== 16:57:21 11/07/2008

A -> Unit Download Firmware

<< Press ESC key to return to Main Menu or enter a command >>

32
Chapter 4 E/T1 Setup Procedure

4.8.1 Unit Download Firmware Procedure

The Unit Menu path for Unit Download Firmware is as follows:


L > File Transfer
A > Unit Download Firmware

The Unit Download Firmware Setup screen will appear. Use the arrow keys to move
the cursor. Key in the TFTP Server IP address and the firmware file name. Press the Enter
key.
Unit 5 E1 === Unit Download Firmware === 14:46:05 11/03/2007
ARROW KEYS: CURSOR MOVE, BACKSPACE to edit, ESC to abort

Firmware 1 Version : V1.01.01 10/19/2007


Firmware 2 Version : V1.01.01 10/19/2007
Current Firmware Bank: 1
Next Boot Firmware : 1
TFTP Server IP : 000.000.000.000
Firmware File Name : ____________________________________________

<< Press ESC key to abort, ENTER key to Upload/Download Firmware >>

A prompt will ask if you really want to download. Press Y for yes.
Really want to Download ?

A message will be displayed as the download is in progress and a new message will appear
once the download is complete.
Unit 5 E1 === Unit Download Firmware === 14:48:39 11/03/2007
ARROW KEYS: CURSOR MOVE, BACKSPACE to edit, ESC to abort

Firmware 1 Version : V1.01.01 10/19/2007


Firmware 2 Version : V1.01.01 10/19/2007
Current Firmware Bank: 1
Next Boot Firmware : 1
TFTP Server IP : 010.003.011.001
Firmware File Name : O94RE1-C.RUN

14:48:45 11/03/07 Downloading firmware ........619148 bytes received.


14:48:55 11/03/07 Send firmware file to trib-5 ........Download Complete.

<< Press ESC key to abort, ENTER key to Upload/Download Firmware >>

33
Chapter 4 E/T1 Setup Procedure

Scenario 1: Force Switch the Firmware Bank

This procedure applies to all types of E1/T1 cards.

1. If you want to Force Switch the Firmware Bank for E1/T1 cards, you need to use the
spare jumper enclosed with shipping package.
2. You need to pull the E1/T1 card out of Chassis and place the spare jumper in U21
(Jumper ON) location shown in below.

Front Side Rear Side

U21

U21

ON OFF

3. Put the card back to Chassis and the card will switch to another Firmware Bank
automatically. For confirmation, you can go to Unit Download Firmware screen to check
the Current Firmware Version Number.
4. You need to pull the E1/T1 card out of Chassis again and remove the jumper out of U21.
5. The process complete.

Note: If you leave the Jumper On in U21, the bank will do the bank switch every time when
the card reset.

34
Chapter 4 E/T1 Setup Procedure

4.9 SNCP/UPSR APS Setup


Note: You must set up a cross-connect map before the SNCP/UPSR APS Setup will function.
The Cross-connect mapping instructions can be found in the e-DXC User’s Manual.

The Unit Menu path for SNCP/UPSR APS Setup is as follows:


D > SNCP APS Setup

The SNCP/UPSR APS Setup screen will appear. Press A or B.


Unit 7 E1 === SNCP/UPSR APS Setup === 01:02:37 09/04/2009

A -> SNCP/UPSR APS Command


B -> SNCP/UPSR Revertive Setup

<< Press ESC key to return to Main Menu or enter a command >>

4.9.1 SNCP/UPSR APS Command


The Unit Menu path for SNCP/UPSR APS Command is as follows:
D > SNCP/UPSR APS Setup
A > SNCP/UPSR APS Command

The SNCP/UPSR APS Command screen will appear. Key in the port number. Press the
Enter key.

Unit 1 E1 === SNCP/UPSR APS Command === 16:59:01 08/03/2011


ARROW KEYS: CURSOR MOVE, Please Input: 1~16, BACKSPACE to edit
Select path ==>

Port : 01

<< Press ESC key to return to previous menu >>

Another screen appears. Use the Tab key to scroll in your setting. Press the Enter key.
Unit 1 E1 === SNCP/UPSR APS Command === 10:14:21 08/04/2011
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Command : Clear

Note :
FS = Force Switch
MS = Manual Switch
PRI = Primary
SEC = Secondary

>>Are you sure (Y/N)?

SNCP/UPSR APS Command Setting Options


Card Model Field Setting Options
E1/T1 Port 1~16/1~32/1~63*
(16/32/63 Command CLEAR,
ports) FS to PRI., FS to SEC., MS to
PRI., MS to SEC., Lockout
Note: * It depends on how many ports this card has.

A prompt will appear on the screen to tell you that the command has been accepted.
APS Cmd Accepted!

35
Chapter 4 E/T1 Setup Procedure

4.9.2 SNCP/UPSR Revertive Setup


The Unit Menu path for SNCP/UPSR Revertive setup is as follows
D > SNCP/UPSR APS Setup
B > SNCP/UPSR Revertive Setup

The SNCP/UPSR Revertive Setup screen will appear. Use the Tab key to scroll in your
settings and then press Enter.

Unit 1 E1 === SNCP/UPSR Revertive Setup === 18:00:57 09/02/2011


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Port : 01

Revertive: Non-Revertive

<< Press ESC key to return to previous menu >>

SNCP/UPSR APS Revertive Setting Options


Card Model Field Setting Options
E1/T1 Port 1~16/1~32/1~63*
(16/32/63 ports) Revertive Revertive, Non-revertive
Note: * It depends on how many ports this card has.