Professional Documents
Culture Documents
E1/T1 Interface Plug-In Card FOR Alstom e-DXC Enhanced Digital Cross-Connect User'S Manual
E1/T1 Interface Plug-In Card FOR Alstom e-DXC Enhanced Digital Cross-Connect User'S Manual
LIST OF TABLES
Table 3- 1 LED Indication for E1/T1 Card ................................................................................................. 7
GB At the end of the product's useful life, please dispose of it at appropriate collection
points provided in your country
F Une fois le produit en fin devie, veuillez le déposer dans un point de recyclage
approprié.
ES Para preservar el medio ambiente, al final dela vida útil de su producto, depositelo
en los laguares destinado aello de acuerdo con la legislación vigente.
P No final de vida útil do producto, por favor coloque no ponto de recolha apropriado.
I I Onde tutelare l'ambiente, non buttate l'apparecchio trai i normali rifiuti al termine
della sua vita utile, ma portatelo presso i punti DI RACCOLTA specifici per questi
rifiuti previsti dalla normativa vigente.
NL Wij raden u aan het apparant aan het einde van zijn nuttige levensduur, niet bij hey
gewone huisafval te deponeren, maar op de dearvoor bestemde adressen.
PL Gdy produkt nie nadaje sie juz do dalszego uzytku, nalezy zostawic go w jednym ze
specjalnych punktów zajmujacych sie zbiórka zuzytych producktów w wybranych
miejscach na terenie kraju.
SLO Ko se izdelku izteče življenska doba, ga odnesite na ustrezno zbirno mesto oziroma
ga odvrzite v skladu z veljavnimi predpisi.
PRC 當產品使用壽命結束,請在你的國家所提供的適當地點做好回收處理
Chapter 1 Product Description
1 Product Description
The E1/T1 Interface Card is a software selectable plug-in card. Depending upon manufacturing options
there are Nx E1/T1 ports available, where N=16/32/63TE or 16/32/63E75. The card is hot-pluggable and can
be installed in or removed from an e-DXC chassis when the e-DXC device is powered up.
1
Chapter 1 Product Description
Tributary Protection
Switching Group #1
Working Standby
2
Chapter 1 Product Description
T1 Interface
Line Rate 1.544 Mbps ± 32 ppm Jitter ITU G.824
Line Code AMI/B8ZS Framing Unframed with a framing monitor on
receiving side
Input Signal ITU G.703 DSX-1 0dB to –6dB Impedance 100 ohm twisted pair
Output Signal ITU G.703 DSX-1 w/short (0-110, Connector SCSI-II 68-pin
110-220, 220-330, 330-440, 440- One connector for 16 ports
550, 550~660 feet) Two connectors for 32 ports
Four connectors for 63 ports
Output Mask Bellcore GR-499-core
3
Chapter 2 Installation
2 Installation
The E1/T1 interface card will plug into any tributary slot in the e-DXC chassis. E1/T1 interface cards are hot
swappable.
4
Chapter 2 Installation
5
Chapter 2 Installation
6
Chapter 3 Operation
3 Operation
LED Indication for E1/T1 Card
LED Color Indication
ACTIVE Off Off
Flashing Green Working E1/T1 card
Flashing Amber Standby E1/T1 card
Red Card is unregistered
ALM This LED is used to indicate alarm status:TU-LOP, TU-AIS, LP-UNEQ, LP-PLM,
LP-TIM, LP-RDI-P, LP-RDI-S, LP-RDI-C, LP-V5-REI, LP-V5-BIP, LOS, AIS, UAS,
RAI/YEL ... all paired alarms about SDH/SONET.
Red Critical alarm message or Major alarm message occurs
Amber Minor alarm message occurs
Green Informative alarm message or no alarm message occurs
E1 Indicator Off T1
Green E1
Table 3- 1 LED Indication for E1/T1 Card
7
Chapter 4 E/T1 Setup Procedure
Please note that Tributary cards must be registered with the e-DXC device or you will not be able to access
their detailed menu screens. The card registration procedure is detailed in Section 4.2 of this manual.
8
Chapter 4 E/T1 Setup Procedure
You must register your E1/T1 cards with the e-DXC device.
Press N to register the unit (ie. register your card).
e-DXC === Controller Menu === 10:21:29 11/07/2008
[DISPLAY] [SETUP]
C -> System Config Display S -> System Config Setup
D -> SDH/SONET Display H -> SDH/SONET Setup
J -> PDH Display K -> PDH Setup
P -> Map Display G -> Map Setup
Q -> Alarm Queue M -> Alarm Setup
I -> System Information L -> File Transfer
T -> System Log V -> Store/Retrieve Backup Config
N -> Unit Registration
[LOG] [MISC]
F -> Log Off Y -> Alarm Cut Off
O -> Log On Z -> Reset
U -> Choose a Trib Unit X -> Clear Alarm Queue
W -> Return to Default
The following screen will appear. The slot location of any card in the device shows up on the screen.
Choose the command “Card Registration” and press Enter. The model name “E1-75ohm” represents 75ohm
E1 interface, and “E1” represents 120ohm E1 interface. Choose “Card Registration” to start the register
process.
e-DXC === Unit Registration === 10:23:10 02/10/2010
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
9
Chapter 4 E/T1 Setup Procedure
Use the Tab key to scroll in the Tributary slot that your E1/T1 card is plugged into. Press the Enter key.
Command : Card Registration
Unit : Trib-4
Note that the model of card will appear. Move the cursor to the Registered Model field and scroll in either the
E1 or T1 setting. Press the Enter key.
Command : Card Registration
Unit : Trib-4
REG. Model/Mode : E1-PRTD(63Port)
A registration prompt will appear as the registration takes place.
Registration......SUCCESS!
After registration, the E1/T1 card information will show on the screen:
e-DXC === Unit Registration === 10:23:10 02/10/2010
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
If you have other cards to register do it now. Each plug-in interface card must be registered separately.
10
Chapter 4 E/T1 Setup Procedure
Card De-registration:
To de-register a card, please activate the command “Card Un-registration”. The setup procedure is similar to
that of “Card registration”.
Note: If you want to change a registered card from E1 toT1 or vice-versa, you must de-register the card and
re-register it again.
e-DXC === Unit Registration === 10:23:10 02/10/2010
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
11
Chapter 4 E/T1 Setup Procedure
[DISPLAY] [SETUP]
C -> System Config Display S -> System Config Setup
D -> SDH/SONET Config Display H -> SDH/SONET Config Setup
I -> System Information M -> Alarm Setup
Q -> Alarm Queue L -> File Transfer
B -> Currently-Active Alarm Summary V -> Store/Retrieve Backup Config
A -> Current Alarm Status G -> Loopback/Diagnostics Setup
P -> SDH/SONET Performance R -> Performance Setup/Clear
T -> System Log N -> Unit Registration
E -> Diagnostics Display
[LOG] [MISC]
F -> Log Off Y -> Alarm Cut Off
O -> Log On Z -> Reset
U -> Choose a Trib Unit X -> Clear Alarm Queue
W -> Return to Default
A prompt will appear. Use the Tab key to scroll in the card’s Tributary slot number. Press the Enter key.
==>> Press Tab key to select the unit: 4
The unit menu will appear for that card. If the unit you select is a 120ohm E1 card, the model name on the
upper left of the screen shows “E1”.
Unit 1 E1 === Unit Menu === 18:00:09 09/02/2011
[DISPLAY] [SETUP]
C -> Config Display S -> Config Setup
B -> SNCP/UPSR Status M -> Unit Alarm Setup
Q -> Currently-Active Alarm Summary G -> Loopback & Diagnostics Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance L -> File Transfer
K -> Diagnostics Display D -> SNCP/UPSR APS Setup
[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu
12
Chapter 4 E/T1 Setup Procedure
If the unit you select is a 75ohm E1 card, the model name on the upper left of the screen shows “E1-75ohm”.
Unit 1 E1-75ohm === Unit Menu === 18:20:50 02/08/2010
[DISPLAY] [SETUP]
C -> Config Display S -> Config Setup
B -> SNCP/UPSR Status M -> Unit Alarm Setup
Q -> Currently-Active Alarm Summary G -> Loopback & Diagnostics Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance L -> File Transfer
K -> Diagnostics Display D -> SNCP/UPSR APS Setup
[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu
13
Chapter 4 E/T1 Setup Procedure
[DISPLAY] [SETUP]
C -> Config Display S -> Config Setup
B -> SNCP/UPSR Status M -> Unit Alarm Setup
Q -> Currently-Active Alarm Summary G -> Loopback & Diagnostics Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance L -> File Transfer
K -> Diagnostics Display D -> SNCP/UPSR APS Setup
[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu
<< Press ESC key to return to Main Menu or enter a command >>
14
Chapter 4 E/T1 Setup Procedure
The Channel Line Interface Setup screen will appear. Use the arrow keys to move the cursor to each field.
Use the Tab key to scroll in your settings. Press the Enter key.
A prompt will ask if you want to change the configuration. Press Y for Yes.
>> Change configuration (Y/N)? (Note: to save, please use V-command)
In order to save this configuration you must return to the e-DXC Controller Menu and press V. Full
instructions can be found in the e-DXC User’s Manual.
15
Chapter 4 E/T1 Setup Procedure
The Trace Message & EPSL Setup screen will appear. Use the arrow keys to move the cursor to each
field. Key in your setting. Press the Enter key.
E1 Channel# : 01
An expanded menu will appear. Use the arrow keys to move the cursor to each field. Use the Tab key to
scroll in your settings. Press the Enter key.
Table 4- 3 Trace Message Setup and EPSL Setting Options #2
Card Model Field Setting Options Default
E1 J2_LEN BYTE(Space Padding) NULL
T1 64-BYTE(Space Padding)
16-BYTE(NULL Padding)
64-BYTE(NULL Padding)
Expected J2_MSG Set up by user
TX_J2_MSG Set up by user
RX_J2_MSG Setup by user
LP_EPSL 0~7 2
E1 Channel# :01
J2_LEN :16-BYTE(Space Padding)
Expected_J2_MSG :
TX_J2_MSG :
RX_J2_MSG :
>> C han ge conf igu rat ion (Y/ N)? (No te: to save ,pl eas e us e V -co mman d)
A prompt will ask if you want to change the configuration. Press Y for Yes.
>> Change configuration (Y/N)? (Note:to save,please use V-command)
In order to save this configuration you must return to the e-DXC Controller Menu and press V. Full
instructions can be found in the e-DXC User’s Manual.
16
Chapter 4 E/T1 Setup Procedure
The Customer Information Setup screen will appear. Use the arrow keys to move the cursor to each
field. Key in your customer information. Press the Enter key.
Unit 7 E1 == = C ust omer In for mati on Set up = == 1 3:11 :28
10/1 5/2 007
ARRO W K EYS : CU RSO R M OVE, BA CKS PACE to ed it, ESC to abo rt
E1 # Cu stom er Inf orma tio n E1# C ust ome r In for mat ion
1 _ ____ ___ ___ ____ ___ _ 17
2 18
3 19
4 20
5 21
6 22
7 23
8 24
9 25
10 26
11 27
12 28
13 29
14 30
15 31
16 32
A prompt will ask if you want to change the configuration. Press Y for Yes.
>> Change configuration (Y/N)? (Note:to save,please use V-command)
In order to save this configuration you must return to the e-DXC Controller Menu and press V. Full
instructions can be found in the e-DXC User’s Manual.
17
Chapter 4 E/T1 Setup Procedure
The RDI Mode Setup screen will appear. Use the arrow keys to move the cursor to each field. Use the Tab
key to scroll in your settings. Press the Enter key.
E1 # Mo de E1# M ode
1 RD I 17 R DI
2 RD I 18 R DI
3 RD I 19 R DI
4 RD I 20 R DI
5 RD I 21 R DI
6 RD I 22 R DI
7 RD I 23 R DI
8 RD I 24 R DI
9 RD I 25 R DI
10 RD I 26 R DI
11 RD I 27 R DI
12 RD I 28 R DI
13 RD I 29 R DI
14 RD I 30 R DI
15 RD I 31 R DI
16 RD I 32 R DI
A prompt will ask if you want to change the configuration. Press Y for Yes.
>> Change configuration (Y/N)? (Note:to save,please use V-command)
In order to save this configuration you must return to the e-DXC Controller Menu and press V. Full
instructions can be found in the e-DXC User Manual.
18
Chapter 4 E/T1 Setup Procedure
The TPSG Protection Mode Setup screen will appear. Use the arrow keys to move the cursor to each
field. Use the Tab key to scroll in your settings. Press the Enter key.
A prompt will ask if you want to change the configuration. Press Y for Yes.
>> Change configuration (Y/N)? (Note:to save,please use V-command)
In order to save this configuration you must return to the e-DXC Controller Menu and press V. Full
instructions can be found in the e-DXC User Manual.
19
Chapter 4 E/T1 Setup Procedure
The Unit Menu path for TPSG Protection Switch Setup Procedure is as follows:
The TPSG Protection Switch Setup screen will appear. Use the arrow keys to move the cursor to each field.
Use the Tab key to scroll in your settings. Press the Enter key.
Unit 7 E1 === TP SG Prot ect ion Swi tch Se tup === 1 3:16 :11
10/1 5/2 007
ARRO W K EYS : CU RSO R M OVE, TA B/` : RO LL UP/ DOWN OP TIO NS
E1 # Si de E1# Sid e
1 Le ft 17 Lef t
2 Le ft 18 Lef t
3 Le ft 19 Lef t
4 Le ft 20 Lef t
5 Le ft 21 Lef t
6 Le ft 22 Lef t
7 Le ft 23 Lef t
8 Le ft 24 Lef t
9 Le ft 25 Lef t
10 Le ft 26 Lef t
11 Le ft 27 Lef t
12 Le ft 28 Lef t
13 Le ft 29 Lef t
14 Le ft 30 Lef t
15 Le ft 31 Lef t
16 Le ft 32 Lef t
A prompt will ask if you want to change the configuration. Press Y for Yes.
>> Change configuration (Y/N)? (Note: to save, please use V-command)
20
Chapter 4 E/T1 Setup Procedure
Press Enter
SUCCESS
>> Change configuration (Y/N)? (Note:to save,please use V-command)Y
21
Chapter 4 E/T1 Setup Procedure
<< Press ESC key to return to Main Menu or enter a command >>
22
Chapter 4 E/T1 Setup Procedure
The Unit Alarm Mask and Relay Setup screen will appear. Use the arrow keys to move the cursor to each
field. Key in your setting. Press the Enter key.
E1 Cha nne l# : 01
An expanded screen will appear. Use the arrow keys to move the cursor to each field. Use the Tab key to
scroll in your settings. Press the Enter key.
Table 4- 8 Unit Alarm Mask and Relay Setting Options #2
Card Model Field Setting Options
E1 Alarm ENABLED,
T1 Relay DISABLED
E1 Cha nne l# : 01
23
Chapter 4 E/T1 Setup Procedure
The Unit Alarm Severity Se tup screen will appear. Use the arrow keys to move the cursor to each field. Use
the Tab key to scroll in your settings. Press the Enter key.
A prompt will ask if you want to change the configuration. Press Y for Yes.
>> Change configuration (Y/N)? (Note:to save,please use V-command)
In order to save this configuration you must return to the e-DXC Controller Menu and press V. Full
instructions can be found in the e-DXC User’s Manual.
24
Chapter 4 E/T1 Setup Procedure
The Unit Menu path for Insert AIS Alarm Setup is as follows:
The Insert AIS Alarm Setup screen will appear. Use the arrow keys to move the cursor to each field. Use
the Tab key to scroll in your settings. Press the Enter key.
T ype Al arm
- --- --- ---- --- -- --- --- --
L ine -LO S t o A IS : EN ABL ED
T U-L OM t o A IS : EN ABL ED
T U-L OP t o A IS : EN ABL ED
L P-U NEQ t o A IS : EN ABL ED
L P-P LM t o A IS : EN ABL ED
A prompt will ask if you want to change the configuration. Press Y for Yes.
>> Change configuration (Y/N)? (Note:to save,please use V-command)
25
Chapter 4 E/T1 Setup Procedure
[DISPLAY] [SETUP]
C -> Config Display S -> Config Setup
B -> SNCP/UPSR Status M -> Unit Alarm Setup
Q -> Currently-Active Alarm Summary G -> Loopback & Diagnostics Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance L -> File Transfer
K -> Diagnostics Display D -> SNCP/UPSR APS Setup
[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu
<< Press ESC key to return to Main Menu or enter a command >>
26
Chapter 4 E/T1 Setup Procedure
A prompt will ask if you want to change the configuration. Press Y for Yes.
>> Change configuration (Y/N)? (Note: to save, please use V-command)
27
Chapter 4 E/T1 Setup Procedure
The Unit Diagnostics Setup screen will appear. Use the arrow keys to move the cursor. Key in your
Channel # setting. Press the Enter key.
E1 Cha nne l# : 01
Use the arrow keys to move the cursor to the various fields. Use the Tab key to scroll in your setting. Press
the Enter key.
E1 Channel# : 01
28
Chapter 4 E/T1 Setup Procedure
[DISPLAY] [SETUP]
C -> Config Display S -> Config Setup
B -> SNCP/UPSR Status M -> Unit Alarm Setup
Q -> Currently-Active Alarm Summary G -> Loopback & Diagnostics Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance L -> File Transfer
K -> Diagnostics Display D -> SNCP/UPSR APS Setup
[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu
<< Press ESC key to return to Main Menu or enter a command >>
29
Chapter 4 E/T1 Setup Procedure
The Unit Menu path for Unit Clear Performance Data is as follows:
A prompt will ask if you want to clear the performance data. Press Y for yes.
>> Clear performance data - are you sure [Y/N] ?
The Unit Menu path for Unit Performance Threshold Setup is as follows:
The Unit Performance Threshold Setup screen will appear. Use the arrow keys to move the cursor to each
field. Use the Tab key to scroll in your settings. Press the Enter key.
Uni t 4 E1 === Uni t P erfo rma nce Thr esh old Set up === 16:4 7:1 8
11/0 7/2 008
ARRO W K EYS : CU RSO R M OVE, TA B/` : RO LL UP/ DOWN OP TIO NS
A prompt will ask if you want to change the configuration. Press Y for Yes.
>> Change configuration (Y/N)? (Note: to save, please use V-command)
30
Chapter 4 E/T1 Setup Procedure
The Line Monitor Framer Setup screen will appear. Use the arrow keys to move the cursor. Key in
your Channel # setting. Press the Enter key.
E1 Ch anne l# : 0 1
Use the arrow keys to move the cursor to the various fields. Use the Tab key to scroll in your setting. Press
the Enter key.
E1 Channel# : 01
Frame : OFF
CRC : OFF
CAS : OFF
A prompt will ask if you want to change the configuration. Press Y for Yes.
>> Change configuration (Y/N)? (Note: to save, please use V-command)
31
Chapter 4 E/T1 Setup Procedure
[DISPLAY] [SETUP]
C -> Config Display S -> Config Setup
B -> SNCP/UPSR Status M -> Unit Alarm Setup
Q -> Currently-Active Alarm Summary G -> Loopback & Diagnostics Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance L -> File Transfer
K -> Diagnostics Display D -> SNCP/UPSR APS Setup
[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu
<< Press ESC key to return to Main Menu or enter a command >>
32
Chapter 4 E/T1 Setup Procedure
The Unit Download Firmware Setup screen will appear. Use the arrow keys to move
the cursor. Key in the TFTP Server IP address and the firmware file name. Press the Enter
key.
Unit 5 E1 === Unit Download Firmware === 14:46:05 11/03/2007
ARROW KEYS: CURSOR MOVE, BACKSPACE to edit, ESC to abort
<< Press ESC key to abort, ENTER key to Upload/Download Firmware >>
A prompt will ask if you really want to download. Press Y for yes.
Really want to Download ?
A message will be displayed as the download is in progress and a new message will appear
once the download is complete.
Unit 5 E1 === Unit Download Firmware === 14:48:39 11/03/2007
ARROW KEYS: CURSOR MOVE, BACKSPACE to edit, ESC to abort
<< Press ESC key to abort, ENTER key to Upload/Download Firmware >>
33
Chapter 4 E/T1 Setup Procedure
1. If you want to Force Switch the Firmware Bank for E1/T1 cards, you need to use the
spare jumper enclosed with shipping package.
2. You need to pull the E1/T1 card out of Chassis and place the spare jumper in U21
(Jumper ON) location shown in below.
U21
U21
ON OFF
3. Put the card back to Chassis and the card will switch to another Firmware Bank
automatically. For confirmation, you can go to Unit Download Firmware screen to check
the Current Firmware Version Number.
4. You need to pull the E1/T1 card out of Chassis again and remove the jumper out of U21.
5. The process complete.
Note: If you leave the Jumper On in U21, the bank will do the bank switch every time when
the card reset.
34
Chapter 4 E/T1 Setup Procedure
<< Press ESC key to return to Main Menu or enter a command >>
The SNCP/UPSR APS Command screen will appear. Key in the port number. Press the
Enter key.
Port : 01
Another screen appears. Use the Tab key to scroll in your setting. Press the Enter key.
Unit 1 E1 === SNCP/UPSR APS Command === 10:14:21 08/04/2011
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Command : Clear
Note :
FS = Force Switch
MS = Manual Switch
PRI = Primary
SEC = Secondary
A prompt will appear on the screen to tell you that the command has been accepted.
APS Cmd Accepted!
35
Chapter 4 E/T1 Setup Procedure
The SNCP/UPSR Revertive Setup screen will appear. Use the Tab key to scroll in your
settings and then press Enter.
Port : 01
Revertive: Non-Revertive
36